— 4 — — 5 — — 6 —
Wiring the Redundant Power Inputs
The IKS-6324 switch has two sets of power input—power input 1 and
power input 2.
STEP 1: Insert the dual set positive/negative DC wires into PWR1
and PWR2 terminals (+ Æ pins 1, 9, - Æ pins 2, 10). Or insert the L/N
AC wires into the PWR1 terminals (L Æ pin 1, N Æ pin 2).
STEP 2: To keep the DC or AC wires from pulling loose, use a
screwdriver to tighten the wire-clamp screws on the front of the
terminal block connector.
LED Indicators
The front panel of the IKS-6324
switch contains several LED
indicators. The function of each
LED is described in the table below.
LED Color State Description
System LEDs
On
System has passed self-diagnosis
test on boot-up and is ready to run.
GREEN
Blinking
System is undergoing the
self-diagnosis test.
STAT
RED On
System failed self-diagnosis on
boot-up.
On
Power is being supplied to the main
module’s power input PWR1.
PWR1 AMBER
Off
Power is not being supplied to the
main module’s power input PWR1.
On
Power is being supplied to the main
module’s power input PWR2.
PWR2 AMBER
Off
Power is not being supplied to the
main module’s power input PWR2.
On System initiation has failed.
FAULT RED
Off System initiation was successful.
Note: Use the Mode push-button switch to cycle among the LNK/ACT,
SPEED, and FDX/HDX LEDs. The status of these three settings is
indicated by the LEDs for the various ports. The system will switch to
LNK/ACT automatically after 5 seconds.
Mode LEDs
On
The corresponding module port’s
link is active.
Blinking
The corresponding module port’s
data is being transmitted.
LNK/ACT GREEN
Off
The corresponding module port’s
link is inactive.
Off
The corresponding module port’s
data is being transmitted at 10
Mbps.
On
The corresponding module port’s
data is being transmitted at 100
Mbps.
SPEED GREEN
Blinking
The corresponding module port’s
data is being transmitted at
1000 Mbps.
On
The corresponding module port’s
data is being transmitted at full
duplex.
FDX/HDX GREEN
Off
The corresponding module port’s
data is being transmitted at half
duplex mode.
* Slot 1 (M1) is mainly used for Gigabit modules. If 100BaseFX modules
are used in Slot 1 (M1), the modules will not support “Far End Fault”.
The Link/ACT LED indicator will stay at “Green (ON)” status when
Fiber TX cable is unplugged.
Specifications
Technology
Standards IEEE802.3, 802.3u, 802.3ab, 802.3z, 802.3x
Flow Control IEEE802.3x flow control, back pressure flow
control
Interface
Fast Ethernet 10/100BaseT(X) or 100BaseFX (SC/ST
connector)
Gigabit Ethernet 10/100/1000BaseT(X),
1000BaseSX/LX/LHX/ZX (SFP slot, LC
connector)
System LED
Indicators
STAT, PWR1, PWR2, FAULT
Module LED
Indicators
LNK/ACT, FDX/HDX, SPEED
Optical Fiber (100BaseFX)
Distance Multi mode
0 to 5 km, 1300 nm (50/125μm, 800 MHz*km)
0 to 4 km, 1300 nm (62.5/125μm, 500 MHz*km)
Single mode
0 to 40 km, 1310 nm (9/125μm, 3.5 PS/(nm*km))
Min. TX Output Multi mode: -20 dBm; Single mode: -5 dbm
Max. TX Output Multi mode: -10 dBm; Single mode: 0 dbm
RX Sensitivity -36 to -32 dBm (Single), -34 to -30 dBm (Multi)
Power
Input Voltage Low Voltage: 24/48 VDC (9 to 60 V)
High Voltage: 110/250 VDC (88 to 300 V)
and 100/240 VAC (85 to 264 V)
Input Current Max. 0.68A @ 24 VDC
Max. 0.35A @ 48 VDC
Max. 0.17/0.11A @ 110/220 VDC
Max. 0.33/0.23A @ 110/220 VAC
Connection 10-pin Terminal Block
Overload Current
Protection
6.3 A
Reverse Polarity
Protection
Present
Mechanical
Casing IP 30 protection, metal case
Dimensions
(W x H x D)
440 x 44 x 254 mm (17.32 x 1.73 x 10.00 in.)
Weight 4300g
Installation 19-inch Rack Mounting
Environmental
Operating Temp. -40 to 75°C (-40 to 167°F) for -T models
Storage Temp. -40 to 85°C (-40 to 185°F)
Ambient Relative
Humidity
5 to 95% (non-condensing)
Regulatory Approvals
Safety: EN60950-1 (Pending)
Maritime: ABS/BV/CCS/DNV/GL/KR/LR/NKK/PR/RINA
(Pending)
Road Traffic: NEMA TS2 (Pending)
EMI: FCC Part 15, CISPR (EN55022) class A
Railway EN50121-4 (Pending)
Shock & Vibration EN50155 (EN/IEC 61373, Category 1, Class B)
Warranty
5 years
Click here for online support:
www.moxa.com/support
The Americas:
+1-714-528-6777 (toll-free: 1-888-669-2872)
Europe:
+49-89-3 70 03 99-0
Asia-Pacific:
+886-2-8919-1230
China:
+86-21-5258-9955 (toll-free: 800-820-5036)
© 2008 Moxa Inc., all rights reserved.
Reproduction without permission is prohibited.