Moxa Technologies EtherDevice EDS-516A, EDS-516A Hardware Installation Manual

Moxa EtherDevice™ Switch
EDS-516A Series
Hardware Installation Guide
Fifth Edition, June 2010
Reproduction without permission is prohibited.
Fl.4, No.135, Lane 235, Pao-Chiao Rd. Shing Tien City, Taipei, Taiwan,
R.O.C.
TEL: +886-2-8919-1230
P/N: 1802005160013
- 2 -
Package Checklist
Moxa EtherDevice™ Switch is shipped with the following items. If any of these items are missing or damaged, please contact your customer service representative for assistance.
y 1 Moxa EtherDevice Switch EDS-516A
y Hardware Installation Guide
y CD-ROM with User’s Manual and Windows Utility
y Moxa Product Warranty Booklet
y RJ45 to DB9 Console port cable
y Protective caps for unused ports
y Panel mounting kit (optional—must order separately)
Optional Accessories
y DR-4524—45W/2A DIN-Rail 24 VDC Power Supply with 85 to 264
VAC input
y DR-75-24—75W/3.2A DIN-Rail 24 VDC Power Supply with 85 to 264
VAC input
y DR-120-24—120W/5A DIN-Rail 24 VDC Power Supply with 88 to 132
VAC/176 to 264 VAC input by switch
y EDS-SNMP OPC Server Pro—CD with EDS-SNMP OPC Server
Software and manual
y WK-46—Wall Mounting Kit
y RK-4U—4U-high 19" rack mounting kit
- 3 -
Panel Views of EDS-516A
9
12
15
6
6
6
6
10 11
13
14
7
8
16
17
16
1
3
2
4
5
MSTR/HEAD
CPLR/TAIL
1. Grounding screw
2. Console port
3. Heat dissipation orifices
4. 6-pin terminal block for DI 1, DI 2, and PWR 2
5. 6-pin terminal block for PWR1 Relay 1, and Relay 2
6. 10/100BaseT(X), ports 1 to 16
7. PWR 1: LED for power input 1
8. PWR 2: LED for power input 2
9. Fault LED
10. MSTR/HEAD LED
11. CPLR/TAIL LED
12. Turbo Chain Logo
13. TP port’s 100 Mbps LED
14. TP port’s 10 Mbps LED
15. Model Name
16. Screw hole for Wall Mounting Kit
17. DIN-Rail Kit
- 4 -
Panel Views of EDS-516A (SC/ST Type)
9
12
15
6
6
10 11
13
14
7
8
19
20
19
1
3
2
4
5
17
16 18
18
MSTR/HEAD
CPLR/TAIL
NOTE: The appearance of EDS-516A-MM-ST is identical to EDS-516A-MM-SC.
1. Grounding screw
2. Console port
3. Heat dissipation orifices
4. 6-pin terminal block for DI 1, DI 2, and PWR 2
5. 6-pin terminal block for PWR1 Relay 1, and Relay 2
6. 10/100BaseT(X), ports 1 to 14
7. PWR 1: LED for power input 1
8. PWR 2: LED for power input 2
9. Fault LED
10. MSTR/HEAD LED
11. CPLR/TAIL LED
12. Turbo Chain Logo
13. TP port’s 100 Mbps LED
14. TP port’s 10 Mbps LED
15. Model Name
16. 100BaseFX Port 15
17. 100BaseFX Port 16
18. 100BaseFX LEDs
19. Screw hole for Wall Mounting Kit
20. DIN-Rail Kit
- 5 -
Mounting Dimensions (unit = mm)
PWR1
PWR2
FAULT
MSTR/HEAD
CPLR/TAIL
100M
TX
13
11
9
14
12
10
7
5
3
8
6
4
1
2
100M
10M
TX
RX
16
RX
15
100M
Rear View
Side View
Front View
Wall Mounting Kit
DlN-Rail Kit
DlN-Rail Kit
DlN-Rail
127.52
46
70
7.75
30.50
7.75
9
36.9113.4
00.53
30.00
00.531
00.531
0.79
71.01
15.00
86.80
00.531
7.5 55 7.5
02.72
03.84
3.5
6
13.9
18.2
6
13.9
10 10
5
08.66
50.75
DIN-Rail Mounting
The aluminum DIN-Rail attachment plate should already be fixed to the back panel of EDS-516A when you take it out of the box. If you need to reattach the DIN-Rail attachment plate to EDS-516A, make sure the stiff metal spring is situated towards the top, as shown by the following figures.
STEP 1—Insert the top of the DIN-Rail into the slot just below the stiff metal spring.
STEP 2—The DIN-Rail attachment unit will snap into place as shown in the following illustration.
metal spring
DIN-Rail
metal spring
DIN-Rail
To remove the EDS-516A from the DIN-Rail, simply reverse Steps 1 and 2 above.
- 6 -
Wall Mounting (Optional)
For some applications, you will find it convenient to mount Moxa EDS-516A on the wall, as shown by the following illustrations:
STEP 1—Remove the aluminum DIN-Rail attachment plate from the Moxa EDS-516A rear panel, and then attach the wall mount plates with M3 screws, as shown by the figure on the right.
Ö
Top plate
Bottom plate
STEP 2—Mounting Moxa EDS-516A on the wall requires 4 screws. Use the EDS-516A, with wall mount plates attached, as a guide to mark the correct locations of the 4 screws. The heads of the screws should be less than 6.0 mm in diameter, and the shafts should be less than 3.5 mm in diameter, as shown by the figure on the right.
6.0 mm
3.5 mm
NOTE
Before tightening the screws into the wall, make sure the screw head and shank size are suitable by inserting the screw through one of the keyhole-shaped apertures of the Wall Mounting Plates.
Do not screw the screws in all the way—leave about 2 mm to allow room for sliding the wall mount panel between the wall and the screws.
STEP 3—Once the screws are fixed to the wall, insert the four screw heads through the wide parts of the keyhole-shaped apertures, and then slide the EDS-516A downwards, as indicated in the figure at the right. Tighten the four screws for more stability.
MSTR/HEAD
CPLR/TAIL
MSTR/HEAD
CPLR/TAIL
- 7 -
II 3G
ATEX Information
1. Certification number DEMKO 09 ATEX 0812123X
2. Ambient range (-40°C Tamb 75°C)
3. Certification string (Ex nC IIC T4)
4. Standards covered ( EN60079-0:2006, EN60079-15:2005)
5. The conditions of safe usage: y The Ethernet Communication Devices are to be mounted in an IP54
enclosure and used in an area of not more than pollution degree 2 as defined by IEC60664-1.
y A 4mm2 conductor must be used when connection to the external
grounding screw is utilized.
y Conductors suitable for use in an ambient temperature of 93°C must be
used for the Power Supply Terminal.
y Provisions shall be made, either in external to the apparatus, to prevent
the rated voltage being exceeded by the transients disturbances of more than 40%.
Wiring Requirements
WARNING
Do not disconnect modules or wires unless power has been switched off or the area is known to be non-hazardous. The devices may only be connected to the supply voltage shown on the type plate. The devices are designed for operation with a Safety Extra-Low Voltage. Thus, they may only be connected to the supply voltage connections and to the signal contact with the Safety Extra-Low Voltages (SELV) in compliance with IEC950/ EN60950/ VDE0805.
ATTENTION
This unit is a built-in type. When the unit is installed in another piece of equipment, the equipment enclosing the unit must comply with fire enclosure regulation IEC 60950/EN60950 (or similar regulation).
ATTENTION
Safety First!
Be sure to disconnect the power cord before installing and/or wiring your Moxa EtherDevice Switch.
Calculate the maximum possible current in each power wire and common wire. Observe all electrical codes dictating the maximum current allowable for each wire size.
If the current goes above the maximum ratings, the wiring could overheat, causing serious damage to your equipment.
- 8 -
You should also pay attention to the following points:
y Use separate paths to route wiring for power and devices. If power wiring
and device wiring paths must cross, make sure the wires are perpendicular at the intersection point
y NOTE: Do not run signal or communications wiring and power wiring
through the same wire conduit. To avoid interference, wires with different signal characteristics should be routed separately
y You can use the type of signal transmitted through a wire to determine
which wires should be kept separate. The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together
y Separate input wiring and output wiring
y We advise that you label wiring to all devices in the system when
necessary.
Grounding the Moxa EDS-516A
Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI). Run the ground connection from the ground screw to the grounding surface prior to connecting devices.
ATTENTION
This product is intended to be mounted to a well-grounded mounting surface such as a metal panel.
Wiring the Relay Contact
EDS-516A has two sets of relay outputs—relay 1 and relay 2. Each Relay Contact consists of the two contacts of the terminal block on EDS-516A’s top panel. You can refer to the next section for detailed instructions on how to connect the wires to the terminal block connector, and how to attach the terminal block connector to the terminal block receptor.
In this section, we will explain the meaning of the two contacts used to connect the Relay Contact.
Relay1 Relay2
Relay1 Relay2
FAULT: The two sets of relay contacts of the 6-pin terminal block connector are used to detect user-configured events. The two wires attached to the fault contacts form an open circuit when a user-configured event is triggered. If a user-configured event does not occur, the fault circuit remains closed.
Wiring the Redundant Power Inputs
EDS-516A has two sets of power inputs—power input 1 and power input
2.The top two contacts and the bottom two contacts of the 6-pin terminal
block connector on EDS’ top panel are used for EDS’ two digital inputs. The top and front views of one of the terminal block connectors are shown here.
- 9 -
PWR1
PWR2
V1- V1+
PWR1
V2- V2+
PWR2
V1- V1+ V2- V2+
STEP 1: Insert the negative/positive DC wires into the V-/V+ terminals, respectively. STEP 2: To keep the DC wires from pulling loose, use a small flat-blade screwdriver to tighten the wire-clamp screws on the front of the terminal block connector. STEP 3: Insert the plastic terminal block connector prongs into the terminal block receptor, which is located on the EDS-516A’s top panel.
Wiring the Digital Inputs
EDS-516A has two sets of digital inputs, DI 1 and DI 2. Each DI consists of two contacts of the 6-pin terminal block connector on EDS’s top panel, which are used for EDS’s two DC inputs. The top and front views of one of the terminal block connectors are shown here.
I1
D2I
I2
D1I
I1 I2
D2ID1I
STEP 1: Insert the negative (ground)/positive DI wires into the /I1 terminals, respectively. STEP 2: To keep the DI wires from pulling loose, use a small flat-blade screwdriver to tighten the wire-clamp screws on the front of the terminal block connector. STEP 3: Insert the plastic terminal block connector prongs into the terminal block receptor, which is located on the EDS-516A’s top panel.
Communication Connections
All models of EDS-516A have one RJ45 console port (RS-232 interface), between 14 and 16 10/100BaseTX Ethernet ports. Some models also have 2 100BaseFX (SC/ST-type connector) fiber ports.
In this section, we present two types of diagrams—Pinout Diagrams and Cable Wiring Diagrams—to convey information about the ports and the cables used to connect Moxa EDS-516A to other devices:
Pinouts—The meaning of the “Pinouts” diagrams is straightforward. The diagrams simply display the type of signal passing through each of the port’s pins.
Cable Wiring—Diagrams labeled “Cable Wiring” present standard cable wiring schemes for cables used to connect Moxa EtherDevice Switch’s ports to other devices. These diagrams display three pieces of information:
1. When building your own cable, refer to the “pin-to-pin” Cable Wiring information displayed between the two vertical dashed lines to see which pin of the connector on the left should be connected to which pin of the connector on the right.
- 10 -
2. The information to the left of the left vertical dashed lines gives the pinouts of the relevant Moxa EtherDevice Switch port.
3. The information to the right of the right vertical dashed line gives the pinouts of the opposing device’s port.
NOTE
1. The pin numbers for male DB9 and DB25 connectors, and
hole numbers for female DB9 and DB25 connectors are labeled on the connector. However, the numbers are typically quite small, so you may need to use a magnifying glass to see the numbers clearly.
2. The pin numbers for both 8-pin and 10-pin RJ45 connectors
(and ports) are typically not labeled on the connector (or port). Refer to the following Pinout and Cable Wiring diagrams to see how RJ45 pins are numbered
RS-232 Connection
Moxa EDS-516A has one RS-232 (10-pin RJ45) console port, located on the top panel. Use either an RJ45-to-DB9 or RJ45-to-DB25 cable (see the cable following wiring diagrams) to connect Moxa EDS-516A’s console port to your PC’s COM port. You may then use a console terminal program, such as Moxa PComm Terminal Emulator, to access Moxa EDS-516A’s console configuration utility.
RJ45 (10-pin) Console Port Pinouts
Pin Description
1 -----­2 DSR 3 -----­4 GND 5 TxD 6 RxD 7 GND 8 -----­9 DTR
10 ------
110
RJ45 (10-pin) to DB9 (F) Cable Wiring
RJ45 Plug Pin 1
Moxa
EtherDevice
Server
RJ45
Connector
DCD DSR
RTS
GND
TxD RxD CTS
DTR
COM Port
Female DB9 Connector
DCD DTR CTS GND RxD TxD RTS DSR
Cable Wiring
1 2 3
4/7
5 6 8 9
1 6 7 5 3 2 8 4
- 11 -
RJ45 (10-pin) to DB25 (F) Cable Wiring
RJ45 Plug Pin 1
Moxa
EtherDevice
Server
RJ45
Connector
DCD DSR
RTS
GND
TxD RxD CTS DTR
COM Port
Female DB2
5
Connector
DCD DTR CTS GND RxD TxD RTS DSR
Cable Wiring
1 2 3
4/7
5 6 8 9
8 6 4 7 2 3 5 20
10/100BaseT(X) Ethernet Port Connection
The 10/100BaseT(X) ports located on Moxa EtherDevice Switch’s front panel are used to connect to Ethernet-enabled devices. Most users will choose to configure these ports for Auto MDI/MDI-X mode, in which case the port’s pinouts are adjusted automatically depending on the type of Ethernet cable used (straight-through or cross-over), and the type of device (NIC-type or HUB/Switch-type) connected to the port.
In what follows, we give pinouts for both MDI (NIC-type) ports and MDI-X (HUB/Switch-type) ports. We also give cable wiring diagrams for straight-through and cross-over Ethernet cables.
RJ45 (8-pin, MDI) Port Pinouts
Pin Signal
1 Tx+ 2 Tx­3 Rx+ 6 Rx-
1
8
RJ45 (8-pin, MDI-X) Port Pinouts
Pin Signal
1 Rx+ 2 Rx­3 Tx+ 6 Tx-
1
8
RJ45 (8-pin) to RJ45 (8-pin) Straight-through Cable Wiring
Straight-Through Cable
RJ45 Plug Pin 1
Switch Port
RJ45
Connector
RJ45 Connecto
r
Tx+ Tx­Rx+ Rx-
NIC Port
Cable Wiring
3 3 6 6 1 1 2 2
Rx+ Rx­Tx+ Tx-
- 12 -
RJ45 (8-pin) to RJ45 (8-pin) Cross-over Cable Wiring
Cross-Over Cable
RJ45 Plug Pin 1
Switch Port (NIC Port)
RJ45
Connector
RJ45 Connector
Tx+ Tx­Rx+ Rx-
(Rx+) (Rx-) (Tx+) (Tx-)
(Tx+) (Tx-) (Rx+) (Rx-)
Switch Port (NIC Port)
Cable Wiring
3 1 6 2 1 3 2 6
Rx+ Rx­Tx+ Tx-
100BaseFx Ethernet Port Connection
The concept behind the SC/ST port and cable is quite straightforward. Suppose you are connecting devices I and II. As opposed to electrical signals, optical signals do not require a circuit in order to transmit data. Consequently, one of the optical lines is used to transmit data from device I to device II, and the other optical line is used transmit data from device II to device I, for full-duplex transmission.
All you need to remember is to connect the Tx (transmit) port of device I to the Rx (receive) port of device II, and the Rx (receive) port of device I to the Tx (transmit) port of device II. If you are making your own cable, we suggest labeling the two sides of the same line with the same letter (A-to-A and B-to-B, as shown by the following illustration, or A1-to-A2 and B1-to-B2).
SC-Port Pinouts SC-Port to SC-Port Cable Wiring
Tx
Rx
AA
BB
Cable Wiring
A A B B
ST-Port Pinouts ST-Port to ST-Port Cable Wiring
Tx
Rx
AA
B
Cable Wiring
A A B B
B
ATTENTION
This is a Class 1 Laser/LED product. To prevent damage to your eyes, do not stare directly into the laser beam.
- 13 -
LED Indicators
The front panel of Moxa EDS-516A contains several LED indicators. The function of each LED is described in the following table:
LED Color State Description
On
Power is being supplied to power input P1.
PWR1 AMBER
Off
Power is not being supplied to power input P1.
On
Power is being supplied to power input P2.
PWR2 AMBER
Off
Power is not being supplied to power input P2.
On
When the corresponding PORT alarm is enabled, and a user-configured event is triggered.
FAULT RED
Off
When the corresponding PORT alarm is enabled and a user-configured event is not triggered, or when the corresponding PORT alarm is disabled.
On
When the EDS-516A is set as the Master of the Turbo Ring, or as the Head of the Turbo Chain.
Blinking
The EDS-516A has become the Ring Master of the Turbo Ring, or the Head of the Turbo Chain, after the Turbo Ring or the Turbo Chain is down.
MSTR/HEAD GREEN
Off
When the EDS-516A is not the Master of this Turbo Ring or is set as the Member of the Turbo Chain.
On
When the EDS-516A coupling function is enabled to form a back-up path, or when it's set as the Tail of the Turbo Chain.
Blinking
When the Turbo Chain is down.
CPLR/TAIL GREEN
Off
When the EDS-516A disables the coupling function.
On
TP port’s 10 Mbps link is active.
Blinking
Data is being transmitted at 10 Mbps.
10M (TP)
GREEN
Off
TP port’s 10 Mbps link is inactive.
On
TP port’s 100 Mbps link is active.
Blinking
Data is being transmitted at 100 Mbps.
100M
(TP)
GREEN
Off
TP port’s 100 Mbps link is inactive.
- 14 -
Specifications
Technology
Standards IEEE 802.3 for 10BaseT,
IEEE 802.3u for 100BaseT(X) and 100Base FX, IEEE 802.3x for Flow Control, IEEE 802.1D for Spanning Tree Protocol, IEEE 802.1w for Rapid STP, IEEE 802.1Q for VLAN Tagging, IEEE 802.1p for Class of Service, IEEE 802.1X for Authentication, IEEE 802.3ad for Port Trunk with LACP
Protocols IGMPv1/v2, GMRP, GVRP, SNMPv1/v2c/v3,
DHCP Server/Client, DHCP Option 66/67/82, BootP, TFTP, SNTP, SMTP, RARP, RMON, HTTP, HTTPS, Telnet, SSH, Syslog, IPv6, LLDP, IEEE 1588 PTP, Modbus/TCP, SNMP Inform
MIB MIB-II, Ethernet-like MIB, P-BRIDGE MIB,
Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Group 1,2,3,9
Interface
RJ45 Ports 10/100BaseT(X) auto negotiation speed, F/H duplex
mode, and auto MDI/MDI-X connection
Fiber Ports optional 100BaseFX (SC/ST connector)
Console Port RS-232 (10-pin RJ45)
LED Indicators PWR1, PWR2, FAULT, 10/100M (TP port),
MSTR/HEAD and CPLR/TAIL
Alarm Contact Two relay outputs with current carrying capacity of
1A @ 24 VDC
Digital Input Two inputs with the same ground, but electrically
isolated from the electronics
• For state “1”: +13 to +30V
• For state “0”: -30 to +3V
• Max. input current: 8 mA
Optical Fiber
Power
Input Voltage 24 VDC (12 to 45 VDC), redundant inputs
Input Current (@24V) 0.44A: (EDS-516A)
0.51A: (EDS-516A-MM-SC/ST)
Connection Two removable 6-pin terminal blocks
Overload Current Protection Present
Reverse Polarity Protection
Present
Mechanical
Casing IP30 protection, metal case
Dimensions 95 × 135 × 140 mm (W × H × D)
- 15 -
Weight 1.586 kg
Installation DIN-Rail, Wall Mounting (optional kit)
Environment
Operating Temperature 0 to 60°C (32 to 140°F)
-40 to 75°C (-40 to 167°F) for -T models
Storage Temperature -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity
5% to 95% (non-condensing)
Regulatory Approvals
Safety UL 508, UL60950-1
CSA C22.2 No. 60950-1, EN60950-1
Hazardous Location UL/cUL Class I, Division 2, Groups A, B, C, and D,
ATEX, Zone 2, Ex nC IIC
EMI FCC Part 15, CISPR (EN55022) class A
EMS EN61000-4-2 (ESD), Level 2
EN61000-4-3 (RS), Level 3 EN61000-4-4 (EFT), Level 2 EN61000-4-5 (Surge), Level 3 EN61000-4-6 (CS), Level 3 EN61000-4-8 EN61000-4-11 EN61000-4-12
Shock IEC60068-2-27
Freefall IEC60068-2-32
Vibration IEC60068-2-6
WARRANTY 5 years
Technical Support Contact Information