- 15 -
Specifications
Technology
Standards IEEE802.3, 802.3u, 802.3x, 802.1D, 802.1Q,
802.1w, 802.1p
Protocols IGMP V1/V2 device, GMRP, GVRP, SNMPv1/ v2c/v3,
DHCP S erver/Client, T F TP, SNTP, SMTP, RARP,
RMON, HTTP, Telnet, Syslog, DHC P Option
66/67/82, Boo tP, LLD P, Modb us T CP, I Pv 6
MIB MIB-II, E th ernet-L ike MI B, P-BRIDG E MIB, RMON
MIB Group 1, 2, 3, 9, Bridg e MIB, RST P MIB
Forwarding and
Filtering Rate
148810 pps
Processing Type Store an d Forwa rd
Flow Control IEEE802.3x fl ow control, back press ure flow control
Interface
RJ45 Ports 10/100BaseT(X) auto negotiation speed, F/H duplex
mode, and auto MDI/MDI-X connection
Fiber Ports 100BaseFX ports (SC/ST connector)
Console RS-232 (RJ45)
LED Indicators PWR1, P W R2, FAUL T , 10/100M ( TP port),
100M (Fi b er Port) , CPLR/TAIL and MST R/HEAD
Relay Contact One relay output with current carrying capacity of 1A
@ 24 VD C
DIP Switc hes Master, Co upler, T urbo Ring, Reserve
Optical Fiber
Multi-mode Single-mode
Wavelength
1300 nm 1310 nm
Max. Tx
-10 dB m 0 dBm
Min. Tx
-20 dB m -5 dBm
Rx Sensitivity
-32 dB m -34 dB m
Link Budget
12 dB 29 dB
Typical Distance
5 km
a
, 4 kmb 40 kmc
Saturation -6 dBm -3 dBm
a. when using [50/125 μm, 800 MHz*km] cable
b. when using [62.5/125 μm, 500 MHz*km] cable
c. when using [9/125 μm, 3.5 PS/(nm*km)] cable
Power
Inp ut V oltage EDS-405A/408A:
12 to 45 VD C, redu ndant i np uts
EDS-408A-3S-SC-48:
±24/± 48 VDC (-60 to -19 VDC or 19 to 6 0
VDC), red undant i np ut s ( T he mixing o f
power polarity system is prohibi ted.)
Inp ut C urrent (@ 24 V) EDS-405A: Max. 0.24 A
EDS-408A: Max. 0.21 A
EDS-405A-MM, EDS-405A-SS: Max. 0.32 A
EDS-408A-MM, EDS-408A-SS: Max. 0.26 A
EDS-408A-3M/3S/2M1S/1M2S: Max. 0.32 A
Connection One r emo vab le 6 -pin terminal block
Overload Current Protection Present
Re ver se Po l ar i ty Pro te c ti on Present