Moxa Technologies EDS-305-M12 Hardware Installation Manual

MOXA EtherDevice Switch
EDS-305-M12
Hardware Installation Guide
First Edition, July 2007
Moxa Networking Co., Ltd.
Tel: +886-2-8919-1230 Fax: +886-2-8919-1231 www.moxa.com
support@moxa.com (Worldwide) support@usa.moxa.com (The Americas)
P/N:1802003050010
1
Overview
The MOXA EtherDevice™ EDS-305-M12 series of 5-port smart Ethernet switches provides a hardened and cost-effective solution for your Ethernet connections. The EDS-305-M12 switches are IP67-rated to provide protection against shock and foreign particles. IP67-rated products have the following characteristics: (1) dust proof, (2) protection against the effects of temporary immersion in water.
The EDS-305-M12 switches have a wide operating temperature range of -40 to75°C, and are designed to withstand a high degree of vibration and shock. The rugged hardware design makes the EDS-305-M12 switches perfect for ensuring that your Ethernet equipment can withstand the rigors associated with critical industrial applications. The switches are rated for use in hazardous locations (Class 1 Division 2/Zone 2), and comply with CE, FCC, UL, DNC, and GL Standards.
Package Checklist
Your EDS-305-M12 is shipped with the following items. If any of these items is missing or damaged, please contact your customer service representative for assistance.
y MOXA EtherDevice™ Switch y Hardware Installation Guide y Product Warranty Statement y Protective caps for unused ports and 8 port labels
Features
High Performance Network Switching Technology
y 5 10/100BaseT(X) ports (4-pin shielded M12 socket with D coding) y Broadcast storm protection y IEEE802.3/802.3u/802.3x y Store and Forward switching process type y 10/100M, Full/Half-Duplex, MDI/MDIX auto-sensing
Industrial Grade Reliability
y Active circuit protection y Robust connection y Dust and immersion proof
Rugged Design
y Casing design meets IP67 protection standards y M12 connectors for robust connections y Operating temperature range of 0 to 60°C, or extended operating
temperature range of -40 to 75°C
2
EDS-305-M12 Panel Layouts
Front Panel View
EDS-305-M12
1 2
3
5 4
6 8 7
8 7
7
1. M12 port’s 10/100 Mbps LED
2. 10/100BaseT(X) port (4-pin shielded M12 socket with D coding)
3. Port Label
4. Power input (5-pin shielded M12 socket with A coding)
5. Power input (PWR) LED
6. Model name
7. Holes for attaching the EDS-305-M12 to a wall with screws (there are 3
holes: bottom left, bottom right, and top middle)
8. Grounding screws
Mounting Dimensions (unit = mm)
Top View Side ViewFront View
3
Wiring Requirements
WARNING
Turn the power off before disconnecting modules or wires. The correct power supply voltage is listed on the product label. Check the voltage of your power source to make sure that you are using the correct voltage. Do NOT use a voltage greater than what is specified on the product label.
These devices must be supplied by a SELV source as defined in the Low Voltage Directive 2006/95/EC and 2004/108/EC.
ATTENTION
Safety First!
Be sure to disconnect the power cord before installing and/or wiring your MOXA switch.
This device has UL508 approval. Use copper conductors only, 60/75°C, Tighten To 4.5 pound-inches
ATTENTION
Safety First!
Calculate the maximum possible current in each power wire and common wire. Observe all electrical codes dictating the maximum current allowable for each wire size. If the current goes above the maximum ratings, the wiring could overheat, causing serious damage to your equipment.
You should also heed the following guidelines: y Use separate paths to route wiring for power and devices. If power wiring
and device wiring paths must cross, make sure the wires are perpendicular at the intersection point. NOTE: Do not run signal or communications wiring and power wiring in the same wire conduit. To avoid interference, wires with different signal characteristics should be routed separately.
y You can use the type of signal transmitted through a wire to determine
which wires should be kept separate. The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together.
y Keep input wiring and output wiring separated. y It is strongly advised that you label wiring to all devices in the system when
necessary.
Grounding the EDS-305-M12
Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI). Run the ground connection from the ground screw to the grounding surface prior to connecting devices.
4
ATTENTION
This product is intended to be mounted to a well-grounded mounting surface such as a metal panel.
10/100BaseT(X) Ethernet Port Connection
All EDS-305-M12 models have 5 10/100BaseT(X) Ethernet ports (4-pin shielded M12 socket with D coding). The 10/100TX ports located on the EDS-305-M12’s front panel are used to connect to Ethernet-enabled devices. Most users configure these ports for Auto MDI/MDI-X mode, in which case the port’s pinouts are adjusted automatically depending on the type of Ethernet cable used (straight-through or cross-over), and the type of device (NIC-type or HUB/Switch-type) connected to the port.
In what follows, we give pinouts for both MDI (NIC-type) ports and MDI-X (HUB/Switch-type) ports. We also give cable wiring diagrams for straight-through and cross-over Ethernet cables.
Pinouts for sockets on EDS-305-M12 Tx port
1
4
3
2
-Pin 1:
-Pin 2:
-Pin 3:
-Pin 4:
Tx + Rx + Tx ­Rx -
Power input
1
4
3
2
5
-Pin 1:
-Pin 2:
-Pin 3:
-Pin 4:
-Pin 5:
Input V+ Not assigned Input V­Not assigned Function ground
MDI Port Pinouts MDI-X Port Pinouts 8-Pin RJ45
Pin Signal
1 Tx + 2 Tx ­3 Rx + 6 Rx -
Pin Signal
1 Rx + 2 Rx ­3 Tx + 6 Tx -
18
5
M12 (4-pin) to M12 (4-pin)
Tx+ Rx+ Tx­Rx-
Cable Wiring
1 2 2  1 3 4 4 3
Rx+ Tx+ Rx­Tx-
M12 (4-pin) to RJ45 (8-pin) Straight-Through Cable Wiring
Straight-Through Cable
Tx+ Rx+ Tx­Rx-
Cable Wiring
1 1 2  3 3 2 4 6
Tx+ Rx+ Tx­Rx-
M12 (4-pin) to RJ45 (8-pin) Cross-Over Cable Wiring
Cross-Over Cable
Tx+ Rx+ Tx­Rx-
Cable Wiring
1 3 2  1 3 6 4 2
Tx+ Rx+ Tx­Rx-
Dual Speed Functionality & Switching
The EDS-305-M12’s 10/100 Mbps switched M12 ports auto negotiate with the connected device to use the fastest data transmission rate supported by both devices. All of MOXA’s EtherDevice switches are plug-and-play devices, so that software configuration is not required. The half/full duplex mode for the switched M12 ports is user dependent and changes (by auto-negotiation) to full or half duplex, depending on which transmission speed is supported by the attached device.
6
Switching and Address Learning
The EDS-305-M12 has an address table that can hold up to 1000 node addresses, which makes it suitable for use with large networks. The address tables are self-learning, so that as nodes are added or removed, or moved from one segment to another, the EDS-305-M12 automatically keeps up with new node locations. An address-aging algorithm causes the least-used addresses to be deleted in favor of newer, more frequently used addresses. To reset the address buffer, power down the unit and then power it back up.
Switching, Filtering, and Forwarding
Each time a packet arrives at one of the switched ports, a decision is made to filter or forward the packet. Packets with source and destination addresses belonging to the same port segment will be filtered, constraining those packets to one port, and relieving the rest of the network from the need to process them. A packet with destination address on another port segment will be forwarded to the appropriate port, and will not be sent to the other ports where it is not needed. Packets that are used in maintaining the operation of the network (such as the occasional multi-cast packet) are forwarded to all ports.
The EDS-305-M12 operates in the store-and-forward switching mode, which eliminates bad packets and enables peak performance to be achieved when there is heavy traffic on the network.
LED Indicators
Several LED indicators are located on the EDS-305-M12’s front panel. The function of each LED is described in the table below.
LED Color State Description
On
Power is being supplied to the power input.
PWR AMBER
Off
Power is not being supplied to the power input.
On TP port’s 10 Mbps link is active.
Blinking Data is being transmitted at 10 Mbps
LNK/ACT
(10M)
AMBER
Off TP port’s 10 Mbps link is inactive. On TP port’s 100 Mbps link is active
Blinking
Data is being transmitted at 100 Mbps.
LNK/ACT
(100M)
GREEN
Off TP port’s 100 Mbps link is inactive.
7
Auto-Negotiation and Speed Sensing
All of the EDS-305-M12’s Ethernet ports independently support auto-negotiation for speeds in the 10BaseT and 100BaseTX modes, with operation according to the IEEE 802.3u standard. This means that some nodes could be operating at 10 Mbps, while at the same time, other nodes are operating at 100 Mbps.
Auto-negotiation takes place when an M12 cable connection is made, and then each time a LINK is enabled. The EDS-305-M12 advertises its capability for using either 10 Mbps or 100 Mbps transmission speeds, with the device at the other end of the cable expected to advertise in the same way. Depending on what type of device is connected, this will result in agreement to operate at a speed of either 10 Mbps or 100 Mbps.
If an EDS-305-M12’s Ethernet port is connected to a non-negotiating device, it will default to 10 Mbps speed and half-duplex mode, as required by the IEEE
802.3u standard.
Specifications
Technology
Standards IEEE 802.3, 802.3u, 802.3x Processing Type Store and Forward, with IEEE802.3x full duplex,
back pressure flow control
Interface
M12 Ports 10/100BaseTX auto negotiation speed, F/H duplex
mode, and auto MDI/MDI-X connection LED Indicators Power, LNK/ACT Power Input Voltage 12 to 45 VDC or 18 to 30 VAC (47 to 63 Hz) Input Current 0.13A @ 24 VDC
0.28A @ 24 VAC
Connection One M12 socket (A-coding), single power input
Protection
Overload current protection / Limited current
1.1A
Reverse polarity protection
present
Mechanical
Casing IP67 protection, plastic case Dimensions (W x H x
D)
60 x 125 x 29.6 mm (2.4 x 4.9 x 1.2 in)
Weight 250g Installation Field-style mounting
Environment
Operating Temperature 0 to 60°C for standard model,
-40 to 75°C for -T models Storage Temperature -40 to 85ºC Operating relative
humidity
5 to 95%
(non-condensing)
8
MTBF > 200,000 hours
Regulatory Approvals
Safety UL 508 (pending) Hazardous Location UL/cUL Class1, Div.2, ATEX Class1, Zone2
(pending)
Maritime DNV, GL (pending)
EMI: FCC Part 15, CISPR (EN55022) class A EMS: EN61000-4-2 (ESD), level 3 EN61000-4-3 (RS), level 3 EN61000-4-4 (EFT), level 3 EN61000-4-5 (Surge), level 3 EN61000-4-6 (CS), level 2 Shock: IEC60068-2-27 Free Fall: IEC60068-2-32 Vibration: IEC60068-2-6
WARRANTY
5 years
MOXA Internet Services
Customer satisfaction is our number one concern, and to ensure that customers receive the full benefit of our products, MOXA has set up on-line support services to provide technical support, driver updates, product information, and user’s manual updates.
E-mail for technical support: support@moxa.com
(Worldwide)
support@usa.moxa.com
(The Americas)
Website for up to date product information: www.moxa.com
Loading...