Moxa Technologies AWK-4131A Quick Installation Manual

P/N: 1802041310020
*1802041310020*
AWK-4131A
Moxa AirWorks
Edition 1.0, June 2016
Technical Support Contact Information
www.moxa.com/support
Moxa Americas: Toll
-free: 1-888-669-2872
Tel:
1-714-528-6777
Fax:
1-714-528-6778
Moxa China (Shanghai office): Toll
-free: 800-820-5036
Tel:
+86-21-5258-9955
Fax:
+86-21-5258-5505
Moxa Europe: Tel:
+49-89-3 70 03 99-0
Fax:
+49-89-3 70 03 99-99
Moxa Asia-Pacific: Tel:
+886-2-8919-1230
Fax:
+886-2-8919-1231
Moxa India: Tel:
+91-80-4172-9088
Fax:
+91-80-4132-1045
2016 Moxa Inc. All rights reserved.
- 2 -
Table of Contents
Overview ............................................................................... - 3 -
Hardware Setup .................................................................... - 3 -
Package Checklist .............................................................. - 3 -
Panel Layout of the AWK-4131A .......................................... - 4 -
Mounting Dimensions ......................................................... - 5 -
Attaching Antennas ........................................................... - 5 -
Wall Mounting ................................................................... - 6 -
DIN-Rail Mounting (Optional) .............................................. - 7 -
To Install .................................................................... - 7 -
To Release .................................................................. - 7 -
Deployment Precautions ..................................................... - 8 -
Wiring Requirements .................................................... - 8 -
Grounding Moxa AWK-4131A .............................................. - 8 -
Installations with Cable-Extended Antennas for Outdoor
Applications ................................................................ - 8 -
Wiring the Redundant Power Inputs ..................................... - 9 -
Wiring the Digital Inputs and Relay Contact (Digital Output) .. - 10 -
Communication Connections ............................................. - 10 -
10/100BaseT(X) Ethernet Port Connection ..................... - 10 -
1000BaseT Ethernet Port Connection ............................ - 11 -
RS-232 Connection .................................................... - 11 -
Waterproofing the RJ45 Plug ........................................ - 12 -
LED Indicators ................................................................ - 13 -
Specifications ................................................................. - 14 -
Software Setup ................................................................... - 17 -
How to Access the AWK .................................................... - 17 -
First-Time Quick Configuration .......................................... - 17 -
Point-to-Multipoint Scenario (AP/Client Mode) ................ - 18 -
Point-to-Point Scenario (Master/slave mode) .................. - 20 -
- 3 -
Overview
The AWK-4131A IP68 outdoor industrial AP/bridge/client meets the growing need for faster data transmission speeds by supporting 802.11n technology and allowing 2X2 MIMO communication with a net data rate of up to 300 Mbps. The AWK-4131A is compliant with industrial standards and approvals covering operating temperature, power input voltage, surge, ESD, and vibration. The two redundant DC power inputs increase the reliability of the power supply, and the AWK-4131A can be powered via PoE to make deployment easier. The AWK-4131A can operate on either the 2.4 or 5 GHz bands and is backwards compatible with existing
802.11a/b/g deployments to future-proof your investments in wireless networks.
Notes for the Reader
WARNING
I
ndicates that death or personal injury may occur if proper
precautions are not taken.
ATTENTION
Indicates that possible damage to this product or your property may result if proper precautions are not taken.
NOTE
Highlights important information related to this product.
Hardware Setup
This section covers the hardware setup of the AWK-4131A.
Package Checklist
Moxa’s AWK-4131A is shipped with the following items. If any of these items are missing or damaged, please contact your customer service representative for assistance.
AWK-4131A wireless AP/bridge/client
2 2.4/5 GHz antennas: ANT-WDB-ANM-0502
Wall-mounting kit (includes 2 supports)
Field-installable power plug
Field-installable RJ45 plug
Metal cap to cover RJ45 connector
Metal cap to cover M12 female connector
Transparent plastic sticks for field-installable plugs
Quick installation guide (printed)
Warranty card
NOTE
The above items come with the AWK-4131A standard version. The package contents for customized versions may be different.
- 4 -
Panel Layout of the AWK-4131A
1. Antenna A port
2. Antenna B port
3. LEDs for PWR, FAULT, STATE, WLAN, and LAN
4. M12 A-coded connector for PWR1 and PWR2
5. M12 8-pin connector for DI/DO
6. 10/100/1000BaseT(X) RJ45 Port
7. RS-232 console port
8. Reset button
9. Screw holes for wall mounting
10.
Waterproof vent
11.
Grounding screw (M4)
12.
Screw holes for DIN-rail
mounting
ATTENTION
Please DO NOT open or remove the vent 10. The warranty will be invalid if the seal is removed. All exposed connecto
rs, including 1, 2, 4 - 8, should be tightly
covered with suitable caps when they are not in use.
- 5 -
Mounting Dimensions
Unit = mm
Attaching Antennas
By default, the AWK-4131A comes with two dual-band omni-directional antennas. Attach the antennas as illustrated below:
STEP 1:
Use your fingers to hold the antenna N-type connector (female) on the AWK-4131A.
STEP 2:
Screw the antenna N-type connector (male) onto the AWK-4131A device’s N-type connector.
Caution
Do not
hold the rubber plate to screw the antenna on to the
AWK-4131A device.
Antenna Metal N-type
Rubber plate
- 6 -
ATTENTION
Use the
correct antennas: Use the 2.4 GHz antenna if the
AWK
-4131A will operate in IEEE 802.11b/g/n. Use the 5GHz
antenna
for operations in IEEE802.11a/n. Make sure the
antenna
s are installed in a safe outdoor area and are protected
against lightning and surge current using
surge protection
systems.
Wall Mounting
In most applications, wall mount provides an easier installation. You will find it quite easy to mount AWK-4131A on the wall, as illustrated below.
STEP 1:
Attach the wall
-mounting kit
with M4 screws, as shown in the diagram below.
STEP 2: Mounting the
AWK-4131A on the wall
requires 4 screws. Use the
AWK-
4131A
device, with wall
-mounting kit
attached, as a guide to mark the correct locations of the 4 screws. The heads of the screws are recommended to be between 5.5 mm and 8.5 mm in
diameter, and the shafts should
not
be
more than 5.0
mm in diameter, as shown in the figure.
Do not drive the screws in all the way into the wall—leave a space of about 2 mm to allow room for sliding the wall-mounting kit between the wall and the screws.
ATTENTION
T
est the screw head and shank size by inserting the screws
into one of the keyhole shaped apertures of the wall-mounting plates before attaching the plate to the wall.
STEP 3:
Once the screws are fixed into the wall, insert the four screw heads through the large opening of the keyhole-shaped apertures on the AWK-4131A, and then slide the AWK-4131A downwards, as indicated in the illustration on the right. Tighten the four screws for added stability.
- 7 -
ATTENTION
To avoid environmental vibration or shock, you can consider a r
obust installation with four bigger screws, where
the shafts are between 7.0 mm and 8.5 mm in diameter, and fix the AWK-4131A directly onto the wall and tighten the screws.
DIN-Rail Mounting (Optional)
The DK
-DC50131 die-cast metal kit, which
can be bo
ught separately, enables
easy and
robust installation for the
AWK-4131A.
A pair
of DK
-DC50131s is needed to DIN-r
ail mount
the AWK
-4131A. To install the DIN-rail
mounting ki
ts, tightly attach the two DIN-r
ail
mounting kits on
to the rear panel of the
AWK
-4131A using 6 screws for each kit.
To Install
STEP 1:
Use the recessed button on the spring
-loaded
bracket to lock it into position.
STEP 2:
Insert the top of the DIN rail into the slot just b
elow the upper hook of the DIN-rail
mounting kit. Push the
AWK-4131A toward
the DIN r
ail until the DIN-rail attachment
bracket snaps into place.
To Release
STEP 1:
Use a screw driver to p
ull down
the two spring
-loaded brackets
from
the bottom until they are
fixed in the “release” position.
STEP 2: Pull the
AWK-4131A out and
upward.
Loading...
+ 14 hidden pages