AirWorks AWK-4131A User’s Manual
Edition 5.0, October 2017
www.moxa.com/product
© 2017 Moxa Inc. All rights reserved.
AirWorks AWK-4131A User’s Manual
Moxa China (Shanghai office)
The software described in this manual is furnished under a license agreement and may be used only in accordance with
the terms of that agreement.
Copyright Notice
© 2017 Moxa Inc. All rights reserved.
Trademarks
The MOXA logo is a registered trademark of Moxa Inc.
All other trademarks or registered marks in this manual belong to their respective manufacturers.
Disclaimer
Information in this document is subject to change without notice and does not represent a commitment on the part of
Moxa.
Moxa provides this document as is, without warranty of any kind, either expressed or implied, including, but not limited
to, its particular purpose. Moxa reserves the right to make improvements and/or changes to this manual, or to the
products and/or the programs described in this manual, at any time.
Information provided in this manual is intended to be accurate and reliable. However, Moxa assumes no responsibility for
its use, or for any infringements on the rights of third parties that may result from its use.
This product might include unintentional technical or typographical errors. Changes are periodically made to the
information herein to correct such errors, and these changes are incorporated into new editions of the publication.
-free: 1-888-669-2872
+1-714-528-6777
+1-714-528-6778
+49-89-3 70 03 99-0
+49-89-3 70 03 99-99
+91-80-4172-9088
+91-80-4132-1045
Technical Support Contact Information
www.moxa.com/support
-free: 800-820-5036
+86-21-5258-9955
+86-21-5258-5505
-Pacific
+886-2-8919-1230
+886-2-8919-1231
Table of Contents
1. Introduction ...................................................................................................................................... 1-1
Overview ........................................................................................................................................... 1-2
Package Checklist ............................................................................................................................... 1-2
Product Features ................................................................................................................................ 1-2
Product Specifications ......................................................................................................................... 1-3
Functional Design ............................................................................................................................... 1-6
LED Indicators ............................................................................................................................ 1-6
Beeper ....................................................................................................................................... 1-7
Reset Button ............................................................................................................................... 1-7
Relay (Digital Output) .................................................................................................................. 1-8
2. Getting Started ................................................................................................................................. 2-1
First-Time Installation and Configuration ............................................................................................... 2-2
Communication Testing ....................................................................................................................... 2-3
Function Guide ................................................................................................................................... 2-4
3. Web Console Configuration ............................................................................................................... 3-1
Configuration by Web Browser ............................................................................................................. 3-2
Overview ........................................................................................................................................... 3-4
Quick Setup ....................................................................................................................................... 3-6
General Setup .................................................................................................................................... 3-8
System Information ..................................................................................................................... 3-8
Interface On/Off .......................................................................................................................... 3-9
Network Settings ....................................................................................................................... 3-10
System Time ............................................................................................................................ 3-12
Wireless LAN Setup ........................................................................................................................... 3-13
AeroMag .................................................................................................................................. 3-14
Operation Mode ........................................................................................................................ 3-18
Basic WLAN Setup ..................................................................................................................... 3-19
WLAN Security Settings ............................................................................................................. 3-22
Advanced WLAN Settings ........................................................................................................... 3-29
WLAN Certificate Settings (For EAP-TLS in Client/Slave Mode Only) ................................................. 3-33
Advanced Setup ............................................................................................................................... 3-34
Using Virtual LAN .............................................................................................................................. 3-34
The Virtual LAN (VLAN) Concept .................................................................................................. 3-34
Configuring Virtual LAN .............................................................................................................. 3-35
DHCP Server (For AP/Client-Router Mode Only) ............................................................................. 3-36
Packet Filters ............................................................................................................................ 3-38
RSTP Settings (Master/Slave Mode Only) ..................................................................................... 3-41
Static Route (Client-Router Mode Only) ........................................................................................ 3-42
NAT Settings/Port Forwarding (Client-Router Mode Only) ............................................................... 3-43
SNMP Agent ............................................................................................................................. 3-45
Link Fault Pass-Through (Client/Slave Mode Only) ......................................................................... 3-47
Logs and Notifications ....................................................................................................................... 3-47
System Logs ............................................................................................................................. 3-48
Syslog ..................................................................................................................................... 3-49
E-mail Notifications ................................................................................................................... 3-50
Relay ....................................................................................................................................... 3-51
Trap ........................................................................................................................................ 3-52
Status ............................................................................................................................................. 3-54
Wireless LAN Status .................................................................................................................. 3-54
Associated Client List (for AP/Master Mode Only) ........................................................................... 3-54
DHCP Client List (For AP Mode Only) ............................................................................................ 3-55
System Logs ............................................................................................................................. 3-56
Relay Status ............................................................................................................................. 3-56
DI and Power Status .................................................................................................................. 3-57
AeroLink Protection Status (Client/Slave Mode Only) ..................................................................... 3-57
System Status .......................................................................................................................... 3-58
Network Status ......................................................................................................................... 3-58
Maintenance .................................................................................................................................... 3-59
Console Settings ....................................................................................................................... 3-59
Ping ......................................................................................................................................... 3-60
Firmware Upgrade ..................................................................................................................... 3-60
Configuration Import and Export ................................................................................................. 3-61
Load Factory Default .................................................................................................................. 3-62
Account Settings ....................................................................................................................... 3-62
Change Password ...................................................................................................................... 3-63
Misc. Settings ........................................................................................................................... 3-64
Troubleshooting ........................................................................................................................ 3-64
Save Configuration ........................................................................................................................... 3-66
Restart ............................................................................................................................................ 3-67
Logout ............................................................................................................................................ 3-67
4. Software Installation/Configuration ................................................................................................. 4-1
Overview ........................................................................................................................................... 4-2
Wireless Search Utility ......................................................................................................................... 4-2
Installing Wireless Search Utility ................................................................................................... 4-2
Configuring Wireless Search Utility ................................................................................................ 4-5
5. Other Console Configurations ............................................................................................................ 5-1
RS-232 Console Configuration (115200, None, 8, 1, VT100) .................................................................... 5-2
Configuration by Telnet and SSH Consoles ............................................................................................. 5-3
Configuration by Web Browser with HTTPS/SSL ...................................................................................... 5-4
Disabling Telnet and Browser Access ..................................................................................................... 5-5
A. References ........................................................................................................................................ A-1
AeroLink Protection ............................................................................................................................. A-2
Beacon .............................................................................................................................................. A-3
DTIM ................................................................................................................................................. A-3
Fragment ........................................................................................................................................... A-3
RTS Threshold .................................................................................................................................... A-3
STP and RSTP .................................................................................................................................... A-4
The STP/RSTP Concept ................................................................................................................ A-4
Differences between RSTP and STP ................................................................................................ A-4
B. Supporting Information .................................................................................................................... B-1
About This User’s Manual ..................................................................................................................... B-2
Firmware Recovery ............................................................................................................................. B-2
DoC (Declaration of Conformity) ........................................................................................................... B-4
Federal Communication Commission Interference Statement ............................................................ B-4
RED Compliance Statement ................................................................................................................. B-5
1
1. Introduction
The AWK-4131A industrial a/b/g/n high-speed wireless access point (AP) products are ideal wireless solutions
for hard-to-wire applications that use mobile equipment connected over a TCP/IP network. The AWK-4131A is
rated to operate at temperatures ranging from -40 to 75°C and is rugged enough for any harsh industrial
environment.
The following topics are covered in this chapter:
Overview
Package Checklist
Product Features
Product Specifications
Functional Design
LED Indicators
Beeper
Reset Button
Relay (Digital Output)
AirWorks AWK-4131A Introduction
The above items come with the
Overview
The AWK-4131A outdoor wireless access point is an ideal solution for industrial applications that are hard to
wire, too expensive to wire, or use mobile equipment that connect to a TCP/IP network. The AWK-4131A is
rated to operate at temperatures ranging from -40 to 75°C, and its dust-tight and weatherproof design is
IP68-rated. An IP68 rating means that the device is completely protected from the ingress of dust and is
protected against the effects of immersion in water at depths of 15 cm and 1 m. You can use the AWK-4131A
to set up a WLAN or extend existing wired networks to outdoor locations and still maintain a reliable connection.
The AWK-4131A has two redundant DC power inputs for increased reliability, can be powered via PoE, and is
easy to deploy.
Package Checklist
Moxa’s AWK-4131A is shipped with the following items. If any of these items is missing or damaged, please
contact your customer service representative for assistance.
• AWK-4131A wireless AP/bridge/client
• 2 2.4/5 GHz antennas: ANT-WDB-ANM-0502
• Wall mounting kit (includes 2 supports)
• Field-installable power plug
• Field-installable RJ45 plug (LAN)
• Metal cap to cover RJ45 connector (RS-232 Console)
• Metal cap to cover M12 female connector
• Transparent plastic sticks for field-installable plugs
• Quick installation guide (printed)
• Warranty card
Product Features
• IEEE802.11a/b/g/n compliant
• Three-in-one design (AP/bridge/client)
• Advanced wireless security:
64 -bit and 128-bit WEP/WPA/WPA2 encryption
SSID Hiding/IEEE 802.1X/RADIUS
Packet access control and filtering
• STP/RSTP support for network system redundancy (master and slave mode only)
• Long-distance transmission support (5 GHz channel only)
• Turbo Roaming enables rapid handover (client mode only)
• ABC-01 for configuration import/export
• Selectable antenna output
• RS-232 console management
• 2DI + 1DO for on-site monitoring and warnings
• Wide -40 to 75°C operating temperature range (-T model)
• Redundant 12 to 48 VDC power inputs or IEEE 802.3af Power over Ethernet
• DIN-rail or wall mounting ability
• IP68-rated metal housing
• Waterproof RJ45 connectors and M12 connectors
AWK-4131A standard version. The package contents may vary in different
AirWorks AWK-4131A Introduction
IEEE 802.11a/b/g/n for Wireless LAN
IEEE 802.3u for 100BaseT(X)
IEEE 802.3ab for 1000BaseT
IEEE 802.1D for Spanning Tree Protocol
IEEE 802.1w for Rapid STP
Spread Spectrum and Modulation (typi
• DSSS with DBPSK, DQPSK, CCK
• OFDM with BPSK, QPSK, 16QAM, 64QAM
• 802.11b: CCK @ 11/5.5 Mbps, DQPSK @ 2 Mbps, DBPSK @ 1 Mbps
• 802.11a/g: 64QAM @ 54/48 Mbps, 16QAM @ 36/24 Mbps, QPSK @ 18/12 Mbps, BPSK @ 9/6 Mbps
• 802.11n: 64QAM @ 300 Mbps to BPS
Operating Channels (central frequency):
*DFS (Dynamic Frequency Selection) channel support:
device will automatically switch to another channel. However according to regulations, after switching channels,
a 60
• SSID broadcast enable/disable
• Firewall for MAC/IP/Protocol/Port
Enterprise (IEEE 802.1X/RADIUS, TKIP, and AES)
802.11a/g: 6, 9, 12, 18, 24, 36, 48, 54
802.11n: 6.5 to 300 Mbps (multiple rates supported)
Product Specifications
Wireless Security
-over-Ethernet
cal):
K @ 6.5 Mbps (multiple rates supported)
2.412 to 2.462 GHz (11 channels)
5.180 to 5.240 GHz (4 channels)
5.260 to 5.320 GHz (4 channels)*
5.500 to 5.700 GHz (8 channels, excluding 5.600 to 5.640 GHz)*
5.745 to 5.825 GHz (5 channels)
2.412 to 2.472 GHz (13 channels)
5.180 to 5.240 GHz (4 channels)*
5.260 to 5.320 GHz (4 channels)
5.500 to 5.700 GHz (11 channels)*
2.412 to 2.484 GHz (14 channels)
5.180 to 5.240 GHz (4 channels)
5.260 to 5.320 GHz (4 channels)*
5.500 to 5.700 GHz (11 channels)*
In AP mode, when a radar signal is detected, the
-second availability check period is required before starting the service.
-based filtering
-bit and 128-bit WEP encryption, WPA/WPA2-Personal and
Mbps
Mbps
AirWorks AWK-4131A Introduction
Note: Based on regional regulations, the maximum transmission power allowed on the UNII bands is restricted in
the firmware
Typ. 26±1.5 dBm @ 1 Mbps, Typ. 26±1.5 dBm @ 2 Mbps
Typ. 26±1.5 dBm @ 5.5 Mbps, Typ. 25±1.5 dBm @ 11 Mbps
Typ. 23±1.5 dBm @ 6 to 24 Mbps, Typ. 21±1.5 dBm @ 36 Mbps
Typ. 19±1.5 dBm @ 48 Mbps, Typ. 18±1.5 dBm @ 54 Mbps
Typ. 23±1.5 dBm @ MCS0/8 20 MHz,
Typ. 18±1.5 dBm @ MCS7/15 20 MHz
Typ. 23±1.5 dBm @ MCS0/8 40 MHz,
Typ. 17±1.5 dBm @ MCS7/15 40 MHz
Typ. 23±1.5 dBm @ 6 to 24 Mbps, Typ. 21±1.5 dBm @ 36 Mbps
Typ. 20±1.5 dBm @ 48 Mbps, Typ. 18±1.5 dBm @ 54 Mbps
Typ. 23±1.5 dBm @ MCS0/8 20 MHz,
Typ. 18±1.5 dBm @ MCS7/15 20 MHz
Typ. 23±1.5 dBm @ MCS0/8 40 MHz,
Typ. 17±1.5 dBm @ MCS7/15 40 MHz
, as indicated below:
US EU JP
2.4 GHz 26 dBm 18 dBm 18 dBm
5 GHz (UNII-1) 23 dBm 23 dBm 23 dBm
5 GHz (UNII-2) 23 dBm 23 dBm 23 dBm
5 GHz (UNII-2e) 23 dBm 23 dBm 23 dBm
5 GHz (UNII-3) 23 dBm - -
-93 dBm @ 1 Mbps, -93 dBm @ 2 Mbps
-93 dBm @ 5.5 Mbps, -88 dBm @ 11 Mbps
-88 dBm @ 6 Mbps, -86 dBm @ 9 Mbps
-85 dBm @ 12 Mbps, -85 dBm @ 18 Mbps
-85 dBm @ 24 Mbps, -82 dBm @ 36 Mbps
-78 dBm @ 48 Mbps, -74 dBm @ 54 Mbps
-70 dBm @ MCS7 20 MHz, -69 dBm @ MCS15 20 MHz
-67 dBm @ MCS7 40 MHz, -67 dBm @ MCS15 40 MHz
-90 dBm @ 6 Mbps, -88 dBm @ 9 Mbps
-88 dBm @ 12 Mbps, -85 dBm @ 18 Mbps
-81 dBm @ 24 Mbps, -78 dBm @ 36 Mbps
-74 dBm @ 48 Mbps, -72 dBm @ 54 Mbps
):
-69 dBm @ MCS7 20 MHz, -71 dBm @ MCS15 20 MHz
-63 dBm @ MCS7 40 MHz, -68 dBm @ MCS15 40 MHz
Proxy ARP, DNS, HTTP, HTTPS, IP, ICMP, SNTP, TCP, UDP, RADIUS, SNMP, DHCP, VLAN,
AirWorks AWK-4131A Introduction
Connector for External Antennas:
Alarm Contact (digital output):
coded connector (female), 1 relay output with current carrying
capacity of 1 A @ 24 VDC
• +13 to +30 V for state “1”
• Max. input current: 8 mA
Ambient Relative Humidity:
Ethernet (IEEE 802.3af
compliant)
Reverse Polarity Protection:
Standards and Certifications
,
EAC Note: Please check Moxa’s website for the most up
MTBF (mean time between failures)
nnas: 2 dual-band omni-directional antennas, 5 dBi at 2.4 GHz, 2 dBi at 5 GHz, N-type (male)
N-Type (female), 500 V insulation
1, RJ45, 10/100/1000BaseT(X) auto negotiation speed, F/H duplex mode, and auto MDI/MDI-X
RS-232 (waterproof RJ45-type)
Present
PWR, FAULT, STATE, WLAN, LAN
8-pin M12 A-
8-pin M12 A-coded connector (female), 2 electrically isolated inputs
-30 V for state “0”
Wireless Search Utility, MXconfig, SNMP
nitoring: MXview
Metal, IP68 protection
1400 g (3.09 lb)
224 x 147.7 x 66.5 mm (8.82 x 5.82 x 2.62 in)
Wall mounting (standard), DIN-rail mounting (optional), pole mounting (optional)
-40 to 75°C (-40 to 167°F)
-40 to 85°C (-40 to 185°F)
5% to 95% (non-condensing)
12 to 48 VDC, redundant dual DC power inputs or 48 VDC Power-over-
0.64 A @ 12 VDC; 0.16 A @ 48 VDC
5-pin M12 A-coded connector (male), 500 V insulation
7.68 W
Present
UL 60950-1, EN 60950-1
EN 61000-6-2/6-4
CISPR 22, FCC Part 15B Class B
-4-2 ESD: Contact: 8 kV; Air: 15 kV
-4-3 RS: 80 MHz to 1 GHz: 10 V/m
-4-4 EFT: Power: 2 kV; Signal: 1 kV
00-4-5 Surge: Power: 2 kV; Signal: 2 kV
-4-6 CS: 10 V
-4-8
EN 301 489-1/17, EN 300 328, EN 301 893, MIC, FCC ID SLE-WAPN008, KC, RCM, WPC, ANATEL, SRRC
440,764 hrs
Telcordia SR332
See www.moxa.com/warranty
5 years
-to-date certification status.
AirWorks AWK-4131A Introduction
s and establish a wireless network
safely, a well
AWK-4131A is NOT a portable mobile device and should be located at least 20 cm away from the human
AWK-4131A is NOT designed for the general public. To deploy AWK-4131A
-trained technician is required for installation.
Functional Design
LED Indicators
The LEDs on the front panel of AWK-4131A allow you to identity the status and wireless settings quickly.
The LED for FAULT indicates the system failure and user-configured events. If the AWK-4131A cannot retrieve
the IP address from a DHCP server, the FAULT LED will blink at an interval of one second.
The following table is a summary for the wireless settings and LED displays. You can check the status of the
AWK-4131A by reading these LEDs. More information about “Basic Wireless Settings” is presented in Chapter
3.
LED Color State Description
Front Panel LED Indicators (System)
PWR Green
FAULT Red
STATE
Green
Red On System is booting up
On Power is being supplied (from power input 1 or 2, or PoE)
Off Power is not being supplied
Blinking
(slow at 1-sec
intervals)
Blinking
(fast at
0.5-sec
intervals)
Off No error condition exist
On System startup is complete and the system is in operation
Blinking (slow
at 1-second
intervals)
Blinking (fast
at 0.5-second
intervals)
Cannot get an IP address from the DHCP server
IP address conflict
Device has been located by the Wireless Utility
AeroLink Protection is enabled and is currently in “Backup” state
AirWorks AWK-4131A Introduction
ATTENTION
When the LEDs for STATE (Green), FAULT, and WLAN all light up simultaneously and blink at one
intervals, it means the system failed to boot. This may be due to impr
unexpected shutdown during firmware update. To recover the firmware, refer to “Firmware Recovery” in
Chapter 6.
Remove the reset button cover.
Using a pointed object, pr
LED Color State Description
On WLAN function is in Client/Client-Router/Slave mode
Green
WLAN
Amber
Green
LAN
Amber
Blinking WLAN’s data communication is in Client/Client-Router/Slave mode
Off WLAN is not in operation
On WLAN function is in AP/Master mode
Blinking WLAN’s data communication is in AP/Master mode
Off WLAN is not in operation
On LAN port’s 1000 Mbps link is active
Blinking Data is being transmitted at 1000 Mbps
Off LAN port’s 1000 Mbps link is inactive
On LAN port’s 10/100 Mbps link is active
Blinking Data is being transmitted at 10/100 Mbps
Off LAN port’s 10/100 Mbps link is inactive
Beeper
The beeper signals that the system is ready with two short beeps.
Reset Button
The RESET button is located on the bottom panel of the AWK-4131A. You can reboot the AWK-4131A or reset
it to factory default settings by pressing the RESET button with a pointed object such as an unfolded paper clip.
• System reboot: Hold the RESET button down for under 5 seconds and then release.
• Reset to factory default: Hold the RESET button down for over 5 seconds until the STATE LED starts
blinking green. Release the button to reset the AWK-4131A.
-second
oper operation or issues such as an
ess and hold the reset
AirWorks AWK-4131A Introduction
Relay (Digital Output)
The AWK-4131A has one relay output, which consists of the 2 contacts for the 8-pin M12 connector on the
bottom panel, as shown below. These relay contacts forward system failure and user-configured events.
The two wires attached to the relay contacts form an open circuit when a user-configured event is triggered. If
a user-configured event does not occur, the relay circuit will remain closed. For safety reason, the relay circuit
is kept open when the AWK-4131A is not powered.
The AWK-4131A’s relay status is summarized as follows:
Power Status Event Relay
Off – Open
On
Yes Open
No Short
Digital Inputs and Relay-out Pin Assignment (8-pin M12 connector)
PIN 1 2 3 4 5 6 7 8
Function DOUT_I DOUT_O DI0+ DI0- DI1+ DI1- reserved reserved
2
2. Getting Started
This chapter explains how to install Moxa’s AirWorks AWK-4131A for the first time, quickly set up your wireless
network, and test whether the connection is running well. With the function guide, you can easily locate the
functions you need.
The following topics are covered in this chapter:
First-Time Installation and Configuration
Communication Testing
Function Guide
AirWorks AWK-4131A Getting Started
will be
reset to factory default settings and the IP address will be also reset to
First-Time Installation and Configuration
Before installing the AWK-4131A, make sure all items in the Package Checklist are in the box. In addition, you
will need access to a notebook computer or PC equipped with an Ethernet port. The AWK-4131A has a default
IP address that you must use when connecting to the device for the first time.
Step 1: Select the power source.
The AWK-4131A can be powered by DC power input or PoE (Power over Ethernet). The AWK-4131A will use
whichever power source you choose.
Step 2: Connect the AWK-4131A to a notebook or PC.
Since the AWK-4131A supports MDI/MDI-X auto-sensing, you can use either a straight-through cable or
crossover cable to connect the AWK-4131A to a computer. If the LED indicator on AWK-4131A’s LAN port lights
up, it means the connection is established.
Step 3: Set up the computer’s IP address.
Set an IP address on the same subnet as the AWK-4131A. Since the AWK-4131A’s default IP address is
192.168.127.253, and the subnet mask is 255.255.255.0, you should set the IP address of the computer to
192.168.127.xxx.
Step 4: Use the web-based manager to configure AWK-4131A
Open your computer’s web browser and type http://192.168.127.253 in the address field to access the
homepage of the web-based Network Manager. Before the homepage opens, you will need to enter the user
name and password as shown in the following figure. For first-time configuration, enter the default user name
and password and then click on the Login button:
Maintenance Load Factory Default and click the Submit button, the AWK-4131A
192.168.127.253 .
AirWorks AWK-4131A Getting Started
Default user name and password:
For security reasons, we strongly recommend changing the default password. To do so, select
reminder will appear on the upper
after you change the settings. It will
take about 30 seconds for the AWK
User Name: admin
Password: mo xa (starting with firmware version 1.4)
root (up to firmware version 1.3)
Maintenance >
, and then follow the on-screen instructions to change the password.
Step 5: Select the operation mode for the AWK-4131A.
By default, the AWK-4131A’s operation mode is set to AP. If you would like to use the Client mode, you can
change the setting at Wireless LAN Setup --> WLAN --> Basic WLAN Setup . Detailed information about
configuring the AWK-4131A’s operation can be found in Chapter 3.
Step 6: Test the connection.
In the following sections, we describe two test methods that can be used to ensure that a network connection
has been established.
Submit will apply your changes and refresh the web page. The string “(Updated ) ” and a blinking
-right corner of web page as shown below:
effective, click Restart and then Save and Restart
-4131A to restart.
Communication Testing
After installation, you can run a sample test to make sure the AWK-4131A and wireless connection are
functioning normally. Two testing methods are explained in the following sections. Use the first method if you
are using only one AWK-4131A device, and use the second method if you are using two or more AWK-4131A
units.
Testing Method for one AWK-4131A
If you are only using one AWK-4131A, you will need a second notebook computer equipped with a WLAN card.
Configure the WLAN card to connect to the AWK-4131A (NOTE: the default SSID is MOXA ), and change the IP
address of the second notebook B so that it is on the same subnet as the first notebook A, which is connected
to the AWK-4131A.
After configuring the WLAN card, establish a wireless connection with the AWK-4131A and open a DOS window
on notebook B. At the prompt, type
ping <IP address of notebook A>
and then press Enter (see the figure below). A “Reply from IP address …” response means the communication
was successful. A “Request timed out.” response means the communication failed. In this case, recheck the
configuration to make sure the connections are correct.
AirWorks AWK-4131A Getting Started
SSID : Moxa
PING
Notebook B
IP: 192.168.127.1
Testing Method for two or more AWK-4131As
If you have two or more AWK-4131As, you will need a second notebook B equipped with an Ethernet port. Use
the default settings for the first AWK-4131A connected to notebook A and change the second or third
AWK-4131A connected to notebook B to Client mode. Then, configure the notebooks and AWK-4131As
properly.
AWK-4131A / Client
SSID: Moxa
Notebook A
IP: 192.168.127.2
AWK-4131A
IP: 192.168.127.253
AWK-4131A / AP
PING
Notebook B
IP: 192.168.127.1
After setting up the testing environment, open a DOS window on notebook B. At the prompt, type
ping <IP address of notebook A>
and then press Enter . A “Reply from IP address …” response means the communication was successful. A
“Request timed out” response means the communication failed. In this case, recheck the configuration to make
sure the connections are correct.
Function Guide
The management functions are categorized in a tree and shown in the left field of the web-based management
console. You can efficiently locate the function you need with the following guide.
Notebook A
IP: 192.168.127.2
AirWorks AWK-4131A Getting Started
Quick overview of the AWK-4131A’s status
General Setup for administering the AWK-4131A
Essential settings related to establishing a
wireless network
Advanced features to support additional network
management and secure wired and wireless
communication
Note: These advanced functions are all optional.
AirWorks AWK-4131A Getting Started
Application-oriented device management functions
to set up events, traps, and reactions via relay
warning, e-mail, and SNMP notification
Note: These functions are all optional.
Current status information for monitoring wired/wireless
network performance, advanced services, and device
management functions.
Functions for maintaining the AWK-4131A, and for
diagnosing the network.
On-demand functions to support the web-based console
management operation.
3
3. Web Console Configuration
In this chapter, we will explain each web management page of the web-based console configuration. Moxa’s
easy-to-use management functions will help you set up your AWK-4131A, as well as establish and maintain
your wireless network easily.
The following topics are covered in this chapter:
Configuration by Web Browser
Overview
General Setup
System Information
Network Settings
System Time
Wireless LAN Setup
Operation Mode
Basic WLAN Setup
WLAN Security Settings
Advanced WLAN Settings
AirWorks AWK-4131A Web Console Configuration
tions from a PC host connected to the same LAN as
the
is configured for other VLAN settings, you must make sure your PC host is on the
management VLAN.
Configuration by Web Browser
Moxa AWK-4131A’s web browser interface provides a convenient way to modify its configuration and access
the built-in monitoring and network administration functions. The recommended web browser is Microsoft
Internet Explorer 7.0 or 8.0 with JVM (Java Virtual Machine) installed.
Follow the steps below to access the AWK-4131A’s web-based console management.
1. Open your web browser (ex. Internet Explorer) and type the AWK-4131A’s IP address in the address field.
2. The Web Console Login page will open. Enter the password (User Name is set as admin ; the default
AWK-4131A’s management and monitoring func
AWK-4131A, you must make sure that the PC host and AWK-4131A are on the same logical subnet.
AWK-4131A
AWK-4131A’s default IP address is 192.168.127.253 .
Press Enter to establish the connection.
password is moxa if a new password has not been set.) and then click Login to continue.
®
You may need to wait a few moments for the web page to download onto your computer. Please note that the
model name and IP address of your AWK-4131A are both shown in the title of the web page. This information
can help you identify multiple AWK-4131A units.
If an incorrect username or password is entered, a warning message is displayed. The system will lock the user
account based on the settings configured in the Maintenance
count is 5 times and the default lockout time is 600 seconds.
Account Settings page. The default retry
AirWorks AWK-4131A Web Console Configuration
Once an account is locked, the user will have to wait out the duration of the lockout period before retrying.
3. Use the Quick Setup function on the homepage to quickly set up the AWK or click on the Overview button
to see the basic device settings. The Import/Export function helps you back up the system or to perform
a system recovery from an existing backup.
AirWorks AWK-4131A Web Console Configuration
The model name of the AWK
ndicates the country code. The
country code indicates the AWK
as an
example in the following figures. (The country code and model name that appears on your computer screen
may be different th
4. Click on the Home link to go back to the main page.
Use the menu tree on the left side of the browser to open the AWK-4131A functions.
In the following paragraphs, we describe each AWK-4131A management function in detail. A quick overview is
available in this manual in the “Function Map” section of Chapter 3.
Overview
The Overview page summarizes the AWK-4131A’s current status. The information is categorized into the
groups: System info , Device info, and 802.11 info .
-4131A is shown as AWK-4131A-XX, where XX i
-4131A version and which frequencies it uses. We use AWK -4131A-US
an the one shown here.)
AirWorks AWK-4131A Web Console Configuration
Click on SSID for more detailed 802.11 information, as shown in the following figure:
802.11 info that is displayed may be different for different operation modes. For example, Current
, Signal strength, and SNR are only available under Client/Client-Router/Slave operation modes.
AirWorks AWK-4131A Web Console Configuration
You can move your cursor on the question mark symbol next to a field to view a tooltip that provides additional
details re
Quick Setup
The AWK-4131A provides a quick setup wizard to help you configure the basic settings including device
information and wireless settings.
Once you enter the setup, links to each step in the process are displayed at the top of the page. You can either
click Next to go to the next step or click directly on the links at the top of the page to go to a specific step.
garding the corresponding field.
In the Wi-Fi Settings step, you can either use Manual to configure the basic Wi-Fi settings manually or click
AeroMag to opt for AeroMag to automatically set up your Wi-Fi network.
For additional details on the AeroMag function, refer to the Wireless LAN Setup section.
AirWorks AWK-4131A Web Console Configuration
If you use the Manual option to configure basic Wi-Fi settings, use the channel survey provided in the Channel
Usage section to find out if a channel is clear or congested. This function can help you deploy a clear channel
without requiring the use of an additional channel analysis tool.
AirWorks AWK-4131A Web Console Configuration
Setting Description
Number of APs The number of APs which use this channel
Load A measure of how congested a channel is, in percentage value. Both 802.11 and
non-802.11 signals will affect the channel loading.
Noise floor A summation of the noise level from all sources
You can see a complete preview of the Wi-Fi parameters that you configured when you click on the final step
in the setup process (Review Settings).
General Setup
The Basic Settings group includes the most commonly used settings required by administrators to maintain and
control the AWK-4131A.
System Information
The System Info items, especially Device name and Device description, are displayed and included on the
Overview page, SNMP information, and alarm emails. Setting System Info items makes it easier to identify
the different AWK-4131As connected to your network.
AirWorks AWK-4131A Web Console Configuration
resolve problems, use this space to record contact information
Enter the login authentication failure message to display to the
Device name
Format Description Factory Default
Max. 31 Characters This option is useful for specifying the role or application of
different AWK-4131A units.
Device location
Format Description Factory Default
Max. 31 Characters This specifies the location of different AWK-4131A units. None
Device description
Format Description Factory Default
Max. 31 Characters Use this space to record more detailed description of
AWK-4131A.
Device contact information
Format Description Factory Default
Max. 31 Characters To provide information about whom to contact in order to
of the person responsible for maintaining this AWK-4131A.
AWK-4131A
No. of this
AWK-4131A>
None
None
Login Message
Setting Description Factory Default
Max. of 31 characters Enter a message to display to all users when they log in Blank
Login authentication failure message
Setting Description Factory Default
Max. of 31 characters
Interface On/Off
None
user who logs in with an invalid username or password
AirWorks AWK-4131A Web Console Configuration
r used by your network. After
browser’s address field instead of entering the IP address. The
Network Settings
The Network Settings configuration panel allows you to modify the usual TCP/IP network parameters.
However, due to the addition of the Client-Router operation mode, this panel provides two different sets of
network parameters. Explanations for both types of configuration are given below.
Network Settings for AP/Client/Master/Slave Operation Modes
IP address assignment
Setting Description Factory Default
DHCP The AWK-4131A’s IP address will be assigned automat
the network’s DHCP server.
Static Set up the AWK-4131A’s IP address manually.
IP address
Setting Description Factory Default
AWK-4131A’s IP
address
Subnet mask
Setting Description Factory Default
AWK-4131A’s subnet
mask
Gateway
Setting Description Factory Default
AWK-4131A’s default
gateway
Identifies the AWK-4131A on a TCP/IP network. 192.168.127.253
Identifies the type of network to which the AWK-4131A is
connected (e.g., 255.255.0.0 for a Class B network, or
255.255.255.0 for a Class C network).
The IP address of the router that connects the LAN to an
outside network.
Static
255.255.255.0
None
Primary/ Secondary DNS server
Setting Description Factory Default
IP address of the
Primary/Secondary
DNS server
The IP address of the DNS Serve
entering the DNS Server’s IP address, you can input the
AWK-4131A’s URL (e.g., http://ap11.abc.com) in your
Secondary DNS server will be used if the Primary DNS server
fails to connect.
None
AirWorks AWK-4131A Web Console Configuration
WLAN interface’s IP address manually.
’s WLAN
interface is connected (e.g., 255.255.0.0 for a Class B network,
The IP address of the DNS Server used by your network. After
entering the IP address. The
Network Settings for Client-Router Operation Mode
WLAN IP address assignment
Setting Description Factory Default
DHCP The AWK-4131A WLAN interface’s IP address will be assigned
automatically by the network’s DHCP server.
Static Set up the AWK-4131A
WLAN IP address
Setting Description Factory Default
AWK-4131A WLAN
interface’s IP address
WLAN subnet mask
Setting Description Factory Default
AWK-4131A WLAN
interface’s subnet mask
WLAN gateway
Setting Description Factory Default
AWK-4131A WLAN
interface’s default
gateway
Identifies the AWK-4131A WLAN interface’s IP address on a
TCP/IP network.
Identifies the type of network to which the AWK-4131A
or 255.255.255.0 for a Class C network).
The IP address of the router that connects the WLAN to an
outside network.
Static
192.168.128.253
255.255.255.0
None
Primary/Secondary DNS server
Setting Description Factory Default
IP address of the
Primary/Secondary
DNS server
entering the DNS Server’s IP address, you can input the
AWK-4131A’s URL (e.g., http://ap11.abc.com) in your
browser’s address field instead of
Secondary DNS server will be used if the Primary DNS server
fails to connect.
None
AirWorks AWK-4131A Web Console Configuration
interface is connected (e.g., 255.255.0.0 for a Class B network,
term shutdown, especially when the network
does not have an Internet connection for
LAN IP address
Setting Description Factory Default
AWK-4131A LAN
interface’s IP address
LAN subnet mask
Setting Description Factory Default
AWK-4131A LAN
interface’s subnet mask
Identifies the AWK-4131A LAN interface’s IP address on a
TCP/IP network.
Identifies the type of network to which the AWK-4131A’s LAN
or 255.255.255.0 for a Class C network).
192.168.127.254
255.255.255.0
System Time
The AWK-4131A has a time calibration function based on information from an NTP server or user specified Date
and Time information. Functions such as Logs and Notifications can add real-time information to the
message.
The Current local time shows the AWK-4131A’s system time when you open this web page. You can click on
the Set Time button to activate the updated date and time parameters. An “(Updated)” string will appear to
indicate that the change is complete. Local system time will be immediately activated in the system without
running Save and Restart.
AWK-4131A has a built-in real-time clock (RTC). We strongly recommend that users update the
for the AWK-4131A after the initial setup or a long-
accessing the NTP server or there is no NTP server on the LAN.
Current local time
Setting Description Factory Default
User adjustable time The date and time parameters allow configuration of the local
time, with immediate activation.
Use 24-hour format: yyyy/mm/dd hh:mm:ss
Time zone
Setting Description Factory Default
User selectable time
zone
The time zone setting allows conversion from
Mean Time) to local time.
None
GMT (Greenwich
Mean Time)