A. Regulatory Statements............................................................................. A-1
The following topics are covered in this chapter:
Overview
Features
Specifications
1.
Introduction
1
Overview
Moxa Sub-1G module(ZB-DCU3-T, ZB-PM3-T, ZB-WAN1-T) uses ATMEL
wireless microcontroller which provides a comprehensive solution with large
memory(256KB Flash and 16KB SRAM), high CPU and radio performance and all
RF components included.
The module is a range of ultra low power, high performance surface mount
modules targeted at Sub-1G networking applications, enabling users to realize
products with minimum time to market and at the lowest cost. Sub-1G
module(ZB-DCU3-T, ZB-PM3-T, ZB-WAN1-T) can implement networking stacks,
such as ZigBee, as well as customer applications
Note:
* The Sub-1G module will implement into Moxa System’s DCU and CFE/Protecsa’s
Smart Meter application. So, it should follow Moxa System’s DCU-8620-T specification
and CFE/Protecsa AMI specification that provided by CFE company.
EMC: CE (EN55022 and EN55024 Class A), FCC Part 15 Subpart B Class A
Reliability
Automatic Reboot Trigger: Built-in WDT (watchdog timer)
MTBF (meantime between failures): Over 10 years
Warranty
Warranty Period: 5 years
Details: See www.moxa.com/warranty
2
2.
Getting Started
This chapter covers the module layout, and block diagram, hardware installation
of the Sub-1G module. Software installation is covered in the next chapter.
Module Layout
Block Diagram
Connector Locations
Hardware Installation
Software Installation
Module Layout
ZB-DCU3-T, ZB-WAN1-T
+
ZB-PM3-T
+
Block Diagram
=
=
PIN Define
PIN Number
PIN Function
ZB-DCU3-T, ZB-WAN1-T
PIN Number PIN Function PIN Number PIN Function
1 3.3V 2 3.3V
3 GND 4 GND
5 GND 6 GND
7 NC 8 NC
9 NC 10 NC
11 RXD 12 NC
13 TXD 14 NC
15 NC 16 NC
17 NC 18 NC
19 NC 20 RESET
ZB-PM3-T
1 VCC
2 TXD
3 RXD
4
5
6
7
RST
NC
GND
GND
Hardware Installation
The Sub-1G Module can be installed into Moxa DCU-8620-T Embedded
Computer system and Power Meter.
Steps for Installation on DCU
1. Attach the WLAN antenna to connector UI.
2. Let Sub-1G Module(ZB-DCU3-T and ZB-WAN1-T) connect to DCU-8620-T.
3. Screw on the Sub-1G Module
Steps for Installation on Power Meter
1. Let Sub-1G Module(ZB-PM3-T) connect to Power Meter.
2. Recover the Power Meter.
Software Installation
After physically installing the Sub-1G module, the module will be recognized on
the new system board after the following steps.
Steps for Installation
1. Apply power to the system board.
2. Run DCU-8620-T application program. Make sure it could communicate with
Sub-1G module(ZB-WAN1-T and ZB-DCU3-T).
3. Apply power to the Power Meter. Make sure the LED of “Ready” light-on on
Power Meter.
4. Run DCU-8620-T application program, make sure it could read data from
Power Meter through the air.
A
A.
Regulatory Statements
Federal Communication Commission Interference Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to operate this equipment.
This transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter.
Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance
20cm between the radiator & your body.
This device is intended only for OEM integrators under the following conditions:
1) The antenna must be installed such that 20 cm is maintained between the antenna
and users, and
2) The transmitter module may not be co-located with any other transmitter or antenna.
As long as 2 conditions above are met, further transmitter test will not be required.
However, the OEM integrator is still responsible for testing their end-product for any
additional compliance requirements required with this module installed
IMPORTANT NOTE: In the event that these conditions can not be met (for example certain
laptop configurations or co-location with another transmitter), then the FCC authorization
is no longer considered valid and the FCC ID can not be used on the final product. In these
circumstances, the OEM integrator will be responsible for re-evaluating the end product
(including the transmitter) and obtaining a separate FCC authorization.
End Product
Labeling
This transmitter module is authorized only for use in device where the antenna may be
installed such that 20 cm may be maintained between the antenna and users. The final
end product must be labeled in a visible area with the following: “Contains FCC
ID: SLE-ZB-PM3-T” or “Contains FCC ID: SLE-ZB-DCU3-T”. The grantee's FCC ID can be used
only when all FCC compliance requirements are met.
Manual Information To the End User
The OEM integrator has to be aware not to provide information to the end user regarding
how to install or remove this RF module in the user’s manual of the end product which
integrates this module.
The end user manual shall include all required regulatory information/warning as show in
this manual.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.