Moxa UC-2116-T-LX, UC-2114-T-LX User Manual

P/N: 1802021000211
Technical Support Contact Information
www.moxa.com/support
Moxa Americas: Toll Tel: Fax:
Moxa China (Shanghai office): Toll Tel: Fax:
Moxa Europe: Tel: Fax:
Moxa Asia-Pacific: Tel: Fax:
Moxa India: Tel: Fax:
2019 Moxa Inc. All rights reserved.
UC-2100-W Series
Quick Installation Guide
Version 2.0, October 2019
-free: 1-888-669-2872 1-714-528-6777
1-714-528-6778
+49-89-3 70 03 99-0
+49-89-3 70 03 99-99
+91-80-4172-9088
+91-80-4132-1045
-free: 800-820-5036 +86-21-5258-9955
+86-21-5258-5505
+886-2-8919-1230
+886-2-8919-1231
*1802021000211*

Overview

NOTE
The console cable and power jack can be found inside the product box, beneath the molded-pulp cushion.
The UC-2100-W Series computing platform is designed for embedded data acquisition and processing applications. The computer comes with up to two software-selectable RS-232/422/485 full-signal serial ports and single or dual Ethernet LAN ports. In addition, the Arm-based computing platform is available in various models that can fulfill diverse interface requirements, such as dual serial, LAN ports, and wireless connections. These versatile communication capabilities let users efficiently adapt the palm-sized computing platform to a variety of complex communications solutions.

Model Names and Package Checklist

The UC-2100-W Series includes the following models:
UC-2114-T-LX
UC-2116-T-LX Before installing a UC-2100-W computer, verify that the package
contains the following items:
• UC-2100-W Series computer
• Console cable
• Power jack
• Quick Installation Guide (printed)
• Warranty card Notify your sales representative if any of the above items are missing
or damaged.
- 2 -

Appearance

UC-2114

UC-2116

- 3 -

LED Indicators

LED Name
Status
Function
Power
Green
Power is on, and the device is functioning normally
Off
Power is off
Ethernet
Green
Steady On: 10 Mbps Ethernet link
progress
Yellow
Steady On: 100 Mbps Ethernet link
progress
Off
Speed lower than 10 Mbps or the cable is not connected
Ethernet
Green
Steady On: 100 Mbps Ethernet link
progress
progress
Off
Speed lower than 10 Mbps or the cable is not connected
Serial (Tx)
Green
Serial port is transmitting data
Off
Serial port is not transmitting data
Yellow
Serial port is receiving data
Off
Serial port is not receiving data
User
Green/Yellow
User Programmable
LEDs that
Yellow
The number of glowing LEDs
1 LED : Poor
Off
Wireless module is not detected
CAN1/CAN2 (Tx)
Green
CAN port is transmitting data
Off
CAN port is not transmitting data
CAN1/CAN2 (Rx)
Green
CAN port is receiving data
Off
CAN port is not receiving data
The function of each LED is described in the table below:
(10/100 Mbps)
(10/100/1000 Mbps)
Serial (Rx)
indicate the Wireless signal strength
Blinking: Data transmission is in
Blinking: Data transmission is in
Blinking: Data transmission is in
Yellow Steady On: 1000 Mbps Ethernet link
Blinking: Data transmission is in
indicates the signal strength 3 LEDs: Excellent 2 LEDs : Good

Reset Button

The UC-2100-W Series computer is provided with a reset button, which is located on the top panel of the computer. To reboot the computer, press the reset button less than 1 second. Press and hold the reset button between 7 to 9 seconds to reset the computer to the factory default settings. When the reset button is held down, the User LED will blink twice every second. The User LED will become steady when you hold the button continuously for 7 to 9 seconds. Release the button within this period to load the factory default settings.
- 4 -

Installing the Computer

NOTE
Do not run signal or communication wiring and power wiring in the same wire conduit. To avoid interference, wires with different signal characteristics should be routed separately.
ATTENTION
This equipment is intended to be used in Restricted Access Locations.
Safety First!
Be sure to disconnect the power cord before installing and/or wiring your
Wiring Caution!
Calculate the maximum possible current in each power wire and common wire. Observe all electrical codes dictating the maximum current allo goes above the maximum ratings, the wiring could overheat, causing serious damage to your equipment.

Wall or Cabinet Mounting

Use two screws per side to mount the UC-2100-W Series on a wall or inside a cabinet.

Wiring Requirements

Be sure to read and follow these common safety precautions before proceeding with the installation of any electronic device:
• Use separate paths to route wiring for power and devices. If power wiring and device wiring paths must cross, make sure the wires are perpendicular at the intersection point.
• Use the type of signal transmitted through a wire to determine which wires should be kept separate. The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together.
• Keep input wiring and output wiring separate.
• It is strongly advised that you label wiring to all devices for easy identification.
UC-2100-W Series computers.
wable for each wire size. If the current
- 5 -
CAUTION
Be careful when handling the unit. When the unit is plugged in, the internal components generate outer casing may feel hot to the touch.
Connect the 9 to 48 VDC power line to the
I
This product is intended to be supplied by a UL Listed power adapter The power source must be and minimum Tma = 75°C.

Connecting the Power

terminal block, which is connected to the UC­2100-W Series computer. If the power is supplied properly, the “Power” LED will glow a solid green light. The power input location and pin definition are shown in the adjacent diagram. The input terminal block (CN5) is suitable for a wire size of 12 to 30 AWG (3.3 to
0.05 mm (4.425 lb-in).
MPORTANT
heat, and consequently the
2
) and a torque value of 0.5 N-m
or DC power source whose output meets SELV/LPS.
rated 9 to 48 VDC, minimum 0.6 A,

Grounding the Unit

Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI). Run the ground connection from the terminal block connector to the grounding surface prior to connecting the power. Please note that this product is intended to be mounted on a well-grounded mounting surface, such as a metal panel. The minimum cross-sectional area of the earthing conductor shall be equal to the input wiring cable.

Connecting to the Console Port

The UC-2100-W console port is a 4-pin pin-header RS-232 port located on the right panel of the case. It is designed for serial console terminals, which are useful for viewing the boot up message, or for debugging system boot up issues. Remove the protective cover on the port to connect the console cable.
- 6 -
Serial Console Port & Pinouts
Serial Console Cable
Pin
Signal
1
TxD 2 RxD 3 NC 4 GND
Pin
10/100 Mbps
10/100/1000 Mbps
1
Tx+
TRD(0)+
2
Tx-
TRD(0)-
3
Rx+
TRD(1)+
4 – TRD(2)+
5 – TRD(2)-
6
Rx-
TRD(1)-
7 – TRD(3)+
8 – TRD(3)-
The serial ports are located on the bottom panel of the to ser connectors and can be configured for RS RS location and assignments are shown in the following table.
RS-485
(4-wire)
RS-485
(2-wire)
1
DCD
TxDA(-)
TxDA(-)
– 2 RxD
TxDB(+)
TxDB(+)
– 3 TxD
RxDB(+)
RxDB(+)
DataB(+)
4
DTR
RxDA(-)
RxDA(-)
DataA(-)
5
GND
GND
GND
GND 6 DSR – – – 7
RTS – – – 8
CTS – –

Connecting to the Network

The Ethernet ports are located on the top or bottom panel of the UC­2100-W computers. The pin assignments for the Ethernet port are shown in the following figure. If you are using your own cable, make sure that the pin assignments on the Ethernet cable connector match the pin assignments on the Ethernet port.

Connecting to a Serial Device

UC-2100-W computer. Use a serial cable
connect your serial device to the computer’s
ial port. These serial ports have male DB9
-422, or RS-485 communication. The pin
Pin RS-232 RS-422
-232,
- 7 -

Connecting to a CAN Device

Pin
Signal
1
GND 2 L 3 Chassis 4 H 5 Vout
1. Remove the screw on the cover located
the SIM card and release it.
below the
.
To remove the
card, simply push the
card in and release it.
The UC-2114 and UC-2116 come with two CAN ports, which use the 5­pin terminal block and are compatible with the CAN 2.0A/B standard. The pin assignment of the port is shown below.

Installing SIM Cards

You will need to install a SIM card on your UC-2100-W computer. Follow these steps to install the SIM card.
on the right panel.
2. Insert the SIM card into the socket. Make sure you place the chip-side on the bottom.
3. To remove the SIM card, simply push

Installing the microSD Card

Both UC-2114 and UC-2116 come with a storage socket that allows users to install one microSD card. Follow these steps to install the microSD card:
1. The microSD socket is located right panel of the computer. Unfasten the screw and remove the right panel cover.
2. Insert the microSD card into the socket Ensure that the card is inserted in the right direction.
3. Replace the cover and fasten the screw on the cover to secure the cover.
microSD

Adjusting the DIP Switch

The UC-2114 and UC-2116 computers come with one DIP switch for users to adjust the serial port parameters. To set up the DIP s witch, do the following:
- 8 -
1. Remove the screws on the DIP switch cover
located on the rear panel of the computer.
2. Remove the thin film on the DIP switch and
1 2 3 4 Low
High
Term.
ON
1
1
120 Ω
OFF
150
150
ATTENTION
There is a risk of explosion if the battery is replaced wi incorrect type of battery
ATTENTION
Remember to choose the “VT100” terminal type. Use the console cable to connect a PC to the UC console port
Default IP Address
Netmask
LAN 1
192.168.3.127
255.255.255.0
LAN 2
192.168.4.127
255.255.255.0
adjust the setting as required. Refer to the table below for the DIP switch settings. The default value is OFF.
SW

Real-time Clock

The real-time clock in the UC-2100-W is powered by a lithium battery. We strongly recommend that you do not replace the lithium battery without the help of a Moxa support engineer. If you need to change the battery, contact the Moxa RMA service team.
.
th an

Accessing the UC-2100-W Using a PC

You can use a PC to access the UC-2100-W by one of the following methods:
A. Through the serial console port with the following settings:
Baudrate = 115200 bps, Parity = None, Data bits = 8, Stop bits = 1, Flow Control = None.
.
B. Using SSH over the network.
Refer to the following IP addresses and login information:
Login: moxa Password: moxa
- 9 -
-2100-W's serial
Loading...