Overview

The NPort 6150/6250 series secure serial device servers provide reliable serial-to-Ethernet connectivity for a wide range of serial devices. The NPort 6150/6250 support TCP Server, TCP Client, UDP, and Pair-Connection operation modes to ensure the compatibility of network software. In addition, the NPort 6150/6250 also support Secure TCP Server, Secure TCP Client, Secure Pair-Connection, and Secure Real COM modes for security critical applications such as banking, telecom, access control, and remote site management.

Package Checklist

Before installing a NPort 6150/6250 secure device server, verify that the package contains the following items:
• NPort 6150 or NPort 6250
• Power adapter (does not apply to -T models)
• 2 wallmount ears
• Documentation and software CD
• Quick installation guide (this guide)
• Warranty card

Optional Accessories

• DK-35A: DIN-rail mounting kit (35 mm)
• DIN-rail power supply
• CBL-RJ45M9-150: 8-pin RJ45 to male DB9 cable
• CBL-RJ45M25-150: 8-pin RJ45 to ma le DB25 cable
NOTE: Please notify your sales representative if any of the above items are missing or damaged.

Hardware Introduction

NPort 6150

- 2 -

NPort 6250

LED Name
LED Color
LED Function
PWR
Red
Power is being supplied to the power input.
Steady on
Power is on and the NPort is booting up.
occurred. Check the relay
output first. If after resolving the
server did not respond properly.
Steady on
Power is on and the NPort is functioning normally.
Blinkin g
The device server has been
Location function.
Off
Power is off, or power error condition exists.
Reset Button—Press the Reset Button continuously for 5 sec to load factory defaults. Use a pointed object, such as a straightened paper clip or toothpick, to press the reset button. This will cause the Ready LED to blink on and off. The factory defaults will be loaded once the Ready LED stops blinking (after about 5 seconds). At this point, you should release the reset button.

LED Indicators

Blinkin g Indicates an IP conflict, or, the
Red
Ready
Green
DHCP or BOOTP server did not respond properly or a relay output
relay output the RDY LED is still blinking, then there is an IP conflict, or the DHCP or BOOTP
located by the Administrator’s
- 3 -
LED Name
LED Color
LED Function
Link
Orange
10 Mbps Ethernet connection
Green
100 Mbps Ethernet connection
Off
Ethernet cable is disconnected, or has a short.
Orange
Serial port is rece iving data.
Green
Serial port is transmitting data.
No data is being transmitted or received through the serial port.
software.
Serial port has not been opened by server side software.
Jumpers are used to set the pull high/low
resistors. The default is 150 kΩ. Short th e ju mpe rs to set th is va lu e to 1 kΩ. Do not use the 1 kΩ setting with RS
mode, since doing so will degrade the RS communication distance.
STEP 1:
Connect the 12-48 VDC power adaptor to the NPort 6150 and then plug the power adaptor into a DC outlet.
STEP 2:
For first-time configuration, use a cross-over Ethernet cable to connect the NPort cable. For connecting to a network, use a standard straight-through Ethernet cable to connect to a hub or switch.
STEP 3:
Connect the NPort 6150’s serial port to a serial device.
Wallmount
Din Rail
P1, P2
Off
P1, P2
in-use LED
Green
Serial port was opened by server side
Off

Adjustable pull high/low resistor for RS-422/485 (150 KΩ or 1 KΩ)

-232
-232 signals and shorten the

Hardware Installation Procedure

6150 directly to your computer’s Ethernet

Placement Options

The NPort 6150/6250 can be placed flat on a desktop or other horizontal surface. In addition, you may use the DIN-rail or wallmount options, as illustrated below.
- 4 -

Software Installation Information

RS-422
4-wire RS-485
2-wire
RS-485
1
DCD
TxD-(A)
– 2 RXD
TxD+(B)
– 3 TXD
RxD+(B)
Data+(B)
4
DTR
RxD-(A)
Data-(A)
5
GND
GND
GND
6
DSR – – 7 RTS – – 8 CTS – – 9 – – –
The Documentation and software CD contains the user’s manual, NPort Search Utility, and the PComm Lite Suite. Insert the CD into your computer’s CD-ROM drive and follow the on-screen instructions. Please refer to the user’s manual for additional details on using the NPort Search Utility and PComm Lite.

Pin Assignments and Cable Wiring

RS-232/422/485 Pin Assignment (male DB9)

Pin RS-232
Two serial cables for connecting the NPort 6150 to a serial device can be purchased separately. The wiring diagrams for the two cables are shown below.
- 5 -