Overview

Introduction
The ICF-1170I series is a CAN-to-fiber optic converter that secures data transmission by using fiber optic transmission to provide complete isolation and protection against EMI.
The ICF-1170I series can separate and protect critical segments of the system from the rest of the CAN network and is protocol independent, allowing it to work with all of the different CAN protocols and frame lengths.
To connect two CAN devices with fiber optic cable, two ICF-1170I series converters are required.
Why Convert CAN to Fiber?
IMMUNITY FROM ELECTRICAL INTERFERENCE Fiber is not affected by electromagnetic interference or radio frequency interference; consequently it provides a clean communication path and is immune to crosstalk.
INSULATION Optical fiber is an insulator; the glass fiber eliminates the need for using electric current as the communication medium.
SECURITY Optical fiber provides better security compared to traditional electrical signals transmitted through a wire or radio waves transmitted through the air. Since the light rays travel down the center of the fiber, it is extremely difficult for them to escape. In addition, it is nearly impossible to tap into a fiber optic cable, and even if a tap is successful, it is possible to detect the tap by monitoring the optical power received at the termination point.
RELIABILITY AND MAINTENANCE Fiber is immune to adverse temperature and moisture conditions, does not corrode or lose its signal, and is not affected by short circuits, power surges, or static electricity.
Fiber Test Mode
The ICF-1170I supports a special feature ca lled Fiber Test Mode, which is easily activated with a DIP switch on the ICF-1170I’s outer panel.
Fiber Test Mode can be used to test the fiber cable between two ICF-1170I units and provides a simple way to determine if the fiber cable is transmitting data correctly.
When in Fiber Test Mode, the fiber transceiver (TX) will send out a data signal continuously and the “Fiber TX” LED will light u p. On the other side of the connection, when the ICF-1170I fiber transceiver (RX) receives the data signal form the TX side, the “Fiber RX” LED will light up.
- 2 -
Alarm Contact Output
The ICF-1170I supports dual power inputs for r edundancy. When one power input fails, the relay will be triggered. Be sure to install the dual power inputs for the ICF-1170I series, and choose the correct relay output when connecting the alarm.

Features

• Transmission distance up to 2 km
• Convert CAN signals to fiber and fiber to CAN signals
• CAN transfer rate up to 1 Mbps
• Dual power inputs for redundancy
• DIP switch for 120 Ω terminal resistance
• DIP switch for fiber test mode
• Wide temperature range model available for -40 to 85°C environments

Package Checklist

Before installing the ICF-1170I series, verify that the package contains the following items:
• ICF-1170I series CAN-to-fiber Converter
• Quick Installation Guide (printed)
• Warranty card
NOTE: Please notify your sales representative if any of the above items
are missing or damaged.
- 3 -

Mounting Dimensions (Unit: mm)

ICF-1170I-M-ST
Top View
Front View
- 4 -
ATTENTION
Electrostatic Discharge
To protect the product from damage due to electrostatic discharge, we recommend wearing a grounding device when handling your ICF-1170 series.
Step 1:
Insert the top of the DIN the slot spring.
Step 2:
The DIN snap into place as shown below
ST-Port Pinouts
ST-Port to ST-Port Cable Wiring
ATTENTION
This is a Class 1 laser/LED product. Do not stare into the laser beam.
Warning!

Mounting

The aluminum DIN-rail attachment plate should be fixed to the back panel of the ICF-1170I series when you take it out of the box. If you need to reattach the DIN-rail attachment plate to the ICF-1170I, make sure the stiff metal spring is situated towards the top, as shown in the figures below.
just below the stiff metal
-rail into
-rail attachment unit will
To remove the ICF-1170I series from the DIN-rail, simply reverse Steps 1 and 2 above.

Fiber Cable

- 5 -
120 Ω Terminator
Switch 1
Enable
ON
Disable
OFF (default)
Fiber Test Mode
Switch 2
Enable
ON
Disable
OFF (default)
LED
Color
Function
PWR 1
Green
Steady ON: Power source 1 is ON.
PWR 2
Green
Steady ON: Power source 2 is ON.
Fiber Tx
Green
When sending CAN data to the fiber port.
Fiber Rx
Orange
When receiving CAN data from the fiber port.
CAN Communication
CAN_GND)
Protocols Supported
CAN 2.0A and 2.0B (ISO 11898-2)
CAN Connector
3-pin removable screw terminal x1
Termination Resistor
Dip switch selector for 120 Ω terminal resistor
Baudrate
Up to 1 Mbps
System Delay
150 ns
Isolation Protection
2 KV
Transmission Length
Max. 2 KM (depends on the data rate and the
Baud Rate
Fiber Length
1000 kbps
10 m
500 kbps
100 m
250 kbps
250 m
125 kbps
400 m
50 kbps
1000 m
10 kbps
2000 m
Note: CAN Bus cable length is 30 m.

LED Indicators

PWR1, PWR2, Fiber TX, Fiber RX
mentioned in the ISO 11898-2 standard.

Switch Settings

There are two DIP switches on the front panel of the ICF-1170I series.
LED Indicators
There are 4 LEDs on the front panel of the ICF-1170I.

Typical CAN Application

Specifications

CAN Bus Interface ISO 11898-2, Terminals (CAN_H, CAN_L,
protocol used)
Note: The transmission distance is limited by the signal rate, as
- 6 -
Fiber Communication
Connector Type
ST (multimode) fiber ports x 2
Support Cable
50/125, 62.5/125, or 100/140 μm (multimode)
Wavelength
850 nm
TX Output
> -5 dBm
RX Sensitivity
-20 dBm
Environmental Limits
Operating Temperature
0 to 60°C (32 to 140°F), 5 to 95 % RH
-40 to 85°C (-40 to 185°F) for -T model
Storage Temperature
-40 to 85°C (-40 to 185°F), 5 to 95 % RH
Power
Input Power Voltage
12 to 48 VDC dual power input for redundancy
Alarm contact
1 normal open/close output with current-carrying capacity of 1 A@24VDC
Mechanical Specifications
Dimensions
30.3 × 70 × 115 mm
Material
Aluminum (1 mm)
Gross Weight
135 g
Regulatory Approvals
CE
Class A
FCC
Part 15 sub Class A
UL
UL-508
LVD
EN 60950-1
EMI
EN55032 1998, Class A
En61000-4-8 (PFMF), Criteria A, Level 3
Freefall
IEC 60068-2-32
MTBF
792085 hrs.
CAN connector.
ICF-1170I-M-ST-T:
CAN-to-fiber converter, multimode, ST connector, -40 to 85°C.
EMS EN61000-4-2 (ESD), Criteria B, Level 4
EN61000-4-3 (RS), Criteria A, Level 2 EN61000-4-4 (EFT), Criteria B, Level 4 EN61000-4-5 (Surge), Criteria B, Level 2 EN61000-4-6 (CS), Criteria B, Level 2

Ordering Information

Available models:
ICF-1170I-M-ST:
-to-fiber converter, multimode, ST