• 10/100BaseT(X) (RJ45 connector), 100BaseFX (multi/single-mode, SC or ST
connector)
• Redundant dual 12/24/48 VDC power inputs
• IP30 aluminum housing
• Rugged hardware design well suited for hazardous locations (Class 1 Div. 2/
ATEX Zone 2), transportation (NEMA TS2/EN 50121-4), and maritime
environments (DNV/GL/LR/ABS/NK)
• -40 to 75°C operating temperature range (-T models)
Certifications
Introduction
The EDS-205A Series 5-port industrial Ethernet switches support IEEE 802.3 and IEEE 802.3u/x with 10/100M full/half-duplex, MDI/MDI-X autosensing. The EDS-205A Series has 12/24/48 VDC (9.6 to 60 VDC) redundant power inputs that can be connected simultaneously to live DC power
sources. These switches have been designed for harsh industrial environments, such as in maritime (DNV/GL/LR/ABS/NK), rail wayside, highway,
or mobile applications (EN 50121-4/NEMA TS2/e-Mark), or hazardous locations (Class I Div. 2, ATEX Zone 2) that comply with FCC, UL, and CE
standards.
The EDS-205A switches are available with a standard operating temperature range from -10 to 60°C, or with a wide operating temperature range
from -40 to 75°C. All models are subjected to a 100% burn-in test to ensure that they fulfill the special needs of industrial automation control
applications. In addition, the EDS-205A switches have DIP switches for enabling or disabling broadcast storm protection, providing another level of
flexibility for industrial applications.
All models support:
Auto negotiation speed
Full/half duplex mode
Auto MDI/MDI-X connection
1
Page 2
www.moxa.com
StandardsIEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3x for flow control
Optical Fiber
100BaseFX
Multi-ModeSingle-Mode
Fiber Cable TypeOM1
Typical Distance4 km5 km40 km
Wavelength
Optical Power
Typical (nm)13001310
TX Range (nm)1260 to 13601280 to 1340
RX Range (nm)1100 to 16001100 to 1600
TX Range (dBm)-10 to -200 to -5
RX Range (dBm)-3 to -32-3 to -34
Link Budget (dB)1229
Dispersion Penalty
(dB)
50/125 µm
G.652
800 MHz x km
31
Note: When connecting a single-mode fiber transceiver, we recommend using an
attenuator to prevent damage caused by excessive optical power.
Note: Compute the “typical distance” of a specific fiber transceiver as follows: Link
budget (dB) > dispersion penalty (dB) + total link loss (dB).
Switch Properties
MAC Table Size1 K
Packet Buffer Size384 kbits
Processing TypeStore and Forward
Power Parameters
Connection1 removable 4-contact terminal block(s)
Input CurrentEDS-205A/205A-T: 0.09 A @ 24 VDC
EDS-205A-M-SC/M-ST/S-SC Series: 0.1 A @ 24 VDC
Input Voltage12/24/48 VDC, Redundant dual inputs
Operating Voltage9.6 to 60 VDC
Overload Current ProtectionSupported
Reverse Polarity ProtectionSupported
DIP Switch Configuration
Ethernet InterfaceBroadcast storm protection
Physical Characteristics
HousingAluminum
IP RatingIP30
Dimensions30 x 115 x 70 mm (1.18 x 4.52 x 2.76 in)
This document and any portion thereof may not be reproduced or used in any manner whatsoever without the express written permission of
Moxa Inc. Product specifications subject to change without notice. Visit our website for the most up-to-date product information.
5
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.