The software described in this manual is furnished under a license agreement and may be used only in
accordance with the terms of that agreement.
Copyright Notice
Copyright 2004 Moxa Technologies Co., Ltd.
All rights reserved.
Reproduction without permission is prohibited.
Trademarks
MOXA is a registered trademark of Moxa Technologies Co., Ltd.
All other trademarks or registered marks in this manual belong to their respective manufacturers.
Disclaimer
Information in this document is subject to change without notice and does not represent a commitment on the
part of Moxa.
Moxa provides this document “as is,” without warranty of any kind, either expressed or implied, including, but
not limited to, its particular purpose. Moxa reserves the right to make improvements and/or changes to this
manual, or to the products and/or the programs described in this manual, at any time.
Information provided in this manual is intended to be accurate and reliable. However, Moxa Technologies
assumes no responsibility for its use, or for any infringements on the rights of third parties that may result from
its use.
This product might include unintentional technical or typographical errors. Changes are periodically made to the
information herein to correct such errors, and these changes are incorporated into new editions of the
publication.
Revision History .....................................................................................D-5
Appendix E Auto IP Report Protocol ................................................................. E-1
1
1
Chapter 1 Introduction
Welcome to the MOXA NPort 5600 Series of advanced serial device servers that make it easy to
network-enable your serial devices. The NPort 5600 Series has 8 models: NPort 5610-16, NPort
5610-8 (16/8 ports for RS-232, with AC power), NPort 5610-16-48V, NPort 5610-8-48V (16/8
ports for RS-232, with DC power), NPort 5630-16, NPort 5630-8 (16/8 ports for RS-422/485,
with AC power), NPort 5630-16-48V, NPort 5630-8-48V (16/8 ports for RS-422/485, with DC
power). In this manual, we often refer to the four products collectively as “5600” or “5600
Series.”
The following topics are covered in this chapter:
Overview
Package Checklist
Product Features
Product Specifications
Overview
NPort 5600 Series serial device servers are designed to make your industrial serial devices
Internet ready instantly. The compact size of NPort 5600 device servers makes them the ideal
choice for connecting your RS-232 (NPort 5610-16/8) or RS-422/485 (NPort 5630-16/8) serial
devices—such as PLCs, meters, and sensors—to an IP-based Ethernet LAN, making it possible
for your software to access serial devices anywhere over a local LAN or the Internet.
NPort 5600 serial device servers ensure the compatibility of network software that uses a standard
network API (Winsock or BSD Sockets) by providing TCP Server Mode, TCP Client Mode, and
UDP Mode. And thanks to NPort’s Real COM/TTY drivers, software that works with COM/TTY
ports can be set up to work over a TCP/IP network in no time. This excellent feature preserves
your software investment and lets you enjoy the benefits of networking your serial devices
instantly.
NPort 5600 serial device servers support automatic IP configuration protocols (DHCP, BOOTP)
and manual configuration via NPort’s handy web browser console. Both methods ensure quick
and effective installation. And with NPort 5600’s Windows Utility, installation is very
straightforward, since all system parameters can be stored and then copied to other device servers
simultaneously.
Package Checklist
MOXA NPort 5600 Series products are shipped with the following items:
Standard Accessories
1 16- or 8-port serial device server
NPort Documentation & Software CD
NPort 5600 Quick Installation Guide
Power cord
Optional Accessories
CBL-RJ45M9-150 RJ45 8-pin to DB9 Male cable, 150 cm
CBL-RJ45F9-150 RJ45 8-pin to DB9 Female cable, 150 cm
CBL-RJ45M25-150 RJ45 8-pin to DB25 Male cable, 150 cm
CBL-RJ45F25-150 RJ45 8-pin to DB25 Female cable, 150 cm
NOTE: Notify your sales representative if any of the above items is missing or damaged.
Product Features
NPort 5600 Series products have the following features:
Make your serial devices Internet ready
Easy-to-use LCM (Liquid Crystal Module) interface for setting up the IP address
Versatile socket operation modes, including TCP Server, TCP Client, and UDP
Easy-to-use Windows Utility for mass installation
Supports 10/100 Mbps Ethernet—auto-detectable
Supports 16/8-port RS-232 or RS-422/485 interface
Built-in 15 KV ESD protection for all serial signals
Supports SNMP MIB-II for network management
1-2
NPort 5600 Series User’s Manual
Product Specifications
LAN
Ethernet 10/100 Mbps, RJ45
Protection Built-in 1.5 KV magnetic isolation
NPort 5610 Serial Interface
Interface RS-232
No. of Ports 16/8
Port Type RJ45 8-pin
Signals TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
Serial Line Protection 15 KV ESD for all signals
NPort 5630 Serial Interface
Interface RS-422/485
No. of Ports 16/8
Port Type RS45 8-pin
Signals RS-422: Tx+, Tx-, Rx+, Rx-, GND
RS-485 (2-wire): Data+, Data-, GND
RS-485 (4-wire): Tx+, Tx-, Rx+, Rx-, GND
Serial Line Protection 15 KV ESD for all signals
RS-485 Data Direction ADDC™ (Automatic Data Direction Control)
Power Line Protection
4 KV Burst (EFT), EN61000-4-4
2 KV Surge, EN61000-4-5
Advanced Built-in Features
HMI LCM display with four push buttons
Buzzer
Real-Time Clock
Watch Dog Timer
Serial Communication Parameters
Parity None, Even, Odd, Space, Mark
Data Bits 5, 6, 7, 8
Stop Bit 1, 1.5, 2
Flow Control RTS/CTS, XON/XOFF
Transmission Speed 50 bps to 115.2 Kbps
Utilities NPort Administrator for Windows 95/98/ME/NT/2000/XP
Real COM/TTY Drivers Windows 95/98/ME/NT/2000/XP Real COM driver, Linux
Configuration Web Browser, Telnet Console, or Windows Utility
Introduction
SNMP, HTTP, SMTP, SNTP
real TTY driver
NPort 5600 Series User’sManual
1-3
Power Requirements
Power Input 100 to 240 VAC, 47 to 63 Hz, or 48 VDC
Power Consumption NPort 5610-8/16: 200 mA for 100V, 130 mA for 240V
NPort 5610-8/16-48V: 190 mA (at 48V max.)
NPort 5630-8/16: 212 mA for 100V, 130 mA for 240V
NPort 5630-8/16-48V: 215 mA (at 48V max.)
Mechanical
Material SECC sheet metal (1 mm)
Dimensions (W × H × D) 190 × 44.5 × 478 mm (including ears)
190 × 44.5 × 440 mm (without ears)
Environment
Operating Temperature 0 to 55°C (32 to 131°F), 5 to 95%RH
Storage Temperature -20 to 85°C (-4 to 185°F), 5 to 95%RH
Regulatory Approvals
EMC FCC Class A, CE Class A
Safety UL, CUL, TÜV
WARRANTY 5 years
1-4
NPort 5600 Series User’s Manual
2
2
Chapter 2 Getting Started
This chapter includes information about installing NPort 5600 Series. The following topics are
covered:
Panel Layout
Connecting the Hardware
Wiring Requirements
Connecting NPort 5610/30-16/8’s Power
Connecting NPort 5610/30-16/8-48V’s Power
Grounding NPort 5610/30-16/8-48V
Connecting to the Network
Connecting to a Serial Device
LED Indicators
Panel Layout
Front panel of NPort 5610-16-48V
Font panel of NPort 5630-16
Rear panel of NPort 5610-16 (AC Power)
Rear panel of NPort 5610-16 -48V (DC Power)
Reset Button—Press the Reset button continuously for 5 sec to load factory defaults
pointed object, such as a straightened paper clip or toothpick, to press the reset button. This will
cause the Ready LED to blink on and off. The factory defaults will be loaded once the Ready LED
stops blinking (after about 5 seconds). At this point, you should release the reset button.
: Use a
2-2
NPort 5600 Series User’s Manual
Connecting the Hardware
This section describes how to connect NPort 5600 Series to serial devices for first time testing
purposes. We cover Wiring Requirements, Connecting NPort 5610/30-16/8’s Power,
Connecting NPort 5610/30-16/8-48V’s Power, Grounding NPort 561/30-16/8-48V,
Connecting to the Network, Connecting to a Serial Device, and LED Indicators.
Wiring Requirements
Be sure to disconnect the power cord before installing and/or wiring your NPort 5600.
Calculate the maximum possible current in each power wire and common wire. Observe all electrical
codes dictating the maximum current allowable for each wire size.
If the current goes above the maximum ratings, the wiring could overheat, causing serious damage to
your equipment.
Getting Started
Safety First!
Wiring Caution!
Temperature Caution!
Please take care when handling NPort 5600. When plugged in, NPort 5600’s internal components
generate heat, and consequently the casing may feel hot to the touch.
You should also pay attention to the following points:
Use separate paths to route wiring for power and devices. If power wiring and device wiring
paths must cross, make sure the wires are perpendicular at the intersection point.
NOTE: Do not run signal or communication wiring and power wiring in the same wire
conduit. To avoid interference, wires with different signal characteristics should be routed
separately.
You can use the type of signal transmitted through a wire to determine which wires should be
kept separate. The rule of thumb is that wiring that shares similar electrical characteristics can
be bundled together.
Keep input wiring and output wiring separate.
Where necessary, it is strongly advised that you label wiring to all devices in the system.
Connecting NPort 5610/30-16/8’s Power
Connect NPort 5610/30-16/8’s 100-240 VAC power line with its AC connector. If the power is
properly supplied, the “Ready” LED will show a solid red color until the system is ready, at which
time the “Ready” LED will change to a green color.
NPort 5600 Series User’sManual
2-3
Connecting NPort 5610/30-8/16-48V’s Power
To connect NPort 5610/30-8/16-48V’s power cord with its terminal block, follow the steps given
below:
and V- terminals of NPort 5610/30-8/16-48V’s terminal
+
NOTE
1. Loosen the screws on the V
block.
2. Connect the power cord’s 48 VDC wire to the terminal block’s V
power cord’s DC Power Ground wire to the terminal block’s V- terminal, and then
tighten the terminal block screws. (Note: NPort 5610/30-8/16-48V can still operate
even if the DC 48V and DC Power Ground are reversed.)
If the power is properly supplied, the “Ready” LED will show a solid red color until the system is
ready, at which time the “Ready” LED will change to a green color.
You should use 8 kg-cm of screw torque and 22-14 AWG of suitable electric wire to connect NPort
5610/30-8/16-48V’s power cord to its terminal block.
Grounding NPort 5610/30-16/8-48V
Grounding and wire routing helps limit the effects of noise due to electromagnetic interference
(EMI). Run the ground connection from the ground screw to the grounding surface prior to
connecting devices.
The Shielded Ground (sometimes called Protected Ground) contact is
the second contact from the right of the 5-pin power terminal block
connector located on the rear panel of NPort
5610-16-48V/5610-8-48V. Connect the SG wire to the Earth ground.
terminal, and the
+
This product is intended to be mounted to a well-grounded mounting surface such as a metal panel.
Connecting to the Network
Connect one end of the Ethernet cable to NPort 5600’s 10/100M Ethernet port and the other end
of the cable to the Ethernet network. There are 2 LED indicators located on the bottom left and
right corners of the Ethernet connector. If the cable is properly connected, NPort 5600 will
indicate a valid connection to the Ethernet in the following ways:
The bottom right corner LED indicator maintains a solid green color when the cable is
properly connected to a 100 Mbps Ethernet network.
The bottom left corner LED indicator maintains a solid orange color when the cable is
properly connected to a 10 Mbps Ethernet network.
2-4
NPort 5600 Series User’s Manual
Connecting to a Serial Device
Connect the serial data cable between NPort 5600 and the serial device.
LED Indicators
The front panels of NPort 5600 have severalLED indicators, as described in the following table.
LED Name LED Color LED Function
off Power is off, or power error condition exists.
Getting Started
Steady on: Power is on and NPort is booting up.
Ready
1-16
Real Time Clock
NPort 5600’s real time clock is powered by a lithium battery. We strongly recommend that you do
not replace the lithium battery without the presence of Moxa’s technical support engineers. If you
need a battery change, contact Moxa for assistance.
There is risk of explosion if the battery is replaced by an incorrect type. You need to dispose used
batteries according to the instructions.
red
green
orange Serial port is receiving data.
green Serial port is transmitting data.
off
Blinking:
Steady on: Power is on and NPort is functioning normally.
Blinking:
No data is being transmitted or received through the serial
port.
Indicates an IP conflict, or DHCP or BOOTP
server did not respond properly.
The NPort has been located by NPort
Administrator’s Location function.
NPort 5600 Series User’sManual
2-5
3
3
Chapter 3 Initial IP Address Configuration
When setting up your NPort 5600 for the first time, the first thing you should do is configure the
IP address. This chapter introduces several methods to configure NPort’s IP address. Select the
method that is the most convenient for you. For more details about network settings, see the
Network Settings section from Chapter 5, Web Console Configuration.
This chapter includes the following sections:
Initializing NPort’s IP Address
Factory Default IP Address
LCM Display recommended configuration method
NPort Administration Suite recommended configuration method
ARP
Telnet Console
Initializing NPort’s IP Address
1. Determine whether your NPort needs to use a Static IP or Dynamic IP (either DHCP or
BOOTP application).
2. If NPort is used in a Static IP environment, you can use NPort Administration Suite, ARP,
Web Console, or Telnet Console to configure the new IP address.
3. If NPort is used in a Dynamic IP environment, you can use NPort Administration suite,
Web Console, or Telnet Console to configure NPort to get an IP address dynamically with
DHCP, DHCP/BOOTP, or BOOTP.
Consult your network administrator on how to reserve a fixed IP address (for your NPort) in the
MAC-IP mapping table when using a DHCP Server or BOOTP Server. In most applications, you
should assign a fixed IP address to your NPort.
Factory Default IP Address
NPort products are configured with the following default private IP address:
Default IP address: 192.168.127.254
(IP addresses of the form 192.168.xxx.xxx are referred to as private IP addresses, since it is not
possible to directly access a device configured with a private IP address from a public network.
For example, you would not be able to ping such a device from an outside Internet connection.
NPort applications that require sending data over a public network, such as the Internet, require
setting up the server with a valid public IP address, which can be leased from a local ISP.)
LCM Display
We recommend using the LCM display and four push buttons to configure the IP address for the
first time.
Basic Operation
If the NPort is working properly, the LCM panel will display a green color. The red Ready LED
will also light up, indicating that the NPort is receiving power. After the red Ready LED turns
green, you will see a display similar to:
There are four push buttons on NPort’s nameplate. Going from left to right, the buttons are:
Button Name
MENUmenu activates the main menu, or returns to an upper level
U
V
SEL
up cursor
down cursor
select
Action
scrolls up through a list of items shown on the LCM panel’s second line
scrolls down through a list of items shown on the LCM panel’s second
line
selects the option listed on the LCM panel’s second line
The buttons are manipulated in a manner similar to the way a modern cellular phone operates. As
you move through the various functions and setting options, note that the top line shows the
current menu or submenu name, and the bottom line shows the submenu name or menu item that
is activated by pressing the SEL button.
Detailed Menu Options
The best way to explain all of NPort’s LCM functions is to refer to the table shown on the next
page. There are three main levels—1, 2, and 3—with each level represented by a separate column.
The first thing to remember is that the MENU button is used to move back and forth between the
LCM panel’s default screen, and main menu screen:
• Use the SEL button to move up one level (i.e., left to right on the tree graph)
• Use the MENU button to move down one level (i.e., right to left on the tree graph)
• Use the cursor keys, U and V, to scroll between the various options within a level (i.e.,
up and down on the tree graph).
NPort 5600 Series User’sManual
3-3
As you use the buttons to operate the LCM display, you will notice that with very few
exceptions, moving up one level causes the bottom line of the display to move to the top
line of the display. You will also notice that the bottom three options in level 2, and all of
the options in level 3 have either a C or D attached.
The meaning is as follows:
• C = configurable
I.e., you are allowed to change the setting of this option
• D = display only
I.e., the setting for this option is displayed, but it cannot be changed (this does
NOT necessarily mean that the number doesn’t change; only that you can’t change
it)
Level 1 Level 2 Level 3
Main Menu
Server
setting
Network
setting
Serial set Select port
Op Mode set
Console Web console
Ping C
Save/Restart C
Serial number
Server name
Firmware ver
Model name
Ethernet status
MAC address
IP config
IP address
Netmask
Gateway
DNS server 1
DNS server 2
Baud rate
Data bit
Stop bit
Parity
Flow control
Tx/Rx fifo
Interface
Tx/Rx bytes
Line status
Select port
Select mode
[mode]
Real COM
Alive timeout
Max connection
Delimiter 1
Delimiter 2
Force Tx
Telnet console
TCP server
Alive timeout
Inact. time
Max connection
Delimiter 1
Delimiter 2
Force Tx
Local TCP port
Command port
TCP client
Alive timeout
Inact. time
Delimiter 1
Delimiter 2
Force Tx
Dest IP-1
TCP port-1
Dest IP-2
TCP port-2
Dest IP-3
TCP port-3
Dest IP-4
TCP port-4
TCP connect
UDP svr/cli
Delimiter 1
Delimiter 2
Force Tx
Dest IP start-1
Dest IP end-1
Dest port-1
Dest IP start-2
Dest IP end-2
Dest port-2
Dest IP start-3
Dest IP end-3
Dest port-3
Dest IP start-4
Dest IP end-4
Dest port-4
Local port
D
C
D
D
D
D
C
C
C
C
C
C
C
C
C
C
C
C
C
C
D
D
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
3-4
NPort 5600 Series User’s Manual
Initial IP Address Configuration
The part of the LCM operation that still requires some explanation is how to edit the
configurable options. In fact, you will only encounter two types of configurable options.
The first type involves entering numbers, such as IP addresses, Netmasks, etc. In this case,
you change the number one digit at a time. The up cursor (U) is used to decrease the
highlighted digit, the down cursor (V) is used to increase the highlighted digit, and the sel
button is used to move to the next digit. When the last digit has been changed, pressing sel
simply enters the number into NPort 5600 Series’ memory.
The second type of configurable option is when there are only a small number of options
from which to choose (although only one option will be visible at a time). Consider the
Parity attribute under Serial set as an example. Follow the tree graph to arrive at the
following Parity screen. The first option, None, is displayed, with a down arrow all the
way to the right. This is an indication that there are other options from which to choose.
P a r i t Y
N O n e
Press the down cursor button once to see Odd as the second option.
P a r i t Y
O d d
Press the down cursor button again to see Even as the third option.
P A R I T Y
E v e n
Press the down cursor button again to see Space as the fourth option.
P A R I T Y
S p a c e
Press the down cursor button yet again to see the last option, Mark.
P A R I T Y
M a r k
To choose the desired option, press the SEL button when the option is showing on the screen.
↓
↑
↓
↑
↓
↑
↓
↑
NPort Administration Suite
NPort Administration Suite consists of some useful utility programs that are used to configure and
manage your NPorts.
See Chapter 6 for details on how to install NPort Administration Suite, and how to use this
suite of useful utilities to set up IP addresses and configure your NPort.
ARP
You can make use of the ARP (Address Resolution Protocol) command to set up an IP address for
your NPort. The ARP command tells your computer to associate the NPort’s MAC address with
the intended IP address. You must then use Telnet to access the NPort, at which point the Device
Server’s IP address will be reconfigured.
In order to use this setup method, both your computer and NPort must be connected to the same LAN.
Or, you may use a cross-over Ethernet cable to connect the NPort directly to your computer’s Ethernet
card.
Your NPort must be configured with the factory default IP address—192.168.127.254—before
executing the ARP command, as described below.
NPort 5600 Series User’sManual
3-5
Take the following steps to use ARP to configure the IP address:
1. Obtain a valid IP address for your NPort from your network administrator.
2. Obtain the NPort’s MAC address from the label on its bottom panel.
3. Execute the ‘arp -s’ command from your computer’s MS-DOS prompt by typing:
This is where 192.168.200.100 is the new IP address and 00-90-E8-xx-xx-xx is the MAC address
for your NPort. You will need to change both numbers, as described above in points 1 and 2.
4. Next, execute a special Telnet command by typing:
telnet 192.168.200.100 6000
After issuing this command, a Connect failed message
will appear, as shown here. After the NPort reboots, its IP
address should be updated to the new address, and you
can reconnect using either Telnet, Web, or Administrator
to check that the update was successful.
Telnet Console
Depending on how your computer and network are configured, you may find it convenient to use
network access to set up your NPort’s IP address. This can be done using the Telnet program.
arp –s 192.168.200.100 00-90-E8-xx-xx-xx
Figures in this section will use 5610-8 as an example.
1. From the Windows desktop, click on Start and then select Run.
2. Type telnet 192.168.127.254 (use the
correct IP address if different from the default) in
the Open text input box, and then click OK.
3. When the Telnet window opens, if you are prompted to
input the Console password, input the password and then
press Enter.
Note that this page will only appear if the NPort is
password protected.
4. Type 2 to select Network settings, and then press
Enter.
3-6
NPort 5600 Series User’s Manual
5. Type 1 to select IP address and then press Enter.
6. Use the Backspace key to erase the current IP
address, type in the new IP address, and then press
Enter.
Initial IP Address Configuration
7. Press any key to continue…
8. Type m or M and then press Enter to return to the
main menu.
NPort 5600 Series User’sManual
3-7
9. Type s or S and then press Enter to Save/Restart
the system.
10. Type y or Y and then press Enter to save the new
IP address and restart NPort.
3-8
NPort 5600 Series User’s Manual
Chapter 4 Choosing the Proper Operation Mode
In this section, we describe the various NPort operation modes. The options include an operation
mode that uses a driver installed on the host computer, and operation modes that rely on TCP/IP
socket programming concepts. After choosing the proper operating mode in this chapter, refer to
Chapter 5 for detailed configuration parameter definitions.
Overview
4
4
TCP Server Mode
TCP Client Mode
UDP Mode
Real COM Mode
Overview
NPort Device Servers network-enable traditional RS-232/422/485 devices, in which a Device
Server is a tiny computer equipped with a CPU, real-time OS, and TCP/IP protocols that can
bi-directionally translate data between the serial and Ethernet formats. Your computer can access,
manage, and configure remote facilities and equipment over the Internet from anywhere in the
world.
Traditional SCADA and data collection systems rely on serial ports (RS-232/422/485) to collect
data from various kinds of instruments. Since NPort Serial Device Servers network-enable
instruments equipped with an RS-232/422/485 communication port, your SCADA and data
collection system will be able to access all instruments connected to a standard TCP/IP network,
regardless of whether the devices are used locally or at a remote site.
NPort is an external IP-based network device that allows you to expand the number of serial ports
for a host computer on demand. As long as your host computer supports the TCP/IP protocol, you
won’t be limited by the host computer’s bus limitation (such as ISA or PCI), or lack of drivers for
various operating systems.
In addition to providing socket access, NPort also comes with a Real COM/TTY driver that
transmits all serial signals intact. This means that your existing COM/TTY-based software can be
preserved, without needing to invest in additional software.
In addition to providing socket access, as long as your host computer supports the TCP/IP
protocol, you won’t be limited by the host computer’s bus limitation (such as ISA or PCI), or lack
of drivers for various operating systems.
Three different Socket Modes are available: TCP Server, TCP Client, and UDP Server/Client. The
main difference between the TCP and UDP protocols is that TCP guarantees delivery of data by
requiring the recipient to send an acknowledgement to the sender. UDP does not require this type
of verification, making it possible to offer speedier delivery. UDP also allows multicasting of data
to groups of IP addresses.
TCP Server Mode
In TCP Server mode, NPort provides a unique IP:Port
address on a TCP/IP network. NPort waits passively to
be contacted by the host computer, allowing the host
computer to establish a connection with and get data
from the serial device. This operation mode also
supports up to 4 simultaneous connections, so that
multiple hosts can collect data from the same serial
device—at the same time.
As illustrated in the figure, data transmission proceeds
as follows:
1. The host requests a connection from the NPort
configured for TCP Server Mode.
2. Once the connection is established, data can be
transmitted in both directions—from the host to
the NPort, and from the NPort to the host.
4-2
NPort 5600 Series User’s Manual
TCP Client Mode
In TCP Client mode, NPort can actively establish a
TCP connection to a pre-defined host computer
when serial data arrives.
After the data has been transferred, NPort can
automatically disconnect from the host computer by
using the TCP alive check time or Inactivity time
settings. Refer to Chapter 5 for more details
As illustrated in the figure, data transmission
proceeds as follows:
1. The NPort configured for TCP Client Mode
requests to connect to the host.
2. Once the connection is established, data can be
transmitted in both directions—from the host to
the NPort, and from the NPort to the host.
UDP Mode
Choosing the Proper Operation Mode
Compared to TCP communication, UDP is faster
and more efficient. In UDP mode, you can
unicast or multicast data from the serial device to
one or multiple host computers, and the serial
device can also receive data from multiple host
computers, making this mode ideal for message
display applications.
Real COM Mode
NPort comes equipped with COM drivers that work
with Windows 95/98/ME/NT/2000/XP systems, and
also TTY drivers for Linux systems. The driver
establishes a transparent connection between host and
serial device by mapping the IP:Port of the NPort’s
serial port to a local COM/TTY port on the host
computer. This operation mode also supports up to 4
simultaneous connections, so that multiple hosts can
collect data from the same serial device at the same
time.
The driver used for Real COM Mode comes with the NPort Windows Administrator which will
install automatically on your computer when you install NPort Administration Suite.
NPort 5600 Series User’sManual
4-3
The important point is that Real COM Mode allows users to continue using RS-232/422/485 serial
communications software that was written for pure serial communications applications. The driver
intercepts data sent to the host’s COM port, packs it into a TCP/IP packet, and then redirects it
through the host’s Ethernet card. At the other end of the connection, the NPort accepts the
Ethernet frame, unpacks the TCP/IP packet, and then transparently sends it to the appropriate
serial device attached to one of the NPort’s serial ports.
Real COM Mode allows several hosts to have access control of the same NPort. The Moxa driver that
comes with your NPort controls host access to attached serial devices by checking the host’s IP
address.
Refer to Accessible IP Settings in Chapter 5 for more details.
4-4
NPort 5600 Series User’s Manual
Loading...
+ 64 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.