Connect your 12 to 48 VDC power
source to the SP+ and SP
terminals on the ioThinx
Series
The ioThinx 4530 Series is an advanced modular controller device with
a unique hardware and software design that makes it ideal for a variety
of industrial data a cquisition applications.
Appearance (ioThinx 4533)
Package Checklist
• 1 x ioThinx 4530 Series product
• 1 x quick insta llation guide (printed)
• 2 x side cover plate
Installation
Connecting System Power
-
4530
’ terminal block.
- 2 -
The system grounding connectors
are
located on the back of the unit,
as shown in the diagram.
The grounding connectors will
contact the DIN
product is attached to it.
The ioThinx 4530 Series can receive
field power
powe
to supply power for some
I/O
modules, such as digital
analog output modules.
rail when the
Connecting Field Power
through a 12/24 VDC
r input. Field power can be used
types of
input and
- 3 -
Connecting the Field Power Ground
Connect the Field Ground pin () to
the
(P1)
(P1)
(P1/P2)
1
TXD
TXD+
DATA 1+
2
RXD
TXD-
DATA 1-
3
RTS
RXD+
DATA 2+
4
CTS
RXD-
DATA 2-
5
GND
GND
GND
field power ground.
Connecting to the Network
Ethernet Communication
The ioThinx 4530 Series is equipped with two RJ45 LAN ports with two
MAC addresses. Connect a network Ethernet cable to either port to
provide an Ethernet connection to the unit.
Serial Communication
The ioThinx 4530 Series is equipped with a 3-in-1 serial interface that
supports either 1 RS-232 port, 1 RS-422 port, or 2 RS-485 ports. Refer
to the pin assignment table below for details.
PIN
RS-232
RS-422
RS-485
45M Module Wiring
For more detailed information about 45M modu le wiring, additional
ioThinx 4530 Series documentation can be downloaded from the Moxa
website.
- 4 -
Installing the System on a DIN Rail
Step 2: Push the unit towards the
DIN
in
Step 1:
side by side with the head/CPU
module, making sure that the
upper and lower rails are hooked
together.
Reserve at least 55 mm of space above the DIN rail to ensure that
there is enough room to install the unit.
Step 1: Hook the top mounting clip of the unit onto the DIN rail and
then rotate the unit downwards until the bottom mounting clip comes in
contact with the DIN rail.
rail until the mounting clip snaps
to place.
Installing a 45M Module on a DIN Rail
Align the 45M module
- 5 -
Step 2: Push the 45M module
until it touches the DIN rail.
Next,
apply more force until the module
clips to the DIN rail.
NOTE
After the module is firmly attached to the DIN
connections between the
established.
WARNING
Be sure the power is off before removing modules to avoid
damaging the equipment.
Step 1: Use your finger to lift the
release tab on the lower part of the
module.
NOTE
Electrical connect ions for the internal bus will be disconnected
when the 45M module is removed.
module and the internal bus will be
Removing a 45M Module from a DIN Rail
rail, the
Step 2: Push the top of the release tab to latch it, and then pull the
module out.
- 6 -
Installing Covers on the First and Last Modules
NOTICE
Be sure to attach the covers to provide
electrostatic discharge.
Before installing the
device, make sure there is
enough space between the
device
(walls, other devices, etc.)
to ensure proper heat
dissipation.
To ensure that the device
works properly, we
suggest reserving the
amount of space indicated
in the adjacent figure.
C
DO NOT install the device vertically. If the device is in stalled
vertically, the fanless heat dissipation design will not perform
as intended.
Attach the covers to the first and last module to protect the modules’
contacts.
protection against
Horizontal Installation
and nearby items
AUTION
- 7 -
LED Indicators
System
Power
On: Power on
Off: Power off
Field
Power
On: Power on
Off: Power off
the firmware
User
defined
accessed
Green: 100Mb
Off: Inactive
Green: Tx
Off: Inactive
Port
Default IP
Subnet Mask
LAN1
192.168.127.254
255.255.255.0
LAN2
192.168.126.254
255.255.255.0
NOTE
Be sure to configure the host PC’s IP address to use the same
subnet as the unit. For example, 192.168.127.253
port.
Label Usage Qty Color Action
SP
1 Green
FP
System
RDY
(kernel)
U1/U2
microSD
SD
card
L1/L2 Ethernet 1 of each
P1/P2 Serial 1 of each
1 Green
Green: System ready
Green (blinking): System is
booting up
1 Green/Red
1 of each Green/Red User-defined
1 Green
Green/
Amber
Green/
Amber
Red: System error, or
executing factory default
Red (blinking): Tr iggering
factory default, or upgrading
Green: SD card is inserted
OFF: SD card is being
Amber: 10Mb
Blinking: Data is being
transmitted
Amber: Rx
Blinking: Data is being
transmitted
Connecting to the ioThinx 4530 Series Controller
Use the follo wing configuration information to log in to the ioThinx 4530
Series controller:
• Username: moxa
• Password: moxa
Loading the Factory Default Settings
1. Power off the device.
2. Press and hold the reset button; while holding the reset button:
a. Power on the device; the RDY LED will blink green while the
device is booting up.
b. After the device has booted up, the RDY LED will blink red;
continue holding the reset button until the RDY LED stops
blinking.
3. Release the reset button to load the factory default settings.
- 8 -
for LAN1
NOTE
It should take about 20 seconds from the time the RDY LED
starts blinking green until it stops blinking red.
How to Download the Software
Input Current
800 mA @ 12 VDC
Input Voltage
12 to 48 VDC
Field Power: 12/24 VDC
-40 to 75°C (-40 to 167°F)
Storage Temperature
-40 to 85°C (-40 to 185°F)
Related software packages can be downloaded from the Moxa website.
Step 1: Go to the following address:
https://www.moxa.com/en/support
Step 2: Select a product list from the drop-down box or type the model
name in the search box. In the following screenshot, the ioLogik E1200
Series is used to illustrate.
Step 3: Go to the Software & Documentation page to download the
latest software for the product.
Specifications
Operating Temperature Standard Models:
-20 to 60°C (-4 to 140°F)
Wide Temp. Models:
- 9 -
Attention
Moxa Inc.
Fl.4, No. 135, Lane 235, Baoqiao Rd.
Xindian Dist., New Taipei City, Taiwan R.O.C.
1. This device is only for indoor use in environments with pollution
degree 2.
2. This device has field power ground and two ground pins on the
back of the device. For surge protection, connect the field power
ground pin to your field power ground and connect the DIN rail to
earth ground.
3. Cables rated for a minimum temperature of 105°C must be used
for the Power Supply Terminal.
4. We suggest using the following cable types for wiring:
• ioThinx 4530 Series:
> AWG 12 to 16 for power connections
> AWG 16 to 28 for serial connections
• 45MR-7210:
> AWG 12 to 16 for power connections
• 45MR-2600/2601/2606 Digital Output Terminals:
> AWG 16 to 18
• 45MR-2404 Relay Output Terminal:
> AWG 16 to 18
• All other 45MR modules:
> AWG 16 to 24
- 10 -