MovinCool CLASSICPLUS26 User Manual

OPERATION MANUAL
CLASSIC PLUS 14 and CLASSIC PLUS 26
Unit Serial Number Range: 0711XXXX### to Present
(From July 2011 to Present)
READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT
INSTALLATION AND USAGE, AND READ ALL SAFEGUARDS
SECCIÓN EN ESPAÑOL
SECTION EN FRANÇAIS

SERIAL NUMBER LOCATION AND IDENTIFICATION

Nameplate Label
COOLING AMPS. WITH PUMP
COMPR. OUTPUT
REFRIGERANT/TOTAL CHARGE
DESIGN PRESSURE LO/HI
PART NO./WEIGHT
SERIAL NO.
Nameplate Label Position
Month
Year
Model
Sequential Number
© 2013 DENSO PRODUCTS AND SERVICES AMERICAS, INC. All rights reserved. This book may not be reproduced or copied, in whole or in part, without the written permission of the publisher. DENSO PRODUCTS AND SERVICES AMERICAS, INC. reserves the right to make changes without prior notice. MovinCool®, Office Pro®, and SpotCool® are registered trademarks of DENSO Corporation.
OPERATION MANUAL
CLASSIC PLUS 14 and CLASSIC PLUS 26

Table of Contents

SERIAL NUMBER LOCATION AND IDENTIFICATION .................................. 2
FOREWORD ......................................................................................................5
Definition of Terms................................................................................ 5
GENERAL WARNINGS & CAUTIONS.............................................................. 6
INVENTORY & ASSEMBLY .............................................................................. 7
Inventory ................................................................................................ 7
Assembly ............................................................................................... 8
INSTALLATION .................................................................................................9
Choosing an Installation Site ...............................................................9
Moving the Unit ................................................................................... 10
Plugging in the Unit............................................................................. 11
Warning Signal Connection................................................................ 12
Fire Alarm Control Panel Connection................................................ 13
LCDI Power Cord Instruction ............................................................. 14
FEATURES ......................................................................................................15
OPERATION ....................................................................................................16
Control Panel .......................................................................................16
LCD Indicators..................................................................................... 18
Set Clock ..............................................................................................20
Operating in COOL Mode.................................................................... 20
Operating in FAN ONLY Mode............................................................ 21
Changing from FAN ONLY Mode to COOL Mode............................. 21
Keypad Lock ........................................................................................21
How to Set a Program .........................................................................22
How to View and Delete Program ...................................................... 23
How to Run and Stop Program .......................................................... 23
Operating Modes .................................................................................24
Self-Diagnostic Codes ........................................................................ 25
Empty the Drain Tank ......................................................................... 26
Condensate Pump Kit (Optional for Classic Plus 14) ...................... 27
Condensate Pump Kit (Optional for Classic Plus 26) ...................... 28
DAILY INSPECTION & MAINTENANCE......................................................... 29
Empty the Drain Tank ......................................................................... 29
Clean the Air Filters ............................................................................ 29
Filter Removal Method........................................................................ 29
Filter Element Cleaning Method......................................................... 29
In-Season/Off-Season Inspection & Maintenance............................30
TROUBLESHOOTING ..................................................................................... 31
TECHNICAL SPECIFICATONS....................................................................... 32

FOREWORD

Congratulations on purchasing the MovinCool portable air conditioner. This manual explains how to install and operate the MovinCool Classic Plus 14, and Classic Plus 26 portable air conditioning units. Please read this operation manual thoroughly to familiarize yourself with the features of the unit and to ensure years of reliable operation.
You may also find it useful to keep this operation manual on hand for reference. Components and/or procedures are subject to change without prior notice.

Definition of Terms

WARNING: Describes precautions that should be observed in order to
prevent injury to the user during installation or unit operation.
CAUTION: Describes precautions that should be observed in order to
prevent damage to the unit or its components, which may occur during installation or unit operation if sufficient care is not taken.
Note: Provides additional information that facilitates installation or unit operation.
5

GENERAL WARNINGS & CAUTIONS

1. All electrical work, if necessary, should only be performed by qualified electrical personnel. Repair to electrical components by non-certified technicians may result in personal injury and/or damage to the unit. All electrical components replaced must be genuine MovinCool parts, purchased from an authorized reseller.
2. The proper electrical outlet for MovinCool units must be equipped with a UL approved circuit breaker.
3. Because of potential safety hazards under a certain condition, we strongly recommend against the use of an extension cord. However, if you still elect to use an extension cord, it is absolutely necessary that it is a UL listed, 3-wire grounding type appliance extension cord, having a 3-blade grounding plug and a 3-slot receptacle that plugs into the appliance. The marked rating of the extension cord should be 115 V, 15 A for Classic Plus 14, and 230 V, 20 A for Classic Plus 26 or equivalent.
4. The Classic Plus 14 is equipped with a 10 ft (3.0 m) UL approved LCDI power cords. The Classic Plus 26 is equipped with a 6 ft (1.8 m) UL approved LCDI power cord. For replacement, fixed location (hardwire) or power cord lengthening (extension cord) cords are required, contact your MovinCool reseller or a qualified electrician for approved replacement methods.
5. Never fold or place heavy objects on the power cord. This could result in damage to the power cord causing electrical shock or fire.
6. Do not place water or any other liquid on the unit. This can cause damage to the unit and increase the risk of electrical shock.
7. Do not sit or stand on the unit.
6

INVENTORY & ASSEMBLY

Inventory

After unpacking your MovinCool unit, please check to make sure you have the following items:
1. Classic Plus 14 or Classic Plus 26 MovinCool Unit (1)
2. Cool Air Outlet Ducts (2)
3. Screws (8)
4. Operation Manual/Product Registration (1)
Note: If any of these items were not included in the box or appear damaged, please contact your MovinCool reseller for replacement.
COOL AIR OUTLET DUCT(S)
MOVINCOOL UNIT
SCREWS
OPERATION MANUAL / PRODUCT REGISTRATION
7
INVENTORY & ASSEMBLY (cont.)
)

Assembly

CAUTION: Before assembling make sure the unit is on a flat, level
surface and the casters are in the LOCKED position. (Both the Classic Plus 14 and Classic Plus 26 MovinCool units have locking swivel casters in the front only.)
UNLOCKED
LOCKED
Install each cool air outlet duct using 4 screws each as shown.
Note: Do not over tighten the screws when installing the cool air outlet ducts. This could damage the base on the cool air outlet duct assembly.
COOL AIR OUTLET DUCT (2)
SCREW (4 PER DUCT
8

INSTALLATION

Choosing an Installation Site

CAUTION: Following are some precautions to consider before
choosing your installation site. Please review carefully as improper installation may result in personal injury or damage to the unit.
1. Do not use the unit in areas where leakage of flammable gas may occur.
2. Do not use the unit in areas where it is exposed to rain or water.
3. Do not use the unit in an atmosphere of excessively corrosive gas or vapor.
4. Do not use in areas where the temperature is outside the allowable operating range.
5. Do not install the unit in sloping areas. The unit may move or topple over even if the casters are set to the LOCKED position.
6. Install the unit in areas that can with-stand the weight of the unit. The Classic Plus 14 unit weighs approximately 201 lb (91 kg), and the Classic Plus 26 unit weighs approximately 234 lb (106 kg) when the drain tank is full of water.
7. Allow 18.0 in (457 mm) of unobstructed airflow for both the air inlets and outlets.
8. Do not use the unit at condition above 113 °F (45 °C) 50 %RH.
9
INSTALLATION (cont.)

Moving the Unit

Unlock the casters and push the MovinCool unit to a flat level surface and set the casters back to the LOCKED position.
UNLOCKED
LOCKED
10
INSTALLATION (cont.)

Plugging in the Unit

1. Check the prongs and surface of the power cord plug for dust/dirt. If dust and/ or dirt are present, wipe off with a clean, dry cloth.
2. Check the power cord, plug and prongs for damage or excess play. If any damage or excess play is found, contact your MovinCool reseller or a qualified technician for repair.
WARNING:
1. If the power cord or plug is damaged, repair should only be performed by qualified electrical personnel.
2. Do not connect/disconnect the power cord or attempt to operate buttons with wet hands. This could result in electrical shock.
CAUTION:
1. Classic Plus 14 ONLY: The AC outlet (115 VAC Single Phase, 60 Hz) needs to be rated at 15 A or higher. Do not share the outlet with any other instrument or equipment.
2. Classic Plus 26 ONLY: The AC outlet (208/230 VAC Single Phase, 60 Hz) needs to be rated at 20 A or higher. Do not share the outlet with any other instrument or equipment.
Note:
1. Make sure the AC outlet is free of dirt, dust, oil, water, or any other foreign matter.
2. The Classic Plus 14 is equipped with a UL approved LCDI cord and an approved NEMA plug configuration (5-15). The appropriate outlet must be used for this plug type.
3. The Classic Plus 26 is equipped with a UL approved LCDI cord and an approved NEMA plug configuration (6-20). The appropriate outlet must be used for this plug type.
11