MovinCool CLASSIC60 User Manual

OPERATION MANUAL
CLASSIC 40 and CLASSIC 60
Unit Serial Number Range: 0711XXXX### to Present
(From July 2011 to Present)
READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT
INSTALLATION AND USAGE, AND READ ALL SAFEGUARDS
SECCIÓN EN ESPAÑOL
SECTION EN FRANÇAIS

SERIAL NUMBER LOCATION AND IDENTIFICATION

Nameplate Label Position
Nameplate Label
COOLING AMPS. WITH PUMP
COMPR. OUTPUT
REFRIGERANT/TOTAL CHARGE
DESIGN PRESSURE LO/HI
PART NO./WEIGHT
SERIAL NO.
Month
Model
Sequential Number
Year
© 2013 DENSO PRODUCTS AND SERVICES AMERICAS, INC. All rights reserved. This book may not be reproduced or copied, in whole or in part, without the written permission of the publisher. DENSO PRODUCTS AND SERVICES AMERICAS, INC. reserves the right to make changes without prior notice. MovinCool®, Office Pro®, and SpotCool® are registered trademarks of DENSO Corporation.
OPERATION MANUAL
CLASSIC 40 and CLASSIC 60

Table of Contents

SERIAL NUMBER LOCATION AND IDENTIFICATION ...................................2
FOREWORD ......................................................................................................5
Definition of Terms.........................................................................................5
GENERAL WARNINGS & CAUTIONS..............................................................5
INVENTORY & ASSEMBLY .............................................................................. 6
Inventory .........................................................................................................6
Assembly of Exhaust Duct (For Classic 60 ONLY) ..................................... 8
INSTALLATION .................................................................................................9
Unit Overview.................................................................................................. 9
Exterior Dimensions..................................................................................... 10
Choosing an Installation Site ...................................................................... 12
Plugging in the Unit (For Classic 40 ONLY)............................................... 13
Power Supply and Field Wiring Connection (For Classic 60 ONLY) ....... 14
Optional Accessories and Set Up Configuration ...................................... 16
Wall Thermostat Connection (Millivolt System ONLY: Option) ............... 24
Warning Signal Connection (Output Signal Terminal L+ and L-)............. 27
Fire Alarm Control Panel Connection (Input Signal Terminal E+
and E-) .................................................................................................. 29
OPERATION ....................................................................................................31
Features......................................................................................................... 31
Control Panel ................................................................................................ 32
Operating Modes .......................................................................................... 34
Operating in COOL Mode............................................................................. 35
Operating in FAN ONLY Mode..................................................................... 35
Changing from FAN ONLY Mode to COOL Mode ...................................... 35
Self-Diagnostic Codes ................................................................................. 36
DAILY INSPECTION & MAINTENANCE.........................................................37
Clean the Air Filters...................................................................................... 37
Filter Removal Method ................................................................................. 37
Filter Element Cleaning Method..................................................................37
In-Season/Off-Season Inspection & Maintenance..................................... 38
TROUBLESHOOTING ..................................................................................... 40
Installation Check Sheet .............................................................................. 42
TECHNICAL SPECIFICATIONS......................................................................43

FOREWORD

Congratulations on purchasing the MovinCool spot cooling system. This manual explains how to assemble, install and operate the MovinCool Classic 40, and Classic 60 spot cooling system. Please read this operation manual thoroughly to familiarize yourself with the features of the unit and to ensure years of reliable operation.
You may also find it useful to keep this operation manual on hand for reference. Components and/or procedures are subject to change without prior notice.

Definition of Terms

WARNING: Describes precautions that should be observed in order to
prevent injury to the user during installation or unit operation.
CAUTION: Describes precautions that should be observed in order to
prevent damage to the unit or its components, which may occur during installation or unit operation if sufficient care is not taken.
Note: Provides additional information that facilitates installation or unit operation.

GENERAL WARNINGS & CAUTIONS

1. All electrical work, if necessary, should only be performed by qualified electrical personnel. Repair to electrical components by non-certified technicians may result in personal injury and/or damage to the unit. All electrical components replaced must be genuine MovinCool parts, purchased from an authorized reseller.
2. Installation should be conducted by a qualified technician only. DENSO and DENSO affiliates are not responsible for injuries and/or damages caused by improper installation.
3. Never fold or place heavy objects on the power cord. This could result in damage to the power cord causing electrical shock or fire.
4. Do not place water or any other liquid on the unit. This can cause damage to the unit and increase the risk of electrical shock.
5. Do not sit or stand on the unit.
6. Do not place hands or any object in the cool air outlet or exhaust duct. Touching the fan, which is rotating at a high speed, is very hazardous.
5

INVENTORY & ASSEMBLY

CLASSIC 40 UNIT
CLIP GROMMET
OPERATION MANUAL / PRODUCT REGISTRATION

Inventory

Classic 40
After unpacking your MovinCool unit, please check to make sure you have the following items:
1. Classic 40 MovinCool Unit (1)
2. Clip (2)
3. Grommet (2)
4. Operation Manual/Product Registration (1)
Note: If any of these items were not included in the box or appear damaged, please contact your MovinCool reseller for replacement.
6
INVENTORY & ASSEMBLY (cont.)
CLASSIC 60 UNIT
CLIP GROMMET
OPERATION MANUAL / PRODUCT REGISTRATION
EXHAUST DUCT FOR CONDENSER
Inventory (cont.)
Classic 60
After unpacking your MovinCool unit, please check to make sure you have the following items:
1. Classic 60 MovinCool Unit (1)
2. Exhaust Duct for Condenser (1)
3. Clip (2)
4. Grommet (2)
5. Operation Manual/Product Registration (1)
Note: Power cord is not supplied with Classic 60. If any of these items were not included in the box or appear damaged, please contact your MovinCool reseller for replacement.
7
INVENTORY & ASSEMBLY (cont.)
EXHAUST DUCT PACKAGE
M6 BOLTS (8)
EXHAUST DUCT

Assembly of Exhaust Duct (For Classic 60 ONLY)

1. Remove the exhaust duct from the package.
2. Install the exhaust duct to the unit, using eight (8) bolts provided in the exhaust duct package.
8

INSTALLATION

EXHAUST DUCT
COOL AIR OUTLET
AIR FILTERS
CONTROL PANEL
POWER CORD
EXHAUST DUCT
COOL AIR OUTLET
CONTROL PANEL
AIR FILTERS

Unit Overview

Classic 40
Classic 60
9
INSTALLATION (cont.)
2.8
37.8
4xM20
2.8
30.1
41.3
4.8
6.9
5.1
10.0
5.1
25.8
DIA. 13.8
DIA. 22.0
10.0
20.7
12.9
43.5
5.1
10.2
4.3
6XM6
2X6XM6
22.4
1.9 2.3
8.9 8.9
3.9
DIA. 20.7
11.811.8
23.6
1.6
1.6
1.2
25.6
DIA. 0.6
Unit: inch

Exterior Dimensions

Classic 40
10
INSTALLATION (cont.)
8.729.9
4xDIA. 0.5
3.5
33.8
5.1
7.1
31.5
3.1 25.2 3.1
DIA. 25.1
DIA. 13.8
11.522.015.8
49.4
31.7
9.3
8.5
8XM6
6xM6
DIA. 26.2
4.3
1.3
DIA. 1.0
6.5 6.5
6.5
2.4
7.9 7.9
10.2
Unit: inch
Exterior Dimensions (cont.)
Classic 60
11
INSTALLATION (cont.)

Choosing an Installation Site

CAUTION: Following are some precautions to consider before
choosing your installation site. Please review carefully as improper installation may result in personal injury or damage to the unit.
1. Do not use the unit in areas where leakage of flammable gas may occur.
2. Do not use the unit in an environment which contains excessive amounts of corrosive gas or vapor.
3. Do not place obstacles near the air inlet and outlet. Insufficient air flow may activate the protection device or result in insufficient cooling.
4. Install the unit level with no more than 1.5 ° incline.
5. Install the unit in areas that can with-stand the weight of the unit. The Classic 40 unit weighs approximately 344 lb (156 kg), and the Classic 60 unit weighs approximately 474 lb (215 kg).
6. Allow 18.0 in (457 mm) of unobstructed airflow for both the air inlets and outlets.
7. Do not use the unit at condition below 75 °F (24 °C) or above 113 °F (45 °C) 50 %RH.
8. Provide proper ventilation if the unit is installed in an enclosed area.
12
INSTALLATION (cont.)

Plugging in the Unit (For Classic 40 ONLY)

1. Check the prongs and surface of the power cord plug for dust/dirt. If dust and/ or dirt are present, wipe off with a clean, dry cloth.
2. Check the power cord, plug and prongs for damage or excess play. If any damage or excess play is found, contact your MovinCool reseller or a qualified technician for repair.
WARNING:
1. If the power cord or plug is damaged, repair should only be performed by qualified electrical personnel.
2. Do not connect/disconnect the power cord or attempt to operate buttons with wet hands. This could result in electrical shock.
3. The power supply should be a dedicated single outlet circuit with a UL approved short-circuit and ground fault protective breaker with a recommended fuse size of 25 A (25 A maximum).
4. Because of potential safety hazards under a certain condition, we strongly recommend against the use of an extension cord. However, if you still elect to use an extension cord, it is absolutely necessary that it is a UL listed, 4-wire grounding type appliance extension cord, having a 4-blade grounding plug and a 4-slot receptacle that plugs into the appliance. The marked rating of the extension cord should be 220 V, 25 Aor equivalent.
CAUTION: The AC outlet should be rated minimum 25 A at 220 VAC, 3
phase, 60 Hz. Do not share the outlet with any other instrument or equipment.
Note:
1. Make sure the AC outlet is free of dirt, dust, oil, water, or any other foreign matter.
2. The Classic 40 is equipped with an approved NEMA plug configuration (L15-
30). The appropriate outlet must be used for this plug type.
13
INSTALLATION (cont.)
CIRCUIT BREAKER WITH GROUND-FAULT PROTECTIVE
FUSE 20 A (20 A MAX.)
RS TG
RS TG
TERMINAL BLOCK OF Classic 60
GROUNDING TERMINAL
GREEN COLORED WIRE
POWER SOURCE AC 460 V, 3 PHASE, 60 Hz

Power Supply and Field Wiring Connection (For Classic 60 ONLY)

Power Supply
• AC 460 V±10 %, 3 phase and 60 Hz. Do not connect the unit to any other power
supply.
• The power supply should be a dedicated single outlet circuit with a UL approved
short-circuit and ground fault protective breaker with a recommended fuse size of 20 A (20 A maximum).
• Securely tighten each terminal.
CAUTION: Use a specified 20 A fuse. Do not use wiring, copper wire or
soldering instead of the fuse. The use of non-specified fuses can cause machine failure or fire.
14