Optical fiber modules for transmission of incremental encoder or sensor signals
Product features:
Modules for data transmission of incremental encoder or sensor signals via an optical fiber Safe and reliably transmission of incremental signals, up to a distance of 3000 meters Four channels allowing a signal transmission with a sample rate of 10 MHz each For all incremental RS422, 5V-TTL or 10 to 30 V HTL encoders and sensors The optical fiber cable can be routed through explosive areas as well Input / Output data rate of max. 2 Mbit/s (transmitter and receiver) Resistant against extremely strong electromagnetic fields Already assembled optical fiber cables are available Power supply either 5 VDC or 10 to 30 VDC
Available systems (Transmitter and receiver with the same wave length are arbitrarily combinable):
Transmitter (1300 nm)
Transmitter (850 nm)
Output levels:
Power supply
LW213
LW215
RS422
5 VDC (± 5%)
LW213-1
LW215-1
RS422
10 ... 30 VDC
LW213-2
LW215-2
HTL (push-pull / dual channel) *
10 ... 30 VDC
LW213-3
LW215-3
HTL (push-pull / single channel)
10 ... 30 VDC
Receiver (1300 nm)
Receiver (850 nm)
Output levels:
Power supply
LW214
LW216
RS422
5 VDC (± 5%)
LW214-1
LW216-1
RS422
10 ... 30 VDC
LW214-2
LW216-2
HTL (push-pull)
10 ... 30 VDC
*) dual channel transmitter variants cannot be operated as single channel units
Lw215_01g_oi_e.doc / Apr-16 Page 2 / 10
Version:
Description:
LW21501a/pp/01_2012
First edition
LW21501b/pp/09_2012
Enhanced by LW213-LW214; Changed dimension and color for all modules
LW21501c/pp/11_2012
Small Changes
LW21501d/pp/02_2013
Implementation of new product photo
LW21501e/mb-sk/Sept.14
Correction Transmission
Lw215_01f_oi/ag/Sept.14
Safety Instructions and design new, Technical Specifications updated Note added: dual channel variants cannot be operated in single channel mode
Lw215_01f_oi/ag/Mar-16
Technical Specifications updatet
Legal notices:
All contents included in this manual are protected by the terms of use and copyrights of motrona GmbH. Any reproduction, modification, usage or publication in other electronic and printed media as well as in the internet requires prior written authorization by motrona GmbH.
Table of Contents
1. Safety Instructions and Responsibility ......................................................... 3
1.1 General Safety Instructions ................................................................................... 3
1.2 Use according to the intended purpose ................................................................ 3
1.3 Installation ............................................................................................................. 4
1.4 Cleaning, Maintenance and Service Notes ........................................................... 4
2. Description .................................................................................................. 5
3. Electrical and Optical Connections ............................................................... 6
3.1. Pin Assignment ...................................................................................................... 6
3.2. Electrical Connections ........................................................................................... 7
3.3. Optical Connections .............................................................................................. 8
4. LED Function ................................................................................................ 8
5. Dimensions .................................................................................................. 9
6. Technical Specifications ............................................................................ 10
Lw215_01g_oi_e.doc / Apr-16 Page 3 / 10
1. Safety Instructions and Responsibility
1.1 General Safety Instructions
This operation manual is a significant component of the unit and includes important rules and hints about the installation, function and usage. Non-observance can result in damage and/or impairment of the functions to the unit or the machine or even in injury to persons using the equipment!
Please read the following instructions carefully before operating the device and observe all safety and warning instructions! Keep the manual for later use.
A pertinent qualification of the respective staff is a fundamental requirement in order to use these manual. The unit must be installed, connected and put into operation by a qualified electrician.
Liability exclusion: The manufacturer is not liable for personal injury and/or damage to property and for consequential damage, due to incorrect handling, installation and operation. Further claims, due to errors in the operation manual as well as misinterpretations are excluded from liability.
In addition the manufacturer reserve the right to modify the hardware, software or operation manual at any time and without prior notice. Therefore, there might be minor differences between the unit and the descriptions in operation manual.
The raiser respectively positioner is exclusively responsible for the safety of the system and equipment where the unit will be integrated.
During installation or maintenance all general and also all country- and application-specific safety rules and standards must be observed.
If the device is used in processes, where a failure or faulty operation could damage the system or injure persons, appropriate precautions to avoid such consequences must be taken.
1.2 Use according to the intended purpose
The unit is intended exclusively for use in industrial machines, constructions and systems. Non­conforming usage does not correspond to the provisions and lies within the sole responsibility of the user. The manufacturer is not liable for damages which has arisen through unsuitable and improper use.
Please note that device may only be installed in proper form and used in a technically perfect condition (in accordance to the Technical Specifications” chapter. The device is not suitable for operation in explosion-proof areas or areas which are excluded by the EN 61010-1 standard.