Motorola MICOM-2ES, MICOM-2ETS, MICOM-2RS Supplement to Owner’s Guide

Supplement to Owners Guide
MICOM-2ES/2RS/2TS ALE
HF-SSB Transceivers – Version CK
Table of Contents
Scope ............................................................................................................................ 1
New Model Information ................................................................................................ 1
Functional Enhancements .............................................................................................. 4
ALE Enhancement – Multiple Calls ............................................................................ 4
ALE Enhancement – Occupancy Check Intervals ....................................................... 4
Other Enhancements ................................................................................................ 4
New Options ................................................................................................................. 4
Firmware Upgrade......................................................................................................... 8
Introduction .............................................................................................................. 8
Preparations for Upgrade PCs Using Windows 2000/NT/XP ................................... 8
Upgrading MICOM-2 Firmware ................................................................................ 9

Scope

This Supplement provides information on the new versions (Version CK) of the MICOM-2E/2RS/2TS ALE HF-SSB transceivers. The new versions use enhanced hardware and provide additional ALE capabilities.
Externally, the new versions are similar to the previous MICOM-2E/2RS/2TS ALE versions. However, changes have been made in the wiring of the 44-pin accessories connector located on the rear panel, relative to the 44-pin connector used by the previous versions.
The information appearing in this Supplement is intended for use with the following publications:
Owner’s Guide, MICOM-2E/2RS/2TS ALE HF-SSB Transceivers, Publication 68P02952C60-A
Supplement 68MB000010 to Owner’s Guide, MICOM-2E/2RS/2TS ALE HF-SSB Transceivers.

New Model Information

The new transceiver versions have been assigned new model numbers, as follows:
MICOM-2ES Model M80AMNOKV5CK
MICOM-2ETS Model M81AMNOKV5CK
MICOM-2RS Model M85AMNOKV5CK
IMRMB004 1

44-Pin Accessories Connector

Table 1 lists the current functions of the 44-pin accessories connector, J5.
Asterisks * appear in the
Designation
column next to the pins whose function has changed, relative
to previous equipment versions.
Notes
1. The information appearing in Table 1 supersedes any previous information provided in the Owner’s Guide (Publication 68P02952C60-A) and in the Supplement 68MB000010 to Owner’s Guide.
2. You can continue using the fixed adapter accessory for MICOM-2ES, MICOM-2ETS and MICOM-2RS (part No. 09MB000011). This accessory interfaces between the 44-pin connector and older 25-pin accessories.
Table 1. 44-Pin Accessories Connector, Pin Functions
Pin Designation Description
1 SPKR-
2 STOP SCAN Digital control input for stop scan function
3 SPKR+
4 EXT RX AUDIO+
5 EXT RX AUDIO-
6 EXT TX AUDIO+
7 EXT TX AUDIO-
Differential output to the external 8, 8W speaker
Differential output to the external 8, 8W speaker
Differential received audio output (0 dBm; 600; not controlled by volume, but affected by squelch)
Differential transmit audio input (600 input impedance, 0 dBm is required for full power)
8 PTT IN VOICE Transmission command (short to ground) for voice signals
9 PTT IN DATA Transmission command (short to ground) for data signals
10 PTT IN CW Transmission command (short to ground) for CW (Morse) signals
11 SW A+ Primary DC voltage current limited output (max 1A)
12 DSI/KW C C BDM – Data serial in/kW amplifier channel change
13 KW ON/OFF kW amplifier power on/off output
14 REV CLOSE LOOP * Close the loop of ALC radio (input)
15 RXA Receive input (point-to-point protocol to host/HLC)
16 TXA Transmit output (point-to-point protocol to host/HLC)
17 EX RESET External RESET input (for BDM)
18 GND Ground
19 KW PTT PTT output to kW amplifier
20 EXT ALARM External alarm output (open collector, pulled to ground when external alarm is
activated
2 IMRMB004
Table 1. 44-Pin Accessories Connector, Pin Functions (Cont’d)
Pin Designation Description
21 VPP Flash programming voltage, input to BDM
22 DSC/KW_ALC BDM – Data serial clock/kW amplifier ALC
23 SQ GATE Squelch open/closed indication output
24 DSO/FAN ON/OFF BDM – Data serial out/Fan control
25 FREEZE/KW TU BDM – Freeze/kW amplifier tune
26 GND Ground
27 FWD CLOSE LOOP * ALC radio loop closure input
28 RXC * Receive input (point-to-point protocol to host/HLC)
29 TXB RS-232 transmit output to VP-116, PPS, 500W, ASTIC
30 AMP REV * Maintain constant power at 500W transceiver output
31 RXD * Receive input (point-to-point protocol to host/HLC)
32 TX AUDIO OUT Input to baseband TX path
33 RXB RS-232 protocol receive input to VP-116, PPS, 500W, ASTIC
34 RX AUDIO OUT Input to baseband RX path
35 RX AUDIO IN Output from baseband RX path
36 AMP FWD * Maintain constant power at 500W transceiver output
37 VP PTT * PTT output (active low)
38 TXD * Transmit output (point-to-point protocol to host/HLC)
39 TXC * Transmit output (point-to-point protocol to host/HLC)
40 TX AUDIO IN Output from baseband TX path
41 EXT RX AUDIO(2)+ Audio out from ISB hybrid
42 EXT TX AUDIO(2)– Audio out from ISB hybrid
43 EXT RX DATA– *
44 EXT RX DATA+ *
Baseband output (0 dBm, 600 )
Baseband output (0 dBm, 600 )
IMRMB004 3

Functional Enhancements

Figure 1 through Figure 5 present the menus of the new MICOM-2E/2RS/2TS ALE HF-SSB transceiver CK versions. The main enhancements are described below.

ALE Enhancement – Multiple Calls

When using the ALE function, you can select between making an individual call and making calls to multiple (MULT) destinations.
To reach the multiple call options:
1. Press the
2. Press
MORE
MULT
(F1) – all-call (broadcast) to all the stations
ALL
(F2) – call to all the stations in a selected net.
NET
key to display the
(F1) to display a screen with the following options:
MULT
(F1) option.

ALE Enhancement – Occupancy Check Intervals

The new MICOM-2 versions add the option to select the time interval for occupancy checking: the range is 300 to 3000 msec, in 300-msec steps.

Other Enhancements

For your convenience, under icons in their proper (native) language, irrespective of the currenty selected language.
PROG>LANG
, the new MICOM-2 versions always show the language

New Options

The VP option is now supported by means of the option, G849. The
G849AB
option includes two new items:
G849AB
option, that replaces the previous VP
FKN8149A Cable, VP to MICOM-2, MICOM-3.
to the MICOM-2 (the cable offered with the G849 option cannot be used with the new MICOM-2 transceivers).
FKN8148A Cable Suitcase with VP, MICOM-2, MICOM-3.
4 IMRMB004
New cable, used for connecting the VP-116
Loading...