MCM6728B
2
MOTOROLA FAST SRAM
TRUTH TABLE (X = Don’t Care)
E
W Mode VCC Current Output Cycle
H X Not Selected I
SB1
, I
SB2
High–Z —
L H Read I
CCA
D
out
Read Cycle
L L Write I
CCA
High–Z Write Cycle
ABSOLUTE MAXIMUM RATINGS (See Note)
Rating
Symbol Value Unit
Power Supply Voltage V
CC
– 0.5 to + 7.0 V
Voltage Relative to VSS for Any Pin Except
V
CC
Vin, V
out
– 0.5 to VCC + 0.5 V
Output Current I
out
± 30 mA
Power Dissipation P
D
1.0 W
Temperature Under Bias T
bias
– 10 to + 85 °C
Operating Temperature T
A
0 to + 70 °C
Storage Temperature—Plastic T
stg
– 55 to + 125 °C
NOTE: Permanent device damage may occur if ABSOLUTE MAXIMUM RATINGS are
exceeded. Functional operation should be restricted to RECOMMENDED OPERATING CONDITIONS. Exposure to higher than recommended voltages for
extended periods of time could affect device reliability.
DC OPERATING CONDITIONS AND CHARACTERISTICS
(VCC = 5.0 V ± 10%, TA = 0 to 70°C, Unless Otherwise Noted)
RECOMMENDED OPERATING CONDITIONS
Parameter Symbol Min Typ Max Unit
Supply Voltage (Operating Voltage Range) V
CC
4.5 5.0 5.5 V
Input High Voltage V
IH
2.2 —
VCC + 0.3**
V
Input Low Voltage V
IL
– 0.5*
— 0.8 V
*VIL (min) = – 0.5 V dc; VIL (min) = – 2.0 V ac (pulse width ≤ 2.0 ns) for I ≤ 20.0 mA.
**VIH (max) = VCC + 0.3 V dc; VIH (max) = VCC + 2 V ac (pulse width ≤ 2.0 ns) for I ≤ 20.0 mA.
DC CHARACTERISTICS
Parameter Symbol Min Max Unit
Input Leakage Current (All Inputs, Vin = 0 to VCC) I
lkg(I)
— ± 1.0 µA
Output Leakage Current (E = VIH, V
out
= 0 to VCC) I
lkg(O)
— ± 1.0 µA
Output Low Voltage (IOL = + 8.0 mA) V
OL
— 0.4 V
Output High Voltage (IOH = – 4.0 mA) V
OH
2.4 — V
POWER SUPPLY CURRENTS
Parameter Symbol 6728B–8 6728B–10 6728B–12 Unit Notes
AC Active Supply Current (I
out
= 0 mA) (VCC = max, f = f
max
) I
CCA
195 165 155 mA 1, 2, 3
Active Quiescent Current (E = VIL, VCC = max, f = 0 MHz) I
CC2
90 90 90 mA
AC Standby Current (E = VIH, VCC = max, f = f
max
) I
SB1
60 60 60 mA 1, 2, 3
CMOS Standby Current (VCC = max, f = 0 MHz, E ≥ VCC – 0.2 V,
Vin ≤ VSS + 0.2 V, or ≥ VCC – 0.2 V)
I
SB2
20 20 20 mA
NOTES:
1. Reference AC Operating Conditions and Characteristics for input and timing (VIH/VIL, tr/tf, pulse level 0 to 3.0 V, VIH = 3.0 V).
2. All addresses transition simultaneously low (LSB) and then high (MSB).
3. Data states are all zero.