4-131
FAST AND LS TTL DATA
MC74F258A
FUNCTION TABLE
Output
Enable
Select
Input
Data
Inputs
Output
OE S I
0
I
1
Z
H X X X Z
L H X L H
L H X H L
L L L X H
L L H X L
H = HIGH Voltage Level
L = LOW Voltage Level
X = Don’t Care
Z = High Impedance
GUARANTEED OPERATING RANGES
Symbol Parameter Min Typ Max Unit
V
CC
Supply Voltage 74 4.5 5.0 5.5 V
T
A
Operating Ambient Temperature Range 74 0 25 70 °C
I
OH
Output Current — High 74 –3.0 mA
I
OL
Output Current — Low 74 24 mA
DC CHARACTERISTICS OVER OPERATING TEMPERATURE RANGE (unless otherwise specified)
Limits
Symbol Parameter Min Typ Max Unit Test Conditions
V
IH
Input HIGH Voltage 2.0 V Guaranteed Input HIGH Voltage
V
IL
Input LOW Voltage 0.8 V Guaranteed Input LOW Voltage
V
IK
Input Clamp Diode Voltage –1.2 V IIN = –18 mA VCC = MIN
V
OH
Output HIGH Voltage 74 2.7 3.3 V IOH = –3.0 mA VCC = 4.75 V
74 2.4 VCC = MIN
V
OL
Output LOW Voltage 0.35 0.5 V IOL = 24 mA VCC = MIN
I
OZH
Output OFF Current — HIGH 50 µA V
OUT
= 2.7 V VCC = MAX
I
OZL
Output OFF Current — LOW –50 µA V
OUT
= 0.5 V VCC = MAX
I
IH
Input HIGH Current 20 µA VIN = 2.7 V VCC = MAX
100 µA VIN = 7.0 V
I
IL
Input LOW Current –0.6 mA VIN = 0.5 V VCC = MAX
I
OS
Output Short Circuit Current (Note 2) –60 –150 mA V
OUT
= 0 V VCC = MAX
I
CCH
6.2 9.5 S, I1x = 4.5 V
OE, I0x = GND
I
CCL
Power Supply Current 15.1 23 mA I1x = 4.5 V VCC = MAX
OE, I0x, S = GND
I
CCZ
11.3 17 S, I0x = GND
OE, I1x = 4.5 V
NOTES:
1. For conditions shown as MIN or MAX, use the appropriate value specified under guaranteed operating ranges.
2. Not more than one output should be shorted at a time, nor for more than 1 second.