MOTOTRBO™
SLR 000 Series
#BTF4UBUJPORepeater
QUICK START GUIDE
en
fr-CA
m
MOTOTRBO™ SLR 8000 Series Base Station Repeater Quick Start Guide
Notations Used in This Manual
Note and caution notations are used throughout the text in this publication. These notations are used to emphasize that safety hazards exist,
and due care must be taken and observed.
CAUTION indicates a potentially hazardous situation which, if not avoided, might result in equipment damage.
WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or injury.
W A R N I N G
This symbol indicates areas of the product that pose potential burn hazards.
English
1
General Safety and Installation Standards and Guidelines
WARNING: For safe installation, operation, service and repair of this equipment, follow the safety precautions and
instructions described below, as well as any additional safety information in Motorola’s product service and installation
manuals and the Motorola R56 Standards and Guidelines for Communications Sites manual (which can be obtained by
ordering CD-ROM 9880384V83). To obtain copies of these materials, please contact Motorola as directed at the end of this
section. After installation, these instructions should be retained and readily available for any person operating or servicing this
Base Station Repeater or working near it.
Failure to follow these safety precautions and instructions could result in serious injury or property damage. The installation
process requires preparation and knowledge of the site before installation begins. Review installation procedures and
precautions in the Motorola R56 manual before performing any site or component installation. Personnel must use safe work
practices and good judgment, and always follow applicable safety procedures, such as requirements of the Occupational
Safety and Health Administration (OSHA), the National Electrical Code (NEC), and local codes.
The following are additional general safety precautions that must be observed:
• To continue compliance with any applicable regulations and maintain the safety of this equipment, do not install substitute parts or perform
any unauthorized modifications.
• All equipment must be serviced by Motorola trained personnel.
• If troubleshooting the equipment while the power is on, be aware of live circuits which could contain hazardous voltage.
• Do not operate the radio transmitters unless all RF connectors are secure and all connectors are properly terminated.
• All equipment must be properly grounded in accordance with the Motorola R56 and specified installation instructions for safe operation.
• Slots and openings in the cabinet are provided for ventilation. Do not block or cover openings that protect the devices from overheating.
• Some equipment components can become extremely hot during operation. Turn off all power to the equipment and wait until sufficiently
cool before touching.
• Maintain emergency first aid kits at the site.
• Never store combustible materials in or near equipment racks. The combination of combustible material, heat and electrical energy
increases the risk of a fire hazard.
• Equipment shall be installed in a site that meets the requirements of a “restricted access location,” per (UL60950-1 & EN60950-1), which is
defined as follows: “Access can only be gained by service persons or by users who have been instructed about the reasons for the
restrictions applied to the location and about any precautions that shall be taken; and access is through the use of a tool or lock and key, or
other means of security, and is controlled by the authority responsible for the location.”
2
• Burn hazard. The metal housing of the product may become extremely hot. Use caution when working around the equipment.
English
• RF energy burn hazard. Disconnect power in the cabinet to prevent injury before disconnecting and connecting antennas.
• Shock hazard. The outer shields of all Tx and Rx RF cables outer shields must be grounded per Motorola R56 manual.
• Shock hazard. DC input voltage shall be no higher than 60 VDC. This maximum voltage shall include consideration of the battery charging
“float voltage” associated with the intended supply system, regardless of the marked power rating of the equipment.
• All Tx and Rx RF cables shall be connected to a surge protection device according to Motorola R56 manual. Do not connect Tx and Rx RF
cables directly to an outside antenna.
• Compliance with National and International standards and guidelines for human exposure to Electromagnetic Energy (EME) at
Transmitter Antenna sites generally requires that persons having access to a site shall be aware of the potential for exposure to EME and
can exercise control of exposure by appropriate means, such as adhering to warning sign instructions. See this installation manual and
Appendix A of Motorola R56.
This product complies with the requirements set forth by the European R&TTE regulations and applicable CENELEC standards concerning
human exposure to Electromagnetic Energy (EME) at Transmitter Antenna sites. “Appendix F” of the SLR 8000 Series Base Station Repeater
Basic Service and Installation Manual includes an EME exposure analysis of a typical system configuration for this product.
For a different system configuration than the typical configuration, compliance with applicable EME exposure standards (current versions of
the EN50384 and EN50385 standards for occupational and general public exposure, respectively) can be evaluated by either employing the
method illustrated in the typical system configuration EME exposure analysis included in “Appendix F” in the SLR 8000 Series Base Station
Repeater Basic Service and Installation Manual, or employing another suitable method among those described in the current version of the
EN50383 standard.
Once the occupational and general public compliance boundaries are determined, means to ensure that workers and people are outside the
respective boundaries, for instance using appropriate signage or restricted access, should be implemented; if this is not possible or practically
achievable for the specific system configuration, the configuration should be modified in order to make it possible. The R56 Standards and
Guidelines for Communications Sites manual provides examples of signage that can be used to identify the occupational or general public
compliance boundaries.
Refer to product specific manuals for detailed safety and installation instructions. Manuals can be obtained with product orders, downloaded
from https://businessonline.motorolasolutions.com or purchased through the Motorola Aftermarket & Accessory Department.
3
English