iiOmnii Hand-Held Computer with Windows CE 6.0 User Manual
This user manual supports Model Numbers:
• 7545MBW
• 7545MBWM
• 7545MBWP
• FCC ID: GM37545MBW, GM37545MBWM a nd GM37545MBWP
• IC: 2739D-7545MBW and 2739D-7545MBWP
Copyright
No part of this publication may be reproduced or used in any form, or by any electrical or mechanical means,
without permission in writing from Motorola. This includes electronic or mechanical means, such as
photocopying, recording, or information storage and retrieval systems. The material in this manual is subject to
change without notice.
The software is provided strictly on an “as i s” basis. All sof twar e, including firmware, furnished to the user is on
a licensed basis. Motorola grants to the user a non-transferable and non-exclusive license to use each
software or firmware program delivered hereunder (licensed program). Except as noted below, such license
may not be assigned, sublicensed, or otherwise transferred by the user without prior written consent of
Motorola. No right to copy a licensed program in whole or in part is granted, except as permitted under
copyright law. The user shall not modify, merge, or incorporate any form or portion of a licensed program with
other program material, create a derivative work from a licensed program, or use a licensed program in a
network without written permission from Motorola. The user agrees to maintain Motorola’s copyright notice on
the licensed programs delivered hereunder, and to include the same on any authorized copies it makes, in
whole or in part. The user agrees not to decompile, disassemble, decode, or reverse engineer any licensed
program delivered to the user or any portion thereof.
Motorola reserves the right to make changes to any software or product to improve reliability, function, or design.
Motorola does not assume any product liability arising out of, or in connection with, the application or use of
any product, circuit, or application described herein.
No license is granted, either expressly or by implication, estoppel, or otherwise under any Motorola, Inc.,
intellectual property rights. An implied license only exists for equipment, circuits, and subsystems contained in
Motorola products.
Disclaimer
Every effort has been made to make this mater ial complete, accurate, and up-to-date. In addition, changes ar e
periodically incorporated into new editions of the publication.
Motorola reserves the right to make improvements and/or changes in the product(s) and/or the program(s)
described in this document without notice, and shall not be responsible for any damages including, but not
limited to, consequential damages, caused by reliance on the material presented.
Motorola, the Motorola logo, Workabout Pro4 and the na mes of other products and services provided by
Motorola are trademarks of Motorola.
Windows® and the Windows Logo are trademarks or registered trademarks of Microsoft Corporation in the
United States and/or other countries.
The Bluetooth® word mark and logos are owned by Bluetooth SIG, Inc. and any use of such marks by Motorola
is under license.
All trademarks used herein are the property of their respective owners.
Page 5
Revision History
Changes to the original guide are listed below:
ChangeDateDescription
-01 Rev G03/2014Motorola rebrand.
iii
Page 6
Page 7
Table of Contents
TABLE OF CONTENTS
About This Manual..........................................................................................................................xiii
Text Conventions............................................................................................................................ xiv
Overview of the Omnii Hand-Held Computer..................................................................................xiv
About .............................................................................................................................................3-17
The Bluetooth GPRS WAN Connection.......................................................................................3-18
Dr. Debug ....................................................................................................................................... 3-25
St atus..............................................................................................................................................3-25
This user manual describes the configuration, ope ra tion, and maintenance of the Omnii Hand-Held Computer.
Chapter 1: Basic Operation
describes the steps required to get the Omnii ready for operation.
Chapter 2: Getting To Know Your Omnii
About This Guide xiii
describes Omnii features, including how to charge and maintain the battery, the keyboard features, the display, using the internal scanner, etc. This chapter also describes the Microsoft
Windows
desktop from Windows Classic Shell to the Kiosk Shell.
Chapter 3: Configuration
describes the programs and applications accessed through two main areas from the Desktop
Start Menu: Programs and Settings>Control Panel. The software includes both Motorola Software
Advantage and Microsoft programs, and details how to use them to configure the Omnii, along
with scanners/imagers, Bluetooth, etc. This chapter also details the Kiosk program, which enables
you to customize your computer settings.
Chapter 4: Accessories
describes the peripherals and accessories available for your Omnii computer.
Appendix A: Port Pinouts
describes the Omnii and accessories pinouts.
Appendix B: Imager & Camera Settings
describes in detail your imager’s settings.
Appendix C: Scanner Settings
details your barcode options.
®
Embedded CE 6.0 desktop, and how to change the appearance and actions of the
IMPORTANTThese statements provide particularly important instructions or addi-
tional information that is critical to the operation of the equipment.
WARNINGThese statements provide critical information that may prevent
physical injury, equipment damage or data loss.
Overview of the Omnii Hand-Held Computer
The Omnii Hand-Held Computer is a modular , industr ial hand-held computer. A variety of options are available
to suit applications in courier/delivery, field service, manufacturing facilities, material handling applications in
warehouses, ports and yards, with a focus on real time wireless data transactions. Barcode input methodologies are supported by a variety of available scanners. Optimization for specific operational environments is
also supported with a wide range of peripheral options and carrying accessories.
The Omnii XT15f (Freezer Variant) combines modularity, customizability and performance with added technology to resist condensation for use in cold, condensing environments. For details, see Appendix F: “Omnii
XT15f Freezer Variants”.
NOTEThe Omnii Hand-Held Computer is a body worn device, and to maintain compli-
ance with the FCC RF exposure guidelines, use a Motorola approved carrying
case. Use of non-approved accessories may violate FCC RF exposure
guidelines.
NOTEFor product specifications, refer to Appendix E: “Omnii Specifications”.
Model Variant s
•Omnii RT15 Hand-Held Computer (rugged) - Model 7545XC
•Omnii XT15 Hand-Held Computer (extremely rugged) - Model 7545XT
- Passive stylus or finger operation; pan and flick gestures supported
- Signature capture
•Keyboards
- Large selection of backlit keypads in both alpha and numeric formats. For a list of currently
available keyboard configurations, consult your Motorola representative, or go to:
The Omnii is powered by a Lithium-ion Smart Battery pack, 5000 mAh — Model ST3001.
IMPORTANTBefore charging the battery, it is critical that you review the battery
safety guidelines in the Omnii Hand-Held Computer Regulatory &
Warranty Guide (PN 8000191).
Battery packs shipped from the factory are charged to approximately 40% and must be fully charged prior to
use. Batteries can be charged using a variety of chargers and docking stations. For detailed information, see
“Battery Details” on page 2-3.
Replacing the Battery Pack
IMPORTANTAlways switch the unit off before changing the battery (see “Switch-
ing the Omnii On and Off” on page 1-7). However, assuming the
default power saving parameters and battery reser ve level have not
been altered, battery swap time is a minimum of 4 minutes — you
will not lose data if the battery is replaced within this time frame.
Figure 1-6
Omnii Battery
NOTEIf you are using a docking station or an external power su pply, you can insert an
uncharged battery and use the device while the battery charges.
Assuming the default power saving parameters and battery reserve level ha ve not been altered, a battery can
be removed for up to 4 minutes without losing data. After 4 minutes the terminal may reboot.
Page 33
Removing the Battery Pack
•If your unit is equipped with a hand strap, unhook it from the base of the battery.
•Press the two buttons at the sides of the compartment simultaneously, and slide the battery out.
Installing the Battery Pack
•Slide the charged battery with the contoured plastic facing you into the unit with the contacts matching
position and the guide tabs moving into the correspondi ng slot s at the base of the comp artment. Click both
sides of the battery into place.
•If your computer is equipped with a hand strap, re-attach the clip to the slot at the base of the battery.
•Switch the unit on (see “Switching the Omnii On and Off” on page 1-7).
Switching the Omnii On and Off
Follow the instructions below for your Omnii. If your keyboard has a power button (55- and 66-key keyboards
only), press that instead of the [FN]+[Enter/Power] key combinations described.
Switching the Omnii On
•Press and hold down the [Enter/Power] key for at least one second.
Basic Operation1 - 7
When the unit is turned off, normally it automatically enters a power-saving, “suspend” state. When the Omnii
is switched on from the suspend state, within a few seconds operat ion resumes in the screen in which you
were working prior to turning the computer off.
IMPORTANTIf your Omnii fails to power up, consider the following troubleshooting options:
The battery may be overheated (>60C°), a non-Motorola battery may be
installed, or the battery may have fallen below the configured Suspend Threshold. See “Suspend Threshold and Estimated Battery Backup” on page 3-45
for details.
To switch on the hand-held, you will need to replace the overheated battery.
However, if you supply AC power to the Omnii with a battery that falls
below the configured Suspend Threshold, the unit will
Switching the Omnii Off
•To switch off the Omnii, press the [FN] key and then press and release the [Enter/Power] button. The
Omnii will automatically enter the Suspend state.
switch on.
IMPORTANTTurning off the hand-held does not result in a complete shutdown;
rather, the unit enters a power-saving, “suspend” state. When the
Omnii is turned on from suspend state, operation resumes within a
few seconds.
Page 34
1 - 8Omnii Hand-Held Computer with Windows CE 6.0 User Manual
IMPORTANT If the word ‘FN’ is displayed underlined in the taskbar area at the
bottom of the screen, this key is locked “on” and the Omnii will not
switch off. Press the [FN] key twice followed by [Enter/Power] to
switch the Omnii off.
However, if you’ve set the mode to “Lock” (se e “Keyboard One Sh ot
Modes” on page 3-34), the Omnii can be turned off even when the
[FN] key is locked ‘on’.
Resetting the Omnii
To perform a warm or cold reset, you can access the menu by going to Start>Shutdown. Alternatively you can
use the keyboard shortcuts described below.
NOTEIf your Desktop is switched to the Kiosk Shell (refer to “The Kiosk Desktop Shell”
on page 2-27), resetting the unit is done solely by use of the keyboard shortcuts.
Performing a Warm Reset
During a warm reset, running programs are halted. The contents of the file system, RAM Disk, Flash Disk, and
the registry are preserved.
• Press and hold down the [FN] key and the [Enter/Power] key simultaneously for a minimum of
four seconds.
NOTEYou need to reset your Omnii after configuring the radio by switching between
Windows Zero Config and WiFi Config.
Performing a Cold Reset
A cold reset reinitializes all hardware. All RAM including the RAM Disk is erased. Non-volatile storage such as
the Flash Disk is preserved, as is the file system.
To execute a cold reset:
• Press and hold down the [SYM] key, the [FN] key, and the [Enter/Power] key, simultaneously for a
minimum of four seconds.
Page 35
NOTEAs part of the normal Windows Embedded CE cold boot process, the screen
Pin 6Pin 5
may go blank for a few seconds after the splash screen loading bar reaches the
end. The desktop is displayed after a few moments.
Performing a Clean Start
A clean start returns the Omnii to factory settings, flushes the registry keys, and deletes volatile storage and
the file system. The Flash Disk is preserved.
•Press and hold down the [FN] key, the [Enter/Power] button and the [SCAN] key simultaneously for a
minimum of six seconds.
The Omnii displays the Boot to BooSt menu.
•On an alpha keyboard, type .clean.
•On a numeric keyboard, type .25326.
Boot to BooSt
If you choose Boot to BooSt, the BooSt menu is loaded.
Basic Operation1 - 9
•Press and hold down the [FN] key, the [Enter/Power] button and the [SCAN] key for a minimum of four
seconds.
•Press [1] to launch the OS.
Performing a Hard Reset
IMPORTANTThis procedure is recommended as a last resort, when all other
To execute a hard reset:
•Remove the battery.
•Using a coin, or other conductive item, connect pins 5 and 6 of the battery contacts for at le ast six seconds.
•Replace the battery and power Omnii on. The terminal will boot as if from a cold reset.
methods fail.
Attaching Carrying Accessories
Motorola recommends that a carrying accessory — a hand strap — be installed on the Omnii before use. For
detailed information, please see “Carrying and Protective Accessories” on page 4-4.
Page 36
1 - 10Omnii Hand-Held Computer with Windows CE 6.0 User Manual
Calibrating the Touchscreen
NOTEThe touchscreen function can be turned off (see “Touch” on page 3-67).
The Omnii touchscreen feature is factory-calibrated and ready-to-go; however, over time the touchscreen's
operating parameters may change, and it may need to be recalibrated for correct operation. Refer to “Cali-
brating the Touchscreen” on page 2-10 for details.
Imager and Scanner Options
If your Omnii is equipped with an internal imager or scanner, please review the relevant sections: Appendix B:
“Imager & Camera Settings” and Appendix C: “Scanner Settings” for details.
Appendix B: “Imager & Camera Settings” lists their current model numbers, descriptions, and specifications.
Connectivity
For information on connecting the Omnii to a PC, please refer to “Data Transfer between Omnii and a PC” on
page 3-22
The Omnii contains an integrated 802.11a/b/g/n radio module. The Wi-Fi Config application is used to
configure the radio for one or more wireless network profiles. To configure the radio, follow the steps outlined
under the heading “Wi-Fi Config” on page 3-80.
To configure your Bluetooth settings, please go to “Bluetooth® Setup” on page 3-11.
If you have a GPS (Global Positioning System) module, you can choose from a set of GPS profiles built into
the modem and set up AGPS (Assisted Global Positioning System). See “GPS (Global Positioning System)
Settings” on page 3-27.
The Omnii is available with one of the following Wireless WAN radio options: the Cinterion MC75i EDGE and
the Cinterion PH8-P HSPA+. See Appendix E: “Omnii Specifications” for full specifications. With either of these
radios and a SIM card, you can wirelessly transfer data (see Appendix G: “Wireless Wide Area Network
(WWAN) Settings”), and you can use the Omnii voice option to place phone ca lls ( see “Voice Communication”
on page 1-11 below).
To see the radio specifications, please go to “Wireless Radios” on page E-6.
.
Data Transfer
Data transfer options vary slightly depending on the type of operating system installed in your PC. Various
options exist depending on whether you are using Windows XP or earlier , Windows Vist a
For connection details, please refer to “Data Transfer between Omnii and a PC” on page 3-22.
®
, Windows 7 or later.
Page 37
Voice Communication
If the MC75i EDGE or the Cinterion PH8-P HSPA+ WWAN radio modem is installed and enabled, the Phone
icon and the GSM signal strength icon will appear automatically on the taskbar . For details on using your Voice
options, please refer to “Voice – Using the WWAN Phone Dialer” on page 3-74.
NOTEThe voice option is not available in North America for the MC75i EDGE radio.
Operating One Dimensional (1D) Internal Laser Scanners.................2-17
Operating Internal Two Dimensional (2D) Imagers .....................2-18
Windows Embedded CE 6.0......................................2-19
Navigating in Windows Embedded CE and Applications . . . . . . . . . . . . . . . . . .2-19
Navigating Using a Touchscreen ..........................2-19
Navigating Using the Keyboard...........................2-19
The Windows Classic Shell Startup Desktop.........................2-20
The Taskbar......................................2-21
The Start Menu....................................2-22
The Kiosk Desktop Shell ..................................... ...2-27
Restoring the Windows Classic Shell.............................2-29
General Maintenance..........................................2-29
Caring for the Touchscreen..................................2-29
Cleaning the Omnii.......................................2-30
Page 41
Operating System
•Microsoft® Windows® Embedded CE 6.0
Battery Details
Omnii Hand-Held Computers are powered by a lithium-ion battery pack, Model ST3001.
Please see the following sections for detailed battery information:
•Installation: “Preparing the Omnii for Operation” on pa ge1-6.
•Calibration and power settings: “Power Properties” on page 3-44.
•Chargers and docking stations: Chapter 4: “Accessories”.
•Specifications: “Lithium-ion Smart Battery 5000 mAh (ST3001)” on page E-5.
•Contact pinout: “Omnii Battery Contacts” on page A-6.
Battery Safety
Getting To Know Your Omnii2 - 3
IMPORTANTBefore attempting to install, use, or charge the ba ttery p ack, it is cr it-
Battery Swap Time
Assuming the default power saving parameters and battery reserve level have not been altered, battery swap
time is a minimum of 4 minutes — you will not lose data if the battery is replaced within this time frame.
To protect data, the safest place to store data is on a microSD memory card or externally to the device on a
USB memory stick or on a PC. You can also save data in the “Flash Disk” partition of the file system.
Refer to “Suspend Threshold and Estimated Battery Backup” on page 3-45 for details about reserving battery
power for data backup purposes.
The Suspend Threshold adjustment in the Power Properties t ab allows you to determin e the battery capacity at
which the Omnii will be shut down. If left at the default value, Maximum Operating Time, the unit will run until
the battery is completely empty; the RAM is only backed up for a short period of time. If you choose Maximum Backup Time, the Omnii shuts off with more energy left in the battery so RAM can be backed up for a longer
period of time.
ical that you review and follow the importan t sa fety guid elin es in the
quick reference guide entitled the Omnii Hand-Held Computer Regulatory & Warranty Guide, PN 8000191.
Page 42
2 - 4Omnii Hand-Held with Windows CE 6.0 User Manual
IMPORTANTIf your Omnii fails to power up, consider the following troubleshoot-
ing options:
The battery may be overheated (>60C°), a non-Motorola battery
may be installed, or the battery may have fallen below the configured Suspend Threshold. See “Suspend Threshold and Estimated
Battery Backup” on page 3-45 for details.
To switch on the hand-held, you will need to replace th e overheated
battery.
However, if you supply AC power to the Omnii with a battery
that falls below the configured Suspend Threshold, the unit will
switch on.
Charging the Battery
Batteries shipped from the factory are charged to approximately 40% of capacity. Lithium-ion battery packs
must be fully charged before use. These batteries can be charged with a variety of chargers and docking
stations. For detailed information on these accessories, please see Chapter 4: “Accessories”.
Normally it takes 3 to 4 hours to charge a battery. The Omnii intelligent charging system protects the battery
from over-charging by terminating the charge process when the battery is at maximum capacity.
IMPORTANTTo avoid damaging the battery, chargers will not begin the charge
The Keyboard
The Omnii offers a wide variety of Alpha and Numeri c keyboard layouts.
See
http://www.motorolasolutions.com/US-EN/Product+Lines/Psion/?WT.mc_id=psion_us_p_handheld for a list of avail-
able configurations. Most of the keys on these keyboards operate much like a desktop computer. Where a key
or key function is not consistent with the PC keyboard, those differences are described in the following
sections.
The Omnii is equipped with either an [Enter/Power] key or Power button (55- and 66-key keyboards only) that
allows you to switch the unit on and to shut down the unit to Suspend mode. For details refer to “Switching the
Omnii On and Off” on page 1-7.
process until the battery temperature is between 0°C to 40°C (32°F
to 104°F).
There are a number of modifier keys that provide access to additiona l keys and system functions, as descri bed
in “Modifier Keys” on page 2-6.
The [Blue/FN] modifier key provides access to additional keys and system functions. These functi ons are
colour coded in blue print above the keyboard keys.
Page 43
Getting To Know Your Omnii2 - 5
36-Key Numeric 123 Keyboard
59-Key Alpha ABC Keyboard
[FN] Modifier Key
[SYM] Key
[SHIFT] Modifier Key
[SCAN] Key
[Enter/Power] Key
[Windows] Key
[End] key
[Talk] key
55-Key Alpha ABC Keyboard with phone
Power button
Figure 2-1
Keyboard Layouts
The Power Button (55-Key and 66-Key Keyboards only)
The [Power] button in the upper right corner of the keyboard switches the unit on and off.
Regular Keys
The [Enter] Key
The [Enter] key is used to execute the usual Enter keyboard functions, and on some units to also power the
unit on and off (for details refer to “ Switching the Omnii On and Off” on page 1-7).
NOTE55-key and 66-key keyboards are equipped with a Power button. For these key-
boards, the [Enter] key does not switch the unit on or off.
Page 44
2 - 6Omnii Hand-Held with Windows CE 6.0 User Manual
The [SHIFT] Key
The [SHIFT] key is used to display uppercase alpha characters and to provide access to other symbols and
functions on the numeric keyboards. Press the [SHIFT] key to turn the shift state 'on' (it will be represented by
an up arrow in the taskbar), then press another key to access the shifted function of that key.
Press the [SHIFT] key twice to lock the shift state on (the up arrow in the taskbar will be underlined). Press
[SHIFT] again to turn the shift state off.
To access CAPS LOCK mode, press [FN] + [SHIFT]. In this state, if you press a numeric key, the number is
displayed rather than the normal shifted function of tha t ke y. Press [FN] + [SHIFT] again to turn the CAPS
LOCK mode off.
The Arrow Keys
The [Arrow] keys are located near the top of the keyboard, and are represented on the keyboard as triangles
pointing in different directions. The [Arrow] keys move the cursor around the screen in the direction of the
arrow: up, down, left and right. The left arrow key should not be confused with the [BACKSPACE] key which is
depicted as a left arrow. The cursor is the flashing box or underline character that indicates where the next
character you type will appear.
The [BACKSPACE/DEL] Key
The [BACKSPACE] key (represented on the keyboard as an arrow pointing left) moves the cursor one character to the left, erasing the previous key stroke.
The [DEL] key ([FN] +[BACKSPACE]) erases the character at the current cursor position.
The [CTRL] and [AL T] Keys
The [CTRL] and [ALT] keys modify the function of the next key pressed and are application dependent.
Pressing either key twice locks it 'on' (it appears underlined on the Taskbar). Pressing the key once again
unlocks it.
The [TAB] Key
Typically, the [TAB] key moves the cursor to the next field to the right or downward.
The [ESC] Key
Generally, this key is used as a keyboard shortcut to close the current menu, dialog box, or activity.
The [SPACE] Key
The [SPACE] key is represented on the keyboard by a long, low horizontal line contained by a small vertical
line on each side. Pressing this key inserts a blank space between characters. In a Windows dialog box,
pressing the [SPACE] key enables or disables a check box.
The [SCAN] Key
The Omnii is equipped with a single [SCAN] key on the keyboard and an extra [SCAN] button located on the
left side of the unit. [SCAN] keys activate the scanner beam. For units that do not ha ve internal scanners, these
keys can be remapped to serve other functions.
Modifier Keys
The [SHIFT], [CTRL], [ALT], [FN] and [SYM] keys are modifier keys that change the function of the next key
pressed.
The [SHIFT], [CTRL] and [ALT] keys operate much like a desktop keyboard except that they are not chorded
(two keys held down simultaneously). The modifier key must be pressed first followed by the key whose function you want modified.
Page 45
Getting To Know Your Omnii2 - 7
36-KEY Numeric Keyboard
59-KEY Alpha Keyboard
[SPACE] Key
Internet Browser Keys
[SHIFT] and [FN]
The [SHIFT] and [FN] modifier keys provide access to additional keys and system functions. The functions
related to these modifier keys are colour-coded in white and blue print respectively above the keyboard keys,
dependant on your keyboard format.
[SYM]
NOTEWhen using the Mobile Devices SDK Developers' Guide (PN 8100016), note
that the [SYM] key is interchangeable with the [ORANGE] key.
The Symbol [SYM] modifier key is represented on the keyboar d by the characters SY M and provides a ccess to
commonly used symbolic characters. Pressing the key brings up the Symbol soft input panel (SIP) onscreen
keyboard, with symbols mapped to each key. If you wish to adjust the settings for the pop -u p screen ( e.g. time
of delay before screen appears, etc.), modify the file softinputpanel.xml, located in the Windows folder.
NOTEModifier keys are remapped in Control Panel, and the Symbol SIP will automat-
ically show and use the new mappings after the next reboot.
The onscreen keyboard corresponds to the specific keyboard on your Omnii — either numeric
or alphanumeric.
Figure 2-2
Symbol Soft Input Panels
Activating Modifier Keys
When a modifier key is pressed, it is shown in the softkey bar at the bottom of the screen, making it easier to
determine whether a modifier key is active. For example, if the [CTRL] key is pressed, Ctrl is displayed at the
bottom of the unit screen. Once the next key is pressed, the modifier key becomes inactive and disappears
from the taskbar.
Locking Modifier Keys
When a modifier key is pressed twice, it is locked on. A locked modifier key is displayed in underlined letters in
the taskbar. For example, pressing the [FN] key twice locks it on — it is displayed as an underlined blue FN in
the taskbar at the bottom of the computer screen. The same is tru e of the [SYM ] key, which is shown as an
underlined orange SYM in the taskbar.
The locked modifier key will remain active until it is pressed a third time to unlock or turn it off. Once a modifier
key is unlocked, the underline representation at the bottom of the screen is no longer displayed.
Page 46
2 - 8Omnii Hand-Held with Windows CE 6.0 User Manual
NOTEThe locking function of the modifier keys can be changed so th at pressing a key
once will lock the key on.
If you disable the One Shot function of the key, pressing it once will lock the key
on. Pressing the same key a second time will unlock or turn it off. Refer to “Key-
board One Shot Modes” on page 3-34 for details.
Function Keys and Macro Keys
In addition to the standard keyboard functions (see “The Keyboard” on page 2-4), the Omnii supports function
keys and macro keys.
All function keys and macro keys can be custom defined for each application. The Open TekTerm application
utilizes these keys (for detailed information, see the Open TekTerm Software User Manual, PN 8000073).
Function Keys
Function keys perform special, custom-defined functions within an application. These keys are accessed by
pressing one of the dedicated function keys on the keyboard, or through the appropriate [SHIFT] or [FN] key
sequence, depending on the keyboard variant being used.
Alphanumeric Keyboard Function Keys
The Alphanumeric keyboards are equipped with up to thirty function keys, including those function keys that
are colour-coded in blue print above the alpha keys or function keys (depending on your keyboard).
To access the blue function keys, press the [FN] key followed by the appropriate alpha or function key.
Function keys [F1] through [F24] can be used with the Windows Embedded CE operating system or another
application. The additional function keys, [F25] throug h [F30] along with the macros, are not used as p art of the
Windows Embedded CE operating system.
Numeric Keyboard Function Keys
The Numeric keyboards are equipped with up to 24 function keys, including those function keys that are
colour-coded in white print above the function keys. Function keys F25 through F30 can only be accessed by
remapping another key to that function.
To access the white function keys, press the [SHIFT] key followed by the appropriate function key.
Macro Keys
Several of the Omnii keyboards are equipped with a series of macro keys that can be programmed to replace
frequently used keystrokes, along with the function of executable keys like the [Enter/Power] key, the [BACKSPACE] key, any function key and arrow key, etc.
IMPORTANT Refer to “Keyboard Macro Keys” on p age3-35 for details about cre-
ating macros.
59-Key Alphanumeric Keyboard Macro Keys
These keyboards have six macro keys: [M1] to [M6], located on the S to X keys (second-last row of keys).
Page 47
To access a macro key, press the [FN] key followed by the macro ke y.
36-Key Numeric Keyboard Macro Keys
These keyboards are equipped with five macro keys: [M1] to [M5]. These keys are colour coded in blue print
above function keys [F1] to [F5].
To access a macro key, press the [FN] key followed by the macro key.
Numeric Keyboards — Accessing Alpha Keys
On the Numeric Omnii keyboards, all alphabetic characters are printed on the unit plastic in blue typeface
above the keys. Alpha characters are accessed by pressing the [FN] modifier key, then pressing another key
on the keyboard.
The Alpha Modified Numeric 789 keyboard has each blue alphabetic ch aracter assigned as a single
[FN]-shifted character on individual keys. An indicator in the left corner of the taskbar displays the currently
selected character.
The Numeric 123 keyboards have telephone-style alphabetic keys, with the blue alphabetic character s located
in groups of 3 or 4 above each of the numeric keys. To access characters on these keyboards, a few extra
steps are needed, as described below.
Getting To Know Your Omnii2 - 9
Choosing a Single Alpha Character
NOTEThe following examples assume that the [FN] key is enabled as Lock mode in
the One Shot screen (accessible through the Control Panel Keyboard icon). In
Lock mode, pressing the [FN] key once locks it on. Refer to “Keyboard One
Shot Modes” on page 3-34 for details.
The examples below illustrate how to access A, B and C, all of which are printed in blue characters above the
numeric key [2]. The letters you choose appear in the softkey bar as you press the numeric key, providing a
visual indicator of which letter will be displayed on the screen.
To choose the letter a:
•Press the [FN] key, and press the numeric key [2].
•Press the [FN] key again to unlock or turn it off.
To choose the letter b:
•Press the [FN] key, and press [2] twice.
•Press the [FN] key again to unlock or turn it off.
To choose the letter c:
•Press the [FN] key, and press [2] three times.
•Press the [FN] key again to unlock or turn it off.
NOTEKeep in mind that there is a timeout of one second between key presses when
sequencing through the alphabetic characters on a key. If you pause longer
than one second between key presses, the alphabetic character that is displayed at that time will be entered.
Selecting Uppercase Letters
To display a single capital letter, press the [SHIFT] key first, then the letter you want.
Page 48
2 - 10Omnii Hand-Held with Windows CE 6.0 User Manual
To access CAPS LOCK mode, press [FN] + [SHIFT]. In this state, if you press a numeric key, the number is
displayed rather than the normal shifted function of tha t ke y. Press [FN] + [SHIFT] again to turn the CAPS
LOCK mode off.
The Keypad Backlight
The intensity of the keypad backlight and the conditions under which this backlight is activated can be configured using the Keyboard icon in the Windows Embedded CE Control Panel. The behaviour of the keypad
backlight is tailored in the Keyboard Properties dialog box. Refer to “Keyboard Backlight” on page 3-33 for
details about this option.
NOTEKeep in mind that this option may be restricted to supervisory use only.
The Display
The Omnii is equipped with display backlighting to improve character visibility in low light conditions. The backlight switches on when a key is pressed.
Adjusting the Display Backlight
The behaviour of the display backlight and the intensity of the backlight can be specified in the Display Properties dialog box in the Control Panel.
NOTERefer to “Backlight” on page 3-24for details about the Display Properties
dialog box.
Calibrating the Touchscreen
If your Omnii touchscreen has never been calibrated, or if you find that the stylus pointer is not accurate when
you tap on an item, use the Stylus Properties dialog box in the Control Panel to recalibrate the screen.
•In the Control Panel, choose the Stylus icon to display the Stylus Properties window.
•Select the Calibration tab, and then choose the Recalibrate button.
•Follow the directions on the calibration screen to calibrate the screen.
Page 49
Indicators
3. Radio Status
4. Scanner Status
1. Battery Charge Status
2. Operating System Status
1
2
3
4
The Omnii uses LEDs (Light Emitting Diodes), onscreen messages, vibrations, and audio tones as indicators.
LEDs
The Omnii is equipped with four coloured LEDs. This section outlines what these LEDs indicate.
IMPORTANTIf an LED is illuminated in red, the operator should be cautious as
Getting To Know Your Omnii2 - 11
this generally indicates an abnormal operating condition or active
laser emission.
Figure 2-3
LED Status Indicators
Battery Charge Status LED
The far left LED is reserved for battery charge status. This indicator is active even when the hand-held is
inserted in a docking station (and in suspend mode) so that the charge status of the battery can be
detected easily.
Charge LED BehaviourFunction
OFFExternal power not detected.
Solid GreenBattery charging complete.
Flashing GreenCharge in progress.
YellowCell temperature out of range for charge.
Solid RedUnable to charge battery.
Operating System Status LED
The second LED indicates system notifications and operating system status. It is also available for user-loaded
custom Windows Embedded CE applications.
Page 50
2 - 12Omnii Hand-Held with Windows CE 6.0 User Manual
Operating LED BehaviourFunction
OFF when unit is in Suspend or
Shutdown.
Solid YellowThe unit is powering on.
Fast Flashing YellowThe unit is entering Suspend mode.
Flashing YellowThis LED is controlled by the Microsoft NLED
Radio Status LED
The third LED from the left indicates that the GPS radio is enabled or that the WWAN radio is enabled.
Radio Traffic LED BehaviourFunction
OFFThe radio is disabled.
Slow Flashing BlueThe radio is enabled and active.
Scanner Status LED
The fourth (far right) LED indicates scanner status.
OFFThe scanner is not in use.
Normal operating status.
api.
Scan LED BehaviourFunction
Solid Red during scanScan in progress.
Solid Green after decode
OFF when scan ended
Flashing RedUnsuccessful scan.
Onscreen Indicators
The taskbar at the bottom of the screen displays a variet y of system status indicators, includ ing the Input Panel
button if you have chosen to show that option in the Taskbar and Start Menu settings.
Successful scan.
Page 51
Getting To Know Your Omnii2 - 13
GoodNo Radio
Reception
Weak
ReceptionLink
Figure 2-4
Taskbar
The taskbar changes dynamically, and only those icons that are applicable are displayed. For example, if a
radio is not installed in your Omnii, the radio signal icon is not displayed in the taskbar.
®
Windows
Start Button
If you are using the touchscreen, you can either tap the Windows icon at the bottom lef t of the screen, o r press
the [Windows] key to display the Start Menu, and then tap on the desired application.
Modifier Key Indicators
[SHIFT], [CTRL], [ALT], [FN] and [SYM] are modifier keys that have onscreen indicato rs to show when a key is
active or locked. If a modifier key is pressed once to activate it, the key is displayed in the t askbar, for example,
pressing the [FN] key once displays FN in the taskbar. If a modifier key is pressed twice, it is locked on and the
onscreen indicator is displayed with underlined letters in the taskbar, for example, pressing [FN] twice displays
FN in the taskbar.
Power
The battery shaped icon displayed in the taskbar provides quick access to the charge state of the battery.
Tapping on the icon once will show the percentage charge left in the battery. Tapping on the icon twice opens
the Power Properties menus (see “Power Properties” on page 3-44), where you can set the low battery warnings levels, and time to enter Suspend.
If the Omnii is using external AC power, an AC icon is displayed in the taskbar.
802.11 Radio Signal Quality
Increasing radio signal quality is represented by longer, filled bars within this icon.
WWAN Radio Signal Quality
Wireless WAN icons in the taskbar indicate the status of your wide area network connection. For details, see
“Taskbar Icons” on page G-3.
Page 52
2 - 14Omnii Hand-Held with Windows CE 6.0 User Manual
Combo Charger &
Combo Docking Station
Quad Docking StationPowered Vehicle Cradle, Desktop Dock
& Snap Module
OPEN
LOCK
SD Cover
microSD Card Slot
SIM Card Slot
Docking Device
When a hand-held is inserted in a docking station, charger or cradle, an associated icon appears in
the taskbar.
Bluetooth Radio
This icon displayed in the taskbar represents the installed Bluetooth radio.
Input Panel
You can tap the Input Panel icon to activate the soft keyboard application.
Audio Indicators
The Omnii supports several audio options, including Bluetooth. The optional rear speaker can be used for
system (Windows) sounds and .wav files. When a re ar speaker is absent, those sounds are route d to the front
receiver. The beeper provides a variety of sounds and can be configured to emit a sound when a key is
pressed, a keyboard character is rejected, scan input is accepted or rejected, an operator’s entry does not
match in a match field or the battery is low. The volume rocker button is located on the left side of the
hand-held. Information on configuring sounds is detailed in “Volume & Sounds Properties” on page 3-79.
Vibrations
You can set the Omnii to vibrate when a successful or unsuccessful barcode scan is performed. See “Scan-
ners” on page 3-55.
Inserting the microSD Card and SIM Card
There are two slots available in the battery compartment — the lower slot is provided for a microSD (Secure
Digital) card, which provides additional non-volatile memory to your Omnii, and the upper slot is for a SIM
(Subscriber Identity Module) card, which allows access to the Voice option, access to the Internet, and so on.
Inserting the Cards
•Switch off the power to the Omnii.
•Remove the battery.
Page 53
Getting To Know Your Omnii2 - 15
icro
M
OPEN
LOCK
•Use a Phillips screwdriver to remove the SD cover screw. Flip the cover open or remove it.
For a microSD card:
•Slide the microSD card door to the left to unlock it. Flip it open.
•Slide the microSD card into the guides on the SD card door.
•Close the microSD card door, and slide it to the right to lock it.
For a SIM card:
•Slide the SIM card metal door latch to the right to unlock it, then flip the door open.
•Slide the card into the guides on the SIM card door.
•Swing the hinged door back down into place, and slide th e me tal door latch to the left to lock it.
Scanners and Imagers
IMPORTANTIt is critical that you review the “Laser Warnings” in the Omnii
NOTETo enable a newly-installed imager or scanner, press and hold down the [FN]
key and the [Enter/Power] key simultaneously for a minimum of three
seconds.
If your unit has a [Power] button, press and hold down the [FN] key and the
[Power] button for a minimum of three seconds.
The Omnii supports a wide range of scanner options to address a variety of user application requirements.
Refer to the following sections for detailed information:
•Scanner list and specifications: Appendix D: “Internal Imager & Scanner Specifications”.
•Configuration: “Scanners” on page 3-55 and “Manage Triggers” on page 3-40.
•“Scanning Techniques” on page 2-16 outlines the mechanics of a successful scan.
Hand-Held Computer Regulatory & W arranty Guide (PN 8000191)
before using any of the scanners described in this chapter.
For detailed scanner specifications and decod e zone t ables, refe r to
•Imager Settings: Appendix B: “Imager & Camera Settings”.
•“Troubleshooting” on page 2-17 provides some helpful suggestions sh ould the scan fail.
Scanner types include:
•Long Range: reads large 1D barcodes (55 mil) at long distances (up to 3m).
•Standard Range/High Performance: reads damaged or low contrast regular 1D barcodes (5 - 55mil) at
medium distances (up to 1m).
•Extended Range: reads regular 1D barcodes (5 - 55mil) at short to medium distances (1m), as well as
large 1D barcodes (e.g. 55 mil) at long distances.
•1D Imager: reads regular 1D and PDF417 barcodes at short to medium distances.
•EA11 2D imager: reads 1D and 2D barcodes including damaged and low contrast regular 1D barcodes;
smallest barcode at 5 mil with a minimum read distance to 2.8 in. / maximum read distance of 5.1 in.;
largest barcode at 40 mil with a minimum read dista nce of 3.1 in. / maximum distance of 32.4 in.
•EA20X 2D imager: reads 1D and 2D barcodes including damaged and low contrast regular 1D barcodes;
shortest barcode at 6 mil with a minimum read distance of 6.1 inches / maximum read distance of 9.1
inches; longest barcode at 40 mil with a minimum read distance of 5.1 inches / maximum read distance of
49.2 inches.
•SE4600LR imager: captures digital images for transmission to a decoder to decode a barcode of any
format supported by the decoding software. Uses laser aiming, LED illumination, and CMOS sensors to
capture barcode images over an extended range and under a wide variety of lighting conditions.
Basic Scanner Operations
•Turn the hand-held on. Wait until the unit has booted up completely.
•Aim at the barcode and press the scan key or the trigger. A sca n beam and a warning indicator app ear until
a successful decode is achieved or six seconds have elapsed.
Scanning Techniques
•Hold the scanner at an angle. Do not hold it perpendicular to the barcode.
•Do not hold the scanner directly over the barcode. In this position, light can reflect back into the scanner
exit window and prevent a successful decode.
•Scan the entire barcode. If you are using a 1D or PDF laser scanner, make certain that the scan beam
crosses every bar and space on the barcode, including the margins on either end of the symbol.
•If you are using a 2D imaging scanner , make certain the red, oval shaped framing mark is centered within
the barcode you want to scan.
•When using imaging scanners, do not move the scanner while decoding the barcode. Movement blurs the
image.
•Hold the scanner farther away for larger barcodes.
•Hold the scanner closer for barcodes with bars that are close together.
Page 55
Scanner Status LED, Sounds, and Vibrations
The scanner LED (the far right LED) indicates whether or not your scan is successful. The LED behaves as
follows:
•Scan In Progress: scan LED displays solid red colour.
•Successful Scan: scan LED displays solid green colour and turns off when the scan is ended.
•Unsuccessful scan: scan LED flashes red.
A barcode icon appears on the screen during a scan. While the scanner beam is active, the onscre en message
states: SCANNING. If you want to turn off the onscreen message, disable th e “Scan Indicato r” paramete r in the
Control Panel>Scanners>Options>Display menu.
When the scan is successful, the barcode data is displayed on the scr een until the scan button (or pistol
trigger) is released, but only if the “Scan Result” parameter is turned on in the Control Panel>Scan-ners>Options>Display menu.
You can also enable sounds and vibrations to indicate good and bad scans by enabling those options in the
Control Panel>Scanners>Options>Display menu.
Troubleshooting
Getting To Know Your Omnii2 - 17
If the scanner is not working, investigate the following:
•Is the unit on?
•Check that the barcode symbology being scanned is enabled for the hand-held you are using. Check any
other parameters that affect the scanning procedure or the barcode.
•Check the barcode to make sure it is not damaged. Try scanning a different barcode to verify that the
problem is not with the barcode.
•Check that the barcode is within the proper range.
•Does the hand-held display the warning without scanning? This suggests a hardware problem in the
hand-held.
•Is the laser beam scanning across the barcode?
•Once the scan beam has stopped, check the scanner window for dirt or fogging.
Operating One Dimensional (1D) Internal Laser Scanners
•Turn the hand-held on. Wait until the unit has booted up completely.
IMPORTANTIf an aiming dot is available on the installed scanner, the dot will be
enabled for a configurable time period (including of f), after which no rmal
scanning begins. Refer to “Dot Time (msec)” on page C-5 for details.
Double-clicking the trigger will override the aiming delay and initiate an
immediate scan. Note that the aiming dot is standard on long-r ange and
high visibility internal scanners.
•Aim at the barcode and press the scan key or the trigger. A scan beam a nd a warning indicator appear u ntil
a successful decode is achieved or six seconds have elapsed.
Page 56
2 - 18Omnii Hand-Held with Windows CE 6.0 User Manual
Operating Internal Two Dimensional (2D) Imagers
An imager scanner takes a snap shot of a single barcode or multiple barcodes (at one time). It can find a
barcode regardless of its orientation — that is, even a barcode printed at a 45 degree angle to the hand-held
will be decoded successfully.
NOTEWhen scanning multiple barcodes, ensure that all of the desired barcodes are
within the field of view of the scanner. It is possible that even when all barcod es
are within the field of view, not all of them will be decoded. Only successfully
decoded barcodes are passed to the application program. The application program then issues a warning, asking that you scan the missing barcodes.
When scanning a single barcode, ensure that only the desired barcode is
within the field of view of the scanner.
Because imager scanners generally have a shorter depth of field than laser scanners, some practise may be
required to find the optimal distance from the types of barcodes being scanned. Although the imager includes
illumination LEDs, ambient light will help the imager decode the barcodes, especially if the barcode is far from
the hand-held.
IMPORTANTKeep in mind that the imager scanner is a camera, and the LED illu-
mination is a flash. Glare can be an issue on reflective media such
as plastic coated barcodes, just as glare is an issue for photographers. When pointing at a shiny surface, either shift the barcode to
the side or top, or angle the barcode so that the glare reflects away
from the imager scanner.
Most imagers take several snap shots of the barcode in order to
decode it. It is normal for the LEDs to flash two or three times. Hold
the unit steady between flashes to improve decode performance.
•Turn the hand-held computer on. Wait until the unit has boote d up completely.
•Aim at the barcode and press the scan key or the trigger. Hold the trigger until a successful or failed scan
result is obtained.
•When the scan button or trigger is pressed, a red, oval shaped light (the framing marker) is displayed.
Centre the framing marker in the field — either in the centre of the barcode you want to scan or in the
centre of the area in which multiple barcodes are to be scanned.
The illumination LEDs will flash (typically several times) and a picture of the barcode is taken.
Page 57
Windows Embedded CE 6.0
Navigating in Windows Embedded CE and Applications
Graphic user interfaces such as Windows Embedded CE for portable devices and de sktop Windows (Windows
Vista™, Windows 7, Windows 8, etc.) utilize point and click navigation. An equivalent keyboard shortcut is also
available for every point and click action.
Windows Embedded CE supports the same point and click user interface and keyboard shortcuts as desktop
Windows with one difference — the point and click action is accomplished using a touchscreen rather than a
mouse. Actions can be performed using any combination of keyboard shortcuts or touchscreen tapping. In
those applications that support it, you can also flick and pan your finger to scroll through screens.
Navigating Using a Touchscreen
NOTEIf the touchscreen is not registering your screen taps accurately, the touch-
screen may need recalibration. Refer to “Calibrating the Touchscreen” on
page 2-10.
The Omnii comes equipped with a stylus — a pointing tool that looks like a pen. The stylus is used to select
objects on the touchscreen. You can also use gestures with your fingers. You can use two gestures: pan and
flick. Use left or right flicks to quickly move between tabs of a multi-tab control panel, or to scroll long lists of
options. Use panning by touching and dragging a page that has scrollbars.
Getting To Know Your Omnii2 - 19
NOTETo prevent damage to the touchscreen, use only a finger touch or the stylus
(pen) supplied with your Omnii.
To choose an icon, open a file, launch an applet or open a folder:
•Double-tap on the appropriate icon.
Navigating Using the Keyboard
If you would like to use keyboard input to choose icons and navigate dialog boxes, refer to the table following.
OperationKey or Key Combination
Switch between active
applications
Open task manager[ALT] [ESC]
Move the cursorArrow keys
Open file, folder or icon[Enter]
Exit & Save[Enter]
Close/Exit & Do Not Save[ESC]
Navigate Dialog Boxes[TAB]
[ALT] [TAB]
To move cursor up [SHIFT] [TAB]
To display the contents of the next tab in a dialog box
[CTRL] [TAB]
Page 58
2 - 20Omnii Hand-Held with Windows CE 6.0 User Manual
OperationKey or Key Combination
Select Radio Button/Press Button [SPACE]
Go to Start Menu[Windows]
Keep in mind that unlike a desktop computer, the Omnii does not support key chording (pressing two keys at
the same time). You must press one key followed by the next in sequence.
The Windows Classic Shell Startup Desktop
When the Omnii boots up, the default startup desktop (Windows Classic Shell) is displayed. Any applications
stored in the Startup folder start up immediately.
NOTEThe startup folder is located in \Windows\StartUp and \Flash Disk\StartUp.
Figure 2-5
To access desktop icons:
•Double-tap on the icon to open a window or, in the case of an application icon, launch an application.
On the keyboard:
Omnii Windows Classic Shell Startup Desktop
•Use the arrow keys to highlight the icon, and press [Enter] to launch the highlighted icon.
NOTEIf the arrow keys do not highlight the desktop icons, the desktop may not be
selected. Press [Windows] to display the Start Menu, and select Desktop. Now
the desktop will be “in focus” and the arrow keys will highlight the icons.
Page 59
The Taskbar
The Omnii is equipped with a taskbar at the bottom of t he screen. It disp lays icons throug h which you can view
the battery capacity and radio signal quality of your unit. If the hand-held is attached to a charger, cradle,
docking station, or Snap Module, an associated icon is displayed. In addition, the taskbar displays the application(s) currently running on your unit.
Getting To Know Your Omnii2 - 21
The taskbar also displays active modifier keys: [SHIFT], [ALT], [CTRL], [FN] and [SYM]. Keys that have been
locked “on” are displayed with underlined letters. For example, if you have set the [CTRL] key lock to “on” in
the Keyboard menu and you press the key, it is displayed as an underlined Ctrl in the taskbar. (For detailed
information on modifier keys and keyboard options, see “The Keyboard” on page 2-4).
Using the Taskbar
A tooltip is displayed as each taskbar icon is highlighted. The tooltip provides the status of each icon.
If you’re using the touchscreen:
•Tap and hold on an icon to display the icon's tooltip. Double-tap the icon to open the Control Panel dialog
box associated with the icon. For examp le, double-tap the battery icon to display a dialog box listing the
current battery capacity information.
On the keyboard:
•Press [Windows] to display the StartMenu.
•Choose Shortcuts from the Start Menu, and then press the [RIGHT] arrow key to display the sub-menu.
•Choose System Tray in the sub-menu.
•Use the arrow keys to highlight the icon in the taskbar about which you’d like more information.
•Press [Enter] to display the appropriate dialog box.
Customizing the Taskbar
To customize the taskbar so that it displays only those icons you require:
•In the Start Menu, choose Settings, and then Taskbar.
If you’re using the keyboard:
•Press [Windows] to display the StartMenu.
Page 60
2 - 22Omnii Hand-Held with Windows CE 6.0 User Manual
•Highlight the Settings option, highlight Taskbar in the sub-menu, and press [Enter].
The Taskbar and Start Menu dialog box is displayed.
•Tap on the items you want to activate or deactivate. The check mark indicates active items.
If you’re using the keyboard:
•Highlight the options you want to activate, and press the [SPACE] key to select them. A check mark indicates active items.
The Start Menu
The StartMenu lists the operations you can access and work with. It is available from the startup desktop or
from within any application.
•To display the menu, tap on the Start Menu.
NOTETap on the item in the menu with which you want to work.
If you’re using the keyboard:
•Use the arrow keys to highlight a menu item, and press [Enter], or
If the menu item has an underlined character:
•Type the underlined alpha character. For example, to display the Run dialog box, type the letter r.
Page 61
Programs
Getting To Know Your Omnii2 - 23
•Choose Programs to display a sub-menu of options. The programs displayed will be those resident in the
Windows\Programs folder of the computer.
Figure 2-6
This sub-menu allows you to choose Command Prompt, Internet Explorer, installed applications (e.g., Micro-
soft WordPad), Kiosk Access, Remote Desktop Connection, Wi-Fi Config, or Windows Explorer.
Demo
This folder contains the Scanner Demo, Demo Signature and Demo Sound applications. Scanner Demo can
be used to test how the hand-held reads barcodes. Demo Signature allows you to capture a signature written
on the screen with your stylus and save it to a file. Demo Sound allows you to record and playback sound files.
The Sample Rate and the Bits Per Sample are the rates at which the sound will be recorded. Sounds recorded
at the higher sample rate or bits per sample will be higher quality sound but will require more file storage
space. Lower sample rates and/or bits per sample produces a smaller file, but the sound quality suffers. The
record and play buttons operate the same as any recording device. The X icon deletes the sound and the
diskette icon allows you to save your sound.
Program Sub-Menu
Command Prompt
Command Prompt is used to access the DOS command prompt. At the prompt, you can type DOS command s
such as dir to display all the directories in the drive.
Internet Explorer
The Omnii is equipped with Microsoft Internet Explorer for Windows Embedded CE. You can access the
Internet Options icon through the Start Menu under Settings>Control Panel or by do uble-tapping on the
desktop icon My Device and then, double-tapping on the Control Panel icon.
Microsoft WordPad
WordPad is a basic word processor used to create, edit, and print .rtf, .doc, and .txt files.
Kiosk Access
Kiosk Access allows you to change the appearance and acti on s of th e desktop from the default Windows
Classic Shell to the Kiosk shell.
Page 62
2 - 24Omnii Hand-Held with Windows CE 6.0 User Manual
Remote Desktop Connection
Remote Desktop Connection is an Omnii application used to connect to a Windows Terminal Server so that
you can run a “session” on the Server machine using the hand-held (Windows Embedded CE device).
“Remote Desktop Connection” on page 3-54 provides a website with details about this option.
Wi-Fi Config
The Wi-Fi Config application is used to configure the Omnii 802.11a/b/g/n radio for one or more wireless
network profiles.
Windows Explorer
The Windows Explorer installed on your Omnii is consistent with all Windows Embedded CE devices.
Shortcuts
Figure 2-7
System Tray
If your touchscreen is not enabled, you can use the System Tray option to access the icons in the taskbar at
the bottom of the screen. The taskbar displays indicators such as a radio signal icon. These indicators are
attached to dialog boxes that provide additional information.
•Choose Shortcuts>System Tray.
When System Tray is chosen, the taskbar icons become accessible. To display the dialog box attached to
an icon:
Shortcuts Sub-Menu
•Use the arrow keys to highlight an icon, for example, the Bluetooth icon.
•Press [Enter] to display the Bluetooth menus.
Cycle Tasks
When Cycle Tasks is selected (and the Task Manager is not open), you can cycle through active applications.
To cycle through your active applications:
•Choose Shortcuts>Cycle Tasks, or
•Press [ALT] [TAB].
T as k Manager
The Task Manager allows you to switch to another task or to end an active task. To display the task
manager window:
Page 63
Settings
Getting To Know Your Omnii2 - 25
•Tap on Shortcuts>Task Manager, or
•Press [ALT] [ESC].
The Settings sub-menu includes the following settings: Control Panel, Network and Dial-up Connections and Taskbar and Start Menu.
Figure 2-8
Control Panel
The Control Panel contains applets used to configure hardware, the operating system and the shell. If your
Omnii is running with the Motorola TekTerm application or another applicatio n, additional configuration applets
may appear in the Control Panel.
Network and Dial-Up Connections
The Network and Dial-up Conne ctions window allows you to configure the Omnii network interfaces or execute
an existing configuration. Refer to “Connectivity” on page 1-10 for radio setup details.
Settings Sub-Menu
T askbar and S tart Menu
The Taskbar and Start Menu option displays a dialog box in which you can customize the taskbar, choosing
which options will be displayed. Refer to “Customizing the Taskbar” on page2-21 for additional details about
this option.
Page 64
2 - 26Omnii Hand-Held with Windows CE 6.0 User Manual
Run
Choosing the Run option from the Start Menu displays a dialog box in which you can enter the name of the
program, folder or document you want to open or launch.
Shutdown
The Shutdown menu includes these options: Suspend, Warm Reset and Cold Reset.
Suspend
The Suspend option suspends the Omnii immediately. This is equivalent to turning the hand-held off.
Warm Reset
The Warm Reset option resets the hand-held, leaving all saved files and registry settings intact. Any unsaved
data is lost.
Cold Reset
The Cold Reset option resets the hand-held. Any files not stored in permanent memory are lost; however, the
registry settings are saved.
Page 65
The Kiosk Desktop Shell
Hold the stylus or your finger on the Active Tasks, Favourites, or Notifications Bar,
Favourites Bar
Notifications Bar
Active Tasks Bar
and swipe to the left or right to switch to the next screen.
The appearance and actions of the desktop can be changed by tapping on the Kiosk Shell icon on your
desktop, which activates the Kiosk shell.
NOTEThe Omnii will be reset if you choose to switch shells.
Getting To Know Your Omnii2 - 27
Figure 2-9
Switch to Kiosk Shell
After resetting the Omnii, the desktop appearance will be very different. The programs are accessed with finger
(or stylus) taps and swipes. If there are more applications than shown on one screen, a white animated dot will
be present on the side of the screen in the direction of the next set of icons. Swiping the screen to that direction
will move the display to the next screen.
NOTEAlthough the Desktop appearance default s to the “ Ingenuity” theme, the theme is
not changed using the Kiosk Shell icon. To change themes, open the Shell Settings>Advanced menu in Kiosk Access (see “Shell Settings” on page 3-51).
Page 66
2 - 28Omnii Hand-Held with Windows CE 6.0 User Manual
A different program, Kiosk Access, enables you to customize your computer settings, remove or add shortcuts
to the Favourites Bar and Control Panel, and limit access to various dif ferent comp onents on the comp uter and
the system tray icons for security. For details see “Kiosk Access” on page 3-49. To change your Desktop background, refer to “Shell Settings” on page 3-51.
Active T asks Bar
Open applications are shown in the top bar — the most recently opened is the first icon on the left. Tapping
once on a program icon will maximize the application. This feature replaces the Task Manager of the Windows
Classic Shell.
Date/Time Bar
Tapping once on the date or time will open the Date/Time Properties settings to enable you to change your
settings and time zone.
Favourites Bar
The Favourites Bar replaces the Windows Classic Shell De sktop and S t art Menu . These icons ar e the program
shortcuts from your Windows>Start Menu. Tapping once will open the program. If you tap and hold on an icon,
the application name is displayed.
Notifications Bar
This bar shows the run-time program notifications for Battery, Volume, Wi-Fi, Phone or GPRS, and other notifi-
cations for the programs you are running. This feature replaces the Taskbar of the Windows Classic Shell.
Desktop Minimized View
When an application is opened and maximized, the desktop view is minimized and the Notifications Bar is
shown at the bottom of the screen. Tapping anywhere on the Notifications Bar (except on the SIP) will restore
the Kiosk desktop.
In order to use the SIP, turn on the automatic settings in Control Panel>Input Panel.
Kiosk Access
The Kiosk Access program allows you to open a different program, Kiosk, which enables you to customize
your computer settings, remove or add shortcuts to the Favourites Bar and Control Pane l, and limit access to
various different components on the computer and the system tray icons for security. For details see “Kiosk
Access” on page 3-49. To change your Desktop background, refer to “Shell Settings” on page 3-51.
To open Kiosk:
•Tap on the Kiosk Access icon in the Favourites Bar.
Page 67
Restoring the Windows Classic Shell
The default Desktop appearance and actions can be restored by tapping on the Kiosk Shell icon in the
Favourites Bar.
Getting To Know Your Omnii2 - 29
Figure 2-10
Shell Switch to Windows Classic Shell Desktop
NOTEThe Omnii will be reset if you choose to switch shells.
General Maintenance
Caring for the Touchscreen
The touchscreen is covered with a thin, flexible polyester plastic sheet with a conductive coating on the inside.
The polyester can be permanently damaged by harsh chemicals an d is susceptible to abrasions and
scratches. Using sharp objects on the touchscreen can scratch or cut the plastic, or crack the internal conductive coating. The chemicals listed below must not come into contact with the touchscr een:
•mustard
•ketchup
•sodium hydroxide
•concentrated caustic solutions
•benzyl alcohol
•concentrated acids
If the touchscreen is used in harsh environments, consider applying a disposable screen protector (RV6105).
These covers reduce the clarity of the display slightly but will dramatically extend the useful life of the touchscreen. When they become scratched and abraded, they are easily removed and replaced.
Do not to expose the touchscreen to direct sunlight for prolonged periods of time. If this is unavoidable, use a
UV screen protector to extend the life of the screen.
Page 68
2 - 30Omnii Hand-Held with Windows CE 6.0 User Manual
Cleaning the Omnii
IMPORTANTDo not immerse the unit in water. Dampen a soft cloth with mild
detergent to wipe the unit clean.
To prevent damage to the touchscreen, use only your finger or the
stylus (pen) supplied with your Omnii.
•Use only mild detergent or soapy water to clean the hand-held unit.
•Avoid abrasive cleaners, solvents or strong chemicals for cleaning. The Omnii has a plastic case that is
susceptible to harsh chemicals. The plastic is partially soluble in oils, mineral spirits and gasoline. The
plastic slowly decomposes in strong alkaline solutions.
•Exposure to aircraft de-icing fluids can degrade the plastics on Omnii. If the Omnii is used near aircraft
de-icing environments, regular rinsing with water is recommended.
•To clean ink marks from the keypad and touchscreen, use isopropyl alcohol.
Page 69
CHAPTER 3CONFIGURATION
CONFIGURATION3
Overview of Software...........................................3-5
The Omnii programs and applications are accessed through two main areas from the Desktop Start Menu:
Programs and Settings>Control Panel. This chapter details the configuration for the major software from both
areas, listed alphabetically.
Motorola Software Advantage
Motorola Software Advantage is a collection of applications and features designed to support system administrators and end users. These tools enable enterprises to customize the product to meet their needs and to
maximize productivity.
•AGPS
•App Launch Keys
•Battery Health
•Bluetooth Manager
•Compass
•Dr. Debug
Configuration3 - 5
•Manage Triggers
•PartnerUp
•Kiosk
•Scanner
•Total Recall
•TweakIt
•WiFi Config
•WiFiConnect A.R.C.
Microsoft Software
Windows CE 6.0 R3 is a 32-bit, real-time, multitasking Operating System. The OS features a small footprint,
with compatibility to port existing Win32 applications and Touch & Gesture support.
Some of the major Windows CE 6.0 R3 components are:
•Control Panel, where both Motorola Advantage and Microsoft applications are listed
•Flash Lite
•Internet Explorer Embedded
•Microsoft WordPad
•Remote Desktop Connection
•Windows Explorer
Page 74
3 - 6Omnii Hand-Held with Windows CE 6.0 User Manual
The Control Panel
The Windows Embedded CE Control Panel provides a group of applications through which you can set a
variety of system-wide properties, such as power, keyboard sensitivity, network configuration, system backup,
desktop appearance, and so on.
When the Omnii boots up, the startup desktop (Windows Classic Shell) is displayed, and any applications
stored in the Startup folder start up immediately.
To access the Control Panel:
•Press the [Windows icon] to display the Start Menu.
•Tap on Settings>Control Panel.
If you’re using the keyboard:
•Press the [Windows icon] to display the Start Menu.
•Highlight Settings in Start Menu, and press the [RIGHT] arrow key to highlight the Control Panel.
•Press the [Enter] key.
The Control Panel folder contains icons used in the setup of your Omnii.
Figure 3-1
Control Panel Icons
Control Panel Applications
The Control Panel provides a group of applications that allow you to customize and adjust settings on your
Omnii. This section shows the related icons in the Control Panel and gives a brief description of each.
App Launch Keys
By mapping keys to applications using this program , you can then launch those applications from a single
key-press.
Page 75
Configuration3 - 7
Bluetooth
Opens the Bluetooth Manager which provides options for configuring various Bluetooth peripherals. It also
provides the capability to use a Bluetooth-enabled cellular phone as a data modem to exchange information
with other Bluetooth devices and provide network access.
Certificates
This program provides access to the Certificates Manager and Stores. The Certificates Manager displays the
certificates in the Windows Certificates Store, an d allows you to import, delete, and view these certificates.
“Compass” on page 3-7 directs you to the appropriate setup information.
Compass
The internal compass can be calibrated to indicate in which direction the unit is pointed.
Date/Time
Allows you to set the current Month, Date, Time, and Time Zone on your unit.
Dialing
Specifies dialin g settings, including area code, cou ntry code, dial type an d the code to disable call waitin g. You
can store multiple patterns — for example, Work, Home, and so on using this dialog box.
Display
Changes the display backlight and the appearance (colour scheme) on the unit desktop.
Dr. Debug
Provides both error diagnostic and troubleshooting tools.
Error Reporting
Allows you to enable or disable Microsoft error reporting prompts.
GPS Settings
Allows you to enable and configure GPS operation.
Imagers
The Imagers applet is used to create, modify, delete, and activate imager settings. This icon is only present
when the appropriate imager is installed. For detailed information, see Appendix B: “Imager & Camera
Settings”.
Input Panel
Provides the framework for a Microsoft Soft Input Panel (SIP) should you need to design your own SIP, or
change some soft keyboard options.
Internet Options
Provides options to configure your Internet browser. You can determine items such as the default and search
page that the browser applies when conne cting to the In ternet, the cache size, the Internet conn ection options,
and the security level that is applied when browsing.
Page 76
3 - 8Omnii Hand-Held with Windows CE 6.0 User Manual
Keyboard
Toggles character repeat on and off and specifies delay and rate for repeated characters. It also allows you to
adjust the keyboard backlight threshold and intensity, and many other functions.
Manage Triggers
This utility allows you to define buttons as triggers for different devices. For example you would use this utility
to configure a button for the scanner, RFID reader, and camera.
Microphone
Enables you to adjust the gain for the specific microphones associated with your hand-held.
Network and Dial-up Connections
Displays network interfaces and allows new dial-up and VPN interfaces to be created. It also allows Windows
configuration of the interface. Refer to “Connectivity” on page 1-10 for details.
Owner
Provides fields in which you can specify owner information. A Notes tab allows additional information to be
entered and displayed when the unit is powered up. Network ID tab information is used to access network
resources. (This information should be provided by your System Administrator.)
PartnerUp
This app displays a number of pre-loaded applications. By t apping on an application in the list, you are taken to
the associated web site and allowed to install the application .
Password
Allows you to assign a password to restrict access to elements of the unit. Once assigned, password access
cannot be circumvented so it is important that you write down your password and keep it in a safe place.
PC Connection
Enables direct connection to a desktop computer ( or through ActiveSync — see “Dat a T ransfer” on page 1-10).
Selecting the Change Connection button allows you to change the type of direct connection to your PC.
Power
Displays battery pack power status. (Alternately, battery status can be accessed through the taskbar.) Additional tabs allow you to determine suspend states and specify a suspend thr eshold.
Kiosk
Kiosk enables you to customize your computer settings, remove or add shortcuts to the desktop and Control
Panel, and lock down access to various different components on the computer and the system tray icons for
security. With Kiosk and Kiosk Shell (see “The Kiosk Desktop Shell” on page 2-27) you can customize the
entire look and feel of your User Experience.
Quick Defrost
The optional Heater Control feature for the OmniiXT15f freezer models is used in cold e nvironment s to prevent
condensation from developing on or inside the Omnii. Refer to Append ix F: “Omnii XT15f Freezer Variants” for
detailed information.
Page 77
Configuration3 - 9
Region and Language
Allows you to specify the local language that is to be displayed on the hand-held scre en along with the format
of numbers, currency, time and date for your region.
Remove Programs
Lists the programs that can be removed from your unit. To remove a program, select it and then click on the
Remove button.
Scanners
Provides scanner parameters and the barcode symbologies that the Omnii barcode scanner will successfully
read.
Screen Rotation
This feature enables you to change screen orientation into either landscape, portrait, or both modes.
Storage Manager
Allows you to view information about the storage devices that are present, such as SD-MMC flash cards. For
details, see “Storage Manager” on page 3-63.
Stylus
Adjusts how Windows Embedded CE recognizes your double-tap (as slow or rapid successive taps). In the
Calibration tab, you can recalibrate your touchscreen by tapping on the Recalibrate button and following the
directions on the screen.
System
You can display the system and memory properties, as well as create your device name. In the Memory tab,
you can allocate memory between storage memory and program memory.
System Properties
Identifies the computer’s software and hardware components, indicating which compone nts are installed, their
version or part numbers, and whether they are enabled or disabled.
T otal Recall
Provides access to a backup/restore and deployment utility to maintain applications and settings over cold
reboots and for multiple devices.
T we akIt
Allows you to change Advanced System Settings (interface, network, and servers), User System Settings
(display font size), and provides the Registry Editor.
Volume & Sounds
Allows you to adjust the volume of the sound emitted to indicate events like warnings, key clicks, and screen
taps. You can also configure system (Windows) sounds and .wav files.
Wireless WAN
Provides access to technology like GSM/GPRS, which allows wide area networking capability such as internet
browsing via GSM/GPRS. It also provides access to the Phone API. For detailed information, see Appendix G:
“Wireless Wide Area Network (WWAN) Settings”.
Page 78
3 - 10Omnii Hand-Held with Windows CE 6.0 User Manual
App Launch Keys
The App Launch Keys icon allows you to map a key to an application so that you can then launch the application from a single key-press.
•In the Control Panel, choose the App Launch Keys icon.
To assign an application key:
•Tap the Add button.
•Press the key you want to use to launch an application. (If an unsupported key is pressed, a message
appears on this screen letting you know.)
The cursor moves to the App field and a new screen is displayed where you can choose the application to
which you want to assign the application key. If you need to, you can Browse through the information in your
Omnii until you locate the application you want to launch.
•Once you’ve selected the file you want to map, tap on OK.
The cursor moves to the Data field. You can use this field if you need to need to define command line parameters for your application. If you don’t want to assign any parameters, you can leave the Data field blank. If, for
example, you want to assign an application launch key to launch the WordPad application, you can leave this
field blank. If you want to assign an application launch key that will open a specific document in the WordPad
application, you need to browse to and choose that document while the cursor is in the Data field.
•Tap on OK.
Page 79
•If you need to Edit, Remove or Add another App Launch Key, you can do it from this final screen. Other-
wise, tap on OK to save your Application Launch Key.
•To launch the application you chose, pres s the application key you assigned.
Bluetooth® Setup
Bluetooth is a global standard for wireless connectivity for digital devices and is intended for Personal Area
Networks (P AN). The technology is based on a short-range radio link that operates i n the ISM band at 2.4 GHz.
When two Bluetooth-equipped devices come within a 10 metre (32 ft.) range of each other, they can est ablish
a connection. Because Bluetooth utilizes a radio-based link, it does not require a line-of-sight connection in
order to communicate.
Configuration3 - 11
It is possible to communicate with a variety of Bluetooth peripherals, including GSM/GPRS handsets, scanners, printers, and so on.
Motorola provides built-in support for:
•GSM/GPRS universal handset
•Bluetooth printer
•Bluetooth headset
Keep in mind that Bluetooth and IEEE 802.11g radios both operate in the 2.4GHz band. Although the Omnii
includes features to minimize interference, performance of the system will not be optimal if you use both radios
simultaneously. Typically, when both radios operate in the hand-held at the same time, they cannot transmit
simultaneously — this has a negative impact on overall system throughput. To minimize the impact on the
backbone 802.11 network, Motorola recommends using Bluetooth peripherals that have low transaction rates
(such as printers and scanners).
Bluetooth peripherals are configured by choosing the Bluetooth icon in the Control Panel. In addition, review
the manual shipped with your Bluetooth device to determin e the m ethod us ed to associa te with th e Omnii ho st.
NOTEThe Bluetooth radio uses an internal antenna.
•In the Control Panel, choose the Bluetooth icon to display the Bluetooth Manager screen.
Page 80
3 - 12Omnii Hand-Held with Windows CE 6.0 User Manual
The BluetoothManager allows users to search, pair and connect to other Bluetooth devices within their
personal area network.
The Bluetooth radio is disabled by default. Before you begin the setup process:
•Tap on the Mode tab, and tap in the check box next to Turn on Bluetooth. Tap on OK.
When the radio is enabled, a Bluetooth icon appears on the taskbar at the bottom of the screen. It is ready
for setup.
Paired
This tab lists all paired devices and their corresponding services. The format of the name is <Device
Name>:<Service Name>. Additional information may appea r in this screen such as the Port Numbe rs for Serial
Profiles service.
To learn how to scan for devices to pair, review “Device” on page 3-13.
NOTEIf a service is actively paired and connected, the device and its services are dis-
played in bold typeface in this list.
•Tap on an item in the Paired tab to display an associated pop-up menu.
The displayed menu depends on the type of the service chosen.
Query Services and Remove Commands
•Query Services displays a Services dialog box where a pairing service is chosen.
•Remove unpairs the highlighted service and deletes the entry from the tab.
Page 81
Device
Configuration3 - 13
OBEX OPP (Object Exchange-Object Push Profile) Commands
The OPP defines two roles — a Push Server and a Push Client. Push Server is the device that provides an
object exchange server. Push Client is the device that pushes and pulls objects to and from the Push Server.
OBEX OPP contains the following unique menu option:
•Send File displays an Open File dialog box where the file to be sent can be selected. When the transmis-
sion begins, another dialog box tracks the progress of the file transmission.
HSP/HFP (Headset Profile/Hands-Free Profile) Service Commands
The HSP (Headset Profile) allows users to connect their device to Bluetooth enabled headsets and other
audio devices.
HSP/HFP services provide the following unique menu options:
•Connect Audio establishes an audio connection to the Bluetooth headset.
•Disconnect Audio disconnects the audio connection from the Bluetooth headset.
•Volume Control displays a dialog box where the headset and microphone volume can be adjusted.
In this tab, users can discover and display Bluetooth devices.
Discovering and Removing Devices
Scan discovers Bluetooth devices in range of the Omnii and lists them in this tab. Any existing devices previously discovered and listed will also be displayed.
Clear removes all Bluetooth devices listed except those with currently paired and connected services.
NOTETo limit the number of devices listed to a particular type of device, refer to “Filter-
ing By Class of Device (COD)” on page 3-14, next section.
Page 82
3 - 14Omnii Hand-Held with Windows CE 6.0 User Manual
Filtering By Class of Device (COD)
This menu allows you to filter the displayed devices by their COD. If, for example, you choose Computer from
this menu, only the devices that have the matching Computer COD value will be displayed. Choosing All lists
all detected devices.
Device Pop-up Menu
The Device pop-up menu allows you to pair a device, update a device name or delete a device from the list.
Pair begins the pairing process by querying the services and profiles of the discovered device. An authentica-
tion dialog box is displayed the first time a Bluetooth device is paired.
Refresh Name repeats the device name inquiry, updating the name . This command is useful if a device is listed
without a name (unknown), or if a device name has been changed remotely.
Delete removes this device from the list.
Pairing a Device
To pair devices:
•Follow the manufacturer’s instructions to place the remote device in pairing mode.
•Choose the Devices tab and Scan for devices in your area.
•When the scan is complete, tap on the device to which you want to pair.
•In the pop-up Device menu, tap on Pair.
An Authentication dialog box is displayed.
Page 83
Configuration3 - 15
•If the remote device has authentication enabled, type the PIN in this dialog box.
•To proceed without authentication, tap on Next.
After entering the device PIN, the Services dialog appears with a list of services available for that device.
•Click in the check box to the left of the service to activate it.
•Click on Done.
Services that require more information present a configuration dialog box. Serial Profile is an example.
This dialog box offers a number of additional options such as enabling Encryption and selecting four different
Modes: Serial, ActiveSync,Scanner, and Printer Port.
Serial is used for simple serial port communication.
ActiveSync is for ActiveSync-over-Bluetooth.
Page 84
3 - 16Omnii Hand-Held with Windows CE 6.0 User Manual
Scanner is used to create a connection to a barcode scanner. A serial conn ection is created, then the
Scanner Services is notified of the connection so that the incoming barcode scan will be forwarded directly to
Scanner Services.
Printer Port must be chosen here if you want to communicate with a paired Bluetooth printer. For further
details, see “Mode” on page 3-17.
•Once you’ve completed the information, tap on Next and then in the Services screen, click on Done.
Servers
When a remote Bluetooth device initiates a Bluetooth connection to the Omnii, the remote device is considered
the Bluetooth master and the hand-held, the Bluetooth slave. In order for the remote device to connect to the
hand-held, the Omnii must offer a service in the form of a server. The Servers tab allows these services to be
enabled and configured. There are three server services available: Serial, Scanner and OBEX OPP.
Serial server enables the Serial Port Profile server; a Serial Port can be selected from the drop-down menu.
You can assign either a BSP or a COM prefix from the drop-down menu. BSP (Bluetooth Serial Port) was
created by Microsoft to allow Bluetooth to have its own serial prefix in order to free up virtual COM prefixes as
these are limited and are widely used.
NOTEEven after a Serial Port Profile server is created, an application must open the
created port before a remote device can connect.
Scanner server enables a Serial Port Profile server and then relays it to the Scanner Service (SCS). This is
used for Bluetooth barcode scanners that operate in client mode . SCS opens the server port and handles the
scanner input.
OBEX OPP server enables the Object Push Profile server . A warm reset must be performed on the Omnii af ter
a change is made to this option. The OPP Server allows other Bluetooth devices to send files to this device.
•Tap on the check box to activate the server.
Page 85
Mode
Configuration3 - 17
Turn on Bluetooth activates the Bluetooth radio.
Discoverable determines whether the Omnii is visible or invisible to other devices.
Printer Port allows you to assign and enable a virtual outgoing COM port selected from the drop-down menu
to communicate with a paired Bluetooth printer . Kee p in mind that when a por t is chosen, the printer must be on
and connected to the chosen port for a remote device to be able to connect.
About
•Select a port within the Printer Port drop-down list, e.g. BSP1:
•Check the Printer Port check box.
•Open the Device tab and tap on Scan.
•Tap-and-hold each Bluetooth Printer device entry and then select Pair , key-in the Passcode (if needed)
and then tap Done. DO NOT select any services!
•Close the Bluetooth Manager.
•Select the Bluetooth device to print to — you will need to key-in (or programmatically raise) the following
key sequence [CTRL] [ALT] [F1].
•You can now select the Bluetooth device to which you wish to print.
Allow Bluetooth to wake system allows remote Bluetooth devices to wake the Omnii by requesting a Blue-
tooth service that requires host intervention. This feature can also be used when the Omnii is waking from suspend to significantly to reduce the initialization time of the Bluetooth system.
Device Name displays the broadcasted nam e of the hand-held. The name can be changed in the System
Properties applet: Start>Settings>Control Panel>System icon>Device Name tab.
Page 86
3 - 18Omnii Hand-Held with Windows CE 6.0 User Manual
Local Address displays the MAC address (BD_Addr) of the Bluetooth chip.
HCI Version & LMP Version display the version of the chip firmware.
Component indicates the version of the Motorola Bluetooth Subsystem (the manager, driver s, etc).
Profiles lists the supported profiles on this specific Omnii.
The
Bluetooth
The following steps describe how to set up an Internet data connection using a GSM cellular telephone with
Bluetooth. The Omnii communicates via Bluetooth to the cell phone, which then accesses a WAN (Wide Area
Network) and transfers data using GPRS.
1. Enable the Dial-Up Networking service in the cell phone.
2. Make the phone discoverable.
3. Pair the phone service with the Omnii Dial-Up Networking service using the Bluetooth Manager. (For
instructions on pairing devices, refer to “Pairing a Device” on page 3-14.)
4. To set up the Internet parameters, choose the Network And Dial-up Connections icon from the
Control Panel.
GPRS WAN Connection
5. Tap on Make New Connection.
6. In the Make New Connection dialog box, choose Dial-Up Connection . Enter a name for your GPRS
network connection.
Page 87
Configuration3 - 19
7. Choose the Next button to display the Modem dialog box.
8. In the drop-down menu labelled Select a modem, choose the name of the modem with which you want
to connect, and then choose the Configure button to display the Device Properties dialog box.
The Omnii communicates via Bluetooth to your Bluetooth equipped cellular telephone and retrieves the
parameters for the Device Properties dialog box. Omnii then disconnect s.
9. Under the Call Options tab, turn off Cancel the call if not connected within, and press [Enter] to
save your changes.
10. In the Modem dialog box, choose the Next button to display the Phone Number dialog box.
Page 88
3 - 20Omnii Hand-Held with Windows CE 6.0 User Manual
The phone number you enter is network carrier dependent. Once you’ve specified all the necessary information, choose the Finish button.
11. In the Control Panel, choose the Dialing icon.
12. The values in the Dialing Properties dialog box need to be edited according to your network carrier
specifications.
Once you’ve edited this dialog box to reflect your network carrier requirements, press [Enter] to save
your changes.
13. At this point, return to the Control Panel, and choose the Network and Dial-up Connections icon.
14. In the network connection window, the new network configuration — in this case, New Connection is
displayed. Tap on the new icon.
When you tap on your new connection, an onscreen message indicates the status of your connection:
connected, disconnected, error messages, and so on.
Page 89
Certificates
This program provides access to the Certificate Manager and Stores. The Certificate Manager displays the
certificates in the Windows Certificate Store, and allows you to import, delete, and view these certificates.
Omnii checks that the certificate has been digitally signed by a certification authority that the Omnii explicitly
trusts. This option is used in conjunction with 802.1x authentication to enhance Omnii security.
•In the Control Panel, choose the Certificates icon.
Your Omnii has certificates preinstalled in the computer. My Certificates is the repository for the device’s
personal certificate store, Other Authorities is the repository for the intermediate certificate store, an d Trusted Authorities is the repository for the Trusted Root certificate store.
Configuration3 - 21
You can import or remove certificates, and view certificate information for any listing, including names, dates,
serial numbers, etc.
For a detailed description about Certificate setup for both the server and client-side devices (Omnii Hand-Held
Computers), refer to the following website:
Like all compasses, the Omnii digital compass indicates the direction in which the unit is pointed. If you find
that the compass is inaccurate, you may need to calibrate it.
•In the Control Panel, choose the Compass icon.
•Tap on the Calibrate button and follow the directions to calibrate the compass. Make certain that
you perform the figure 8 indicated in the instructions in a fairly wide loop to better ensure
successful calibration.
Page 90
3 - 22Omnii Hand-Held with Windows CE 6.0 User Manual
When the compass recalibration is complete, a message appears on the Omnii screen indicating
successful calibration.
NOTEThe accuracy of the digital compass is affected by the following:
a) close proximity to large magnets or metal structures, and
b) internal scanner/imager activation.
Data Transfer between Omnii and a PC
Data transfer options vary slightly depending on the type of operating system installe d in your PC.
For Windows XP SP2 operating systems or earlier, Microsoft
to connect your Omnii to PCs.
®
If the Windows Vista
to transfer data between your Omnii and your PC.
By using a Snap Module or Desktop Docking St ation with your Omnii, you can conn ect to a PC with a cable to:
•View Omnii files from Windows Explorer.
•Drag and drop files between the Omnii and the PC in the same way that you would between PC drives.
•Back up Omnii files to the PC, restore them from the PC to the hand-held again, etc.
Uploading Data in a Docking Station
The Desktop Docking Stations allow your hand-held to upload transaction data to a server computer when a
radio link is not available. When the Omnii is properly inserted in a docking station, a dock icon is displayed in
the taskbar at the bottom of the unit screen. For detailed information, refer to “Desktop Docking Stations -
Models ST4002 and ST4003” on page 4-11.
, Windows 7 or later , operating system is installed in your PC, ActiveSync is not required
®
ActiveSync® connectivity software can be used
Page 91
Using Microsoft ActiveSync
NOTEIf you use a serial port to connect devices like the Omnii to your desktop computer,
the connection may not succeed because ActiveSync has trouble connecting at
non-default baud rates.
To work around this problem, set the ActiveSync baud rate on the desktop to use the
same baud rate as the device. You can set the baud rate by ed iting the registry on the
desktop host computer, as detailed in the steps outlined at the following website:
http://support.microsoft.com/kb/324466
To install ActiveSync, follow the step-by-step instructions provided with the program setup wizard. For details,
go to the following website and type the name into the search box:
If you are running Windows Vista, Windows 7, or later, your data transfers do not require ActiveSync.
Instead, you will need to download Windows Mobile Device Center. For instructions, go to the following
website and type the name into the search box:
To transfer data between your PC and your hand-held:
•Tap on Start>Computer to display the drives. The Omnii will be visible here.
•Open drives, files and folders as you would on your PC.
Display Properties
•In the Control Panel, choose the Display icon.
Background
•In the Display Properties dialog box, open the Background tab. This dialog box allows you to customize
your background image.
Page 92
3 - 24Omnii Hand-Held with Windows CE 6.0 User Manual
Appearance
•In the Display Properties dialog box, open the Appearance tab. This dialog box allows you to customize
the display colour scheme.
Backlight
The backlight is activated for a configurable amount of time. The Display Properties dialog box in the Control
Panel allows you to specify the intensity of the backlight along with h ow long the backlight r emains on when the
unit is not in use (no key press, scanner trigger, etc.).
•In the Display Properties dialog box, open the Backlight tab.
NOTEKeep in mind that this option may be restricted to supervisory use only.
Page 93
Configuration3 - 25
NOTEBacklight changes take effect immedia tely. You do not need to reset the unit.
To maximize battery run time, keep the display backlight brightness and active
durations as low as possible.
Intensity
This parameter is used to adjust the light intensity of the Omnii backlight. Sliding the bar to the left lowers the
light intensity , and sliding it to the right raises the intensity.
Bright For
The value chosen from this drop-down menu determines the duration of time that the backlight stays on at the
configured intensity after the last user action (keypress, scan trigger).
Dim For
The value chosen from this drop-down menu determines the duration of time that the backlight st ays on at ha lf
the configured intensity (dimmed backlight) after expiration of the Bright For delay and as long as no user
action takes place (such as a keypress or scan trigger). At the expiration of the Dim For duration, the display
backlight shuts off.
External Power Check Box
When you select the check box next to When using external power keep the backlight always ON, the backlight remains ON at the configured intensity when the Omnii is operating with external power (not battery
power). If the Omnii is drawing power from its battery, this option is ignored a nd the other p arameters defined in
Display Properties dialog box take effect.
Dr. Debug
Dr. Debug is an error diagnostic and troubleshooting tool.
•Tap on Start>Settings>Control Panel. Tap on the Dr. Debug icon.
Status
This tab indicates the status (on/off) of the debug engines. Tapping on Browse logs displays error logs for
your review. The logs should be used as reference when working with Motorola Technical Support personnel.
Page 94
3 - 26Omnii Hand-Held with Windows CE 6.0 User Manual
Utilities
The Utilities tab can be used to log network traffic. When you tap on the Start button, debug data is collected
so that, if necessary, it can be forwarded to a Motorola technician for evaluation.
The Utilities tab can also be used to log heater control logic board information.
Motion Meter
Tapping on the Start button enables the Motion Meter feature. Once enabled, this applet records the number of
impacts the Omnii has sust ained, the distance of the fall in meters, the duration in 10
date and time that the event occurred. The top 40 event s are logged in a non-volatile location and can be used
for diagnostic purposes by Motorola or the site administrator.
ths
of a second, and the
Page 95
Settings
Configuration3 - 27
•Choose an Error Level from the drop-down menu.
•To change the location where debug information will be stored, tap on the button to the right of the Log
Folder option.
Error Reporting
Error Reporting allows you to enable or disable Microsoft error reporting prompts.
•Tap on Start>Settings>Control Panel>Error Reporting icon to access your options.
GPS (Global Positioning System) Settings
This applet allows you to define how the GPS module operates. You can determine when the GPS module is
powered and operating, and choose from a set of GPS profiles built into the modem. You can also set up the
AGPS Manager (an assisted GPS utility).
•Tap on Start>Settings>Control Panel>GPS Settings icon.
Page 96
3 - 28Omnii Hand-Held with Windows CE 6.0 User Manual
Power
This tab allows you to dictate how the GPS module behaves. The GPS Power drop-down menu is used to
control when the GPS is powered on and off.
•Off – the GPS module is left off, always.
Profiles
• Always on – the GPS module is powered on at all times regardless of the powe r state of the han d-he l d
(suspend).
•On, and off in suspend – the GPS module is powered on, but if the Omnii is in suspend mode, the GPS
module is turned off.
Tapping on the GPS Profile Selection drop-down menu allows you to choose an appropriate profile: Default, Automotive or Pedestrian.
•Default profile is a good general profile suitable for most uses.
•Automotive profile is designed for in-vehicle use, providing quick location updates as the vehicle moves.
When the GPS module is set to this profile and the vehicle enters an area such as a tunnel where satellite
coverage is interrupted, it will attempt to predict the vehicle position.
•Pedestrian profile is designed for those using the GPS module while walking. It takes into account the
slower pace of the pedestrian when mapping the location of the user. When the GPS module is set to this
profile and the operator moves into an area where satellite coverage is interrupted, the GPS module will not attempt to predict the operator’s movement.
Page 97
Programs
Tap on the GPS Program Port drop-down menu to choose the communication (COM)
port that the GPS software will use to communicate with the GPS receiver.
AGPS
Configuration3 - 29
To determine your location, a GPS module receives data from three or more GPS satellites in fixed orbit
around the Earth. The GPS module triangulates your location based on the time it takes for signals to get to
and from the satellites. This works well in fairly clear areas, outdoors for example. However, if you’re
attempting to triangulate your location in city centres where signals bounce off tall concrete buildings or from
within a building, the GPS module will have greater difficulty calculating a fix.
AGPS reduces Time To First Fix (TTFF) and increases the likelihood of finding and keeping a fix in poor
coverage areas such as indoor sites. AGPS downloads satellite ephemeris (orbital) data to the Omnii periodically through Wi-Fi or WWAN. The downl oaded data is used by the GPS module to speed the process of
getting a fix.
Update
•Click on the Update button to download Extended Ephemeris (EE) files from a secure host on the Internet
using any interface that has an Internet connection. These files contain several days worth of ep hemeris
(orbital) data that can be used if the satellite broadcast ephemeris is not available.
The Status field above the Update button displays the progress of the download, and once successfully downloaded, the Status field will read Idle.
Settings
•Click on the Settings button to define the AGPS server connection settings.
Page 98
3 - 30Omnii Hand-Held with Windows CE 6.0 User Manual
The AGPS server connection settings drop-down menu allows you to choose from two settings: Use default
settings and Use custom settings.
The Use default settings option is generally acceptable for most applications. Note that aside from the Update
field in which you can choose how long the fix is stored in your Omnii, the field values cannot be edited.
The Use custom settings option is generally used to configure devices that will have access only to an intranet
rather than the Internet and should only be altered with the assistance of qualified Motorola personnel. They
will be able to help you configure your Motorola devices and web server to retrieve the ephemeris data.
Info
This tab provides general information about the GPS module such as the firmware version, the date on which
files were last updated, and so on. If GPS module support service is requir ed, yo u may be asked to tap on the
Save button in this tab and forward the information to Motorola support staff.
Imager & Camera Settings
The Imagers applet is used to create, modify, delete, and activate imager and camera settings. The principle
uses of the applet are to decode barcodes and to capture images. A Demonstration Application is provided to
demonstrate how the imager works. Refer to “Demo” on page 2-23 for details.
Refer to Appendix B: “Imager & Camera Settings” for configuration details.
•In the Control Panel, choose the Imagers icon.
Page 99
Configuration3 - 31
Soft Keyboard
Input Panel
Button Icon
NOTEThis icon is only displayed when the appropriate imager is installed in your
Omnii. If there is an imager installed but this icon is not present, additional software (ICS) may need to be installed.
To enable a newly-installed imager, Press and hold down the [FN] key and the
[Enter/Power] key simultaneously for a minimum of three seconds.
Input Panel
The Omnii is equipped with a Soft Input Panel (SIP). Shown below is the standard Microsoft SIP, accessed
from the Control Panel.
Tapping on the Input Panel button displays a soft input panel (soft keyboard) that can be customized using the
Input Panel dialog box.
Page 100
3 - 32Omnii Hand-Held with Windows CE 6.0 User Manual
IMPORTANTIf the Input Panel button icon is not visible in the taskbar, from the
Start menu, tap on Settings>Taskbar and Start Menu. T ap the check
box next to Show Input Panel Button. To remove this icon from the
taskbar, tap in the check box to erase the check mark.
The soft keyboard operates just like a standard keyboard except that rather than pressing a key, you tap on
letters, numbers, modifier keys, etc. on the Omnii screen.
To customize the appearance and behaviour of the soft keyboard:
Tap on the Input Panel icon in the Control Panel.
Figure 3-2
•Tap on the Optio ns button to change the appearance of your soft keyboard.
Input Panel Properties
NOTEYou can also display this dialog box by double-tapping on the Input icon in the
far-right corner of the taskbar.
Figure 3-3
Soft Keyboard Options
Keyboard Properties
This icon displays the Keyboard Properties dialog box in which you can adjust the repeat rate of the keys, the
intensity of the keyboard backlight a nd the behaviour of the [FN] a nd [SYM] modifier ke ys. This dialog box also
allows you to define macro keys and Unicode characters.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.