Moticon INSOLE1 User Manual

Instructions
OPENGO
SENSOR INSOLE
WARNING
See the detailed product information
!
and tutorial videos in the support
section of the moticon homepage
Do not use a sharp object to remove
!
user-replaceable coin cells.
Contact your local waste disposal
!
department to properly recycle the coin
cells. Perchlorate material, special
handling my apply.
1
Warnings
Warnings
WARNING
Remove the coin cells when you have
!
finished your measurements.
Store the sensor insole only without
coin cells.
The coin cell compartment must face
!
down when inserting a sensor insole
into a shoe.
!
The sensor insole does not need
maintenance and must only be cleaned
as described here
2
NOTICE ON RISKS ON HEALTH
The OpenGo sensor insole is no
!
orthotic. In case an orthotic is used,
consult your doctor if it can be replaced
by a OpenGo sensor insole.
Only wear a left and a right sensor
!
insole in order to avoid asymetric gait.
Only wear OpenGo sensor insoles with
!
socks to avoid skin irritation.
Only wear OpenGo sensor insoles in
!
the right size and in closed footwear.
3
Warnings
Warnings
NOTICE ON RISKS ON HEALTH
Immediately stop using OpenGo sensor
!
insoles if skin irritation or pain appears.
Do not wear OpenGo sensor insoles with open foot ulcers or wounds.
Do not wear OpenGo sensor insoles for
!
driving cars or climbing ladders.
Do not wear OpenGo sensor insoles if
!
strong foot sweat appears and do not
expose sensor insoles to humidity.
4
The OpenGo sensor insole is a fully integrated sensor insole. It is completely wireless
and hence does not interfere the wearer‘s
motion.
The sensor insole measures the plantar
pressure distribution, total loads and the acceleration of the foot.
5
OpenGo sensor insole overview
wireless
precise
ultra flat & robust
Specifications
Coin cell type User-replaceable PD2032 (rechargeable),
3.7 volts
Coin cell life Up to 29 hours, depending on operation
mode
Operating From 10°C to 40°C temperature range
Radio frequency/ 2.4 GHz ANT wireless protocol communications protocol
Water resistance No, cleaning with liquid sanitizer
6
Coin cell charger
Power supply
Coin cells
Coin cell Coin cell charger
Model PD2032 Type rechargeable
Voltage 3.7 V
Capacity 75 mAh Cycles 400 (70 %)
7
Model wall adapter or other
Type CC / CV
Charge voltage
4.2 V
OpenGo sensor insoles should exclusively
be operated with rechargeable coin cells !
Primary coin cells (batteries) may cause mal-
function due to a much faster voltage drop !
You need 1 coin cell model PD2032 for each
sensor insole.