R
User Guide
Industrial Actuator
CAUTIONCAUTION
KG
Load
MOTORIZE OUR WORLD
Model: ID10
The load should be centered on the operating direction.
Side load is NOT good for actuators.
KG
Side Load
MANUAL DRIVE (MD) CONNECTOR
The MD (manual drive) is an alternative way to drive the motor directly, if the power is not available.
Step 1. Remove the plug on the gearbox cover.
Step 2. Use a 8.0mm hex bit or electric screwdriver (recommended) to drive the gear directly.
Step 3. Insert the plug into the hole, and confirm the plug is installed properly.
● The Max. drive torque is 6kg-cm with 4500N load.(Ball Screw)
Gear
Plug
WIRE CONNECTION
For ID10 actuators, connection rule of power wires varies according to different types and gear ratio(s).
Please follow the instructions below.
Standard Type
● Please refer to the table below to define the actuator's extension. When Red (M+)
is connected to "+" and Black (M-) is connected to "-" of DC power, the actuator
will extend.
Gear ratio
Power
Red Black
M+5:1, 10:1, 20:1
M-30:1, 40:1
M-
M+

With Hall Sensor Type
● Please refer to the table below to define the actuator's extension.
When Red (M+) is connected to "+" and Black (M-) is connected to "-" of DC
power, the actuator will extend.
● White, Yellow & Blue are positioning signal wires as shown in table.
● The resistance between Blue and Yellow wires increases when extending,
and decreases when retracting.
● Signal resolution:20PPI, 1.27mm/pulse (0.787 pulses/mm)
With Limit Switch Type
With Potentiometer Type
Power
Red Black
M+ M-
White Yellow Blue
VCC Data GND
Signal
● Please refer to the table below to define the actuator's extension. When
Red (M+) is connected to "+" and Black (M-) is connected to "-" of DC
power, the actuator will extend.
Power
Red Black
M+ M-
● Please refer to the table below to define the actuator's extension. When
Red (M+) is connected to "+" and Black (M-) is connected to "-" of DC
power, the actuator will extend.
● White, Yellow & Blue are positioning signal wires as shown in table.
● The resistance between Blue and White wires increases when extending,
and decreases when retracting.
Power
Red Black
M+ M-
Y
B
W
Stroke (mm) Resistance (tolerance: ±0.3KΩ)
White Yellow Blue
GND VCC Data
Signal
102 0.3 ~ 8.1K
153 0.3 ~ 8.7K
203 0.3 ~ 9.2K
254 0.3 ~ 7.4K
B
YW
305 0.3 ~ 8.8K
457 0.3 ~ 9.4K
Actuator extends
610 0.3 ~ 9.8K
SAFETY DECLARATION
This appliance cannot be used by children or persons with reduced physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they have been given supervision or instruction.
© 2018 Moteck. Printed in Taiwan. The contents of this publication are the copyright of the publisher and may not be copied or even extracted unless prior written
permission is authorized.
M1-FAM-I-0001-1.3