Motec C125, L180, L120, C127, C187 User Manual

...
2016 Pirelli World Challenge
Series Spec Logger (SSL)
Handbook
Document: PWC_SSL_Handbook Revision:
Date: Prepared by:
Christopher Brown CB-Racing
Page
2
of 12
PWC SSL Handbook
1. INTRODUCTION
This document outlines the implementation of the new Series Spec Logger as it pertains to the 2016 Pirelli World Challenge Series. All GT classes will require a MoTeC logger. This logger must be setup via the guidelines set forth by PWC as outlined in this document. The Series Spec Logger will be open for teams to use and configure themselves. Display settings, additional channels and sensors and logging are all open for the teams to use as they see fit. Most other series around the world have very controlled loggers, adding cost with no added value to the teams. We hope this program continues to be open and encourage teams to use the data for driver coaching, system and engine checks and doing their own compliance checking. This handbook will change and be updated as needed throughout the year.
Please refer to the Pirelli World Challenge Technical Regulations for a complete list of rules.
2. WHERE TO PURCHASE
Teams are allowed to purchase their MoTeC logger from any North American MoTeC dealer. It is highly recommended to purchase from a dealer whom you wish to be supported by. Your MoTeC dealer will be your first contact for all support needs. Installation, setup and training are all things you should consider in detail when deciding who to purchase from.
All MoTeC loggers will require a setup check before competing in the PWC series. This will help ensure proper configuration and compliance within the guidelines set forth by PWC and listed in this document. That check will be done by Christopher Brown of CB-Racing. He will be the main MoTeC support dealer for the PWC series. If you have any questions regarding the PWC SSL please contact him through email at: cb@cb-racing.com
3. ALLOWED MOTEC LOGGER MODELS
Any L1xx or C1xx will be eligible for 2016 and beyond. Model numbers include: L120, L180, C125, C185, C127 or C187. The last digit is the display screen size in inches. The CDL3, SDL3, ADL3 & ACL are also eligible for 2016, and may or may not be eligible after 2016 due to software or hardware limitations of future additions to the PWC SSL requirements. The older MoTeC loggers such as the ADL, SDL and ADL2 are not eligible.
Essentially the newest range of MoTeC loggers will have all of the features required for PWC in the foreseeable future. The older MoTeC dashes can not be upgraded with regards to certain functionality. Hence some are eligibility for 2016 but not guaranteed beyond 2016.
Page
3
of 12
PWC SSL Handbook
4. Prices
Prices outlined below are current retail pricing as of December 2015. These prices are subject to change without notice. These are the base starting prices with logging. Additional items of cost will include logger options, wiring harness, required GPS and sensors. These are explained further down.
Model Display Starting Price Memory Analog Sensor Inputs*
with logging starts at base / with I/O option
L120 non display $ 2195 120MB 0 / 8 C125 5" color $ 2710 120MB 0 / 8 C127 7" color $ 3210 120MB 0 / 8 L180 non display $ 4040 250MB 10 / 28 C185 5" color $ 5390 250MB 10 / 28 C187 7" color $ 5990 250MB 10 / 28
Front L120 / L180 Back of L120 Back of L180
*required for boost cars
Front C125 / C185 Back of C125 Back of C185
Front of C127 / C187
Page
4
of 12
Option List for Loggers:
These options may be enabled at any time, and never expire on the logger purchased for.
I/O Options: Activates additional sensor input pins on the back of the dash. On the 12x series
loggers this option is required for measuring boost pressure, but may not be required for normally aspirated cars where all the required data is being streamed through the CAN bus. On the 18x series loggers a number of inputs are already included. See table above for Analog Sensor Inputs.
Pro Logging: All data files created on MoTeC loggers can be opened in i2 Standard analysis
software. This software is free to download from the MoTeC web site. The Pro Logging option enables data files created by the logger to be opened using i2 Pro analysis software. The Pro software is also free to download and adds advanced functions like shock histograms, advanced math equations, unlimited graphs and worksheets, setup sheets, etc. i2 Pro only opens pro files, i2 Standard will open both Pro and Standard data files.
Memory / USB: This option doubles the onboard logging memory
and on newer dashes it also enables the external USB logging. Beginning in 2016, all MoTeC L1xx and C1xx loggers will have the ability to utilize a USB memory stick. Older models won't have USB but will have the additional memory increased when buying this option.
L120 C125,C127 17 I/O $ 400 $ 400 enables sensor inputs and outputs Pro Logging $ 800 $ 800 enables pro analysis software 250MB / USB $ 525 $ 530 enables additional 120MB logging memory & USB stick T2 telemetry $ 2250 $ 2250 activates the T2 telemetry data stream *radios extra L180 C185,C187 44 I/O $ 1120 $ 1300 enables sensor inputs and output Pro Logging $ 1120 $ 1300 enables pro analysis software 500MB / USB $ 890 $ 1040 enables additional 250MB logging memory & USB stick Adv Functions $ 890 $ 1040 enables advanced math, timers, tables T2 telemetry $ 2510 $ 2925 activates the T2 telemetry data stream *radios extra
PWC SSL Handbook
Optional SLM - SHIFT LIGHT MODULE
The MoTeC SLM features bright multi-color LEDs which are ideally suited for a multitude of functions such as shift lights, warning lights, yellow flag lights or brake lockup lights. This is the perfect way to increase the functionality of your MoTeC logger to help the driver. It is easily adapted to any MoTeC logger with or without a display. For many installations the steering wheel blocks the built in light array. An external light module is easily mounted further up on top of the dashboard where it can be in the peripheral view of the driver. Cost is $585.
Loading...
+ 8 hidden pages