4
V62C318256 Rev. 1.7 July 2001
MOSEL VITELIC
V62C318256
DC Electrical Characteristics
(over all temperature ranges, V
CC
= 2.7V – 3.6V)
NOTES:
1. These are absolute values with respect to device ground and all overshoots due to system or tester noise are included.
2. V
IL
(Min.) = -3.0V for pulse width < 20ns.
3. f
MAX
= 1/t
RC
.
4. Maximum values.
Symbol Parameter Test Conditions Min. Typ. Max. Units
V
CC
Power Supply Voltage 2.7 — 3.6 V
V
IL
Input LOW Voltage
(1,2)
-0.3 — 0.4 V
V
IH
Input HIGH Voltage
(1)
2.2 — V
CC
+0.3 V
I
IL
Input Leakage Current V
CC
= Max, V
IN
= 0V to V
CC
-2 — 2
µ
A
I
OL
Output Leakage Current V
CC
= Max, CE
= V
IH
, V
OUT
= 0V to
V
CC
-2 — 2
µ
A
V
OL
Output LOW Voltage V
CC
= Min, I
OL
= 2.1mA ——0.4 V
V
OH
Output HIGH Voltage V
CC
= Min, I
OH
= -1mA 2.4 —— V
Symbol Parameter Com.
(4)
Ind. Units
I
CC
(read) Operating Power Supply Current, CE
= V
IL
, WE
= V
IH
Output Open, V
CC
= Max., f = 0
22mA
I
CC
(write) Operating Power Supply Current, CE
= V
IL
, WE
= V
IL
Output Open, V
CC
= Max., f = 0
20 20 mA
I
CC1
Average Operating Current, CE
≤ V
IL
Output Open,
V
CC
= Max., f = f
MAX
(3)
40 40 mA
I
SB
TTL Standby Current
CE
≥ V
IH
, V
CC
= Max.
L23mA
LL 1 1
I
SB1
CMOS Standby Current, CE
≥ V
CC
– 0.2V,
V
IN
≥
V
CC
– 0.2V or V
IN
≤
0.2V, V
CC
= Max.
L5060 µ A
LL 15 20
AC Test Conditions
AC Test Loads and Waveforms
Key to Switching Waveforms
Input Pulse Levels 0 to 3V
Input Rise and Fall Times 5 ns
Timing Reference Levels 1.5V
Output Load see below
+3V
1103 Ω
1554 Ω
* Includes scope and jig capacitance
I/O Pins
C
L
= 30 pF*
318256 07
WAVEFORM INPUTS OUTPUTS
MUST BE
STEADY
WILL BE
STEADY
MAY CHANGE
FROM H TO L
WILL BE
CHANGING
FROM H TO L
MAY CHANGE
FROM L TO H
WILL BE
CHANGING
FROM L TO H
DON'T CARE:
ANY CHANGE
PERMITTED
CHANGING:
S TATE
UNKNOWN
DOES NOT
APPLY
CENTER
LINE IS HIGH
IMPEDANCE
“OFF” STAT E