V54C3256164VBUC/T LOW POWER 256Mbit SDRAM
3.3 VOLT, 54-BALL SOC BGA 54-PIN TSOPII 16M X 16
V54C3256164VBUC/T Rev. 1.1 February 2003
PRELIMINARY
System Frequency (f
CK
) 166 MHz 143 MHz 143 MHz 125 MHz
Clock Cycle Time (t
CK3
) 6 ns 7 ns 7 ns 8 ns
Clock Access Time (t
AC3
) CAS Latency = 3 5.4 ns 5.4 ns 5.4 ns 6 ns
Clock Access Time (t
AC2
) CAS Latency = 2 5.4 ns 5.4 ns 6 ns 6 ns
Features
4 banks x 4Mbit x 16 organization
High speed data transfer rates up to 166 MHz
Full Synchronous Dynamic RAM, with all signals
referenced to clock rising edge
Single Pulsed RAS
Interface
Data Mask for Read/Write Control
Four Banks controlled by BA0 & BA1
Programmable CAS
Latency: 2, 3
Programmable Wrap Sequence: Sequential or Interleave
Programmable Burst Length: 1, 2, 4, 8 for Sequential Type 1, 2, 4, 8 for Interleave Type
Multiple Burst Read with Single Write Operation
Automatic and Controlled Precharge Command
Random Column Address every CLK (1-N Rule)
Power Down Mode
Auto Refresh and Self Refresh
Refresh Interval: 8192 cycles/64 ms
Available in 54-Ball SOC BGA/ 54-Pin TSOP II
LVTTL Interf a ce
Single +3.3 V ±0.3 V Power Supply
Low Power Self Refresh Current
L-version 1.0mA
U-version 0.6mA
Description
The V54C3256164VBUC/T is a low power four bank Synchronous DRAM organized as 4 banks x 4Mbit x 16. The V54C3256164VBUC/T achieves high speed data transfer rates up to 16 6 MHz by employing a chip architecture that prefetches multi­ple bits and then synchronizes the output data to a system clock
All of the control , address, data input and output circuits are synchronized with the positive edge of an externally supplied clock.
Operating the four memory banks in an inter­leaved fashion allows random access operation to occur at higher rate t han is possible with standard DRAMs. A sequential and gapless data rate of up to 166 MHz is possible depending on burst length, CAS
latency and speed grade of the device.
The V54C3256164VBU C/T is ideally suited for high performance, low power systems such as PDA, mobile phone, DSC, and other battery backup applications.
Device U sage Chart
Operating
Temperature
Range
Package Out-
line Access Time (ns) Power
Temperature
MarkC/T 6 7PC 7 8PC Std. L U T
0°C to 70°C ••••••••Blank
2
V54C3256164VBUC/T Rev. 1.1 February 2003
MOSEL VITELIC
V54C3256164VBUC/T
V 54 C 3 25616 4 V B U X
Mosel Vitelic Manufactured
Synchronous DRAM Family
C=CMOS Family
3.3V, LVTTL Interface 256Mb(8K Refresh)
4 Banks
V=LVTTL
Component Rev Level
Special Feature
L=Low Power
C= 54Ball SOC BGA T= 54Pin TSOP Package
Device Number
Speed 6 ns 7 ns 8 ns
B=0.14um
U=Ultra Low Power
Description Pkg. Pin Count
SOC BGA C 54
A B C D E F G H J
:
Ball Existing
: Depopulated Ball
Top View
(See the balls through the package)
54B SOC BGA
1 2 3 7 8 9
A B C D E F G H J
x16
VSS DQ14 DQ12 DQ10 DQ8 UDQM
DQ15 DQ13 DQ11
DQ9 NC CLK A11 A7
A5
VSSQ VCCQ VSSQ VCCQ
VSS CKE A9 A6
A4
A12 A8 VSS
VCCQ VSSQ VCCQ VSSQ VCC CAS
DQ0
DQ2 DQ4 DQ6
LDQM
RAS BA1 A1
A2
VCC DQ1 DQ3 DQ5 DQ7
WE BA0 A0 A3
CS
A10
VCC
8
2
7
1
354
6
9
3
V54C3256164VBUC/T Rev. 1.1 February 2003
MOSEL VITELIC
V54C3256164VBUC/T
54 Pin Plastic TSOP -I I PIN CONFIGURATION
Top View
Pin Names
V
CC
I/O
1
V
CCQ
I/O
2
I/O
3
V
SSQ
I/O
4
I/O
5
V
CCQ
I/O
6
I/O
7
V
SSQ
I/O
8
V
CC
L
DQM
WE CAS RAS
CS BA0 BA1
A
10
A
0
A
1
A
2
A
3
V
CC
V
SS
I/O
16
V
SSQ
I/O
15
I/O
14
V
CCQ
I/O
13
I/O
12
V
SSQ
I/O
11
I/O
10
V
CCQ
I/O
9
V
SS
NC UDQ
M
CLK CKE A
12
A11 A
9
A
8
A
7
A
6
A
5
A
4
V
SS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28
356164V-01
CLK Clock Input CKE Clock Enable CS
Chip Select
RAS
Row Address Strobe
CAS
Column Address Strobe
WE
Write Enable
A
0–A12
Address Inputs BA0, BA1 Bank Select I/O
1
–I/O
16
Data Input/Output LDQM, UDQ M Data Mask V
CC
Power (+3.3V) V
SS
Ground V
CCQ
Power for I/O’s (+3.3V) V
SSQ
Ground for I/O’s NC Not connected
Description Pkg. Pin Count
TSOP-II T 54
MOSEL VITELIC
V54C3256164VBUC/T
4
V54C3256164VBUC/T Rev1.1 February 2003
Capacitance*
TA = 0 to 70°C, VCC = 3.3 V ± 0.3 V, f = 1 Mhz
*Note:Capacitance is sampled and not 100% tested.
Absolute Maximum Ratings*
Operatin g tempe r a tu re r a n ge..................0 to 70 °C
Storage temperature range................-55 to 150 °C
Input/ou tp u t vo lt a g e....... ...........-0.3 to (V
CC
+0.3) V
Power supply volt a g e.................. ........-0.3 to 4.6 V
Power dissipation..............................................1 W
Data out current (short circuit).......................50 mA
*Note: Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage of the device. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
Symbol Parameter
Max. Unit
C
I1
Input Ca pacitance (A0 to A12) 5 pF
C
I2
Input Capacitance RAS
, CAS, WE, CS, CLK, CKE, DQM
5pF
C
IO
Output Capacitance (I/O) 6.5 pF
C
CLK
Input Capacitance (CLK) 4 pF
Block Diagram
Row decoder
Memory array
Bank 0
8192 x 512
x 16 bit
Column decoder
Sense amplifier & I(O) bus
Row decoder
Memory ar ray
Bank 1
8192 x 512
x16 bit
Column decoder
Sense amplifier & I(O) bus
Row decoder
Memory array
Bank 2
8192 x 51 2
x 16 bit
Column decoder
Sense amplifier & I(O) bus
Row decoder
Memory array
Bank 3
8192 x 512
x 16 bit
Column decoder
Sense amplifier & I(O) bus
Input buffer Output buffer
I/O1-I/O
16
Column address
counter
Column address
buffer
Row address
buffer
Refresh Counter
A0 - A12, BA0, BA1A0 - A8, AP, BA0, BA1
Control logic & timing generato r
CLK
CKE
CS
RAS
CAS
WE
LDQM
Row Addresses
Column Addresses
UDQM
x16 Configuration
5
V54C3256164VBUC/T Rev. 1.1 February 2003
MOSEL VITELIC
V54C3256164VBUC/T
Signal Pi n D escrip t i o n
Pin Type Signal Polarity Function
CLK Input Pulse Positive
Edge
The system clock input. All of the SDRAM inputs are sampled on the rising edge of the clock.
CKE Input Level Active High Activates th e CLK signal when hi gh and deactivate s the CLK signal when low, thereby
initiates either the Power Down mode or the Self Refresh mode.
CS
Input Pulse Active Low CS enables t he comm and decoder when low and disables th e comman d decod er when
high. Wh en the co mma nd de co der i s d is ab led, ne w com man ds ar e ign or e d but pr ev ious operations continue.
RAS
, CAS WEInput Pulse Active Low When sampled at the positive rising ed ge of the cl ock, CAS, RAS, and WE define the
command to be executed by the SDRAM.
A0 - A11 Input Level During a Bank Acti vate command cycle, A0-A12 defines the row add ress (RA0-RA12)
when sampled at the rising clock edge. During a Read or Write command cycle, A0-An def ines the column address (C A0-CAn) when sampled at the rising clock edge.CAn depends from the SDRAM organization:
• 16M x 16 SDRAM CA0–CA8.
In addition to the column address, A10(=AP) is used to invoke autoprechar ge operation at the end of the burst read or write cycle. If A10 is h igh, autoprecha rge is selected and BA0, BA1 defines the bank to be precharged. If A10 is low, autoprecharge is di sabled. During a Pr ec har ge comman d c ycl e , A1 0( =AP ) i s us ed in conj un ct io n wi th B A0 a nd BA1 to control which bank(s) to precharge. If A10 is high, all four banks will BA0 and BA1 are used to define which bank to precharge.
BA0,
BA1
Input Level Selects which bank is to be active.
DQx Input
Output
Level Data Input/Output pi ns operate in the same manner as on convention al DRAMs.
LDQM UDQM
Input Pulse Active High The Data Input/Output mask places the DQ buffers in a high impedance state when sam-
pled high . In Re ad mode, DQ M has a lat en cy of t wo cl oc k cyc le s an d co ntr ols the out put buffer s li ke an ou tput e na ble. I n Wr i te mo de , DQ M ha s a lat en cy of zer o and o pe rat es as a word mask by allowing input data to be written if it is low but blocks the write operation if DQM is high.
VCC, VSS Supply Power an d ground for the inp ut bu ff e rs and the core logic .
VCCQ VSSQ
Supply Isolated power supply and ground for the output buffers to provide improved noise
immunity.
6
V54C3256164VBUC/T Rev. 1.1 February 2003
MOSEL VITELIC
V54C3256164VBUC/T
Operation Definition
All of SDRAM operations are defined by states of c ontrol signals CS, RAS, CAS, WE, and DQM at the
positive edge of the clock. The following list shows the thruth table for the operation commands.
Notes:
1. V = Valid , x = Don’t Care, L = Low Level, H = H igh Lev el
2. CKEn signal is input level when commands are provided, CKEn-1 si gnal is input level one clo c k before the commands are provided.
3. These are state of bank designated by BS0, BS1 signals.
4. Power Down Mode can n ot entry in the burs t cycle.
Operation
Device
State
CKE
n-1
CKE
nCSRAS CAS WE DQM
A0-9,
A11,
A12 A10
BS0 BS1
Row Activate Idle3 HXLLHHXVVV Read Active
3
HXLHLHXVLV
Read w/Autoprecharge Active
3
HXLHLHXVHV
Write Active
3
HXLHLLXVLV
Write with Autoprecharge Active
3
HXLHLLXVHV Row Precharge Any H X L L H L X X L V Precharge All Any H X L L H L X X H X Mode Register Set Idle H X L L L L X V V V No Operation Any H X L H H H X X X X Device Dese lect Any H X H X X X X X X X Auto Refresh Idle H H L L L H X X X X Self Refresh Entry Idle H L L L L H X X X X Self Refresh Exit Idle
(Sel f Refr.) L H
HXXX
XXXX
LHHX
Power Down Entry Idle
Active
4
HL
HXXX
XXXX
LHHX
Power Down Exit Any
(Power
Down)
LH
HXXX
XXXX
LHHL
Data Write/Output Enable Active H X X X X X L X X X Data Write/Output Disable Active H X X X X X H X X X
7
V54C3256164VBUC/T Rev. 1.1 February 2003
MOSEL VITELIC
V54C3256164VBUC/T
Power On and Initialization
The default power on state of the mode register is supplier specific and may be undefined. The following power on and initialization sequence guarantees the device is preconditioned to each users specific needs. Like a conventional DRAM, the Synchronous DRAM mu st be powered up and initialized in a predefined manner. During power on, all VCC and VCCQ pins must be built up simultaneously to the specified voltage when the input signals are held in the “NOP” state. The power on voltage must not exceed VCC+0.3V on any of the input pins or VCC supplies. The CLK signal must be started at the same time. After power on, an initial pause of 200 µs is requi red followed by a precharge of both banks using the precharge command. To preven t data contention on the DQ bus during power on, it is required that the DQM and CKE pins be held high during the initial pause period. Once all banks have bee n precharged, the Mode Register Set Command must be issued to initialize the Mode Register. A minimum of eight Auto Refresh cycles (CBR) are also required.These may be done before or after programming the Mode Register. Failure to follow these steps may lead to unpredictable start-up modes.
Programming the Mode Register
The Mode register designates the operation mode at the read or write cycle. This register is di­vided into 4 fields. A Burst Length Field to set the length of the b urst, an Addressing S election bit to program the column access sequence in a burst cy­cle (interleaved or sequential), a CAS Latency Field to set the access time at clock cycle and a Opera­tion mode field to differentiate between normal op­eration (Burst read an d burst Write) and a spec ial Burst Read and Sing le Write mode. The mode set
operation must be done before any activate com­mand after the initial power up. Any content of the mode register can be altered by re-executing the mode set command. All banks must be in pre­charged state and CKE must be high at least one clock before the mode set operation. After the mode register is set, a Standby or N OP command is re­quired. Low signals of RAS
, CAS , and WE at the positive edge of the clock activate the mode set op­eration. Address input data at this timing defines pa­rameters to be set as shown in the previous table.
Read and Write Operation
When RAS is low and both CAS and WE are hig h at the positive edge of the clock, a RAS cycle starts. According to address data, a word line of the select­ed bank is activated and all of sense amplifiers as­sociated to the wordline are set. A CAS
cycle is
triggered by setting RAS
high and CAS low at a
clock timing after a necessary delay, t
RCD
, from th e
RAS
timing. WE is used to define either a read
(WE
= H) or a write (WE = L) at this stage.
SDRAM provides a wide variety of fast access modes. In a single CAS cycle, serial data read or write operations are allowed at up to a 125 MHz data rate. The numbers of serial data b its are the burst length programmed at the mode set operation, i.e., one of 1, 2, 4, 8 . Column addresses are seg­mented by the burst length and serial data accesses are done within this boundary. T he first colum n ad­dress to be accessed is supplied at the CAS timing and the subsequent addresses are generated auto­matically by the programmed burst length and its sequence. For example, in a burst length of 8 with interleave sequence, if the first address is ‘2’, then the rest of the burst sequence is 3, 0, 1, 6, 7, 4, and
5.
MOSEL VITELIC
V54C3256164VBUC/T
8
V54C3256164VBUC/T Rev1.1 February 2003
Address Input for Mode Set (Mode Register Operation)
Similar to the page mode of conventional DRAM’s, burst read or write accesses on any col­umn address are possible once the RAS cycle latches the sense amplifiers. The maximum t
RAS
or the refresh interval time limits the number of random column accesses. A new burst access can be done even before the previous burst ends. The interrupt operation at every clock cycles is supported. When the previous burst is interrupted, the remaining ad­dresses are overridden by the new address with the full burst length. An interrupt which accompanies
with an operation change from a read to a write is possible by exploiting DQM to avoid bus contention.
When two or more banks are activated sequentially, interleaved bank read or write operations are possible. With the programmed burst length, alternate access and precharge operations on two or more banks can real ize fast serial data access modes among many different pages. Once two or more banks are activated, column to column interleave operation can be done between different pages.
A11
A3A4 A2 A1 A0
A10 A9
A8 A7 A6 A5
Address Bus (Ax)
BT Burst LengthCAS Latency
Mode Register
CAS Latency
A6 A5 A4 Latency
0 0 0 Reserve 0 0 1 Reserve 010 2 011 3 1 0 0 Reserve 1 0 1 Reserve 1 1 0 Reserve 1 1 1 Reserve
Burst Length
A2 A1 A0
Length
Sequential Interleave 000 1 1 001 2 2 010 4 4 011 8 8 1 0 0 Reserve Reserve 1 0 1 Reserve Reserve 1 1 0 Reserve Reserve 1 1 1 Reserve Reserve
Burst Type
A3 Type
0 Sequential 1 Interleave
Operation Mode
BA1 BA0 A11 A10 A9 A8 A7 Mode
0000000
Burst Read/Burst
Write
0000100
Burst Read/Single
Write
Operation Mode
BA0BA1
9
V54C3256164VBUC/T Rev. 1.1 February 2003
MOSEL VITELIC
V54C3256164VBUC/T
Burst Length and Sequence:
Refresh Mode
SDRAM has two refresh modes, Auto Refresh
and Self Refresh. Auto Refresh is similar to the CAS
-before-RAS refresh of conventional DRAMs. All of banks must be precharged before ap plying any re­fresh mode. An on-chip address counter increments the word and the bank addresses and no bank infor­mation is required for both refresh modes.
The chip enters the Auto Refresh mode, when
RAS
and CAS are held low and CKE and WE are held high at a clock timing. The mode restores word line after the refresh and no external precharge command is necessary. A m inimum tRC t ime is re­quired between two automatic refreshes in a burst refresh mode. The same rule applies to any access command after the automatic refresh operation.
The chip has an on-chip timer and the Self Re­fresh mode is available. It enters the mode when RAS
, CAS, and CKE are low and WE is high at a clock timing. All of external control signals including the clock are disabled. Returning CKE to hi gh en­ables the clock and initiates the refr esh exit opera­tion. After the exit command, at least one t
RC
delay
is required prior to any access command.
DQM Function
DQM has two functions for data I/O read and write operations. During reads, when it turns to “high” at a clo ck timing, data outputs are disabled and become high impedanc e after two clock delay (DQM Data Disable Latency t
DQZ
). It also provides
a data mask function for writes. When DQM is acti­vated, the write operation at the next clock is prohib­ited (DQM Write Mask Latency t
DQW
= zero clocks).
Power Do wn
In order to reduce standby power consumption, a power down mode is available. All banks m ust be precharged and the necessary Precharge delay (trp) must occur bef ore the SDRAM can en ter the Power Down mode. Once the Power Down mode is initiated by holding CKE low, all of the receiver cir­cuits except CLK and CKE are gated off. The Power Down mode does not perform any refresh opera­tions, therefore the device can’t remain in Power Down mode longer than the Refresh period (tref) of the device. Exit from this mode is performed by tak­ing CKE “high”. One clock delay is required for mode entry and exit.
Auto Pr ech arge
Two methods are available to precharge SDRAMs. In an automatic precharge mode, the CAS timing accepts one extra address, CA10, to determine whether the chip restores or not after the operation. If CA10 is high whe n a Read Com mand is issued, the Read with Auto-Pre charge function is initiated. The SDRAM automatically enters the precharge operation one clock bef ore the last data out for CAS
latencies 2, two clocks for CAS laten­cies 3 and three clocks for CAS latencies 4. If CA10 is high when a Write Command is issued, the Write
Burst
Length
Starting Address
(A2 A1 A0)
Sequential Burst Addressing (decimal)
Interleave Bur st Addressing (decimal)
2 xx0
xx1
0, 1 1, 0
0, 1 1, 0
4x00
x01 x10 x11
0, 1, 2, 3 1, 2, 3, 0 2, 3, 0, 1 3, 0, 1, 2
0, 1, 2, 3 1, 0, 3, 2 2, 3, 0, 1 3, 2, 1, 0
8 000
001 010 011 100 101 110 111
0 1 2 3 4 5 6 7 1 2 3 4 5 6 7 0 2 3 4 5 6 7 0 1 3 4 5 6 7 0 1 2 4 5 6 7 0 1 2 3 5 6 7 0 1 2 3 4 6 7 0 1 2 3 4 5 7 0 1 2 3 4 5 6
0 1 2 3 4 5 6 7 1 0 3 2 5 4 7 6 2 3 0 1 6 7 4 5 3 2 1 0 7 6 5 4 4 5 6 7 0 1 2 3 5 4 7 6 1 0 3 2 6 7 4 5 2 3 0 1 7 6 5 4 3 2 1 0
MOSEL VITELIC
V54C3256164VBUC/T
10
V54C3256164VBUC/T Rev1.1 February 2003
with Auto-Precharge function is initiated. The SDRAM automatically enters the precharge o pera­tion a time delay equal to t
WR
(Write recovery time)
after the last data in.
Precha r g e C o mmand
There is also a separate precharge command
available. When RAS
and WE are low and CAS is high at a clock timing, it triggers the precharge operation. Three address bits, BA0, BA1 and A10 are used to define banks as shown in the following list. The precharge comma nd can be i mposed o ne clock before the last data ou t for CAS latency = 2, two clocks before the last data out for CAS latency = 3. Writes require a time delay t wr from the last data out to apply the precharge command.
Bank Selection by Address Bits:
Burst Termination
Once a burst read or write operation has been ini­tiated, there are several methods in whi ch t o termi­nate the burst operation prematurely. These methods include using another Read or Write Com­mand to interrupt an existing burst operation, use a Precharge Command to interrupt a burst cycle and close the active bank, or using the Burst Stop Com­mand to terminate the existing burst operation b ut leave the bank open fo r future Re ad or Write Com­mands to the same page of the act ive bank. When interrupting a burst with another Read or Write Command care must be taken to avoid I/O conten­tion. The Burst Stop Command, however, has the fewest restrictions making it th e easiest method to use when terminating a burst operation before it has been completed. If a Burst Stop command is issued during a burst write operation, then any residual data from the burst write cycle will be ignored. Data that is presented on the I /O pins before the Burst Stop Command is registered will be written to the memory.
A10 BA0 BA1
0 0 0 Bank 0 0 0 1 Bank 1 0 1 0 Bank 2 0 1 1 Bank 3 1XX all Banks
Recommended Operation and Characteristics for LV-TTL
TA = 0 to 70 °C; VSS = 0 V; VCC,V
CCQ
= 3.3 V ± 0.3 V
Note:
1. All voltages are referenced to V
SS
.
2. V
IH
may overshoot to VCC + 2.0 V for pulse width of < 4ns wit h 3.3V. VIL may unde rshoot to -2.0 V for pulse width < 4.0 ns with
3.3V. Pu lse width measur ed at 50% points with amplitude m easured peak to DC reference.
Parameter Symbol
Limit Values
Unit Notesmin. max.
Input hi gh voltage V
IH
2.0 Vcc+0. 3 V 1, 2
Input lo w volt ag e V
IL
– 0.3 0.8 V 1, 2
Output high voltage (I
OUT
= – 4.0 mA) V
OH
2.4 V
Output low voltage (I
OUT
= 4.0 mA) V
OL
–0.4V
Input le ak age curren t, any input (0 V < V
IN
< 3.6 V, all other inputs = 0 V)
I
I(L)
– 5 5 µA
Output leakage current (DQ is disabled, 0 V < V
OUT
< VCC)
I
O(L)
– 5 5 µA
11
V54C3256164VBUC/T Rev. 1.1 February 2003
MOSEL VITELIC
V54C3256164VBUC/T
Opera ti n g Cu r r en ts (T
A
= 0 to 70°C, VCC = 3.3V ± 0.3V)
(Recommended Operating Conditions unle ss otherwise noted)
Notes:
7. These parameters depend on the cycle rate and these values are measured by the cycle rate und er the mi nimum value of t
CK
and
t
RC
. Input signals are changed one time during tCK.
8. These pa rameter depend on output loading. Specified values are obtained with output open.
Symbol Parameter & Test C on dition
Max.
Unit Note-6 -7 / -7PC -8PC
ICC1 Operating Current
t
RC
= t
RCMIN.
, t
RC
= t
CKMIN
. Active- precharge command cycling, without Burst Operation
1 bank operation 90 80 80 mA 7
ICC2P Precharge Standby Current
in Power Down Mode CS
=VIH, CKE≤ V
IL(max)
tCK = min. 2 2 2 mA 7
ICC2PS t
CK
= Infinity 1 1 1 m A 7
ICC2N Precharge Standby Current
in Non-Power Down Mode CS
=VIH, CKE≥ V
IL(max)
tCK = min. 55 45 35 mA
ICC2NS t
CK
= Infinity 5 5 5 m A
ICC3N No Operating Cur rent
t
CK
= min, CS = V
IH(min)
bank ; ac tive state ( 4 banks)
CKE V
IH(MIN.)
65 55 45 mA
ICC3P CKE V
IL(MAX.)
(Power down mode)
10 10 10 mA
ICC4 Burst Operating Current
t
CK
= min
Read/Write command cycling
170 150 120 mA 7,8
ICC5 Auto Refresh Current
t
CK
= min
Auto Refresh command cycling
270 240 220 mA 7
ICC6 Self Refresh Current
Self Refresh Mode, CKE 0.2V
333mA
L-version (B component rev)
1.0 1.0 1.0 mA
U-version (B component rev)
0.6 0.6 0.6 mA
12
V54C3256164VBUC/T Rev. 1.1 February 2003
MOSEL VITELIC
V54C3256164VBUC/T
AC Characteristics
1,2, 3
T
A
= 0 to 70 °C; VSS = 0 V; VDD = 3.3 V ± 0.3 V, tT = 1 ns
# Symbol Parameter
Limit Values
Unit Note
-6 -7PC -7
-8PC
Min. Max. Min. Max. Min. Max. Min. Max.
Clock and Clock Enable
1tCKClock Cycle Time
CAS
Latency = 3
CAS
Latency = 2
6
7.5––77.5––710––810––
s ns ns
2t
CK
Clock Frequency CAS
Latency = 3
CAS
Latency = 2
––166
133––
143 133––
143 100––
125 100
MHz MHz
3t
AC
Access Time from Clock CAS
Latency = 3
CAS
Latency = 2
–_5.4
5.4–_
5.4
5.4–_
5.46– _
6 6
ns ns
2, 4
4t
CH
Clock High Pulse Width 2.5–2.5–2.5–3–ns
5t
CL
Clock Low Pulse Width 2.5–2.5–2.5–3–ns
6t
T
Transitio n Tim 0.3 1.2 0.3 1 .2 0 .3 1. 2 0.5 1 0 ns
Setup and Hold Times
7tISInput Setup Time 1.5–1.5–1.5–2–ns5 8t
IH
Input Hold Time 0.8–0.8–0.8–1–ns5
9t
CKS
Input Setup Time 1.5–1.5–1.5–2–ns5
10 t
CKH
CKE Hold Time 0.8–0.8–0.8–1–ns5
11 t
RSC
Mode Register Set -up Time 12 14 14 16 ns
12 t
SB
Power Down Mode Entry Time 06070708ns
Common Parameters
13 t
RCD
Row to Column Delay Time 12 15 15 20 ns 6
14 t
RP
Row Precharge T ime 15 15 15 20 ns 6
15 t
RAS
Row Active Time 40 100K 42 100K 42 100K 45 100k ns 6
16 t
RC
Row Cycle Time 60 60 60 60 ns 6
17 t
RRD
Activate(a) to Activate(b) Command Period 12 14 14 16 ns 6
18 t
CCD
CAS(a) to CAS(b) Command Period 1 1 1 1 CLK
Refresh Cycle
19 t
REF
Refres h Period (8192 cycles) 64 64 64 64 ms
20 t
SREX
Self Ref res h E x it Tim e 1 1 1 1 CL K
13
V54C3256164VBUC/T Rev. 1.1 February 2003
MOSEL VITELIC
V54C3256164VBUC/T
Notes for AC Parameters:
1. For proper power-up see the operation section of this data sheet.
2. AC timing tests have V
IL
= 0.8V and VIH = 2.0V with the timi ng refere nced to the 1.4 V cr ossover poi nt. The tr ansition
time is measure d between V
IH
and VIL. All AC measur ements assume t
T
= 1ns with the AC ou tput load ci rcuit sho wn
in Figure 1.
4. If clock rising time is longer than 1 ns, a time (t
T
/2 – 0.5) ns has to be added to this param eter .
5. If t
T
is longer than 1 ns, a time (t
T
– 1) ns has to be added to this parameter .
6. These parameter account for the number of clock cycle and depend on the operating freque ncy of the clock, as follows:
the number of clock cyc le = specified value of timing period (counte d in fr actions as a whole number)
Self Refresh Exit is a synchronous operation and begins on the 2nd positive clock edge after CKE returns high. Self Refresh Exit is not complete until a time period equal to tRC is satisfied once the Self Refresh Exit command is registered.
7. Referenced to the time which the output achieves the open circuit condition, not to output vol tage levels
Read Cycle
21 t
OH
Data Out Hold Time 3–3–3–3–ns2
22 t
LZ
Data Out to Low Impedance Time 1–1–1–0–ns
23 t
HZ
Data Out to High Impedance Time 36373738ns7
24 t
DQZ
DQM Data Out Disable Latency 2 2 2 2 CLK
Write Cycle
25 t
WR
Write Recovery Time 2–2–2– 2 –CLK
26 t
DQW
DQM Write Mask Latency 0 0 0 0 CLK
# Symbol Parameter
Limit Values
Unit Note
-6 -7PC -7
-8PC
Min. Max. Min. Max. Min. Max. Min. Max.
1.4V
1.4V
tCS tCH
tAC
tAC
tLZ
tOH
tHZ
CLK
COMMAND
OUTPUT
50 pF
I/O
Z=50 Ohm
+ 1.4 V
50 Ohm
VIH
VIL
t
T
Figure 1.
tCK
AC Characteristics (Cont ’d)
14
V54C3256164VBUC/T Rev. 1.1 February 2003
MOSEL VITELIC
V54C3256164VBUC/T
Timing Diagrams
1. Bank Activate Command Cycle
2. Burst Read Operation
3. Read Interrupted by a Read
4. Read to Write Interval
4.1 Read to Write Interval
4.2 Minimum Read to Write Interval
4.3 Non-Minimum Read to Write Interval
5. Burst Write Operation
6. Write and Read Interrupt
6.1 Write Interrupted by a Write
6.2 Write Interrupted by Read
7. Burst Write & Read with Auto-Precharge
7.1 Burst Write with Auto-Precharge
7.2 Burst Read with Auto-Precharge
8. Burst Termination
8.1 Termination of a Burst Write Operation
8.2 Termination of a Burst Write Operation
9. AC- Parameters
9.1 AC Parameters for a Write Timing
9.2 AC Parameters for a Read Timing
10. Mode Register Set
11. Power on Sequence and Auto Refresh (CBR)
12. Power Down Mode
13. Self Refresh (Entry and Exit)
14. Auto Refresh (CBR)
Loading...
+ 31 hidden pages