5
V53C832L Rev. 1.6 August 1999
MOSEL VITELIC
V53C832L
AC Characteristics
T
A
= 0 °C to 70°C, V
CC
= 3.3V ± 0.3V, VSS = 0V unless otherwise noted
AC Test conditions, input pulse levels 0 to 3V
# Symbol Parameter
30 35 40
Unit NotesMin. Max. Min. Max. Min. Max.
1 t
RAS
RAS Pulse Width 30 75K 35 75K 40 75K ns
2 t
RC
Read or Write Cycle Time 65 70 75 ns
3 t
RP
RAS Precharge Time 25 25 25 ns
4 t
CSH
CAS Hold Time 30 35 40 ns
5 t
CAS
CAS Pulse Width 5 6 7 ns
6 t
RCD
RAS to CAS Delay 15 20 16 24 17 28 ns
7 t
RCS
Read Command Setup Time 0 0 0 ns 4
8 t
ASR
Row Address Setup Time 0 0 0 ns
9 t
RAH
Row Address Hold Time 5 6 7 ns
10 t
ASC
Column Address Setup Time 0 0 0 ns
11 t
CAH
Column Address Hold Time 5 5 5 ns
12 t
RSH (R)
RAS Hold Time (Read Cycle) 10 10 10 ns
13 t
CRP
CAS to RAS Precharge Time 5 5 5 ns
14 t
RCH
Read Command Hold Time
Referenced to CAS
0 0 0 ns 5
15 t
RRH
Read Command Hold Time Referenced to RAS 0 0 0 ns 5
16 t
ROH
RAS Hold Time Referenced to OE 6 7 8 ns
17 t
OAC
Access Time from OE 10 11 12 ns 12
18 t
CAC
Access Time from CAS 10 11 12 ns 6,7,14
19 t
RAC
Access Time from RAS 30 35 40 ns 6, 8, 9
20 t
CAA
Access Time from Column Address 16 18 20 ns 6,7,10
21 t
LZ
OE or CAS to Low-Z Output 0 0 0 ns 16
22 t
HZ
OE or CAS to High-Z Output 0 5 0 6 0 6 ns 16
23 t
AR
Column Address Hold Time fromRAS 26 28 30 ns
24 t
RAD
RAS to Column Address Delay Time 10 14 11 17 12 20 ns 11
25 t
RSH (W)
RAS or CAS Hold Time in Write Cycle 10 10 10 ns
26 t
CWL
Write Command to CAS Lead Time 10 11 12 ns
27 t
WCS
Write Command Setup Time 0 0 0 ns 12, 13
28 t
WCH
Write Command Hold Time 5 5 5 ns
29 t
WP
Write Pulse Width 5 5 5 ns
30 t
WCR
Write Command Hold Time from RAS 26 28 30 ns
31 t
RWL
Write Command to RAS Lead Time 10 11 12 ns
32 t
DS
Data in Setup Time 0 0 0 ns 14
33 t
DH
Data in Hold Time 5 5 5 ns 14