MOSEL VITELIC
V53C16126H
5
V53C16126H Rev. 1.3 February 1998
AC Characteristics
T
A
= 0 ° C to 70 ° C, V
CC
= 5 V ± 10%, V
SS
= 0V unless otherwise noted
AC Test conditions, input pulse levels 0 to 3V
# Symbol Parameter
30 35 40 45 50
Unit NotesMin. Max. Min. Max. Min. Max. Min. Max. Min. Max.
1 t
RAS
RAS Pulse Width 30 75K 35 75K 40 75K 45 75K 50 75K ns
2 t
RC
Read or Write Cycle Time 65 70 75 80 90 ns
3 t
RP
RAS Precharge Time 25 25 25 25 30 ns
4 t
CSH
CAS Hold Time 30 35 40 45 50 ns
5 t
CAS
CAS Pulse Width 5 6 7 8 9 ns
6 t
RCD
RAS to CAS Delay 15 20 16 24 17 28 18 32 19 36 ns
7 t
RCS
Read Command Setup Time 0 0 0 0 0 ns 4
8 t
ASR
Row Address Setup Time 0 0 0 0 0 ns
9 t
RAH
Row Address Hold Time 5 6 7 8 9 ns
10 t
ASC
Column Address Setup Time 0 0 0 0 0 ns
11 t
CAH
Column Address Hold Time 5 5 5 6 7 ns
12 t
RSH (R)
RAS Hold Time (Read Cycle) 10 10 10 10 10 ns
13 t
CRP
CAS to RAS Precharge Time 5 5 5 5 5 ns
14 t
RCH
Read Command Hold Time
Referenced to CAS
0 0 0 0 0 ns 5
15 t
RRH
Read Command Hold Time
Referenced to RAS
0 0 0 0 0 ns 5
16 t
ROH
RAS Hold Time
Referenced to OE
6 7 8 9 10 ns
17 t
OAC
Access Time from OE 10 11 12 13 14 ns 12
18 t
CAC
Access Time from CAS 10 11 12 13 14 ns 6,7,14
19 t
RAC
Access Time from RAS 30 35 40 45 50 ns 6, 8, 9
20 t
CAA
Access Time from Column
Address
16 18 20 22 24 ns 6,7,10
21 t
LZ
OE or CAS to Low-Z Output 0 0 0 0 0 ns 16
22 t
HZ
OE or CAS to High-Z Output 0 5 0 6 0 6 0 7 0 8 ns 16
23 t
AR
Column Address Hold Time from
RAS
26 28 30 35 40 ns
24 t
RAD
RAS to Column Address
Delay Time
10 14 11 17 12 20 13 23 14 26 ns 11
25 t
RSH (W)
RAS or CAS Hold Time in
Write Cycle
10 10 10 10 10 ns
26 t
CWL
Write Command to CAS
Lead Time
10 11 12 13 14 ns
27 t
WCS
Write Command Setup Time 0 0 0 0 0 ns 12, 13
28 t
WCH
Write Command Hold Time 5 5 5 6 7 ns