Morris MDD-86250 User Manual

Page 1
Page 2
CONTENTS
Safety Instructions 02
Installation
Parts
Control Panel
Quick reference guide
Positioning the dehumidier
Water Drainage
Care and Maintenance
Frequently Asked Questions
Troubleshooting
Technical Data
15
04
05
07
10
13
15
17
18
19
20
01
Page 3
SAFETY INSTRUCTIONS
Important
Carefully read the instructions before operating the unit. This appliance only intended for use in an indoor domestic environment. Any other use is not recommended by the manufacturer and may cause fire, electrical shocks or other injury to person or property. Rating: This unit must only be connected to a AC 220-240V / 50 Hz earthed outlet. Installation must be in accordance with regulations of the country where the unit is used.
If you are in any doubt about the suitability of your electrical supply have it checked
and, if necessary, modified by a qualified electrician. This dehumidifier has been tested and is safe to use. However, as with any electrical appliance – care must be taken during use. Disconnect the power plug from socket before dismantling, assembling or cleaning. Avoid touching any moving parts of the appliance. Never insert fingers, pencils or any other objects through the guard. This appliance is physical, sensory or mental capabilities. It is also not inended for use by those with a lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Do not leave children unsupervised with this appliance. Do not clean the unit by spraying it or immersing it in water. Never connect the unit to an electrical outlet using an extension cord. If a power outlet is not available, one should be installed by a qualified electrician. Never operate this appliance if the cord, power adapter or plug is damaged. Ensure the power cord is not stretched or exposed to sharp object/edges. A damaged power supply cord should be replaced by the manufacturer or a qualified electrician in order to avoid a hazard. Any service other than regular cleaning or filter replacement should be performed by an authorized service representative. Failure to comply could result in a voided warranty. Do not use the appliance for any other purpose than its intended use. Do not tilt the unit while in use. The unit is designed to work only in a vertical position. This dehumidifier must always be stored upright, otherwise irreparable damage may be caused. This unit will still operate for approximatively 3-4 minute after pressing the power off button. This is normal and ensures the desiccant wheel is drained of water. Avoid restarting the dehumidifier unit unless 5 minutes have passed since being turned off. Never use the mains plug as a switch to start and turn off the dehumidifier. Use the provided ON/OFF switch located on the control panel. Always place the unit on a dry and stable surface. The appliance should not be installed in a laundry or wet room where the humidity is higher than 85% RH. This unit should be operated at an ambient temperature between 1°C and 32°C.
not intended for use by persons (including children) with reduced
Do not dry laundry directly above the unit. To prevent water entering the dehumidifier, laundry should be placed at least 40 cm away from your dehumidifier. Do not place the unit next to heat sources( e.g. electrical fires, fireplaces, etc.) Desiccant dehumidifiers tend to absorb odours from the surrounding environment like cigarettes, cooking, cosmetics, new furniture etc. This smell
described as a burning or sour smell. This released during operation as the zeolite disc is heated during operation. This is not sign of a fault and the smell will fade with the time. Do not store or use gasoline, petrol, paint, solvents or other flammable vapours and liquids in the vicinity of this dehumidifier or any other appliance. Do not use dehumidifiers where flammable gases or VOC can be released or accumulate.
Energy Saving and Unit Safety Protection Tips
Do not cover or restrict the airflow from the outlet or inlet grills. For maximum performance the minimum distance from a wall should be 20 cm and it should be kept 50 cm from objects within the room. Keep the filters or grills of the unit clean. Under normal conditions, filters or grills should only need cleanig once every the mesh air filter as this will allow dirt to gather inside the dehumidifier and could invalidate the warranty. A dirty filter will restrict the air flow into the machine which will increase the resistance on the fan and could result in damage and might invalidate the warranty. Since the filters remove airborne particles, more frequent cleaning maybe necessary depending on the air quality. Vacuum and wash the mesh filters with hot soapy water and dry them before placing them back in the unit.
Quick visual safety guide on where or when not to use your dehumidier
Exposed to the
weather outdoors
On an extension lead
may become
overloaded
Where the power cable
may be damaged
three weeks (approximately). Do not use the unit without
Near water
If the power cable
wires are frayed or cut
On a slope or
uneven surface
Where small children
may be left unattended
Where there is risk
of re or close to a
naked ame
Where it may be
damaged by
chemicals
Where there is a risk
or interference by
foreign objects
02 03
This product is not
made for DIY repair
If there is a risk
of water faling on the
unit
Page 4
Installation
Remove any water from the water tank before starting the unit. In order to save energy, do not open windows or doors while the unit is running. Place the unit on a hard / flat surface. We would advise the unit is running continuously for 24hrs on its first use
To reduce noise levels:
Place a piece of carpet or a rubber mat under the unit to reduce any vibrations while the unit is running. For minimum noise run the unit in sleep mode.
Features :
Your MDD-86250 is a top of the range desiccant dehumidifiers with features not found in other units.
1.
Efficient, easy to use, quiet.
2.
Intelligent CPU controlled digital humidistat wit Dehumidifier / and Air purifier), 35-80% RH adjustable and room humidity display,3 colors changeable according to
3. ambient humidity,Red color means high humidity (above 80%), Green color means comfortable (80%≥RH≥60%),Blue color Dry (below 60%). Air Purifier mode
4. Turbo and Sleep modes for the right balance between quiet operation and maximum
5. dehumidification. Easy to use control panel with led indicators.
6. 5 stage air purifier , with nano-silver coated filter,active carbon filter,HEPA
7. filter,Ionizer,UV light Works very well at low temperatures compared with classic compressor dehumidifiers.
8.
9.
Great landry mode to help clothes drying. Heats the air passing through between 5-10°C, making the air dry and warm reducing
10. the heating bills. Tank full alarm & auto-stop function.
11.
Recessed carry handle for portability
12.
MORRIS MDD-86250 desiccant dehumidifiers use compressor free desiccant technology to extract and low temperatures working on ambient range of between 1-32°C, MORRIS MDD­86250 desiccant dehumidifiers are light and easy to move, as they do not contain a heavy compressor. They also work intelligently as they are designed to extract unwanted humidity while saving money due to their advanced power saving logic. They feature an intelligent digital humidistat with variable humidity settings at 35-80% RH ensuring your room is not dried too much and power is not wasted. The MORRIS MDD-86250 also feature a powerful laundry mode and a sleep mode giving the user the ability to select maximum dehumidification, or quieter operation.
water from the environment. The desiccant dehumifiers are ideal both at standard
h 4 modes continous(SMART / Heater /
PARTS
Air outlet Front display
3 color light
Power cord
Control Panel
Pre-lter/activated Carbon filter
Continuous Drain Port
Top display
Handle
Louvres
Water tank
04 05
Page 5
ACCESSORIES Activated
carbon filter
HEPA FILTER
5stage dual action dehumidifier and purifier great in improving indoor air quality
CONTROL PANEL
Ion Down Up Mode
Timer Oscillation UV Fan speed Power
Power button
Turn on/ off the unit
Polluted Humid air
Pre-filter
HEPA filter
Activated Carbon filter
Clean dry air
Ioniser
UV Light
Mode button
Select the function of the unit between :Smart / Heater / Dehumidifier / Air Purifier Smart mode : The unit will default to Smart mode the first time it is switched on and remains in this mode until another program is chosen. In Smart mode,the target humidity is set to 50%RH,the fan speed will be adjusted automatically.The target humidity can not be changed in this mode Heater / Dehumidifier mode -This allows the user to select the desired temperature / humidity for the room. Air purifier mode -This will help to improve the indoor air quality. 6 stage dual purifier system. No water will be extracted in this mode,only the fan is working.
Fan speed This allows to adjust the fan speed of unit,and output of dehumidify / heater capacity. Turbo: High speed,the heating element is fully on,maximum output of dehumidify / heater (No heating when air purifier mode) Normal : Middle speed,half of the heating element is on , standard output of the dehumidify / heater (no heating when air purifier mode ) Sleep : low speed,half of the heating element is on,low output of dehumidify / heater (no heating when air purifier mode)
06 07
Page 6
OSC.(Oscillation function)
There are three different option for the outer louver on the unit,it can be set at 45 or 90 degrees,or alternatively to swing. Use the dehumidifier at a 45 degree angle or with swing for laundry mode
UV Light (For air purifier function)
To activate the UV function press the UV button will illuminate. The UV light will destroy germs,bacteria,greatly improve the indoor air quality.
PLASMA IONISER Button (ionization function)
To activate the ionizer press the Plasma Ioniser button. The LED to the right of the button will illuminate to show the mode is active. The ionizer can refresh the air while killing viruses, dust mites, mould and airborne allergens.
HUMIDITY
In dehumidification mode, press the up and down keys to set the target humidity (35~80%, one grid per 5%)
When a relative humidity of 35% is selected, the unit will not stop until the water tank is full. Please note these buttons will not adjust the desired humidity in smart mode. In the heating mode, press the up and down keys to set the target temperature (16~30 oC, one grid per 1 oC)
TIMER Button
When the button is pressed, the led to the left of the button will illuminate to show the mode has been activated. The timer can be turned off again by pressing the timer button. The indicator LED will then turn off. The Timer can be used in 2 different ways
Delayed power-on:
use the "UP" and "DOWN" buttons to select in how many hours time you require the unit to start.
Delayed power-off:
use the "UP" and "DOWN" buttons to select in how many hours time you require the unit to turn off.
TANK-FULL
If the water tank is full, the indicator light will flash, please empty the water tank to continue operation. The light will also illuminate if the tank is incorrectly tted.
OPERATION
The Operation light will illuminate when the unit is running to extract moisture from the air. Please note this may not light up immediately when the unit is started, and will go out when the desired humidity is reached.
/TEMPERATURE
SETTING Buttons
With the unit in standby, activate the timer mode and
With the unit turned on, activate the timer mode and
and the indicator light
Humidity Level & Timer 2 digit display
The led indicator performs the following functions:
When the unit is plugged in When one of the humidity setting button is pressed -
humidity, before reverting to showing the current humidity after a few seconds
When the timer button is pressed it
function will operate, before reverting to showing the current humidity after a few seconds
When the humidity level is outside the normal operational parameters the display will
Notes:
show LO or HI. If ambient humidity is lower than 20%, it will show “LO” If ambient humidity is higher than 90%, it will show “HI”. The dehumidifying function will be deactivated until the humidity has re entered the normal range to prevent damage to the unit.
- It will indicate the room humidity level it will indicate the set
will indicate in how many hours the timer
Active carbon filter (air purification function)
Take out the carbon filte carbon filter every 2-3 weeks and change them every 3-6 months to always keep the room fresh and odour free.
r from bag and insert it on the filter. It is suggested to hoover the
(01) (02)
Clean the Grille and Case
Use water and a mild detergent to clean the washable mesh filters. Do not use bleach or abrasives. Do not splash water directly onto the main unit. Doing so may cause an electrical shock and can lead to the insulation to deteriorate, or cause the unit to rust. The air intake and outlet grilles get soiled easily, so use a vacuum attachment or soft brush to clean. Wipe the dehumidier body with a soft damp cloth or kitchen towel.
HEPA filter:
According to the time and frequency of use, it is generally recommended to replace the HEPA lter after about 3 months. (HEPA lter can not be washed)
08 09
Page 7
QUICK REFERENCE GUIDE
Air purifier Mode – No moisture will be extracted in this mode, which when used with filters will purify the air. The UV and ionizer can also be used in this mode to further improve the quality of air processed.
Power Button
Swing control Button
to lock at 45 degrees, press again to lock at 90 degrees. Do not operate the unit if the self­opening louvers do not open when the unit is powered on.
Timer Button:
to adjust the timer (1-24 hrs, start/ stopping timer). In power on mode the set number will represent the number of hours the unit will run for before turning off. This will remain unaffected if unit goes in to defrost mode or the tank is emptied than reinserted. In standby mode the set number represents the period in hours after which the unit will start. To cancel the timer press the timer button again.
Smart mode:
determine the wind speed and dehumidification capacity according to the current humidity of the room; the wind speed cannot be adjusted manually.
When the ambient humidity is >65%, the fan runs at high speed and the powerful
a:
dehumidication operation;
When the ambient humidity is between 55% and 65%, the fan normal runs the standard
b:
dehumidication capacity output;
When the ambient humidity is between 50% and 55%, the fan runs at a low speed (sleep)
c:
and outputs a lower dehumidication capacity;
When the ambient humidity is <50%, the fan runs at a low speed, without
d:
dehumidication output, and only circulates indoor air.
Press the power button to turn the dehumidier on and off.
Press once to make the louvres swing and press again
Press the timer button then use buttons
smart set the target humidity 50% and smart
Please note :
when heater / dehumidifier / smart mode is on,due to the large room space or
1, some other reasons,the target setting can not be reached even if the unit keeps on working for a long time.If the unit works continuously more than 8 hours,the unit will be shut off automatically
2,when heater / dehumidifier / auto mode is on,when the room temperature or humidity reaches the target,the heating element will be closed,and fan keeps on working for 5 minutes,fa motor and fan louver start to work again to detect the room temperature and humidity (a),if it is necessary to turn on (room temperature is less then 1C or room temperature is 2% above the settings),the heating element will be turned on to start the heating or dehumidify (b),if it is not necessary to turn on,the fan will continue to work 5 miniutes and then closed,fan louver is closed as well,display is still on. And then repeated as per the above logic
3) when heating / dehumidifier / smart mode is on,when the heating element is on,if power
off manually,the heating element will be shut off immediately,the fan motor will keep on working within 5 miniutes,in order to avoid destroying the unit.Fan motor and fan louver will stop after 5 minutes
n motor,fan louver will all closed,display is still on,and then,after 30 minutes,fan
for 5 minutes ,in order to radiate the inner heat,please do not remove the plug
Heater mode : The unit will work as per temperature control,the fan speed will work s
ame as last setting.The control panel will display room temperature,front panel display room humidity.The target temperature can be adjusted by the up & down button (16-30C,each step 1C).When adjusting the temperature,the data on control panel and front panel will flash together and display the settings.After it is set,the control panel will continue to display the temperature,and front panel humidity. Use the fan speed button to adjus the fan speed and output of heating capacity.
Dehumidifier mode : The unit will work as per humidity control, the fan speed will work same as last setting,the control panel will display the room humidity,the front panel displays (35-80%,each step 5%), when adjusting the humidity,the data on control panel and front panel will flash together and display the settings. After it is set,the control panel will continue to display the humidity,and front panel temperature. Use the fan speed button to adjus the fan speed and output of heating capacity.
room temperature,the target humidity can be adjusted by the up & down button
10 11
Page 8
laundry function: for the dehumidifier to operate continuously with maximum water extraction until the tank is full, set the unit to High Fan mode and set the desired humidity level
to 35%-50% RH. 35% is very dry and the unit will work until water tank is full as 35%RH is hardly achievable in The domestic environment. The louvres should be set to either swing mode or to 45 degrees directing the airflow onto clothes / laundry. Do not place clothes directly over the dehumidifier vents. Make sure that there are no obstructions to either the hot air exhaust air flow, or the air inlet. For best results place the laundry within 1.5 meters of the dehumidifier.
Please Note: If a permanent drainage pipe is fitted, the unit will not stop operation. Setting the desired humidity to around 35% is good for a drying boost, on the units initial run, or in emergencies. It is not recommended to use it with these settings for normal operation in domestic/ office environment over a long period of time, as the air may become uncomfortably dry.
For allowing more moisture in the air, press the humidity button to set to a higher percentage value (e.g. 60-70%). Humidity set to 50-55% RH - Recommended setting, great for domestic operation and dry storage. Humidity set to 60% RH - Great for personal comfort and applications where 50% RH is considered too dry. Humidity set to 70% RH - Ideal for unoccupied properties or where an economical run is needed without the need to go drier than 70% RH
Red color means high humidity, RH>80% Green color means comfortable, 80%≥RH≥60% Blue color means dry, RH<60%
REMOTE CONTROL
Turn on/off the lamp by pressing ION button three times within 5 seconds
press SWING button to display 90o/45o/OSC
Press the ION button to turn on / off
Press the UV button to turn/off
Press FAN button to display Turbo/Normal/Sleep
Press the timer button when the unit is power on,to turn on/off the display of "clock+OFF" icon,it will flash 5 seconds,then press up/down button to adjust the 1-24h. Press the timer button when the unit is power on,to turn on/off the display of "clock+ON" icon,it will flash 5 seconds,then press up/down button to adjust the 1-24h.
Press the MODE button to change SMART / HEATER / DEHUMIDIFIER / AIR PURIFIER mode Smart mode,it will display 50%,the data is not adjustable,fan button is not adjustable,fan speed icon will display,fan speed icon is fixed at 1-3 leve Heater mode,it will display 16-30C,adjust it by pressing up/down button Dehumidifier,it will display 35-80%,each step 5%
12 13
Page 9
Other features and Indicators
Tank Full Light
The red light will illuminate and the unit will beep when the tank is full and should be emptied, or if the water tank is incorrectly inserted. The water level control will shut off the dehumidifier until the empty tank is replaced in its proper position
Auto-Restart
If the unit stops unexpectedly due to the power cut, it will restart with the previous function selected smart when the power resumes.
Lightweight Portable Design on castors
The dehumidier is built to be compact and lightweight. The castors on the bottom of the unit make it easy to move from room to room. Your dehumidier is an advanced micro-CPU controlled device capable of self-diagnostics. The LCD display may also show the error and protection codes.
POSITIONING THE DEHUMIDIFIER
A badly positioned dehumidier will have little effect. In positioning the dehumidier please
ensure circulation of the air in not restricted around
the unit. At least 20 cm space should be allowed around the unit.
This dehumidier is designed for indoor residential / small ofce applications only and any commercial or industrial use will invalidate the warranty.
Use the dehumidifier in an enclosed area for maximum efficiency. Close all external doors and windows to create an effective operating environment. Do not use outdoors. Your dehumidier will begin to protect your space
from the harmful effects of excessive moisture as
soon as it is turned on. Excess moisture is dispersed throughout your home. For this reason, the dehumidier should be positioned in a central and clear location so that it can draw this moist air towards it from all over the home. A warm hallway or landing is an ideal position for your dehumidier. If possible, leave interior doors ajar to allow air circulation between rooms. Alternatively, if you have a serious problem in one area you can begin by positioning the dehumidifier in that area and moving it to a more central location at a later date. Please note the unit should not be placed directly against a radiator or other heat source. When positioning your dehumidier, ensure that it is placed clear of any obstacle that may limit the air movement, and it should be placed on a dry at surface.
Please Note:
with water in the tank as it may tip over and spill.
Do not force castors to move over carpet or uneven surfaces, nor move the unit
WATER DRAINAGE
When the water tank is full, the unit will stop running. When this happens the TANK FULL red light will show on the control panel.
Only empty the water tank when it is full or before moving or storing the unit.
ote:
N
There are two ways to dispense collected water.
Use the internal water tank.
When the tank is full, the unit will smart stop running, and the Full indicator light will ash. Grip the tank by its handle securely, and carefully pull out. Empty the water tank and reinsert it into the dehumidier. The tank must be in place and securely seated for the dehumidifier to operate again. The dehumidifier will re-start when the tank is restored to its correct position.
14 15
Page 10
NOTES:
Do not remove the water tank immediately after the unit stops. Please wait a while to avoid the water dripping into the unit and causing damage. Only empty the water tank when it is full or before moving or storing the unit. Do not rest the tank on the oor because the bottom of the tank could be uneven and tank may fall and cause the water to spill. When you remove the tank, do not touch sensors or any parts which are situated behind tank. Doing so may damage the product. Be sure to push the tank gently all the way into the unit. Banging the bucket against anything or failing to push it securely into place may cause the unit not to operate. Do not remove or damage the oat switch in the water-tank, otherwise the machine will stop working. Please make sure the water tank cover is put back into place correctly before the water tank is reinserted. If the water-tank is inserted incorrectly, the tank full indicator will flash. Remove the water tank and reinsert to turn the indicator off and resume normal use. At all times, avoid water entering the unit. It may cause an electrical hazard and damage the unit.
Set up continuous drainage (Select conguration)
This dehumidier has a continuous drain hole that can be connected to a plastic pipe with a 15 mm inner diameter (Not Supplied). Water can be smart plumbed in or drained into a sink, a larger receptacle or through the wall into an outside drain. Please follow the steps below to set your unit up for continuous drainage.
This unit uses gravity fall to dispose water hence the drain should be lower than the dehumidier water outlet. Be sure to run the water pipe downward and let the water ow out smoothly. Do not kink or bend the pipe.
NOTE: When the continuous drain feature is not being used, reverse the pipe installation, to start the water collecting in the water tank. The permanent drain can be used in conjunction with a water pump (e.g. when draining from a cellar) to lift the water upwards.
CARE AND MAINTENANCE
Always shut off the unit and unplug it from the mains before cleaning or performing any maintenance. When it is not in use for long periods, it is advisable to remove the plug from the power socket. Do not use chemical solvents (such as benzene, alcohol or gasoline) as they may cause irreversible damage to the unit.
Filter Cleaning
The Air-inlet may gather dust easily, please clean it often with a soft, damp cloth. If the lter is covered by dust, the airow and the performance of the unit will be affected, it may even cause damage to the unit. We recommend that you regularly clean the filters. The dehumidier must be disconnected from the socket before maintenance and the lters must be allowed to fully dry before re use.
Remove the filters from the unit, and tap the dust away.
1. Clean the carbon filter and the mesh filter with a vacuum cleaner or soft-brush.
2. If dirt and grease is accumulated wash the mesh filter in hot soapy water.
3. Replace the filters in position as shown in the diagram.
4.
Cut off the cover for the continuous drain on the back of the unit.
1. Pull out the water tank and connect a water tube of inner diameter 15mm to the drain
2. connector, and ensure the connection is tight * Please note,
supplied with the unit.
Return the water tank back into position within the unit.
3.
the water tube is not
16 17
Note: Never use the unit without the antibacterial mesh dust filter. The active carbon filter should be replaced if necessary after 3-6 months of usage.
Page 11
Clean the water tank
Every few weeks, clean the tank to prevent growth of mould, mildew and bacteria. Partially ll the tank with clean water and add a little mild detergent. Swish it around and than empty the tank and rinse. NOTE: Do not use a dishwasher to clean the tank. After cleaning and drying the tank must be reinserted securely into dehumidier in order to restart operation.
End of Season Maintenance
1. Empty and clean the water tank.
2. Clean the unit and the lters as per cleaning procedure above.
3. Coil the power cord on the special cord storage rest at the back of the unit.
4. Cover the unit and keep it in a dry place.
er Cord Maintenance and Replacement
Pow
If the power cord is damaged, it could cause a short circuit or become a fire risk. Please avoid pulling the cord, twisting or pressing it and keep it away from pets. If the power cord is damaged, power the unit off and unplug it immediately. Contact an electrician or service centre for repairs; do not attempt to repair the unit yourself.
FREQUENTLY ASKED QUESTIONS
Why doesn’t the unit work /or stops suddenly?
The water tank may be full or displaced. To retore: empty the tank and carefully place the tank back in the unit. Amount of water collected and size of the tank
1) When you first use your dehumidifier,it will work harder t
to 50%RH (default mode or the desired humidity set, if setting have been changed).This is the time when (even 2-3 times /day). As the room becomes dryer, the dehumidifier collects less water and it will take longer to fill the tank, this is perfectly normal. When the target relative humidity has been reached the dehumidifier will stop collecting water and will operate for longer periods in fan only mode, this is normal operation.The intelligent logic of your machine will save you money.
2) Unless you are using the unit to dry clothes, we recommen to set the desired humidity to
50-60%RH
3)If you find that you still have condensation on your windows or you need to dry the air further
then the be necessary if you have single glazed windows, the house is poorly insulated or if the outside air temperature drops towards freezing. Using in turbo mode will add more heat to your room and reduce your heating bill as dry air will heat quicker
4) For unoccupied properties,garages and etc.,use 60-70%RH with fan in turbo or sleep
mode according to your needs. That will ensure minimum power consumption while prevent moisture related issues.
it will produce the most water and as such will require emptying most frequently
40%RH or continuous mode can be used with fan set to turbo mode. This might well
o reduce the room humidity down
TROUBLESHOOTING
Problem Possible cause Solution
The unit does not work
Poor performance
Too noisy 1. unit is not placed on
The device does not dehumidify
The dehumidifie works, but relative humidity is still high
The window were clear and now condensation has returned
I can not remove the condensation from my window,even in continuous or laundry function
Dehumidifier is blowing out warm air
1. power is abnormal 2 water tank displaced or full 3 room temperature is too high or air-outlet is covered
1. Filter is dirty
2. Door & window are open
3. air-inlet or out-let is blocked
even surface.
2. Filter is blocked
The relative humidity in the room where the dehumidifier is operating is too low
1. The place is too large. This dehumidifier can dry up about a small five bedroom house
2. There are too many sources of moisture. Bathing,washing,drying clothes and cooking all puts moisture into the air
3. Paraffin or calor gas heating can add too much moisture into air
The outside air temperature has dropped significantly and the windows are colder
The surface temperature of the windows is too low for a dehumidifier to prevent condensation. Common with single glazed windows or poorly insulated houses when the outside temperature drops below o
o
C
The dried air is passes over a heating element before it is blown into the room as part of the dehumidification proces
1. contact an electrician to perform a repair
2. check water tank placement or empty water tank
3. lower room temperature
1. clean the filte
2. close door & windows
3. clean air-inlet & air-outlet
1. Place the unit on the flat surface.add carpet or rubber mat underneath
2. clean the filte
The dehumidifier dries down to the target relative humidity set and then goes into fan only mode until the relative humidity goes above the set point again
1. we recommend using a dehumidifier with a great capacity.Call customer service line for advice
2. we recommend using a dehumidifier with greater capacity
3. consider using an alternative heat sources
Set the dehumidifier to 40%RH and run for longer
Keep running the dehumidifier on Laundry 24hours a day and if the air temperature outside increases the condensation on windows may clear
This is normal and helpful especially in the cold weather,a dehumidifier is not an air cooler.
18 19
Page 12
Water not draining down the hose
Hose is fitted for continuous drainage but the water still goes into the tank
1. Negative air pressure in the room is pulling the water back into the dehumidifier overfl
2. Insert a 3mm hole into the top of the tube 25mm down from the spout.This will introduce air into the tube and balance out the air pressure
3. dirt is gather in the internal tray.May need servicing 4,Rubber bung not placed in the internal hole beyond tank 5,If fault persists then call the service center
Dehumidifie leaks water onto the floo
Machine not switching off the heater when desired humidity reached
Usually means that the dehumidifier is not on a level surface or that the filter has not bee cleaned often enough and dirt has fallen into the internal tray dehumidifie
Temperature and relative humidity sensor that reads the room reading is unable to read the correct readings
1. check that the water bucket is not cracked by filling it with water and placing it on kitchen paper on the kitchen side
2. check if filters are clea
3. if fault persists then call the service center
1. clean the fil er and blow the air sensor with a hover or hair dryer on cold setting to clean the sensor of fir
2. unplug the dehumidifier for 10 minutes to reset PCB and turn back on
3. if fault persists then call the service center
On pressing power off fan
Unit is drying internally before going in off mode
Normal operation.Do not
interfere still works for about 2-3 minutes and switches off
Unit stops after 8 hrs
Unit is cooling down,will restart after 30 minutes if
Normal operation. Do not
interfere
humidity is higher than set target
Note: When the fault can not be solved by the solutions above,please contact service center for help,do not attempt repairs
TECHNICAL DATA
Model No.
Rated Voltage 220-240V~ 50Hz
3
/h
o
C RH60%)
Dehumidify Capacity 10L/Day (20
Max Rated Input Power 710W
Tank Capacity 6.5 litres
Air Volume 190 m
Noise level 40 dB(A)
Net Weight 9.1 kg
All information provided is for reference only. Products specications may change due to continuous product development.
Disposal: Do not dispose this product as unsorted waste. Collection of such waste must be handled separately as special treatment is necessary.
NOTICE ABOUT RECYCLING
In the European Union there are separate collection systems for used electrical and electronic products. Please help us to conserve the environment we live in!
DECLARATION OF CONFORMITY
Herewith, Amiridis-Savvidis S.A. states that this product, complies with
the requirements of below directives:
EMC-Directive: 14 / 30 / EU Low Voltage Directive: 14/ 35 / EU RoHS Directive: 11 / 65 / EU
The detailed declaration of conformity can be found at www.morris.gr
Your product is designed and manufactured with high quality materials and components which can be recycled and reused. This symbol means that electrical and electronic equipment, at their end­of-life,should be disposed of separately from your household waste. Please dispose of this equipment at your local community waste collection/ recycling centre.
MDD-86250
20 21
Page 13
Loading...