Morphy Richards IB73305, IB73307, Ecovac 73301 Instructions Manual

www .morphyrichards.co.uk
Ecovac vacuum cleaner
Please read and keep these instructions
getting the best from your new cleaner...
If your cleaner isn’t picking up as well as it should, please check
• Dustbag
It is important to empty them when full, otherwise the performance of the cleaner will be impaired. Wash regularly in warm water and allow to air dry. A spare bag is provided.
• Filters
It is important that the filters are cleaned regularly to allow air through the appliance
• Blockages
Check the hose for blockages
• Belt
Check and replace damaged or broken belt
8407 Upright EcoVac ib 4 03/12/2002 1:34 PM Page 1
Important safety instructions
The use of any electrical appliance requires the following of common sense safety rules.
Primarily there is danger of personal injury and secondly danger of damage to the appliance and property. These are indicated in the instructions text by the following two conventions:
WARNING: Danger of personal injury
IMPORTANT: Damage to the appliance
In addition we offer the following essential safety advice.
Location
• Do not use or keep this product outside
when it is raining.
• Do not store the appliance near hot
ovens or heating appliances.
Mains lead
• Do not allow the mains lead to become
strained or run this appliance over it.
• If the electrical cable becomes damaged
the complete cable assembly must be
replaced. Do not attempt this task
yourself, contact Morphy Richards using
the helpline number.
Children
• Children do not understand the dangers
associated with operating electrical
appliances. Never allow children to use
this appliance.
Other safety considerations
• Never use in the presence of explosive
liquids or vapours.
• Never pick up inflammable or poisonous
liquids such as petrol, copier toner, or
other volatile substances. Never pick up
acids, asbestos or asbestos dust.
• Never use the appliance without the
filters installed.
• Never use the appliance to vacuum hot ashes, broken glass, sharp objects or liquids.
• Never modify the cleaner in any way.
• Always disconnect the appliance from the mains supply after use or prior to cleaning or replacing dust bags.
• The appliance should never be left running unsupervised.
• Repairs to electrical appliances are only to be undertaken by trained personnel. Unprofessional repairs can be dangerous for users.
• Use only genuine Morphy Richards spare parts and accessories
• Never over-extend the hose such that the cleaner is pulled over. If the cleaner is knocked over, switch off before attempting to upright.
• Never pick the cleaner up by the floor nozzle when connected to the mains, use the carrying handle.
•WARNING: Keep loose clothing, hair, fingers etc. away from the floor nozzle whenever the cleaner is connected to the mains.
• Disconnect from the mains supply before attempting to clear blockages, clear the brush or replace the belt.
Electrical requirements
Check that the voltage on the rating plate
of your appliance corresponds with your house electricity supply which must be A.C. (Alternating Current).
If the socket outlets in your home are not
suitable for the plug supplied with this appliance, the plug should be removed and the appropriate one fitted.
WARNING: The plug removed from
the mains lead, if severed, must be destroyed as a plug with bared flexible cord is hazardous if engaged into a live socket outlet.
Should the fuse in the 13 amp plug
require replacement, a BS1362 13 amp fuse must be fitted.
2
8407 Upright EcoVac ib 4 03/12/2002 1:34 PM Page 2
Features
Upper handle ¤ Flexible hoseMain bodyFurniture brushHose connectorCrevice nozzleNested extension tubes (2)
·
Carpet height adjustment knob
Exhaust filterFront panel
Full bag indicator  On/Off switch Ê Front cover release Á Floor nozzle with powered brush Ë Handle release È Carrying handle Í Cord storage with quick release cleat Î Safety bag interlock Ï Belt cover Ì Variable power slider Ó Belt tunnel blanking plate Ô Brush end plates
3
A
Accessories included
Extension tubes
Crevice tool
Furniture brush
¤
·
Á
Ê
Í
È
Â
Ë
Ì
8407 Upright EcoVac ib 4 03/12/2002 1:34 PM Page 3
Assembly
B
Warning: Do not plug in the cleaner until
it is assembled.
1 Carefully unpack all components. 2 Lift cleaner body to upright position. 3 Remove the two screws that are already
attached to the body.
4 From the rear of the cleaner, align the
handle with groove and slide into the body. If necessary, use thumb and finger pressure to slide handle into position.
5 Fasten the handle with the two screws.
Floor nozzle height adjustment
C
Before using the cleaner the floor nozzle
height must be set to the correct height.
Choose the setting which most closely matches your floor surface, ie deep carpet pile, medium carpet pile, short carpet pile or hard floor.
When using the attachments the cleaner must only be used in the upright position with the carpet height adjustment knob set to deep carpet.
Variable power
D
Slide the variable power control to the right to increase the suction power or to the left to decrease suction. This feature is most useful when using the hose & accessories. Use the minimum setting when vacuuming delicate fabrics/curtains etc. When not using the hose it is advisable to keep the variable slider set to maximum.
Using on carpets
1 Place cleaner in its upright position. 2 Set the carpet height adjustment knob to
the desired position. 3 Release the mains cable by revolving the
quick release cleat through 180º and
extend the cable fully.
4 Plug the cable into the mains socket. 5 Step on the handle release button to
release the handle to the desired position
E. 6 Press the on/off button to the ‘on’
position.
IMPORTANT: To prevent damage to carpets, never leave the cleaner switched on in one place for an extended period.
• Never have the brushes set too low such
that the cleaner is hard to push.
4
E
B
DEEP CARPET HARD FLOOR
C
Use attachments
Use
Clean under furniture
Flat position
min max
D
8407 Upright EcoVac ib 4 03/12/2002 1:34 PM Page 4
Using attachments
Follow previous steps 1-4 but set the carpet height adjustment knob to the deep carpet setting. 5 Remove the hose connector from the rear
of the cleaner and push the required
attachment firmly onto the end of the
hose.
• If additional length is required, attach one
or both extension tubes between the
hose and tool. 6 Switch on/off.
IMPORTANT: Never over extend the hose such that the cleaner is pulled over.
Dust bag condition
To obtain best results from your cleaner the dustbag needs to be emptied when necessary, otherwise the airflow and cleaning power will be reduced. When the dustbag indicator shows red continuously and performance deteriorates, first check if there are any blockages in the accessories or tubes. If these are clear, it is necessary to empty the dustbag.
If it is still showing red after emptying the dust bag and cleaning the filters, check to see if the hose is blocked.
Emptying the cloth dust bag
FG
1 Unplug power cable from wall socket. 2 Remove the front by pressing the cover
release lever at the top.
3 Remove the dust bag by holding the tab
and pull towards you. Remove carefully to avoid dust/dirt spilling from dust bag.
4 Hold the dustbag over a dustbin and
slide the clip from the bottom of the bag and tip the contents of the bag carefully into the bin. Shake the bag vigorously to remove excess dust.
5 Slide the clip back onto the bottom of the
dustbag and replace the dustbag. Push the dustbag fully back into position. Note: the front panel will not close unless the dustbag is correctly fitted.
6 Once the dust bag is in place, replace the
front panel by aligning the bottom locking tabs with the slots in the body, close cover slowly allowing the front panel to snap in place. The latch will self lock.
IMPORTANT: To maintain performance we recommend that the reusable bag is hand washed regularly in warm water. Do not use detergents as these could affect performance. Allow to dry naturally as direct heat may effect the material. A spare bag is provided for use while washing the other bag.
IMPORTANT: Ensure the dustbag is totally dry before refitting it into the cleaner.
5
F
Î
G
8407 Upright EcoVac ib 4 03/12/2002 1:34 PM Page 5
Changing the filters
H
To maintain suction, the filters must be regularly taken out and cleaned. Failure to clean the filters will reduce the suction and will damage the motor if used for prolonged periods. This may invalidate the guarantee. If the filters become damaged they must be replaced.
IMPORTANT: Do not operate the cleaner without the filters in place.
1 Remove the front cover of the cleaner. 2 The pre-motor filter is located underneath
the bag and the exhaust filter is below
facing forward. To remove the pre-motor
filter, simply slide it forward. To remove
the exhaust motor filter, pull the locking
tab on the right and it will snap out. 4 Remove the filters from their holders by
unclipping and shake vigorously over a
dustbin. The filters may also be washed
in warm water. Do not use detergents.
The filters must by completely dry before
re-fitting. Allow filters to dry naturally, do
not overheat. 5 Replace front cover.
Changing the brush belt
If the power brush stops rotating it is likely that the drive belt has snapped (usually because the brush has been stalled).
Replacement belts can be obtained from Morphy Richards or a Service Agent. 1 Disconnect the cleaner from the mains
supply. 2 Place the cleaner face down in the flat
position. 3 Use a cross-head screwdriver to remove
the two screws from the front bottom and
the central screw under the height
adjustment mechanism I. 4 Turn the cleaner over and remove the
carpet height adjustment knob. 5 Remove the two screws at the rear and
lift the rear of the cover off over the
handle release button and unclip the
cover from the front of the floor nozzle J. 6 If the belt has broken, remove any loose
pieces before replacing.
7 Lift the belt cover Ï off. 8 Grasp the brush at both ends and lift
straight up K.
6
H
I
J
8407 Upright EcoVac ib 4 03/12/2002 1:34 PM Page 6
9 Remove the belt tunnel blanking plate Ó. 10 Place one end of the new belt over the
motor shaft and the other around the pulley end of the brush L.
11 Make sure both brush end plates Ô are
fitted.
12 Place the belt tunnel blanking plate over
the belt and push end into its guide slot.
13 Align brush end plates with their guide
slots and push the brush down into place.
14 Re-fit the belt cover. 15 Re-fit the main cover. Push the carpet
height adjustment knob back on - do not over tighten.
16 Replace the two screws on the top of the
cover and the three screws underneath the floor nozzle.
Helpline
If you have any difficulty with your appliance, do not hesitate to call us. We’re more likely able to help than the store from where you bought the product.
Please have the following information ready to enable our staff to deal with your query quickly:
•Name of the product
• Model number as shown on the
underside of the appliance.
7
Helpline
& order line
for replacement parts
UK 08450 777700 Eire 1800 409119
L
K
Ï
Ó
Ô
8407 Upright EcoVac ib 4 03/12/2002 1:34 PM Page 7
Your two-year guarantee
It is important to retain the retailers receipt as proof of purchase. Staple
your receipt to this back cover for future reference. Please quote the following information if
the product develops a fault. These numbers can be found on the base of the product.
Model no. Serial no. All Morphy Richards Products are
individually tested before leaving the factory. In the unlikely event of any appliance proving to be faulty within 28 days of purchase it should be returned to the place of purchase for it to be replaced.
If the fault develops after 28 days and
within 24 months of original purchase, you should contact the helpline number quoting model number and serial number on the product, or write to Morphy Richards at the address shown. You will be asked to return the product (in secure, adequate packaging) along with a copy of proof of purchase. Subject to the exclusions set out below (1-6), the faulty appliance will then be repaired or replaced and dispatched usually within seven working days of receipt.
If for any reason this item is replaced
during the 2-year guarantee period, the guarantee on the new item will be calculated from original purchase date. Therefore it is vital to retain your original receipt or invoice
to indicate the date of initial purchase.
To qualify for the two-year guarantee the appliance must have been used according to the manufacturers instructions. For example bags and filters shall have been regularly cleaned or replaced.
Morphy Richards shall not be liable to replace or repair the goods under the terms of the Guarantee where: 1 The fault has been caused or is attributable
to accidental use, mis-use, negligent use or
used contrary to the manufacturers
recommendations or where the fault has
been caused by power surges or damage
caused in transit. 2 The appliance has been used on a voltage
supply other than that stamped on the
products. 3 Repairs have been attempted by persons
other than our service staff (or authorised
dealer). 4Where the appliance has been used for hire
purposes or non-domestic use. 5 Morphy Richards are not liable to carry out
any type of servicing work, under the
guarantee. 6 Consumables such as bags, filters and belt
are not covered by the guarantee.
This guarantee does not confer any rights other than those expressly set out above and does not cover any claims for consequential loss or damage. This guarantee is offered as an additional benefit and does not affect your statutory rights as a consumer.
• This guarantee is valid in the UK and
Ireland only.
8
VC73305M Rev 4 11/02
The After Sales Division, Morphy Richards Ltd, Mexborough, South Yorkshire, England, S64 8AJ
Helpline (office hours) UK (local rate)
0870 060 2603
Republic of Ireland 1800 409119
Morphy Richards products are intended for household use only
Morphy Richards has a policy of continuous improvement in product quality and design. The Company, therefore, reserves the right to change the specification of its models at any time.
8407 Upright EcoVac ib 4 03/12/2002 1:34 PM Page 8
Loading...