Morphy Richards IB70041, PremAir 70041 Instructions Manual

Page 1
PremAir cylinder vacuum cleaner
Please read and keep these instructions
getting the best from your new cleaner...
If your cleaner isn’t picking up as well as it should, please check
• Dustbags
• Filters
It is important that the filters are cleaned regularly or replaced to allow air through the appliance
• Blockages
Check the nozzle, tubes and hose for blockages
www.morphyrichards.co.uk
Page 2
2
Important safety instructions
The use of any electrical appliance requires the following of common sense safety rules.
Primarily there is danger of personal injury and secondly danger of damage to the appliance and property. These are indicated in the instructions text by the following two conventions:
WARNING: Danger of personal injury
IMPORTANT: Damage to the appliance
In addition we offer the following essential safety advice.
Location
Do not use or keep this product outside
when it is raining.
Do not store the appliance near hot
ovens or heating appliances.
Mains lead
Do not allow the mains lead to become
strained or run this appliance over it.
If the electrical cable becomes damaged
the complete cable assembly must be
replaced. Do not attempt this task
yourself, contact Morphy Richards using
the helpline number.
Children
Children do not understand the dangers
associated with operating electrical
appliances. Never allow children to use
this appliance.
Other safety considerations
Never use in the presence of explosive
liquids or vapours.
Never pick up inflammable or poisonous
liquids such as petrol, copier toner, or
other volatile substances. Never pick up
acids, asbestos or asbestos dust.
Always disconnect the appliance from the
mains supply after use or prior to
cleaning or replacing dust bags.
The appliance should never be left running unsupervised.
Product safety
Never use the appliance without the filter installed.
Never use the appliance to vacuum hot ashes, broken glass, sharp objects or liquids.
Never modify the cleaner in any way.
Repairs to electrical appliances are only to be undertaken by trained personnel. Unprofessional repairs can be dangerous for users.
Use only genuine Goblin spare parts and accessories.
Electrical requirements
Check that the voltage on the rating plate
of your appliance corresponds with your house electricity supply which must be A.C. (Alternating Current).
If the socket outlets in your home are not
suitable for the plug supplied with this appliance, the plug should be removed and the appropriate one fitted.
WARNING: The plug removed from
the mains lead, if severed, must be destroyed as a plug with bared flexible cord is hazardous if engaged into a live socket outlet.
Should the fuse in the 13 amp plug
require replacement, a BS1362 13 amp fuse must be fitted.
Page 3
3
Features
¤
Ê
Ì
Â
·
Á
Ë
È
Ï
Î
Í
Ò
Dust compartment cover ¤ Opening for suction hoseDust compartment lock buttonTool storage compartment coverPaper dustbagDustbag holderMotor protection filter
· Dustbag safety lockSlot for attaching dustbag holderVariable power controlOn/off foot switch  Cable rewind foot switch Ê Exhaust filter
Á ‘Bag full’ indicator Ë Suction hose with air flow control* È Suction hose with comfi-grip handle* Í Floor nozzle Î Two metal tubes* Ï Telescopic metal tubes* Ì Tube standby slot Ó Tube park (not shown) Ô Carrying handleHard floor brush* Ò Turbo brush*
* certain models only
Ô
Certain models only
Page 4
Standard accessories Application
Curtains and delicate fabrics
Textiles and upholstery
Shelves and hard surfaces
Carpets and other textile floor coverings (brushes up)
Settings for heavy dirt and smooth floors (brushes down)
4
Tools and accessories
Standard floor nozzle
This nozzle is suitable for general purpose cleaning on a wide variety of floor coverings.
Turbo brush (certain models only)
This nozzle is suitable for cleaning and rejuvenating cut pile carpets and is ideal for picking up stubborn dirt and pet hairs.
Hard floor brush (certain models only)
Designed specifically for use on wood, tiles and all other hard floor types.
Tool storage
The upholstery nozzle and the crevice tool are stored in the internal storage compartment.
Operation
Suction hose
Snap the 360° rotating head on the suction hose into the suction hose opening on the vacuum cleaner.
The appropriate cleaning tool can be attached directly to the other end of the suction hose or the connecting tube can be used between the suction hose and the tool.
Switching on
Always pull out the supply cable to its maximum length. Plug the appliance into the mains supply. Ensure that the electronic suction power control is set to minimum by turning the dial anti­clockwise as far as it will go. Push the on/off foot switch to start the motor.
Page 5
5
Power setting Application
Curtains and delicate fabrics
Textiles and upholstery
Floor coverings
such as rugs or economy setting for carpets
Carpets or
hard floor
coverings
Open Closed
Controlling suction power
The suction power can be varied to suit the surface being cleaned, by using the variable power control. See table for guideline settings.
Certain models only
The suction power can also be adjusted using the fingertip control on the handle.
Closed: full suction
Open: low suction
Overheating protection
In the event of a motor overload, your vacuum cleaner will switch off automatically. If this occurs, press the on/off switch, disconnect from the mains supply and leave for 15 minutes to allow the motor cool down.
The vacuum cleaner cuts out automatically when:
The floor nozzle or tubes become
blocked
Using the vacuum cleaner with a full
dustbag
The motor protection filter is very dirty
The exhaust filter is very dirty.
Check and rectify before attempting to reuse your vacuum cleaner.
IMPORTANT: Do not use your vacuum cleaner without the filters fitted.
Page 6
6
Tube standby
During short breaks in cleaning the tubes can be held in an upright, ‘standby’ position, whilst you move furniture for instance.
IMPORTANT: Ensure that the appliance is never left unattended whilst it is switched on.
Switching off
Switch off the appliance. Remove the plug from the mains supply and rewind the power cable using the cable rewind foot switch.
WARNING: When using the cable rewind, always hold the plug as the cable will rewind quickly.
Storage
Tube park
The vacuum cleaner can be stored in an upright position. Rotate the floor nozzle until the lug on the back of it can be fitted into the tube park slot on the base of the appliance.
Page 7
7
a
a
a
a
a
a
aa
a
aaa
a
a
a
a
a
a
a
aa
a
aa
aaa
Changing the dustbag
If suction power is reduced or if the ‘dust bag full’ indicator is permanently on, the dust bag needs changing. Also check whether the suction hose, tube or nozzle are blocked.
To access the dust bag, press the dust compartment release button to open the cover.
1 Pull the tab on the dust bag to one side
so that the opening is hygienically sealed. 2 Pull out the dust bag holder and dust bag
in an upward direction.
3 Pull the bag sideways out of the holder. 4 Dispose of the bag with your household
waste.
5 Insert a new dust bag in the holder. 6 Replace the dust bag holder and close
the cover.
IMPORTANT: The dust bag compartment cover can only be closed once a dust bag has been correctly inserted.
Page 8
8
Changing the motor protection filter
The motor protection filter varies by model. It is accessible from the dust compartment only when the dust bag has been removed first.
IMPORTANT: Never use the appliance without the motor protection filter installed, otherwise damage to the motor may occur which would not be covered by the guarantee.
PremAir model with standard micro hygiene filter
1 Open the flap on the filter holder. 2 Take out the filter and clean (by shaking)
or replace. 3 Close the filter holder.
It is recommended that this filter is cleaned everytime the dustbag is changed, and is replaced every 5 dustbag changes.
PremAir models with 3-layer hygiene filter cassette
1 Pull out the filter cassette in an upward
direction and clean by tapping gently or
dispose of it with your household waste. 2 Put in a new filter cassette.
It is recommended that this filter should be cleaned everytime the dustbag is changed and replaced every 6 months, or sooner if it starts to give an unpleasant odour or if the dust bag has been damaged.
IMPORTANT: The filter material is sensitive. Do not press the surface or you may damage the filter material.
Insert the dust bag and close the dust bag compartment cover.
Page 9
9
a
a
a
a
a
a
a
aa
a
aa
aaa
Changing the exhaust air filter
The exhaust air filter should be cleaned by shaking every time the dustbag is changed. This filter can also be washed in warm water (no detergents added) and allowed to dry naturally.
IMPORTANT: The filter must be totally dry before putting it back into the cleaner.
Cleaning and maintenance
Unplug from the mains before cleaning. The vacuum cleaner, especially the dust compartment and all accessories can be cleaned using a damp cloth or a non­abrasive domestic cleaner and wiped dry.
To keep the underside of the floor nozzle clean, vacuum it at regular intervals using the crevice tool.
Purchasing replacement filters
Use only Morphy Richards replacement filters which can be purchased from specialist retailers or by calling the number on the front page of this leaflet.
Helpline
If you have any difficulty with your appliance, do not hesitate to call us. We’re more likely able to help than the store from where you bought it.
Please have the following information ready to enable our staff to deal with your query quickly:
Name of the product
Model number as shown on the
underside of the appliance
Serial number
Page 10
10
The British Allergy Foundation considers that these products may, in proper use, reduce
exposure to both House Dust Mite (Der p 1) and Cat Allergen (Fel d 1).
Assessment carried out by BAF indicate that an individuals exposure can be reduced but this does not mean that an individuals allergic symptoms will necessarily diminish. BAF’s opinion applies only to the products and allergen stated. The product should be used only for its intended purpose and strictly in accordance with the manufacturers instructions at all times.
Exposure to allergen can be dangerous. If you believe that you may suffer from an allergy you should seek medical advice.
The British Allergy Foundation is a national charity (Charity reg. no. 1003726) founded in 1991 with the aim of improving awareness, prevention and treatment of allergy. The Foundation encompasses all types of allergy and is managed by medical specialists from a variety of disciplines including dermatology, ENT surgery, respiratory medicine, paediatrics, ophthalmology, immunology and gastroenterology.
The Foundation is continuously striving to help sufferers to help themselves, often seeking ways to avoid, or reduce exposure to, relevant allergens. The Seal of Approval Scheme forms a part of this initiative.
PremAir 1800 and PremAir 1800 Trio cylinder vacuum cleaners
F
O
U
N
D
A
T
I
O
N
T
H
E
B
R
I
T
I
S
H
A
L
L
E
R
G
Y
S
E
A
L
O
F
A
P
P
R
O
V
A
L
Page 11
11
Your three-year guarantee
It is important to retain the retailers receipt as proof of purchase. Staple your receipt to this back cover for future reference. Please quote the following information if
the product develops a fault. These numbers can be found on the base of the product.
Model no. Serial no. All Morphy richards products are
individually tested before leaving the factory. In the unlikely event of any appliance proving to be faulty within 28 days of purchase it should be returned to the place of purchase for it to be replaced.
If the fault develops after 28 days and
within 36 months of original purchase, you should contact the Helpline number quoting model number and serial number on the product or write to us at the address on the back cover. Assuming that a repair is necessary, we will arrange for our service agent to contact you and make an appointment to carry out the repair. The faulty appliance will then be repaired or replaced usually within seven working days. Repair or replacement of the product is subject to the exclusions set out below (1-5).
If you suspect a fault, follow the simple
checks detailed below before returning the appliance or calling the helpline.
Check the dust bag and filters for blockages.
Check the hose and tubes for blockages.
Check the plug is firmly in the socket and the supply is switched on.
Make sure the socket is working by trying another appliance.
If for any reason this item is replaced during the three-year guarantee period, the guarantee on the new item will be calculated from original purchase date. Therefore it is vital to retain your original receipt or invoice to indicate the date of initial purchase.
To qualify for the three-year guarantee the appliance must have been used according to the manufacturers instructions. For example bags and filters should be changed or cleaned regularly.
Morphy richards shall not be liable to replace or repair the goods under the terms of the Guarantee where: 1 The fault has been caused or is attributable
to accidental use, misuse, negligent use or
used contrary to the manufacturers
recommendations or where the fault has
been caused by power surges or damage
caused in transit. 2 The appliance has been used on a voltage
supply other than that marked on the
products. 3 Repairs have been attempted by persons
other than our service staff (or authorised
dealer). 4 Where the appliance has been used for hire
purposes or non-domestic use. 5 The guarantee excludes consumables such
as bags and filters.
This guarantee does not confer any rights other than those expressly set out above and does not cover any claims for consequential loss or damage. This guarantee is offered as an additional benefit and does not affect your statutory rights as a consumer.
This guarantee is valid in the UK and
Ireland only.
Page 12
12
51570121 Rev 1 7/01
The After Sales Division, Morphy Richards Ltd, Mexborough, South Yorkshire, England, S64 8AJ
Helpline (office hours) UK (local rate) 08450 777700 Republic of Ireland 1800 409119
Morphy Richards products are intended for household use only
Morphy Richards has a policy of continuous improvement in product quality and design. The Company, therefore, reserves the right to change the specification of its models at any time.
For additional information on Goblin products www.morphyrichards.co.uk
Loading...