Morphy richards 73340 user Manual

www.morphyrichards.com
Ultralight vacuum cleaner
Please read and keep these instructions
getting the best from your new cleaner...
If your cleaner isn’t picking up as well as it should, please check
• Dustbag
It is important to replace them when full, otherwise the performance of the cleaner will be impaired.
• Filters
It is important that filters are cleaned and replaced regularly to allow air through the appliance.
• Blockages
Check the hose, tubes and tools for blockages
• Belt
Check and replace damaged or broken belt
• Height adjustment
The height adjustment only comes into effect when the handle is released by the handle release pedal Â.
73340 Rev 1 4/3/05 10:29 AM Page 1
Important safety instructions
The use of any electrical appliance requires the following of common sense safety rules.
Primarily there is danger of personal injury and secondly danger of damage to the appliance and property. These are indicated in the instructions text by the following two conventions:
WARNING: Danger of personal injury
IMPORTANT: Damage to the appliance
In addition we offer the following essential safety advice.
Location
• Do not use or keep this product outside
when it is raining.
• Do not store the appliance near hot
ovens or heating appliances.
Mains lead
• Do not allow the mains lead to become
strained or run this appliance over it.
• If the electrical cable becomes damaged
the complete cable assembly must be
replaced. Do not attempt this task
yourself, contact Morphy Richards using
the helpline number.
Children
• Children do not understand the dangers
associated with operating electrical
appliances. Never allow children to use
this appliance.
Other safety considerations
• Never use in the presence of explosive
liquids or vapours.
• Never pick up inflammable or poisonous
liquids such as petrol, copier toner, or
other volatile substances. Never pick up
acids, asbestos or asbestos dust.
• Never use the appliance without the bag
or filters installed.
• Never use the appliance to vacuum hot ashes, broken glass, sharp objects or liquids.
• Never modify the cleaner in any way.
• Always disconnect the appliance from the mains supply after use or prior to cleaning or replacing dust bags.
• The appliance should never be left running unsupervised.
• Repairs to electrical appliances are only to be undertaken by trained personnel. Unprofessional repairs can be dangerous for users.
• Use only genuine Morphy Richards spare parts and accessories
• Never over-extend the hose such that the cleaner is pulled over. If the cleaner is knocked over, switch off before attempting to upright.
• Never pick the cleaner up by the floor nozzle when connected to the mains, use the carrying handle.
•WARNING: Keep loose clothing, hair, fingers etc. away from the floor nozzle whenever the cleaner is connected to the mains.
• Disconnect from the mains supply before attempting to clear blockages, clear the brush or replace the belt.
Electrical requirements
Check that the voltage on the rating plate
of your appliance corresponds with your house electricity supply which must be A.C. (Alternating Current).
If the socket outlets in your home are not
suitable for the plug supplied with this appliance, the plug should be removed and the appropriate one fitted.
WARNING: The plug removed from
the mains lead, if severed, must be destroyed as a plug with bared flexible cord is hazardous if engaged into a live socket outlet.
Should the fuse in the 13 amp plug
require replacement, a BS1362 13 amp fuse must be fitted.
2
73340 Rev 1 4/3/05 10:29 AM Page 2
Features
Upper handle ¤ Flexible hoseMain bodyHose connector
Carpet height adjustment knob
Hepa filter grilleFront panel
·
Full bag indicator
On/Off switchFront cover release handleFloor nozzle with powered brush  Handle release Ê Carrying handle
Á Cord storage with quick release cleat Ë Hose clip slot È Hose clip Í Safety bag interlock (shown page 5) Î Belt cover (page 7) Ï Brush bar (page 7) Ì Motor shaft (page 7) Ó Brush bar end cap (page 7)
Accessories you should have
Ô
Furniture brush
Crevice tool Ò Nested extension tubes x 2
3
A
Accessories included
Extension tubes
Crevice tool
Furniture brush
Ô
Ò
¤
·
Â
Ê
Á
È
Ë
73340 Rev 1 4/3/05 10:29 AM Page 3
Assembly
B
WARNING: Do not plug in the cleaner
until it is assembled. 1 Carefully unpack all components. 2 Lift cleaner body to upright position. 3 Remove the two screws that are already
attached to the body.
4 From the rear of the cleaner, align the
handle with groove and slide into the body. If necessary, use thumb and finger pressure to slide handle into position.
5 Fasten the handle with the two screws.
Floor nozzle height adjustment
C
Before using the cleaner the floor nozzle
height must be set to the correct height.
Choose the setting which most closely matches your floor surface, ie. deep carpet pile, medium carpet pile, short carpet pile or hard floor.
• When using the attachments the cleaner
must only be used in an upright position
with the carpet height adjustment knob
set to DEEP CARPET.
Note: The height adjustment only comes into effect when the handle is released by the handle release pedal Â.
Using on carpets
1 Place cleaner in its upright position. 2 Set the carpet height adjustment knob to
the desired position.
3 Release the mains cable by revolving the
quick release cleat
1
/
2
a turn and extend
the cable fully.
4 Plug the cable into the mains socket. 5 Step on the handle release pedal to
release the handle to the desired position.
6 Press the on/off button to the ‘on’
position.
IMPORTANT: To prevent damage to carpets, never leave the cleaner switched on in one place for an extended period.
• Never have the brushes set too low such
that the cleaner is hard to push.
Using attachments
Follow steps 1-4 above but set the carpet height adjustment knob to the deep carpet setting. 5 Remove the hose connector › from the
rear of the cleaner. Lift the hose ¤ from
the top handle hook and push the
required attachment onto the end of the
hose.
• Push the required attachment firmly onto
the end of the hose.
• If additional length is required, attach one
or both extension tubes between the
hose and tool. 6 Switch on/off.
•IMPORTANT: Always fix the hose clip È
to the main body slot Ë when using the
hose and tools.
• Never over extend the hose such that the
cleaner is pulled over.
•Turning the cleaner sideways helps
prevent the cleaner being pulled along by
the stretch hose.
4
B
C
73340 Rev 1 4/3/05 10:29 AM Page 4
DEEP CARPET HARD FLOOR
TOOLS
MEDIUM CARPET
Dust bag indicator
When the cleaner is switched on, if the dust bag condition indicator is continuously showing red (or if the suction is reduced) the bag must be replaced and the filters cleaned.
If it is still showing red after emptying the dust bag and cleaning the filters, check to see if the hose is blocked.
Changing the dust bag
D
1 Unplug the power cable from the socket. 2 Remove the front by pressing the release
lever at the top. 3 Remove the old dustbag by holding the
cardboard tab and pull towards you.
Remove carefully to avoid dust/dirt
spilling from the dust bag and dispose. 4 Take a new dust bag and fold over the
top tab at the crease. Holding the
cardboard tab, push the bag over the
opening of the dirt discharge tube until it
is seated against the rear of the
enclosure. 5 The front panel will not close unless the
dust bag is correctly fitted due to the
safety bag interlock. Í Always check
and if necessary clean the pre-motor filter
every time your change the dust bag.
6 Once the new dust bag is in place,
replace the front panel by aligning the bottom locking tabs with the slots in the body, close cover slowly allowing the front panel to snap in place. The latch will self lock.
Cleaning the pre-motor filter
E
Everytime a new bag is fitted, the filter should be taken out and cleaned. Failure to clean the filter will reduce suction and will damage the motor if used for prolonged periods. This may invalidate the guarantee. If the filter becomes damaged it must be replaced.
IMPORTANT: Do not operate the cleaner without the filter in place.
1 Remove the front cover of the cleaner. 2 The pre-motor filter is located below the
bag. 3 To remove the filter, slide the holder out of
the machine. 4 Remove the filter from the holder by
unclipping. To clean shake vigorously
over a dustbin. * The pre-motor filter may also be washed
in warm water. * Do not use detergents. The filter must be
completely dry before refitting. Allow the
filter to dry naturally, do not overheat.
5 Replace front cover.
5
D
Í
E
73340 Rev 1 4/3/05 10:29 AM Page 5
Replacing the HEPA exhaust filter
F
The HEPA exhaust filter should be
replaced every 6 months.
• Replacement filters can be purchased from our replacement parts helpline.
1 Remove the front grille F to access the
HEPA filter.
Safety cut-out
If the cleaner overheats a motor
protection thermostat will automatically switch the motor off. If this happens, switch
the cleaner off, unplug from the power supply and leave the cleaner to cool for at least 30 minutes. Check the airways for
blockages, empty dust canister and clean the filters before restarting.
Changing the belt
If the brush bar stops rotating it is likely that the drive belt has snapped (usually because the brush has been stalled). A spare belt is supplied. Replacement belts can also be obtained from Morphy Richards.
Removing the floor nozzle cover
GH
1 Disconnect the cleaner from the mains
supply. 2 Press the handle release pedal and place
the cleaner face down, in the flat position
on a soft surface (eg carpet). 3 Use a cross-head screwdriver to remove
the four screws indicated G.
4 Turn the cleaner over. 5 While pressing the handle release
pedal lift the rear of the top cover,
unhook from the front then completely
remove the cover H.
6
G
H
F
73340 Rev 1 4/3/05 10:29 AM Page 6
7
Replacing the belt
IJ
6 Lift off the belt cover Î. 7 Gently pull the right hand side (belt side)
of the floor nozzle outwards and at the same time lift the brush bar Ï out of its location I.
8 If the belt has broken, ensure all pieces
are removed. Clean the motor shaft Ì.
9 Check the brush bar end caps. Ó 10 Fit the left hand end cap into the floor
nozzle.
11 Fit the right hand end cap onto the brush
bar.
12 Place one end of the new belt over the
motor shaft Ì and the other around the pulley end of the brush Ï.
13 Locate the left hand side of the brush bar
first, then while pulling the right hand side of the nozzle gently outwards and stretching the belt, lower the right hand side of the brush into its location.
14 Rotate the brush by hand to ensure it is
correctly and securely located.
15 IMPORTANT: Re-fit the belt cover. 16 Replace the top cover, hooking it in at the
front first and by pressing the handle release pedal to allow the rear to
correctly locate K.
17 Turn the cleaner face down and re-fit and
tighten the four fixing screws, do not overtighten.
18 Return the cleaner to its correct working
position before re-testing.
Helpline
If you have any difficulty with your appliance, do not hesitate to call us. We’re more likely able to help than the store from where you bought the product.
Please have the following information ready to enable our staff to deal with your query quickly:
• Name of the product
• Model number as shown on the
underside of the appliance.
K
J
I
Î
Ï
Ì
Ó
73340 Rev 1 4/3/05 10:29 AM Page 7
Your two-year guarantee
• It is important to retain the retailers
receipt as proof of purchase. Staple
your receipt to this back cover for future reference.
Please quote the following information if the product develops a fault. These numbers can be found on the base of the product.
Model no. Serial no.
All Morphy Richards Products are individually tested before leaving the factory. In the unlikely event of any appliance proving to be faulty within 28 days of purchase it should be returned to the place of purchase for it to be replaced.
If the fault develops after 28 days and within 24 months of original purchase, you should contact the helpline number quoting model number and serial number on the product, or write to Morphy Richards at the address shown. You will be asked to return the product (in secure, adequate packaging) along with a copy of proof of purchase. Subject to the exclusions set out below (1-
6), the faulty appliance will then be repaired or replaced and dispatched usually within seven working days of receipt.
If for any reason this item is replaced during the 2-year guarantee period, the guarantee on the new item will be calculated from original purchase date. Therefore it is vital to retain your original receipt or invoice to indicate the date of initial purchase.
To qualify for the two-year guarantee the appliance must have been used according to the manufacturers instructions. For example bags and filters should have been replaced and cleaned as necessary.
Morphy Richards shall not be liable to replace or repair the goods under the terms of the Guarantee where:
EXCLUSIONS 1 The fault has been caused or is
attributable to accidental use, mis-use,
negligent use or used contrary to the
manufacturers recommendations or
where the fault has been caused by
power surges or damage caused in
transit. 2 The appliance has been used on a
voltage supply other than that stamped
on the products. 3 Repairs have been attempted by persons
other than our service staff (or authorised
dealer). 4 Where the appliance has been used for
hire purposes or non-domestic use. 5 Morphy Richards are not liable to carry
out any type of servicing work, under the
guarantee. 6 Consumables such as bags, filters and
belt are not covered by the guarantee.
This guarantee does not confer any rights other than those expressly set out above and does not cover any claims for consequential loss or damage. This guarantee is offered as an additional benefit and does not affect your statutory rights as a consumer.
• This guarantee is valid in the UK and
Ireland only.
VC73340M UK Rev 1 01/05
The After Sales Division, Registered address, Morphy Richards Ltd, Mexborough, South Yorkshire, England, S64 8AJ
Helpline (office hours) UK
0870 060 2604
Republic of Ireland 1800 409119
Morphy Richards products are intended for household use only
Morphy Richards has a policy of continuous improvement in product quality and design. The Company, therefore, reserves the right to change the specification of its models at any time.
73340 Rev 1 4/3/05 10:29 AM Page 8
Loading...