MORECEVSE Wallbox Overview User manual

Wallbox Overview
Accessories of Mode C
Mode C Station Overview
Display Screen
LED
HOLDERPLATE STATION
SCREWS FOR HOLDER
30mm PLASTIC BOLTS
ALLEN KEY
30mm SCREWS
HOOK
On/Off
Charging Plug
Technical Parameters
Level 2 EV Charging Station
Installaon Method: Wall/Stand Mode: C(with plug) Cerficate: TUV,CE IP Rang: IP66 Rated Voltage: 230VAC±10% Rated Current: 16A Maximum Power: 11kw Phase Mode: Three Phase
Operang Temperature: -40℃~55
Enclosure Material: ABS+PC alloy Start Mode: Buon(default)
Instruction for Use
1 2
Distribution Box
Wall
Security Protecon: Warning and display funcons Open circuit protecon Output overcurrent protecon Input under voltage protecon Over temperature protecon Ground protecon Input overvoltage protecon Charge status detecon
Charging Station
Button Holder
Charging Plug Hook
Make sure the wallbox is connected to power
Hang the cable on the hook when it is not in use
Connect the EV and the wallbox with the EV charging cable
3
Press the buon on the right side
of the wallbox to start/stop charging
Installation Guide
REFERENCE PAPER
of installing screw hole size
Wall
Drill the holes
according to the
REFERENCE PAPER
Fix the PLATE
with 30mm SCREWS
on the wall
Hammer the
30mm PLASTIC BOLTS
into the holes
Take down the
REFERENCE PAPER
from the wall later
Embed STATION into
PLATE on the wall
This is the final completion pic,
you can put the HOOK
and HOLDER
anywhere you need
The cable can
be hung on the
HOOK and HOLDER
Tear off the protector
Wallbox Overview
Accessories of Mode A
HOOK
Display Screen
SOCKETPLATE STATION
30mm PLASTIC BOLTS
SCREW SHIM
ALLEN KEY
REFERENCE PAPER
Mode A Station Overview
LED
On/Off
30mm SCREWS
30mm METAL BOLTS
95mm SCREWS
Socket
Technical Parameters
Level 2 EV Charging Station
Installaon Method: Wall/Stand Mode: A(with socket) Cerficate: TUV,CE IP Rang: IP66 Rated Voltage: 230VAC±10% Rated Current: 16A Maximum Power: 11kw Phase Mode: Three Phase
Operang Temperature: -40to+55
Enclosure Material: ABS+PC alloy Start Mode: Buon(default)
Instruction for Use
Distribution Box
Wall
Charging Station Button
Hook Charging Plug
Security Protecon: Warning and display funcons Open circuit protecon Output overcurrent protecon Input under voltage protecon Over temperature protecon Ground protecon Input overvoltage protecon Charge status detecon
Make sure the walbox is connected to power
Press the buon on the right side of the wallbox
to start/stop charging
Hang the cable on the hook when it is not in use
Insert the plug into socket
Connect the EV and the wallbox with the EV charging cable
Installation Guide
REFERENCE PAPER
of installing screw hole size
Wall
Drill the holes according to
the REFERENCE PAPER
Fix the PLATE with
30mm SCREWS on the wall
30mm PLASTIC BOLTS
Hammer the
into the holes
Hammer the
30mm METAL BOLTS
into the holes
Take down the
REFERENCE PAPER
from the wall later
Embed STATION
into PLATE on the wall
Take out the plate from
the body of charging
SOCKET
Connect the inlet cable and
the power supply correctly
This is the final completion pic,
you can put the HOOK
anywhere you need
The cable can be hung on the
HOOK
Fix the SOCKET on the wall
with95mm SCREWS
and put the plate back to the
by ALLEN KEY
body of SOCKET
95mm SCREWS
Tear off the protector
Screw Shim
Illustration of Screen and LED
Start-up screen
(the version no. is for reference only)
Wait for the car to be ready
Wait for inserng the plug
During charging process
1.Real-me power
2.Three Live Wire data
3.Charging me
4.Power consumpon
5.Charging icon
6.PCB Temperature
Possible fault warning
Wait for idenficaon
Stop charging and wait for
pulling out the plug
1.Emergency stop
2.Over Current
3.Over Temperature
4.Leakage protecon
5.Short Current
IDLE CONNECTED CHARGING FINISHED ERROR
Instrucon
of LED Status
OFF
Note: When small problems like short current occur, the wallbox will automacally restart to
repair and connue charging. For serious failures, the system can not automacally recover, in order to remind the user of
this failure, aer the user pulls the plug, the system will automacally countdown 10 seconds to
restart
Connuous
light
Rolling
Connuous
light
Red
flashing
Security Warning
Failure to follow instrucons may result in danger!
Regularly check whether the charging staon has visible damage. There may be a electric
shock when operang the broken charging staon.
Make sure that all safety facilies are available at all mes and are tested regularly to
ensure they can operate normally.
If a ground fault occurs, it must be assumed that the cable carries voltage. Please confirm
that there’s no high-voltage power in the system before inspecng the charging staon.
Persons who install and use charging staons must obey the principles and regulaons
menoned to ensure the personal safety and equipment safety.
Before powering on the device, please confirm that the device is properly grounded to
avoid unnecessary accidents.
All tools’ unnecessarily exposed metal parts should be insulated to prevent them from
touching the metal frame to avoid short circuit.
Do not modify, retrofit, or change any part by yourself under any circumstances.
To ensure the service life and stable operaon of the charging staon, the operang
environment should be kept as clean as possible with a relavely stable temperature and humidity. The charging staon must not be used in flammable environment or environments with volale gas.
Be sure to confirm that the input voltage, frequency, circuit breakers and other condions of
the device meet the specificaons before the device is powered on.
Maintenance & Overhaul
In order to ensure the normal service life of the charging staon and reduce risk, maintenance must be performed within the specified me. The maintenance of the equipment must be completed by professionals with qualifed and safe maintenance tools.
The product is already packed in factory. During transportaon, strong impact and bumps should be avoided to avoid damage to the outer packaging of the product.
The product should be placed at an ambient temperature of -40
humidity of no more than 95%. The air should not contain acids, alkalis ot other corrosive gases and explosive gases.
AC charging staons are subject to stringent quality inspecons. Mode 2 Charging is subject to stringent quality inspecons. From the day of purchase, any problem of product quality can be reflected to the dealer within two years.
Any direct damage or malfuncon caused by neglect, incorrect use, installaon, usage, repair by the users or natural damage are not covered by the warranty.
(Please do not contact the manufacturer's phone for after-sales questions)
No.128,Aoti,Jianye District, Nanjing, Jiangsu, China
55℃ with a relave
MANUFACTURER
Nanjing LuAo international tradeCo.,Ltd.
+86-025-8662-3210
Wallbox-Übersicht
Zubehör für Modus C
Modus C Station Übersicht
Anzeigebildschirm
LED
HALTERPLATTE STATION
SCHRAUBEN FÜR HALTER
ALLEN KEY
REFERENZPAPIER
30MM KUNSTSTOFFBOLZEN
HAKEN30MM SCHRAUBEN
An / Aus
Ladestecker
Spezifikation
Ladestation für Stufe 2 EV
Installaonsmethode: Wand / Pol Modus: C (mit Stecker) Zerfikat: TÜV, CE IP66 Spannungsbereich: 230V ± 10% Betriebsstrom: 16Amp Maximale Leistung: 11KW Phasenmodus: Einzelphase
Betriebstemperatur: -40°C 55°C
Schalenmaterial: ABS+PC Legierung Startmodus: Schalläche
(Standardeinstellung)
Bedienungsanleitung
1 2
Verteilerkasten
Wand
Sicherheitsschutz: Warn- und Anzeigefunkonen Kurzschlussschutz Schutz für Ausgangsüberstrom Eingang unter Spannungsschutz Übertemperaturschutz Bodenschutz Schutz für Eingangsüberspannung Erkennung des Ladezustandes
LADESTATION
Taste Halter
Ladestecker Haken
Stellen Sie sicher, dass die Wallbox an die Stromversorgung
angeschlossen ist
Verbinden Sie den EV und die Wallbox mit dem EV-Ladekabel
3
Drücken Sie die Taste auf der rechten Seite der Wallbox, um den Ladevorgang zu starten oder zu stoppen
Hängen Sie das Kabel an den Haken, wenn es nicht verwendet wird
Installationsanleitung
REFERENZPAPIER
für die Größe der
Befestigungsbohrung
Die Wand
Bohren Sie die Löcher gemäß dem REFERENZPAPIER
Befestigen Sie die
PLATTE
mit 30mm SCREWS
an der Wand
30mm KUNSTSTOFFBOLZEN
Mit STATION in die
Hämmern Sie die
in die Löcher
Nehmen Sie das
REFERENZPAPIER
von der Wand ab
an der Wand einbetten
PLATTE
Dies ist das letzte fertige Bild,
Sie können den Haken
und den Halter
an jedem beliebigen
Ort installieren
Das Kabel kann am
HAKEN und HALTER
aufgehängt werden
Entfernen Sie den
Schutzfilm
Wallbox-Übersicht
Accessories of Mode A
HAKEN
Modus A Station Übersicht
Anzeigebildschirm
LED
STECKDOSEPLATE STATION
30MM KUNSTSTOFFBOLZEN
SCHRAUBE SHIM
ALLEN KEY
REFERENZPAPIER
30MM SCHRAUBEN
30MM METALLSCHRAUBEN
95MM SCHRAUBEN
An / Aus
Steckdose
Spezifikation
Ladestation für Stufe 2 EV
Installaonsmethode: Wand / Pol Modus: A (mit Sockel) Zerfikat: TÜV, CE IP66 Spannungsbereich: 230V ± 10% Betriebsstrom: 16Amp Maximale Leistung: 11 KW Phasenmodus: Einzelphase Betriebstemperatur: -40°C ~+ 55°C Schalenmaterial: ABS+PC Legierung Startmodus: Schalläche
(Standardeinstellung)
Bedienungsanleitung
Distribution Box
Wand
Ladestation Taste
Halter Steckdose
Sicherheitsschutz: Warn- und Anzeigefunkonen Kurzschlussschutz Schutz für Ausgangsüberstrom Eingang unter Spannungsschutz Übertemperaturschutz Bodenschutz Schutz für Eingangsüberspannung Erkennung des Ladezustandes
Stellen Sie sicher, dass die Wallbox an die Stromversorgung angeschlossen ist
Drücken Sie die Taste auf der rechten Seite der Wallbox, um den Ladevorgang zu starten oder zu stoppen
Hängen Sie das Kabel an den Haken, wenn es nicht verwendet wird
Stecken Sie den Stecker in die Steckdose
Verbinden Sie den EV und die Wallbox mit dem EV-Ladekabel
Loading...