Morco 8100 Installation And Operating Instructions Manual

1
MORSØ JERNSTØBERI A/S . DK-7900 NYKØBING MORS
E-Mail: stoves@morsoe.com · Website: www.morsoe.com
A French version of the manual can be downloaded at www.morsona.com
Une version française du manuel peut être téléchargé à www.morsona.com
Installation and Operating Instructions
For use in North America
Read this entire manual before you install and use your new room heater. If this room heater is not properly installed, a house fire may result. To reduce the risk of fire, follow the installation instructions. Failure to follow instructions may result in property damage, bodily injury, or even death.
Contact local building officials about restrictions and installation/inspection-requirements in your area.
Save these instructions
2
We congratulate you on your choice of a Morsø stove. Morsø has been producing some of the world’s best stoves since 1853. If you follow this installation- and operating instruction carefully, we can assure you many years of warmth and pleasure.
Optional Accessories A wide range of accessories (such as handling gloves, fireside tools, glass cleaner and heatproof paint) are available for use with your Morsø stove. They help with day-to-day running and maintenance. Contact your Morsø dealer for more information.
The Morsø 8100 series meets the U.S. Environmental Protection Agency’s emission limits for wood heaters sold on or after July 1, 1990
The Morsø 8100 series have been tested by OMNI-Test Laboratories, Inc. The test standards are ANSI/UL-1482 for the United States and ULC S627 for Canada.
The stove is listed for burning wood only. Do not burn other fuels.
Under specific test conditions this heater has been shown to deliver heat at rates ranging from 10,900 to 25,400 Btu´s.
Cast iron Cast iron is a live material. There are no two ovens that are identical. This is partly due to the tolerances of the casting process, partly because the ovens are a work of craftsmanship. Minor unevennesses may also occur in the cast iron surface.
3
CONTENTS:
1.0 Installation of your Morsø stove 4
1.1 Checking loose parts in the stove 4
1.2 The chimney / flue system 5
1.3 Flue Connection 6
1.4 Connection to existing chimney 6
1.5 Positioning the stove 8
1.6 Mobile Home Installation 10
2.0 Operation 11
2.1 Before you start firing 11
2.2
Lighting and loading intervals 12
3.0 Maintenance 16
3.1 Exterior maintenance 16
3.2 Internal maintenance 16
3.3 Cleaning the stove and the flue 18
3.4 Leaving the stove for extended periods 21
3.5 Parts diagram 22
3.6 Parts list 23
4
Installation requirements vary in different districts, and the local building officials have the final authorization to approve your installation. You should discuss the installation with them before beginning. Please ask your dealer for further information.
Do not connect to any air distribution duct or system
.
Important: If the installation instructions are not followed carefully, it may cause dangerous situations like chimney - and house fires. Follow the instructions carefully and do not deviate from them as it may cause injuries to people or property.
1.0 Installation of your Morsø stove
Installation of woodburning stoves must be safe and legal.
If your Morsø stove is not installed correctly, it may cause a house fire. To reduce the risk of fire, the installation instructions must be followed carefully. Contact the local building officials about restrictions and installation inspection in your area.
Before you start installing your stove, make sure that:
- The stove and chimney connection are placed far enough from combustible materials to meet all clearance requirements.
- The floor protection must be adequate and must be made correctly according to ´the requirements. All neccessary approvals are needed from the local building officials.
The data plate, which is located on the back of the stove, provides information regarding safety testing information, name of certified testing laboratory, and installation requirements.
1.1 Checking loose parts in the stove
After unpacking, check that the fire bricks are firmly in position and have not shifted in transit. Check also that the air control works freely.
Before starting the initial fire, make sure that the baffle is placed correctly.
Standard Accessories
A Morsø glove and ceramic flue connection gasket are standard accessories that usually can be found in the ashpan or firebox area.
5
1.2 The chimney / flue system
Note that the flue system must be independently secured and must not rely on the stove for support.
The stove must not be connected to a chimney flue serving any other appliance. (Several flues may run up a single chimney stack; use one flueway per appliance).
Use a residential type masonry or listed type HT factory-built chimney.
High Temperature (H.T.) Chimney Standard UL-103-1985 (2100º F.) or a code-approved masonry chimney with flue liner for the USA, and High Temperature (650ºC) Standard ULC S-629 for Canada.
The internal dimensions of the chimney connector and chimney must not be less than 6 inches diameter (or equivalent cross section), and should not be significantly larger than this. Too large a section will tend to allow the flue gases to cool excessively, causing sluggishness or unpredictability in the stove’s performance.
We recommend the length of the chimney system should be at least 16 feet (not required) above the stove in normal domestic situations, measured from the flue collar to the top of the chimney. Local conditions like for example - roof constructions, large trees nearby and high altitude, may influence the chimney draft and height. Therefore, contact the local professional chimney sweep or your Morsø dealer.
Typical Factory-Built or Masonry Chimney Installations
6
1.4 Connection to the existing chimney
A chimney connector is the double-wall or single-wall pipe that connects the stove to the chim­ney. The chimney itself is the masonry or prefabricated structure that encloses the flue. Chim­ney connectors are used only to connect the stove to the chimney.
Double-wall connectors must be tested and listed for use with solid-fuel burning appliances. Single-wall connectors should be made of 24 gauge or heavier gauge steel. Do not use galvanized connector; it cannot withstand the high-temperatures that smoke and exhaust gases can reach, and may release toxic fumes under high heat. The connector must be 6 inches (150mm) in diameter.
If possible, do not pass the chimney connector through a combustible wall or ceiling.
If passage through a combustible wall is unavoidable, refer to the sections on Wall Pass- Throughs. Do not pass the connector through an attic, a closet or similar concealed space when installing the chimney connectors.
It is important to keep the flue gases moving smoothly in the right direction. Do not vent into a large void at this location; rather form one continuous section all the way up. Use mild bends (e.g. 45º vs. 90º) rather than sharp angles where a change of direction is required. All parts of the venting must be accessible for cleaning purposes. In horizontal runs of chimney, maintain a distance of 18 inches from the ceiling. Keep it as short and direct as possible, with no more than two 90 degree turns. Slope horizontal runs of connector upward 1/4 inch per foot (20 mm per metre) going from the stove toward the chimney. The recommended maximum length of a horizontal run is 3 feet (1 metre), and the total length should be no longer than 8 feet (2.5 metres). Information on assembling and installing connectors is provided by the manufacturer’s instructions exactly as you assemble the connector and attach it to the stove and chimney.
Be sure the installed stove and chimney connector are correct distances from near by combustible materials. See the clearance paragraph page 8.
1.3 Flue Connection
The stove is supplied from the factory with a round blanking plate blocking off the top and rear flue exit (behind the rear shield plate). A flue collar are placed in the firebox area.
Use a 24 MSG black or blue chimney connector or listed double wall chimney connector. Refer to local codes and the chimney manufacturer’s instructions for precautions required for passing a chimney through a combustible wall or ceiling. Remember to secure the chimney connector with a minimum of three screws to the product and to each adjoining section. The collar can be fitted to the rear outlet. Simply knock out the round panel on the rear heat shield plate to reveal the cast iron plate. Untwist the blanking plate and the flue collar and swap their positions. Re-secure by pushing down and tighten the enclosed screws. Position the stove and connect to the flue system.
Wear gloves and protective eyewear when drilling, cutting or joining sections of chimney connector
Where passage through a wall or partition of combustible construction is desired, the instal­lation shall conform to CAN/CSA-B365.
7
8
1.5 Positioning the stove
Distance to walls and lintel
When the stove is positioned near combustible materials, observe all current local and national building regulations with regards to clearances. Whatever regulations apply to your area, do not in any case install the stove within 8 inches of combustible materials around the sides or 16 inches above the top of the stove (fireplace installations require greater clearances above the stove - see below in the clearance chart). These distances may need to be increased if the materials are sensitive to heat. Note also that wall paper and other decorative materials may become detached with the effects of heat and care should be taken to ensure that they do not fall towards the stove in such an event. When the stove is positioned near non-combustible materials, a gap of 4 inches or more is recommended for cleaning purposes and to ensure that heat circulates around the stove and out into the room.
If using rear exit, the floor protection must extend beneath the chimney connector and 2-in beyond each side.
CLEARANCE REQUIREMENTS STANDARD RESIDENTIAL INSTALLATION
SINGLEWALL CONNECTOR
USA CANADA
A. B. C. D. E. F. G. H.
10’’
6’’
6’’ 17’’ 11’’ 13’’
43,5’’
84’’
254 mm. 152 mm. 152 mm. 432 mm. 279 mm.
330 mm. 1105 mm. 2134 mm.
SIDEWALL TO UNIT BACKWALL TO UNIT CORNERWALL TO UNIT SIDEWALL TO CONNECTOR BACKWALL TO CONNECTOR CORNERWALL TO CONNECTOR UNIT TO CEILING FLOOR TO CEILING
CLEARANCE REQUIREMENTS STANDARD RESIDENTIAL INSTALLATION
DOUBLEWALL CONNECTOR
USA CANADA
A. B. C. D. E. F. G. H.
10’’
2’’
3,5’’
17’’
7’’ 10,5’’ 43,5’’
84’’
254 mm.
51 mm.
89 mm. 432 mm. 178 mm. 267 mm.
1105 mm. 2134 mm.
SIDEWALL TO UNIT BACKWALL TO UNIT CORNERWALL TO UNIT SIDEWALL TO CONNECTOR BACKWALL TO CONNECTOR CORNERWALL TO CONNECTOR UNIT TO CEILING FLOOR TO CEILING
9
CLEARANCES IN ( ) IN MM FOR CANADA FOR NON­COMBUSTIBLE FLOOR PROTECTOR
CLEARANCE REQUIREMENTS STANDARD RESIDENTIAL INSTALLATION
REAR VENT OUT BACK WALL
SINGLEWALL CONNECTOR
USA CANADA
A. B. C. D. E. F. G. H.
9,5’’
6’’
-
17’’
-
-
-
-
241 mm. 152 mm.
-
432 mm.
-
-
-
SIDEWALL TO UNIT BACKWALL TO UNIT CORNERWALL TO UNI SIDEWALL TO CONNECTOR BACKWALL TO CONNECTOR CORNERWALL TO CONNECTOR UNIT TO CEILING FLOOR TO CEILING
CLEARANCE REQUIREMENTS ALCOVE INSTALLATION
SINGLEWALL CONNECTOR
USA CANADA
A. B. C. D. E. F. G. H.
10,5’’
8’’
­18’’ 13’’
-
36,5’
77’’
267 mm. 203 mm.
­457 mm. 330 mm.
­927 mm.
1956 mm.
SIDEWALL TO UNIT BACKWALL TO UNIT CORNERWALL TO UNI SIDEWALL TO CONNECTOR BACKWALL TO CONNECTOR CORNERWALL TO CONNECTOR UNIT TO CEILING FLOOR TO CEILING
CLEARANCE REQUIREMENTS ALCOVE INSTALLATION
DOUBLEWALL CONNECTOR
USA CANADA
A. B. C. D. E. F. G. H.
10,5’’
5’’
-
18’
10’’
-
36,5’’
77’’
267 mm. 127 mm.
­457 mm. 254 mm.
­927 mm.
1956 mm.
SIDEWALL TO UNIT BACKWALL TO UNIT CORNERWALL TO UNI SIDEWALL TO CONNECTOR BACKWALL TO CONNECTOR CORNERWALL TO CONNECTOR UNIT TO CEILING FLOOR TO CEILING
10
Distance to furniture
The recommended minimum distance from stove to furniture is 30 inches. Note that some furniture is more easily affected by heat and may need to be moved to a greater distance. This is your responsibility.
In addition other combustible materials, away from the stove. In general, a distance of 30 inches must be maintained between the stove and moveable combustible item such as drying clothes, newspapers, firewood etc.
1.6 Mobile Home Installation
The Morsø 8100 can be installed in a mobile home if equipped with an outside combustion air kit, a terminal cap with a spark arrestor, and if it meets the following installation requirements:
The stove must be secured to the mobile home structure by bolting through the hearth pad and into flooring.
The stove must be installed with a listed Type HT chimney connector, HT Chimney, and terminal cap with spark arrestor. Never use a single wall connector (stovepipe) in a mobile home installation.
Floor protection requirements in section 1.5 must be followed precisely.
In Canada, this appliance must be connected to a 6” (152 mm) factory-built chimney conforming to CAN/ULC-629M, STANDARD FOR FACTORY BUILT CHIMNEYS. Floor protection as referenced in section 1.5 must be followed, as well as use of Canadian Floor Protector.
Follow the chimney and chimney connector manufacturer’s instructions when in­stalling the flue system for use in a mobile home.
Outside air kit should be installed according to installation guide in the kit.
Intake air piping can be installed through the floor into a vented crawl space or through the wall of the residence to obtain outside air.
Install in accordance with 24 CFR, Part 3280 (HUD).
NOTE: Top sections of chimney must be removable to allow maximum clearance of
13.5’ from ground level for transportation purposes.
WARNING: NEVER DRAW COMBUSTION AIR FROM A WALL, FLOOR OR CEILING CAVITY OR FROM ANY ENCLOSED SPACE SUCH AS AN ATTIC OR GARAGE. DO NOT INSTALL IN SLEEPING ROOM.
Rotatable smoke outlet
The rotatable smoke outlet is locked during transportation. The screw that locks the smoke outlet is located next to the little yellow label on the edge of the cast smoke outlet, and can be loosened with a 2 mm Allen key.
N.B.: The smoke outlet must not be lifted when the screw that locks the rotatable smoke outlet has been loosened. If you lift the smoke outlet, the steel balls on which it turns may fall out.
11
2.0 Operation
2.1 Before you start firing
For Use with Solid Wood Fuel Only. Do Not Overfire, If Heater or Chimney Connector Glows You Are Overfiring. Inspect and Clean Chimney Frequently. Under Certain Conditions of use creosote buildup may occur rapidly. Because of risk of smoke and flame spillage, operate only with door fully closed. Caution: Hot while in operation. Keep children, clothing and furniture away. Contact may cause skin burns. Do not use chemicals or fluids to start the fire. Do not burn garbage or flammable fluids. Do not use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter or fluid or similar liquids to start or freshen up a fire in this heater. Keep all such liquids away from the heater
while it is in use.
CAUTION: THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL, AND CEILING/ROOF MUST BE MAINTAINED (I.E., DO NOT CUT THROUGH FLOOR JOIST, WALL STUD, CEILING TRUSS, ETC.) DO NOT USE A GRATE TO ELEVATE FIRE - BUILD FIRE DIRECTLY ON HEARTH.
Note:
Acid Protection
If acid-washing the masonry around the stove, protect the stove surface with an acid-proof cover
Fresh Air Inlet
Unless there is deemed to be sufficient ambient leakage of air into the room via doorways, windows and the like, a dedicated fresh air inlet will be needed. This inlet should have 2 square inches (1250 square mm) of free air space. This is particularly important where the room is well sealed, or where an extractor hood or ventilation system disturbs the natural air pressure. Such an inlet should not be on a wall that is usually subject to negative pressure from normal wind pattern. Avoid placing the inlet directly across the room from the stove, thus causing a cold air draft.
12
The secondary air is injected into the flue gases above the fire resulting in a cleaner, more efficient combustion process. The supply of secondary air and Pilot air is fixed open and is not adjustable. For extra safety, your stove should be with a removable handle.
2.2 Lighting and loading intervals
When first lighting the stove, a large volume of air is needed. When the stove is cold, you should leave the door open an inch or two for the first few minutes and open the primary air supply completely. While the door is open, do not leave the stove unattended.
To form a reasonable bed of ash on the floor of the stove, you should use 2-4 pounds of dry kindling at the initial lighting. If possible, maintain a 1-1.5 inch (2-3 cm) layer of ash on the floor of the combustion chamber for added insulation.
Caution: Do not place fuel within the installation clearances for the stove or within the space required for loading fuel and ash removal.
Starting the First Fire The initial fire should be small, so that the stove paint can cure and the main plates of the stove can settle into position. Some fumes will be given off by the paint. Ventilate the room during this phase. The setting of the air control, lighting techniques and loading intervals will depend on chimney draft, the fuel used, the heat required and so on. Some basic techniques are outlined below.
In principle
Your stove should be with Primary and Secondary air and Pilot air inlets. Primary Air is controlled using the lever situated over the door. Moving the control lever to right position will open the air inlet and will allow a supply of preheated air to enter the firebox via the ‘airwash’ system situated inside the stove and above the glass.
Choosing your fuel
All types of natural wood can be burned on your stove, but they must be well-seasoned and dry. Once the wood is cut to length, it should be split down middle - to suit the dimensions given below - to allow moisture to evaporate.
Cut the wood to a length of max 12 inches (30 cm) and approx. 3 to 3.5 inches (7-8 cm) in section. If you can weigh your wood, aim for around 2 lbs. For correct combustion and heat output, wood fuel should contain no more than 20% moisture; this can easily be checked by using the Morsø Moisture Meter (part # 62929900)
To naturally season wood fuel, stack and store it under cover in an airy location where fresh air can move through each piece. Some soft woods may take as little as one good summer to season whereas harder woods such as oak, maple, and elm may require seasoning up to 18 months. Avoid overly dry wood that is gray in color as under certain conditions it can cause performance problems, such as back-puffing and sluggishness. Well seasoned wood will be light to hold and will show signs of cracking from the center-out in the ends. If your wood spits or sizzles when burnt, and your stove’s door glass persistently mists up, your wood is not properly seasoned. Never use drift wood (from the sea), whose salt content may cause corrosion, nor construction wood that may have been impregnated with chemicals.
13
Step-by-step procedure
1. The air supply must be fully open.
3. Light the fire. An ember bed will quickly be formed by lighting with firestarters, Morsø kindling bags or 7-10 pieces of twisted paper under the dry kindling wood.
4. After lighting, partially close the door, leaving it open an inch or two to allow in plenty of combustion air.
2. For lighting the fire use 2-4 pounds of dry kindling wood.
14
5. When the chimney is warm after about 5-10 minutes, the door should be closed. A suitable layer of ember will be formed after about 15-20 minutes.
6. When ready to reload, use a poker to spread the embers across the firebox floor, bringing plenty towards the front of the stove.
7. Lay three pieces of wood onto the embers. Leave half an inch or more between each piece.
Max. fuelload 1,2 pounds/h.
8. Close the door. Leave the primary air supply fully open.
If it does not light, leave the door slightly
ajar to allow the necessary amount of air in to ignite the wood.
Close the door again once the wood has
kindled.
9. After a few minutes, adjust the primary air supply to suit your heating requirements.
Make sure that there is always enough air
to sustain clear, enduring flames when you reduce the amount of combustion air, and afterwards.
15
Do not for any reason attempt to increase the firing of your heater by altering the air
control adjustment range outlined in these directions.
Warning: Fireplace stoves must never be left unattended with the door open.
If the door is left partly open, gas and flame may be drawn out of the fireplace stove
opening, creating risks from both fire and smoke. We recommend that you fit a smoke detector in the room where the stove is installed.
DO NOT OVERFIRE THIS HEATER. Overfiring may cause a house fire, or can result in permanent damage to the stove. If any part of the stove glows, you are overfiring.
The maximum recommended weight of wood fuel per load is 2.5 kg/h/5.5Ibs (approx 3 split logs).
Under normal firing, the average flue temperature in the stove pipe, measured 20 cm above the stove, is approx. 300° C (550°F). The maximum flue temperature in the stove pipe must not exceed 450° C (750°F). If the flue temperature exceeds 450°C (750°F), it is considered as over firing and may cause premature wear and tear of the stove.
To help gauge the correct running temperature of your stove, we recommend you use the Morsø Flue Gas Thermometer (part # 62901200). The Flue Gas Thermometer magnetically attaches onto the stove pipe approx 20 cm (8”) above the stove’s top plate and measures the surface temperature of the stove pipe. Please see your authorized Morsø Dealer for availability.
Draft conditions
If smoke or fumes come out of your stove when lightning up and reloading, or if the fire simply will not respond, a poor draft is almost certainly to blame. (In a very few cases, there may be insufficient fresh air getting into the room - see installation advice above). Take advice from your stove supplier on how best to upgrade your flue system to improve draft.
10. For refueling, add a layer of wood while there are still plenty of live embers, repeat steps 6-9.
16
3.0 MAINTENANCE
When perfoming maintenance on your stove, always protect yourself, using safety goggles and gloves.
3.1 Exterior Maintenance
The stove surface is painted with heat-resistant Senotherm paint. It is best kept clean by vacuuming with a soft brush attachment or by wiping with a lint-free cloth. Over a period of time, the painted surface may become slightly grey. A can of Morsø touch-up spray paint should be available from your stove supplier. This can be applied - in accordance with the instructions - in just a few minutes. When first firing after touching up, the stove will give off a slight smell as the paint cures. Make sure to ventilate the room well during this phase.
3.2 Internal maintenance
Glass
If the stove is generally run at the correct temperatures, there should be little or no dirt on the glass. If dirt does settle during lighting, most will burn off as temperatures increase.For heavier deposits that will not burn off, use morsø glass cleaner, applied when the glass is cold, in accordance with the instructions. Never use abrasive cleaners on the glass surface.
Reasons for dirty glass
· Fuel too wet
· Logs too large or not split
· Combustion temperatures too low
Replace broken glass immediately. Do not operate your stove if the glass in the door is damaged.
If you need to replace the glass, it should be replaced with the high temperature ceramic class supplied by Morsø, contact your Morsø dealer.
Installing the glass
Never install the glass when the stove is in function.
Rules of woodburning If you want less heat, put fewer logs on the stove and reduce the amount of air. It is still important to maintain a good layer of embers. Less heat - less wood - less air Greater heat - more wood - more air Soot deposits will settle on the glass if the stove is run too slowly or if your wood is not well seasoned.
We would strongly recommend that you do not leave your stove alit at night. It harms the envi­ronment, and constitutes very poor use of the wood, as the gases in the wood do not ignite at the low temperature, but settle as soot (unburned gases) in the chimney and stove instead.
17
To reduce the risk of breaking the glass, avoid striking the glass or slamming the door.
Internal service parts The flame-path equipment - consisting of the ashpan, grate, firebricks, Cast iron fire plates, glass, baffle and flue collar - are subject to the extremes of heat produced by the fire. From time to time, one or other of these parts may need replacing as a matter of routine maintenance.
Ceramic glass replacement
Ceramic glass cannot be recycled because it has a higher melting point that ordinary glass. If ceramic glass is mixed with ordinary glass, the raw material is spoiled, and the reclaiming process may be halted. Take care that the ovenproof glass does not end up among ordinary recycled waste. That will be a great benefit to the environment. Note: Should be han- ded in to a recycling sta­tion as ceramic glass.
1. When you open the door, you will find two small M4 unbraco screws, one in each hinge. Unscrew
the two screws, lift the door off the hinges and place it face down on a sheet of cardboard or other nonabrasive fabric.
2. Unscrew the 4 bolts that secure the glass. (In the event that a bolt sheers off when being
unscrewed, remove the remaining body of the bolt by drilling down its centre with 1/8 inch high speed steel drill bit. Smaller drill bits may be successful, but do not use a lager bit. Make sure the bit stays away from the edges of the bolt - this may damage the thread in the cast iron).
3. Remove the old ceramic gaskets and clean up the surface underneath with wire wool or emery
paper to remove loose particles.
4. Place the new gasket material in position around the perimeter of the window area, making
sure to pinch them to the length in such a way that they make a continuous seal. Leave no gaps.
5. Place the new glass in position on the strips and screw home the fresh bolts and fitting by hand.
6. Finally, give each of the bolts an extra half turn or so. The glass should held tight enough by that
cleaning will not dislodge it. Do not over-tighten the bolts as this may put excessive pressure on the glass, resulting in cracking - important!
18
Dispose the ash in a metal container with a tight fitting lid.
The closed container of ashes should be placed on a noncombustible floor or on the ground, well away from all combustible materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally disperded, they should be retained in the closed container until all cinders have thoroughly cooled.
Return the ash pan to its original position in the stove, and close the door.
Clean the flue/chimney - all the way from the stove to the flue terminal point above the house.
A good routine is to clean the flue after each heating season in any case, and inspect prior to the season to ensure that bird’s nests or other blockages have not occurred during the off season.
Ash disposal
Empty the ashpan on a daily basis or as needed. Ash allowed to build up towards the underside of the grate will trap heat and could cause premature failure of the grate.
Empty the ashpan according to this procedure:
Open the front door, and use a shovel or poker to stir excess ash through the ash slots in the grate down into the ash pan. Take out the ash pan, making sure to keep it level to avoid spilling ash.
3.3 Cleaning the Stove and the Flue
Check for soot above the baffle plate and around the flue outlet every month or so to start with. If the stove suddenly becomes sluggish, check for a soot fall around the flue collar or in the flue/ chimney.
Gasket
The gasket around the perimeter of the door may harden over a period of time. It should be replaced if it becomes difficult to close the doors or if air starts to leak in around the perimeter of the doors, causing the fire to become a little less controllable. A morsø rope gasket kit is available from your stove supplier.
The chimney and chimney connector should be inspected at least once every two months during the heating season to determine if a creosote buildup has occurred. If creosote has accumulated, it should be removed to reduce the risk of a chimney fire.
NOTE: The flame-path equipment, the ceramic rope and the paint finish are not covered by guarantee.
All of these service parts can be bought from your morsø dealer, and we recommend that damaged parts are replaced as soon as possible to avoid collateral damage. Should the baffle be distorted by an overfire, the stove will still function, although its efficiency may be compromised. Replace it as soon as possible.
Reasons for fast internal wear and tear
Persistent heavy firing Soot and ashes left to accumulate
19
Caution:
Never empty a stove in operation. Never use your household or shop vacuum cleaner to remove ash from the stove; always remove and dispose of the ash properly.
Creosote - formation and need for removal
When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a slow-burning fire. As a result, creosote residue accumulates on the flue lining. When ignited this creosote makes an extremely hot fire. When burning wood, the chimney and chimney connector
should be inspected at least once every two months during the heating season to determine if a creosote buildup has occurred. If creosote has accumulated, it should be removed to reduce
the risk of a chimney fire.
Chimney sweeping
Inspect the system regularly during the heating season as part of a regular maintenance schedule. To inspect the chimney, let the stove cool completely. Then, using a mirror, sight up through the flue collar into the chimney flue. If you cannot inspect the flue system in this fashion, the stove must be disconnected to provide better viewing access. Clean the chimney using a brush the same size and shape as the flue liner. Run the brush up and down the liner, causing any deposits to fall to the bottom of the chimney where they can be removed through the clean-out door. Clean the chimney connector disconnecting the sections, taking them outside, and removing any deposits with a stiff wire brush. Reinstall the connector sections after cleaning, being sure to secure the joints between individual sections with sheet metal screws. If you cannot inspect or clean the chimney yourself, contact your local Morsø Dealer or a professional chimney sweep.
If you do experience a chimney fire, act promptly and:
Close the air control. Get everyone out of the house. Call the Fire Department.
Annual maintenance
Before the heating season, perform a thorough cleaning, inspection and repair: Thoroughly clean the chimney and chimney connector. Inspect the chimney for damage and deterioration. Replace weak sections of prefabricated chimney. Have a mason make repairs to a masonry chimney. Inspect the chimney connector and replace any damaged sections. Check gasketing for wear or compression, and replace if necessary. Check the glass for cracking; replace if needed. Check door and handle for tightness. Adjust if needed.
How to clean the inside parts of Morsø 8100
When cleaning the inside parts of the stove in connection with the annual visits from your local chimney sweep we recommend that you remove the inside parts from the fire chamber. Please be careful as the vermiculite parts are porous. Cleaning of the stove must be done when the stove is cold.
20
2. Tip the side bricks and remove them from the fire chamber.
3. Tip the other side brick and remove it from the fire chamber.
4 When the side bricks are removed the
bottom baffle is lowered and lifted out of the fire chamber.
1. The bottom baffle is lifted up a bit and held in that position. Loosen the side bricks.
21
3.4 Leaving the stove for extended periods
Important:
If the stove is to be left unused for any period of time, clean it out thoroughly and leave the air control slightly open to allow airflow. Make sure that the flue does not allow rainwater to come anywhere near the stove; install a chimney cap, but do not block off the flue completely. These measures should ensure there is a slight movement of air through the stove, and that the body of the stove remains dry, right into the corners. Any ash left within an unfired stove can attract moisture like blotting paper. If moisture is allowed to settle within the stove, rust will form. Rust expands as it takes a grip. This can lead to undue pressure on the stove joints, and this in turn may result in damage to the stove.
NOTE: It is best to thoroughly clean the stove after the heating season has concluded. Adding a dessicant, such as kitter litter, into the ash pan helps absorb moisture during the summer months. Be sure to remove this prior to the heating season.
We hope you have many years of carefree warmth in its company. Some initial experimentation with loading and running techniques will decide your normal routine. If you have any problems after this short learning phase, please refer to your stove dealer. Should they be unable to help for any reason, please contact us in writing at the address on the front of this publication.
5. The upper baffle is removed from the brackets and lifted out of the firechamber.
22
3.5 Parts diagram for model Morsø 8100
23
3.6 Parts list for model Morsø 8100
Posnr. Parts: 8140 NA 8142 NA 8141 NA 8147 NA 8148 NA 8150 NA 8151 NA W. drawer incl. turnable Pedistal incl. Pedistal Soapstone Soapstone base 90° turneble base 90° 64810621 64810721 64811021 64811121 64811221 64810821 64810921 1 Top plate, outside 448110xx 448110xx 448110xx 448110xx 448110xx % % 2 Top frame 448107xx 448107xx 448107xx 448107xx 448107xx % % 3 socle, high 448111xx % 448111xx % % % % 4 Front frame 448131xx 448131xx 448131xx 448131xx 448131xx 448131xx 448131xx 5 Door 448103xx 448103xx 448103xx 448103xx 448103xx 448103xx 448103xx 6 Side plate, right 44810400 44810400 44810400 44810400 44810400 44813300 44813300 7 Side plate, left 44812300 44812300 44812300 44812300 44812300 44813400 44813400 8 Rear plate, inside 44810500 44810500 44810500 44810500 44810500 44812600 44812600 9 Base plate, inside 44812200 44810100 44812200 44812200 44812200 44812200 44812900 10 Top plate, inside 44810600 44810600 44810600 44810600 44810600 44810600 44810600 11 Side plate, outside 448108xx 448108xx 448108xx 448108xx 448108xx % % 12 Rear plate, outside 448109xx 448109xx 448109xx 448109xx 448109xx % % 13 Intermediate frame 34811300 34811300 34811300 34811300 34811300 34811300 34811300 14 Brick, back 79810200 79810200 79810200 79810200 79810200 79810200 79810200 15 Brick, side, right 79810300 79810300 79810300 79810300 79810300 79810300 79810300 16 Brick, side, left 79810400 79810400 79810400 79810400 79810400 79810400 79810400 17 Flue collar 443441xx 443441xx % % 443441xx 443441xx 443441xx 19 Stop bar 544541 544541 % % 544541 544541 544541 20 Screw 731630 731630 731630 731630 731630 731630 731630 21 Ceramic glass 79810100 79810100 79810100 79810100 79810100 79810100 79810100 22 Cover 442610xx 442610xx 442610xx 442610xx 442610xx 442610xx 442610xx 23 Flat bar 545006 545006 545006 545006 545006 545006 545006 24 Distance tube 545007 545007 545007 545007 545007 545007 545007 25 Screw 731620 731620 731620 731620 731620 731620 731620 26 Screw 791835 791835 791835 791835 791835 % % 27 Air canal, rear 44811600 44811600 44811600 44811600 44811600 44811600 44811600 28 Air adaptor 44142600 44142600 % % 44142600 44142600 44142600 29 Air canal, top 448117xx 448117xx 448117xx 448117xx 448117xx 348117xx 348117xx 30 Washer 791891 791891 791891 791891 791891 791891 791891 31 Screw % 731625 % % % % % 32 Screw 731608 731608 % % 731608 % % 33 Glass fitting 71814561 71814561 71814561 71814561 71814561 71814561 71814561 34 Screw 742508 742508 742508 742508 742508 742508 742508 35 Riddling grate 44182800 44182800 44182800 44182800 44182800 44182800 44182800 36 Sek. draught control 71814400 71814400 71814400 71814400 71814400 71814400 71814400 37 Handle f. draught control 71810761 71810761 71810761 71810761 71810761 71813561 71813561 38 Screw 73851000 73851000 73851000 73851000 73851000 73851000 73851000 39 Closing plate 71810600 71810600 71810600 71810600 71810600 71810600 71810600 40 Air canal, front 44811500 44811500 44811500 44811500 44811500 44811500 44811500 41 Tertiary box 71810861 71810861 71810861 71810861 71810861 71810861 71810861 42 Baffle plate, bottom 79810500 79810500 79810500 79810500 79810500 79810500 79810500 43 Cover 448120xx 448120xx % % 448120xx % % 44 Baffle plate, top 79810600 79810600 79810600 79810600 79810600 79810600 79810600 45 Distance tube 71810300 71810300 71810300 71810300 71810300 71810300 71810300 46 Distance tube 71810200 71810200 71810200 71810200 71810200 71810200 71810200 47 Screw 74162000 74162000 74162000 74162000 74162000 74162000 74162000 48 Screw 731635 731635 731635 731635 731635 731635 731635 49 Fitting plate 71811161 71811161 71811161 71811161 71811161 71811161 71811161 51 Screw 731612 731612 731612 731612 731612 731612 731612 52 Riddling bar 53001500 53001500 53001500 53001500 53001500 53001500 53001500 53 Bush 752621 752621 752621 752621 752621 752621 752621 54 Knob f. riddling bar 752619 752619 752619 752619 752619 752619 752619 55 Ash tray 71811300 71811300 71811300 71811300 71811300 71811300 71811300 58 Bush 71813061 71813061 71813061 71813061 71813061 71813061 71813061 59 Hinge pin 54819900 54819900 54819900 54819900 54819900 54819900 54819900 60 Screw 739606 739606 739606 739606 739606 739606 739606 62 Washer 746106 746106 746106 746106 746106 746106 746106 63 Handle 54812800 54812800 54812800 54812800 54812800 54812800 54812800 64 Fitting f. closing plate 71813300 71813300 71813300 71813300 71813300 71813300 71813300 65 Hinge pin 74701000 74701000 74701000 74701000 74701000 74701000 74701000 66 Hinge pin 71810100 71810100 71810100 71810100 71810100 71810100 71810100 67 Screw 73851100 73851100 73851100 73851100 73851100 73851100 73851100 68 Screw 74361000 74361000 74361000 74361000 74361000 74361000 74361000 69 Radiant shielding, bottom 71810400 71810400 % % % 71810400 %
24
Morsø jernstøberi A/S -20.05.2015 - 72810700
Posnr. Parts: 8140 NA 8142 NA 8141 NA 8147 NA 8148 NA 8150 NA 8151 NA W. drawer incl. turnable Pedistal incl. Pedistal Soapstone Soapstone base 90° turneble base 90° 70 Distance tube 542641 541439 % % % 542641 % 72 Radiant shielding, rear 71811400 71811400 71811400 71811400 71811400 71811400 71811400 73 Distance tube 541439 541439 541439 541439 541439 541439 541439 74 Screw 731616 731616 731616 731616 731616 731616 731616 75 Stop fitting, left 71711200 71711200 71711200 71711200 71711200 71711200 71711200 76 Stop fitting, right 71711300 71711300 71711300 71711300 71711300 71711300 71711300 77 Fitting f. cover 71813200 71813200 % % 71813200 % % 78 Round plate 545010 545010 545010 545010 545010 % % 82 Screw 731645 731620 % % % 731620 % 83 Bottom pl., outside socle % 448112xx % % % % % 84 Bottom pl., outside socle % 448127xx % % % % % 85 Leg % 448118xx % % % % % 86 Cover plate, rear, for leg % 348121xx % % % % % 87 Rubber stop block % 79082007 % % % 79082007 % 88 Screw % 742612 % % % 742612 % 89 Drawer, front % 448119xx % % % 448119xx % 90 Drawer, box % 548127xx % % % 548127xx % 91 Cover pl. f. drawer section % 718126xx % % % 718126xx % 92 Mounting pl., drawer sec. % 718128xx % % % 718128xx % 93 Ball barrel % 79082006 % % % 79082006 % 94 Screw % 73860800 % % % 73860800 % 95 Tubular rivet % 74700300 % % % 74700300 % 105 Tightening tape 79074200 79074200 79074200 79074200 79074200 79074200 79074200 106 Screw 73951600 73951600 73951600 73951600 73951600 73951600 73951600 107 Washer 736106 736106 736106 736106 736106 736106 736106 108 Screw 731650 731650 731650 731650 731650 731650 731650 109 Cover plug % % % % 79168300 % % 114 Screw 743625 743625 % % 743625 743625 743625 115 Lug for airtight flue kit 542642 542642 % % 542642 542642 542642 116 Screw 73861400 73861400 % % 73861400 73861400 73861400 117 Flue front grate 71814361 71814361 71814361 71814361 71814361 71814361 71814361 118 Screw 73861100 73861100 73861100 73861100 73861100 73861100 73861100 119 Pedestal % % 718147xx 548146xx 548146xx % % 120 Turnable base - complete % % 548104xx 548104xx % % % 121 Outside Base 8147 % % % 448132xx 448132xx % % 122 Soapst. top f. rear flue exit % % % % % 79811139 79811139 123 Soapst. top f. top flue exit % % % % % 79810739 79810739 124 Soapstone Side 8150 % % % % % 79810839 79810939 125 Dowel % % % % % 54455200 54455200 126 Rear Steel Plate 8150 % % % % % 548136XX 548139XX 127 Straps for soapst. stove % % % % % 71813800 71813800 128 Fittings f.lower st. back pl. % % % % % 71812400 71812400 129 Washer % % % % % 79189300 79189300 130 Steel base for 8150 % % % % % 71812000 % 131 Bottom pl., outside socle % % % % % 44812700 % 132 Screw % % % % % 74162000 % 133 Screw % % % % % 731625 % 134 Screw % % % % % 731612 % 135 Screw % % % % % 731610 731610 137 Soapstone Socle % % % % % % 79811639 138 Screw % % % % % 74162000 74162000 139 Screw % % 731635 731640 731640 % % 140 Rotatable flue collar % % 54810500 54810500 % % % 141 Adaptor rotat. flue collar % % 71814800 71814800 % % % 142 Stop bar % % 544541 544541 % % % 143 Screw % % 73962000 73962000 % % % 144 Screw % % 743625 743625 % % % 145 Screw % % 746106 746106 % % % 146 Flue adap. f. rotat. stove % % 548149xx 548149xx % % % 154 Screw % % % 73965000 73965000 % % 155 Lug Nut % % % 73500602 73500602 % % 156 Steel Box Nut % % % 735006 735006 % % 173 Dowel % % % % % % 71815000
Drawer front w. box % 548101xx % % % 548101xx % Drawer pull complete % 54810200 % % % 54810200 % Door complete 548103xx 548103xx 548103xx 548103xx 548103xx 548103xx 548103xx