easy reach during the entire life of the cooktop. Please carefully read this manual and all the instructions
contained herein before using the appliance. Keep any spare parts supplied with the appliance.
Installation and all gas/electric connections must be carried out by a qualified technician in accordance
with the manufacturer's instructions and in full compliance with current laws and safety regulations.
This appliance is intended solely for domestic use and is designed for the following functions:
cooking and reheating food. Any other use is considered as improper.
The manufacturer declines all liability resulting from poor installation, tampering,
inexpert use and use for purposes other than those specifically stated.
Check that the appliance has not been damaged during transport; Keep all packaging materials
(plastic bags, polystyrene foam, nylon, etc.) away from children, as they are potentially dangerous.
The packaging material is recyclable, and marked with the recycling symbol
Dispose of the appliance responsibly
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance
Electrical safety can only be guaranteed if the product is connected to a suitable earth connection.
After using the cooktop, ensure the indicator on the knob is turned to the "off" position.
Should you decide not to use the appliance any longer, before scrapping it make it unusable in accordance
accordance with current environmental health and safety laws, ensuring any parts which might
constitute a danger to children are rendered harmless.
Warning: in case of disassembly, maintenance and cleaning of the appliance, be careful
Please use suitable prevention and protection equipment
The label with technical specifications is placed under the bottom and in the manual. Do not remove it.
Never place inflammable object on the hob.
When a cooking zone is turned off, it remains hot for a while. During this time avoid touching the hot zone.
Do not use aluminium foil or plastic containers (the protective films are not suitable for this hob)
If there is a drawer under the hob, it is advisable not to keep inflammable objects or spray cans in it.
The power supply cable must never touch hot cooking zones, it might get damaged.
The cooking zone and pan bottom must always be dry and clean.
If you find cracks on the appliance; if the cooking zones are overheated; if the display or the knobs does
not work or if the hob turn-off by itself: immediately turn-off the appliance and call the assistance service.
In case of any malfunction, do not attempt to repair the hob by yourself, but contact the assistance service
Do not cook with empty pan, especially if it is an enamelled or aluminium pan.
Pan bottoms and ceramic glass could be damaged. Use only stainless steel pots and pans
Never place hot pans, frying pans, hard or poinjted objects on the control panel, knobs area or the frame
Sugar and other food with high sugar content will damage the hob. Any spilt food must be removed
immediately with a scraper for glass. Warning !!! The optional scraper for glass has a sharp blade.
The following damages will not affect the correct functioning or the stability of the appliance:
The formation of gelatinous residues due to melted sugar or food with a high sugar content; Scratches
due to salt, sugar or sand grains or rough pan bottoms; metal colour from pan stands.
Only use warm water with a mild detergent. Do not use corrosive or abrasive products,
as they could damage the surfaces. Warning: a steam cleaner is not to be used to clean the appliance.
These instructions are valid only for those countries whose ID initials appear on the
data plate found on the instructions handbook and on the appliance.
This manual constitutes an integral part of the appliance. It must be kept intact and within
FIRE HAZARD!
Declaration of Conformity
This appliance is in compliance with the following European Directives:
93/68/CE : General regulations
2009/142/CE : Concerning gas appliances
CE Regulation n° 1935/2004: this appliance is suitable to come in contact with food products.
2006/95/CE : Concerning low tensions
89/336/CE : Electromagnetic compatibility
-
-
-
-
COOKTOP SPECIFICATIONS
Warnings:
This appliance is designed to be built into a housing unit.
The installation class is type 3 for gas and type Y for electric parts.
Housing units must be designed to withstand temperatures of up to 90°C or over.
For correct installation, refer to the relevant paragraph and reference drawings.
The use of a gas cooking appliance produces heat and humidity in the room in which it is
installed. Ensure the kitchen is well ventilated: keep natural ventilation openings open, or install
a mechanical ventilation device (extractor hood with exhaust duct). In the case of intensive or
prolonged use of the appliance it may be necessary to provide additional ventilation, for example,
by opening a window, or more efficient ventilation, for example by increasing the hood speed.
This handbook is valid for several types of cooktop.
Refer to the data plate on the back in order to identify the model that corresponds to your appliance.
These informations, together with the instructions and the illustrations in the following paragraphs
will show you the characteristics of your appliance.
An Example:
Legend:
Trade Mark
(1)
Corresponding model
(2)
Technical code
(3)
Customer code
(4)
Power inputs
(5)
Voltage and frequency data
(6)
Country of target market and gas details
(7)
Gas burners power
(8)
Gas burners consumptions
(9)
USING THE COOKTOP
Gas burners
The delivery of gas to the burners is controlled by the knobs shown in fig.2 that in turn control the taps.
The symbols, depending on the various versions, may be printed over or under the knobs.
By moving the indicator to coincide with the printed symbols, the following adjustment can be made:
Tap closed, no gas delivery
Maximum capacity, maximum gas delivery
Minimum capacity, minimum gas delivery
Burners ignition
These models are equipped with safety valves which automatically shut off the gas delivery
in the event the burner should, for any reason, go out. To relight the burner, turn the knob to
position "tap closed" and repeat the ignition procedure explained in the following paragraph:
For light one burner, turn the gas tap knob to the maximum
delivery position, then press and hold down it for about 4÷5 seconds.
Warnings:
Once the burner is light on, adjust the flame by turning the knob to obtain the desired intensity.
-
The setting must always be positioned between the maximum and minimum, and never
between the maximum setting and the off position.
If the burner is difficult to light on, or if the flame is tall or irregular, turn off immediately
.
Grids
Choosing the right burner
-
-
-
Fitting the appliance in the worktop
-
turning the knob to "off" position and call Assistance Service.
If the particular nature of the local gas supply makes it difficult to ignite the burners with the knob
-
turned to the maximum setting, repeat the operation without a pan in position and with the knob
turned to the minimum setting and without pan stands.
Warning: The ignition device must not be used for more than 15 seconds. If after this length of time the
-
burner does not light, or if it goes out again accidentally, wait 1 minute before trying to ignite it again
The panstand grids are designed to make the appliance easy and safe to use. Always check the
panstand grids are properly positioned before using the appliance. Furthermore, always check the
protective rubber feet are all present and correctly positioned.
Grid for small pots or pans (optional - Fig.1A)
This is placed on top of the auxiliary burner grid (the smallest one) when pots or pans of reduced
diameter are used, to avoid unbalancing.
Special "WOK" support grid (optional - Fig.1B)
This is placed on top of the triple crown burner when using a “WOK” (concave bottom pan).
In order to prevent serious malfunction of the burner, never use a wok without this special grid
and never use the wok grid for flat bottomed pans
The symbols stamped on the control panel (fig.2) near the knobs indicate which knob correspond
to which burner. To choose the most suitable burner, take into account the diameter of
the pan as well as the pan capacity (see table).
The diameter of the pan must be proportionate to the burner power in order to ensure high yield.
Pan diameter
Hob model
SR
A
R
Burners
Auxiliary
Semi-rapid
Rapid
all models
Ø minimum
60 mm (with
reducer)
160 mm200 mm
200 mm240 mm
Ø maximum
140 mm
VP670 - VP650
Ø minimum
60 mm (with
reducer)
160 mm
160 mm200 mm
Ø maximum
140 mm
frontØ180mm
rearØ200mm
TR
Triple-crown
INSTALLATION INSTRUCTIONS
Important!
These instructions are intended for qualified technicians.
The appliance must be installed correctly, in compliance with current laws.
Before carrying out any operation on the appliance, it must be disconnected from the electric supply.
The cooktop may be fitted into any worktop, as long as it is heat resistant (minimum temperature of 90°C)
The dimensions of the hole to be made in the worktop and the minimum distances between rear
and side walls and those above the appliance are shown in figure 4.
Isolation below (fig.6):
240 mm260 mm
160 mm200 mm
-
If the cooktop is installed without an oven below it, a separator panel must be placed between
-
-
-
-
the bottom of the cooktop and the housing below it, at a minimum distance of 10 mm.
If the cooktop is installed over an oven, place a separator panel at a minimum distance of 15mm
and follow the oven manufacturer's instructions, ensuring nonetheless sufficient aeration
as specified in fig.6.
In any event, the electrical connection of the two appliances must be carried out
separately,
It is advisable to use an oven equipped with an internal forced cooling system.
both for electrical safety and to facilitate removal.
Fixing the cooktop (fig.7):
To fix the cooktop in the housing, proceed as follows:
Position the special gasket supplied [C] along the outer perimeter of the worktop, following the
diagram shown in fig.4, so that the ends of the gasket meet exactly without overlapping.
Position the cooktop into the worktop, taking care to ensure it is placed exactly in the centre.
Fix the cooktop to the worktop using the special brackets supplied [A], as shown in fig.7.
Correct installation of the sealing gasket ensures complete protection against infiltration of liquids.
Installation area and removal of combustion fumes
The appliance must be installed and operated in suitable areas, and in compliance with current laws.
The installation technician must observe current laws governing ventilation and removal of combustion fumes
Please remind that the air required for combustion is 2m3/h per kW of power (gas) installed.
Installation area
In the room where the gas appliance is installed, there must be a sufficient natural air supply to
allow the gas to burn correctly (in conformity of currents laws).
The natural flow of air must take place through an opening made on an outside wall of the room
and having a working section of at least 100 cm2 (A). In the case of appliances without safety
valves, this opening must have a minimum working section of 200 cm2 (fig.8).
This opening must be made in such a way that it cannot be obstructed from inside or outside.
It should be positioned near floor level, preferably on the side opposite the fume exhaust devices.
If it is not possible to make the necessary openings, the air can be supplied from an adjacent, suitably
ventilated room, as long as this room is not a bedroom, a dangerous area or a lowpressure area.
Removal of combustion fumes
Combustion fumes produced by gas appliances must be removed by means of a hood connected
directly either to an exhaust duct or to the outside (fig.8).
If a hood cannot be installed, an electric extractor fan must be fitted to the outside wall or the window.
This electric extractor fan must have a sufficient capacity to guarantee a change of air of the
kitchen of at least 3-5 times its volume.
Components shown in fig.8:
A
Opening for air supply
C
Hood for exhaust removal of combustion fumes
E
Electric extractor fan for removal of combustion fumes
Connection to gas supply
Before installation, make sure the type and pressure of the local gas supply are compatible with the
cooktop settings.
To do this, check the data on the appliance data plate on the cooktop as well as on this handbook.
The gas connection must be carried out by a qualified technician in compliance with local current laws.
Electrical connection
-
-
-
-
If using metal hoses, ensure these do not come into contact with any movable parts and are at no
point crushed.
Carry out the connection in such a way as does not cause any stress whatsoever on the appliance.
The gas supply connector is threaded G½” (fig.12).
For ISO R7 connections, the gasket is not required.
For ISO R228 connections, the washer supplied must be fitted.
After connection operations, check for leaks using a soapy solution.
Before connecting the appliance to the electricity supply, check that the voltage corresponds to that on the
data plate and that the power supply cable is suitable for the appliance load also stated on the data place.
If the appliance is connected directly to the mains, fit an all-pole disconnect switch with minimum
contact gap of 3 mm, adequate for the appliance load and complying to regulations.
The plug used must support the power of work of the appliance.
Warnings:
Do not use reducers, adapters or switches for connection to the mains, since these
could overheat and cause burns.
Earth connection is required by law (fig.10).
The manufacturer declines all liability resulting from failure to observe this regulation.
If the power cable must be replaced, use a cable having identical characteristics to the original
supplied by the manufacturer, suitable for the load and temperature (type T90°C). This is available
from After-sales service. Furthermore, the end of the power cable to be connected to the appliance
must have the Yellow-Green earth conductor 20 mm longer than the other conductors.
The cable must support the load of the appliance.
Refer to the table below for the size of the power cable
Cooktop type
Only with gas burners
With electric plate(s) <= 1000W
Wire size
Ø0,75 mm
Ø0,75 mm
2
2
Should it be necessary to replace the supply cord,
connect the wire in accordance with the following colours/codes:
BLUE
BROWN
YELLOW-GREEN
Check wether there is a omnipolar switch available on the domestic line which is compliant with
current standards laws.
Otherwise, place a device easily reachable between the appliance and the electricity line.
If the cable result damaged, it must be quickly replaced with a new one by a qualified technician
or call the After-Sales service.
ADJUSTMENT TO DIFFERENT TYPES OF GAS
If a different type of gas from the one indicated on the rating plate is used, the injectors must be replaced.
If spare injectors are not supplied with the appliance, they are available from the After-sales service.
For the choice of replacement injectors, refer to the injectors table at the end of this booklet.
The injectors are identified by their diameter, which is expressed in hundredths of mm, stamped on
the body of the injector itself.
NEUTRAL (N)
LIVE (L)
EARTH ( - )
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.