mophie Powerstation go rugged AC Instruction Manual

powerstation® go rugged AC
OPERATING INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
Warning DANGER-CAUTION Read and understand all safety information before using this product. Failure to follow these instructions may result in electrical shock, explosion, re which may result in serious injuries, death or property damage.
N When used correctly, lithium- ion rechargeable batteries provide a safe and dependable source of portable
power. However, if they are misused or abused, this may result in leakage, burns, re or explosion, causing personal injury or damage to other devices.
N Misusing or incorrectly connecting the powerstation go rugged AC may cause electric shock to users and
damage equipment.
N Do not operate in explosive atmospheres such as in the presence of ammable liquids, gases or dust. N Remove jump start clamps from vehicle battery after jump starting vehicle. N Keep the powerstation go rugged AC dry and away from moisture and corrosive materials. The powerstation
go rugged AC should not be used near water or wet areas such as bathtubs, showers, bathrooms, sinks, swimming pools or basements.
N Do not expose the powerstation go rugged AC to moisture, water, rain, or snow. N Keep the powerstation go rugged AC away from heat sources, including open ames, radiators, stoves,
ovens, and any other devices that product heat.
N The lithium-ion rechargeable battery used in this charging device may present a risk of re or chemical
burn if mistreated. Do not expose to re or excessive temperature. Do not expose to heat above 212°F (100°C) or incinerate.
N In the unlikely event of leakage or explosion use sand or a chemical re extinguisher. N The powerstation go rugged AC may become warm under extended high power operation. Do not cover,
wrap, or otherwise restrict the powerstation go rugged AC during operation.
N Do not disassemble the powerstation go rugged AC. There are no user-serviceable parts inside. Incorrect
reassembly may result in shock or re hazard.
N Do not drop or subject to strong impacts. Do not operate the powerstation go rugged AC if it has received
a sharp blow, or has otherwise been damaged in any way.
N Do not puncture, crush or subject to mechanical shock. N Only charge the powerstation go rugged AC by the specied method with the specied charging adapter
provided with the unit.
N Do not use any non-mophie-branded accessories with the powerstation go rugged AC. Doing so may cause
electric shock to users and damage equipment.
N The powerstation go rugged AC, along with its accessories, are not toys and should be kept away from children. N Make sure the jumper cables are fully plugged into the jump start output before trying to jumpstart your vehicle. N Do not touch red (positive) and black (negative) jumper clamps together at any point. N Do not insert any foreign object into the ports or openings of the powerstation go rugged AC. N Do not clean the powerstation go rugged AC with harsh chemicals, soaps or detergents. Just wipe the case
with a soft cloth.
N Make sure the powerstation go rugged AC’s charging ports do not become contaminated with lint or other
debris. Use a canned-air type of product periodically to ensure that the port openings are clear.
N Batteries should be recycled or disposed of as per state and local guidelines. N Storage: -4°F – 158°F (-20°C – 70°C), Discharge: 14°F – 122°F (-10°C – 50°C), Charge: 32°F – 113°F (0°C – 45°C)
SAVE THESE INSTRUCTIONS
Charging your powerstation go rugged AC
IMPORTANT: Before using the powerstation go rugged AC for the rst time, fully charge it (so that pressing any button lights up all ve LEDS on the LED Battery Indicators).
314-00931-A
To charge the powerstation go rugged AC, use the provided Wall Charging Adapter, and plug the provided USB Type-C cable into the charging port. Next, connect the wall charging adapter into a wall outlet. The powerstation go rugged AC will automatically begin charging. When the powerstation go rugged AC is fully charged, all ve battery indicator bars will be solid white and the digital screen will indicate 100% charged. This could take up to 9 hours).
NOTE:
• The powerstation go rugged AC is designed to charge between 32°F-113°F (0-45° C). A “TEMP” indicator will be illustrated on the digital display if the powerstation go rugged AC is attempted to be charged outside of this temperature range.
• While charging, the digital screen will illustrate the charge percentage of the powerstation go rugged AC. When fully charged, disconnect the cable.
Figure 1
Jump starting a vehicle
1. Plug the jumper cables into the jump-start output on the powerstation go rugged AC.
NOTE: Make sure the jumper cables are fully plugged into the jump-start output before trying to jump
start your vehicle.
Figure 2
2. Attach the jumper cable clamps to the vehicle battery.
• Red clamp on positive terminal (+)
• Black clamp on negative terminal (-)
NOTE:
• Once the jumper cable clamps are attached to the vehicle battery, the LCD will display the vehicle battery voltage.
• Do not touch red (positive) and black (negative) clamps together at any point. If the jump start button ashes red, the jumper cables have been connected incorrectly. If this ashing red condition occurs, disconnect the jumper cables from vehicle battery and restart the process from Step 1.
Figure 3