Mopec CB100, CA100, CC100, CA200, CB200 User Manual

...
www.mopec.com
C Series
Autopsy Sinks
CA100, CB100, CC100 CA200, CB200, CC200
CC300
Rev 2-29-16 ©
USER MANUAL
P a g e | 2
TABLE OF CONTENTS
UNPACKAGING YOUR PRODUCT..…………………………………………………4 INSTALLATION………..………………………………………………………………..5
ROUGH IN DRAWINGS CA100 ROUGH IN……………………………………………………………..8 CB100 ROUGH IN……………………………………………………………..9 CC100 ROUGH IN……………………………...……………………………..10 CA200 ROUGH IN……………………………………………………………..11 CB200 ROUGH IN …………………………………………………………….12 CC200 ROUGH IN …………………………………………………………….13 CC300 ROUGH IN……………………………………………………………..14
INTRODUCTION ………………………………………………………..……………..15 PRODUCT DRAWINGS
CA100 …………………………………………………………………………..18 CB100 …………………………………………………………………………..19 CC100 …………………………… ……….……………………………………20 CA200……………………………………………………………………………21 CB200……………………………………………………………………………22 CC200………………………………………………………………………23 CC300……………………………………………………………………………24
FEATURES…………………………………………………………………..…….25
Option Information…………………………..………..………..…………….26
AIR HANDLING…………………………………………………….………………..38
CLEANING AND MAINTENANCE
Disinfecting and Cleaning……………………………..…………………..39 Clear Disposal Jam………………………………………………..………..40
Lift Reset Procedure…………………………………………..………....41
Stainless Steel Care and Maintenance………………………………….....42
Parts…………………………………………………………………………..….43 Preventive Maintenance………………………………………………..……..44
WARRANTY………………………………………………………………………..…….45 SAFETY LABELS………………………………………………………………..………46 TROUBLE SHOOTING GUIDE……………………………………………………..….47 CERTIFICATES……………………………………………………………………..……48
UNPACKING
P a g e | 3
1) Carefully inspect the exterior of the shipping container before opening. If the crate is damaged and
the product has sustained damage immediately contact Mopec and the freight carrier. Never discard
the shipping container even if it is damaged beyond recognition.
2) Have the delivery driver note any suspected damage on the Bill of Lading and sign it. Mopec will help
assist in filing a claim for product repair and/or replacement.
3) Carefully open the containers and inspect the equipment for concealed damage. If visible damage is
noticed (i.e. broken welds, dented stainless, scratches, etc.) follow through as noted above. Do not
discard the shipping material. They are important in settling claims.
CAUTION: There are loose components in the packaging of your product. Be very careful in examining
the packaging material as it may contain installation parts and/or product components.
INSPECTION
1) After carefully unpacking your Mopec Grossing station please inspect the items in the list below prior
to installing the unit. The Grossing station should be thoroughly checked for loose screws, defects, or damage that may have occurred during shipping or packaging.
P a g e | 4
INSTALLATION
C Series Autopsy Sink Installation Instructions
Locate package of smaller items (dissection board, tissue boxes, duct hose or filters) The CA100 / CB100 / CC100 is utilized with Autopsy Carts that overhang the sink. It is imperative that the
mounting height is at 34” finished height and is exclusive of any slope in the floor of the building. Placing a bubble level on the edge of the unit’s edge (do not place the level on the table’s surface) side to
side and front to back, assure the unit is completely level. Mount the unit as required with an approved fastener. The fastener is suggested as being a minimum
dimension of 3/8” diameter and having a Tensile Pullout Load of at least 4,000 lbs. .
Once the unit is secured to the wall, the utilities can be hooked up. The cold water line is ¾” and the hot
water is ½” hard copper which will require customer supplied on/off valves. Mopec suggests using ball type
water valves to assure proper water flow for operating all table accessories. Drain lines are standard 1 1/2”
IPS and need to be vented to assure proper drainage.
Utility Connections
The only connections necessary are the Electric, Cold and Hot water supply, the drain connection and the HVAC connections if in house ventilation. If the disposal option is ordered, the disposal will need to be installed prior to the electrical hook up. The unit is already pre wired and plumbed for the options ordered.
Electrical Connection
All electrical, water and ventilation stubs should be prepared in accordance with our rough-in dimensions shown on rough in diagram of this manual.
The electrical service provided for the MB600 must include:
1) A switch or circuit breaker for each circuit to which the wiring harnesses from the workstation will be connected.
Each C Series autopsy sink has a three foot whip for attachment to the facility, unless a plug and cord are requested. The whip leads are labeled. And depending on the options selected there are either 3 wires or 5 wires. L1 and C1 are for the unit electrical options such as lights, lifts and fans if a recirculation unit. L2 and C2 are for the disposal. 115V Info
Without a disposal there are three wires: Black Labeled as L1 White Labeled as C1 Green w Yellow Stripe Ground
With the Disposal there are five wires Black Labeled as L1 White Labeled as C1 Green w Yellow Stripe Ground Red Labeled L2 White Labeled C2
The flexible water tight conduit and connections is the preferred conduit and is not provided with the unit. This is due to an unknown length needed and variances possible in the rough in process. If the disposal option is purchased there MUST be two separate circuits for the two circuits on the autopsy sink. You must have separate circuits for the disposal and unit.
P a g e | 5
Drain Connection
The C Series Elevating Units are equipped with 1.5” Diameter drain and connections. DO NOT modify the drain line or connections without contacting MOPEC first. The Units are built in accordance with the rough in drawings specific to the unit. The drain connection provided unless specifically requested otherwise is Orion
Acid Waste Pipe 1.5” Diameter. The height is per the rough in drawings provided at the time of the order. The C Series non elevating units are equipped for 1.5” DIA drain piping. P-trap and piping is provided
Water Supply Connection
The water supply connections are ½”DIA for Hot water and ¾”DIA for Cold water copper pipe. The unit has been cleared of water and debris during the manufacturing and testing of the unit. The rough in drawing for the unit suggests a 1/4 turn valve to be connected to the wall. This is to allow the water to be localized and disconnected should the need arise to work on plumbing in the future. Before connecting the unit to the facility water supply, check the lines in the facility for debris by flushing the lines for a moment. After the connections are made remove the aerator from the faucet and turn the water on and open the faucet and other water options after the faucet to allow any debris to evacuate the system. Then one option at a time, open the valves for the other water options (i.e. Perimeter Rinse, Spray Hose and then the Disposal). This is the time to look for leaks or other plumbing issues. The plumbing is tested for leaks and function at the facility and is put under pressure for 45 minutes to check for leaks. However the plumbing is hard copper and solder connections. During transport a unit may experience a failed soldier joint. Contact MOPEC immediately if there is a leak.
Ventilation Connection
Ventilation is one of two types for the C Series autopsy sinks; Ventilation of the unit is connected to the facility ventilation system via duct work. The duct work will vary depending on the model of grossing station.
In House
If your unit elevates, it will have flexible duct provided by other’s unless ordered with the unit. The duct/s are connected to the unit on top. The duct stubs are provided. If your unit does not elevate the ventilation connection is on the top or from the back of the unit back of the unit and will vary by model.
** Caution ** These are general guidelines and installation is specific for each of the C Series units.
Professional installation is recommended.
P a g e | 6
Rough In Drawings
The electrical service provided for the C Series must include:
1.) A switch or circuit breaker for each circuit to which the wiring harnesses from the workstation will be connected.
P a g e | 7
CA100 ROUGH IN
P a g e | 8
CB100 ROUGH IN
P a g e | 9
CC100 ROUGH IN
P a g e | 10
CA200 ROUGH IN
P a g e | 11
CB200 ROUGH IN
P a g e | 12
CC200 ROUGH IN
P a g e | 13
CC300 ROUGH IN
P a g e | 14
INTRODUCTION
Mopec’s C Series Wall Mounted autopsy sinks are available in a variety of styles which make them advantageous to a wide variety of users. Including elevating wall mount or leg frame options
The models are as follows: CA 100 model Non-elevating Right Side Approach. Save time and space with our C-Series Wall Mounted
Autopsy Dissection Sinks. The body is transported on a moveable cart that adjoins a right sink approach for easy access. No additional lifting of the body is required. The cart trays overhang the sink to allow for proper fluid drainage.
CB 100 model Non-elevating Left Side Approach. Save time and space with our C-Series Wall Mounted
Autopsy Dissection Sinks. The body is transported on a moveable cart that adjoins a left sink approach for easy access. No additional lifting of the body is required. The cart trays overhang the sink to allow for proper fluid drainage.
Both the CA100 and CB100 offer the following features: Overall Dimensions: 84" L x 28" W x 61" H, 34" (FFL) to bottom of work surface.
Stainless Steel construction. Hydro aspirator with reversing flow valve, hose hanger and 8' clear PVC tubing. Cold water body rinse with vacuum breaker and serrated hose fitting. Includes hose hanger and 8' clear PVC tubing. Hot and cold water fixture with wrist blade handles and 8" swing spout with vacuum breaker. Two (2) interchangeable removable perforated grid plates, stainless steel construction with 1/2" recess and 3/8" diameter holes on 2" square centers. Rinse basket grid plate fabricated with stainless steel construction. GFCI duplex outlet with waterproof cover. Instrument drawer flush to the table when closed and fitted with flush inset handles at the top to keep fluid from accumulating in the drawers. Hand spray assembly, heavy duty brass chrome plated hand piece. Durable 8' Long high pressure hose. J hook to hold hand piece. Concealed pressure control/shut off. Includes cart latch which is compatible with DA000 & DB000 cart chassis only. Other Mopec carts can be used by locking casters. All plumbing and electrical work accomplished at factory. Only trade hook up required.
CC 100 model Non-elevating Center Approach. Save time and space with our C-Series Wall Mounted
Autopsy Dissection Sinks. The body is transported on a moveable cart that adjoins a center sink approach for easy access. No additional lifting of the body is required. The cart trays overhang the sink to allow for proper fluid drainage.
Overall Dimensions: 114" L x 31-1/2"W x 58- 1/2" H to 66-1/2 to work surface. 31-1/2" to 39.5" (100cm) to top of work surface Stainless steel construction. Center sink approach Heavy duty elevating frame structure with dual synchronized actuators and push button controls. Hydro aspirator with reversing flow valve. Includes hose hanger and 8' of clear PVC tubing. Two (2) cold water body rinse valve with vacuum breaker and serrated hose fitting. With hose hanger and 8' of clear PVC tubing. Two (2) Hot and cold water fixture with wrist blade handles, 8" swing spout with vacuum breaker. Four (4) interchangeable removable grid plates stainless steel construction with 1/2" recess and 3/8" diameter holes on 2" square centers. Two GFCI duplex outlet with waterproof cover. Two instrument drawers with recessed handle and drop in removable pan. Two hand spray rinse. Heavy duty brass chrome plated hand piece. Durable 8' long flexible hose. Hose hanger and "J" hook to hang hand piece. Concealed pressure control/shut off. Includes cart latch which is compatible with DA000 & DB000 cart chassis only. Other Mopec carts can be used by locking casters. All plumbing and electrical work accomplished at factory. Only trade hook up required.
The above 100 series are available with the optional leg frame support
P a g e | 15
Loading...
+ 34 hidden pages