Moog Warrior 6 Installation

Warrior 6
Discrete Vandal Resistant Camera System
Table of Contents
Cable and Power Guidelines Installation Preparation Installation Procedure Wiring Optional Warrior Test Monitor Cable
Camera Bracket Setup Camera Focusing Camera Settings Completion of Installation Window Guard
Replacement
Installation and Operation Instructions
Before attempting to connect or operate this product, please read these instructions completely.
NVT Instructions Warranty Information Service and Safeguard Information Troubleshooting
© 2013, Moog Inc. All Rights Reserved
Moog Inc.
Sensor and Surveillance Systems
3650 Woodhead Drive Northbrook, IL. USA 60062
+1.847.498.0700 Fax: +1.847.498.1258 www.moogS3.com
IMPORTANT SAFEGUARDS SAFETY PRECAUTIONS
avvertire l’utente alla presenza delle istruzioni importanti nella
MADEIN
BUY AMERICA COMPLIANT • COUNTRY OF ORIGIN U.S.A.
1 Read these instructions.
2 Keep these instructions.
3 Heed all warnings
4 Follow all instructions.
5 Do not use this apparatus near water.
6 Clean only with damp cloth.
7 Do not block any of the ventilation openings. Install in accordance with the
manufacturers instructions.
8 Cable Runs- All cable runs must be within permissible distance.
9 Mounting - This unit must be properly and securely mounted to a supporting
structure capable of sustaining the weight of the unit.
Accordingly:
a. This installation should be made by a qualied service person and should conform
to all local codes.
b. Care should be exercised to select suitable hardware to install the unit, taking into
account both the composition of the mounting surface and the weight of the unit.
10 Do not install near any heat sources such as radiators, heat registers, stoves, or other
apparatus ( including ampliers) that produce heat.
11 Do not defeat the safety purpose of the polarized or grounding-type plug. A
polarized plug has two blades with one wider than the other. A grounding type
plug has two blades and a third grounding prong. The wide blade or the third
prong are provided for your safety. When the provided plug does not t into your
outlet, consult an electrician for replacement of the obsolete outlet.
12 Protect the power cord from being walked on or pinched particularly at plugs,
convenience receptacles, and the point where they exit from the apparatus.
13 Only use attachment/ accessories specied by the manufacturer.
14 Use only with a cart, stand, tripod, bracket, or table specied by the manufacturer,
or sold with the apparatus. When a cart is used, use caution when moving the cart/
apparatus combination to avoid injury from tip-over.
15 Unplug this apparatus during lighting storms or when unused for long periods of time.
16 Refer all servicing to qualied service personnel. Servicing is required when the
apparatus has been damaged in any way, such as power-supply cord or plug is
damaged, liquid has been spilled of objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not operate normally, or
has been dropped.
Be sure to periodically examine the unit and the supporting structure to make sure that the integrity
of the installation is intact. Failure to comply with the foregoing could result in the unit separating
from the support structure and falling, with resultant damages or injury to anyone or anything struck
by the falling unit.
CAUTION: TO REDUCE THE RISK OF
ELECTRIC SHOCK, DO NOT REMOVE
COVER ( OR BACK). NO USER- SERVICE-
ABLE PARTS INSIDE. REFER SEVICING
TO QUALIFIED SERVICE PERSONNEL.
The lightning ash with an arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of non-insulated “dangerous voltage” within the product’s enclosure that may be of sufcient magnitude to constitute a risk to persons.
Este símbolo se piensa para alertar al usuario a la presencia del “voltaje peligroso no-aisIado” dentro del recinto de los productos que puede ser un riesgo de choque eléctrico.
Ce symbole est prévu pour alerter I’utilisateur à la presence “de la tension dangereuse” non-isolée dans la clôture de produits qui peut être un risque de choc électrique.
Dieses Symbol soll den Benutzer zum Vorhandensein der nicht-lsolier “Gefährdungsspannung” innerhalb der Produkteinschließung alarmieren die eine Gefahr des elektrischen Schlages sein kann.
Este símbolo é pretendido alertar o usuário à presença “di tensão perigosa non-isolada” dentro do cerco dos produtos que pode ser um risco de choque elétrico.
Questo simbolo è inteso per avvertire I’utente alla presenza “di tensione pericolosa” non-isolata all’interno della recinzione dei prodotti che può essere un rischio di scossa elettrica
.
The exclamation point within an equilateral triangle is intended to alert the user to presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
UNPACKING
Unpack carefully. Electronic components can be damaged if improperly handled or dropped. If an item appears to have been damaged in shipment, replace it properly in its carton and notify the shipper.
Be sure to save: 1 The shipping carton and packaging material.
They are the safest material in which to make future shipments of the equipment.
2 These Installation and Operating Instructions.
Este símbolo del punto del exclamation se piensa para alertar al usuario a la presencia de instrucciones importantes en la literatura que acompaña la aplicación.
Ce symbole de point d’exclamation est prévu pour alerter l’utilisateur à la presence des instructions importantes dans la littérature accompagnant l’appareil.
Dieses Ausruf Punktsymbol soll den Benutzer zum Vorhandensein de wichtigen Anweisungen in der Literatur alarmieren, die das Gerät begleitet.
Este símbolo do ponto do exclamation é pretendido alertar o usuário à presença de instruções importantes na literatura que acompanha o dispositivo.
Questo simbolo del punto del exclamaton è inteso per
letteratura che accompagna l'apparecchio.
SERVICE
If technical support or service is needed, contact us at the following number:
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
TECHNICAL SUPPORT AVAILABLE 24 HOURS
1- 800-554 -1124
Product Warranty Registration
Register Your Products Online
www.moogS3.com/technical-support/product-registration
Moog values your patronage. We are solely committed to providing you with the highest quality products and superior customer service. With 3-Year and 5-Year warranties (depending on the product purchased) we stand behind every product we sell.
See full warranty details at www.moogS3.com/technical-support/warranty-plan/
:
• Simple and Trouble-Free RMA process
• Product / software updates
• Special promotions
• Eliminate the need to archive purchase documents such as receipts, purchase orders, etc.
Limited Warranty for Moog Products
MANUFACTURER HEREBY DISCLAIMS ANY REPRESENTATIONS OR WARRANTY THAT THE PRODUCT IS COMPATIBLE WITH ANY COMBINATION OF NON-MANUFACTURER
THE LIABILITY OF Manufacturer, IF ANY, AND PURCHASER’S SOLE AND EXCLUSIVE REMEDY FOR DAMAGES FOR ANY CLAIM OF ANY KIND WHATSOEVER, REGARDLESS OF THE LEGAL THEORY AND WHETHER ARISING IN TORT OR CONTRACT, SHALL NOT BE GREATER THAN THE ACTUAL PURCHASE PRICE OF THE PRODUCT WITH RESPECT
Moog - Decatur Operations, subsequently referred to as “Manufacturer,” warrants these products to be free from defects in material or workmanship as follows:
PRODUCT CATEGORY PARTS \ LABOR
All Enclosures and Electronics Five (5) Years
Accessory Brackets Five (5) Years
Controllers Three (3) Years
Power Supplies / IR Illuminators Three (3) Years
Poles / PolEvators
Warrior Series
SView Series
DeputyDome
EXO Series
EXO Series
During the labor warranty period, to repair the Product, Purchaser will either return the defective product, freight prepaid, or deliver it to Manufacturer at Moog Decatur Operations, 2525 Park Central Boulevard, Decatur, Georgia, 30035. The Product to be repaired is to be returned in either its original carton or a similar package affording an equal degree of protection with a RMA # (Return Materials Authorization number) displayed on the outer box or packing slip. To obtain a RMA# you must contact our Technical Support Team at 800.554.1124, extension 101. Manufacturer will return the repaired product freight prepaid to Purchaser. Manufacturer is not obligated to provide Purchaser with a substitute unit during the warranty period or at any time. After the applicable warranty period, Purchaser must pay all labor and/or parts charges. The limited warranty stated in these product instructions is subject to all of the following terms and conditions.
TERMS AND CONDITIONS
1. NOTIFICATION OF CLAIMS: WARRANTY SERVICE: If Purchaser believes that the Product is defective in material or workmanship, then written notice with an explanation
of the claim shall be given promptly by Purchaser to Manufacturer. All claims for warranty service must be made within the warranty period. If after investigation, Manufacturer determines the reported problem was not covered by the warranty, Purchaser shall pay Manufacturer for the cost of investigating the problem at its then prevailing per incident billable rate. No repair or replacement of any Product or part thereof shall extend the warranty period of the entire Product. The specic warranty on the repaired part only shall be in effect for a period of ninety (90) days following the repair or replacement of that part or the remaining period of the Product parts warranty, whichever is greater.
/ CamEvator Three (3) Years
, NiteTrac™, Igloo Dome, PurgeDome
Dome and Fixed Camera Systems* Three (3) Years 6 months if used in auto scan / tour operation
GeminEye Visible and Thermal Camera Systems One (1) Year
/ Q-View
Three (3) Years
Three (3) Years 6 months if used in auto scan / tour operation
Three (3) Years 6 months if used in auto scan / tour operation
2. EXCLUSIVE REMEDY: ACCEPTANCE: Purchaser’s exclusive remedy and Manufacturer’s sole obligation is to supply (or pay for) all labor necessary to repair any Product
found to be defective within the warranty period and to supply, at no extra charge, new or rebuilt replacements for defective parts.
3. EXCEPTIONS TO LIMITED WARRANTY: Manufacturer shall have no liability or obligation to Purchaser with respect to any Product requiring service during the warranty
period which is subjected to any of the following: abuse, improper use, negligence, accident, or acts of God (i.e., hurricanes, earthquakes), modication, failure of the end-user to follow the directions outlined in the product instructions, failure of the end-user to follow the maintenance procedures recommended by the International Security Industry Organization, written in product instructions, or recommended in the service manual for the Product. Furthermore, Manufacturer shall have no liability where a schedule is specied for regular replacement or maintenance or cleaning of certain parts (based on usage) and the end-user has failed to follow such schedule; attempted repair by non-qualied personnel; operation of the Product outside of the published environmental and electrical parameters, or if such Product’s original identication (trademark, serial number) markings have been defaced, altered, or removed. Manufacturer excludes from warranty coverage Products sold AS IS and/or WITH ALL FAULTS and excludes used Products which have not been sold by Manufacturer to the Purchaser. All software and accompanying documentation furnished with, or as part of the Product is furnished “AS IS” (i.e., without any warranty of any kind), except where expressly provided otherwise in any documentation or license agreement furnished with the Product. ANY COST ASSOCIATED WITH REMOVAL OF DEFECTIVE PRODUCT AND INSTALLATION OF REPLACEMENT PRODUCT IS NOT INCLUDED IN THIS WARRANTY.
4. PROOF OF PURCHASE: The Purchaser’s dated bill of sale must be retained as evidence of the date of purchase and to establish warranty eligibility.
DISCLAIMER OF WARRANTY
EXCEPT FOR THE FOREGOING WARRANTIES, MANUFACTURER HEREBY DISCLAIMS AND EXCLUDES ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO ANY AND/OR ALL IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND/OR ANY WARRANTY WITH REGARD TO ANY CLAIM OF INFRINGEMENT THAT MAY BE PROVIDED IN SECTION 2-312(3) OF THE UNIFORM COMMERCIAL CODE AND/OR IN ANY OTHER COMPARABLE STATE STATUTE.
PRODUCTS OR NON-MANUFACTURER RECOMMENDED PRODUCTS PURCHASER MAY CHOOSE TO CONNECT TO THE PRODUCT.
LIMITATION OF LIABILITY
TO WHICH SUCH CLAIM IS MADE. IN NO EVENT SHALL MANUFACTURER BE LIABLE TO PURCHASER FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OF ANY KIND INCLUDING, BUT NOT LIMITED TO, COMPENSATION, REPLACEMENT LABOR COSTS, REIMBURSEMENT, OR DAMAGES ON ACCOUNT OF THE LOSS OF PRESENT OR PROSPECTIVE PROFITS OR FOR ANY OTHER REASON WHATSOEVER.
CABLE AND POWER GUIDELINES
(Detailed info on Page 11)
This chart shows the proper current needed for power supplies for Warrior Series cameras. Use Class 2 Power only. Input voltage must be between 12-28 Vdc or 15-28 Vac.
VOLTAGE CURRENT POWER
12 Vdc 350mA 4.2W
24 Vac 202mA 4.8W
Depending on the voltage being used, refer to one of the formulas below to select the correct power supply for cameras connected in parallel (positive to positive, negative to negative):
Total current for a 12 Vdc system: TOTAL CURRENT = (350mA x total number of cameras)
Total current for a 24 Vac system: TOTAL CURRENT = (202mA x total number of cameras)
INSTALLATION PREPARATION
INSTALLATION PREPARATION
4. Feed the wiring through the conduit knockout. A clamp connector is included
should you desire to use it. Install the connector so that the nut is on the outside of the housing. Be sure the hole in the wall is large enough to accommodate the nut. Tighten the nut securely, making sure that the screw heads on the connector are in an easy to reach position, then feed the wiring through the clamp connector.
5. Mount the back box to the wall using appropriate hardware (not provided). NOTE: If the clamp connector was used, tighten the screws at this time. Make sure enough wire is inside the back box to complete the wiring process.
WIRING (Figure 3)
Use Class 2 Power only. Input voltage must be between 12-28 Vdc or 15-28 Vac.
1. Connect the output of your Class 2 Power Supply to the terminal connectors on
the PC Board inside the housing. Refer to the Troubleshooting section later in this instruction sheet for more information.
2. Connect the incoming video cable to the BNC connector. NOTE: For NVT Twisted Pair see Addendum 1.
Terminal Connector
1. Choose an appropriate corner location. The WS6 can be mounted at any height in a corner.
2. Complete all wire and conduit runs prior to installation of the housing.
INSTALLATION PROCEDURE
1. Using the security tool provided, loosen the (3) 10-32 security fasteners and
remove the face plate (Figure 1).
Figure 1
2. Place the back box into position and mark the four mounting holes (Figure 2).
3. If you're using the top conduit knockout (Figure 2) REMOVE THE CAMERA AND
BRACKET TO PREVENT DAMAGE. If using one of the side conduit knockouts it's not necessary to remove the camera and bracket; however, use caution.
Top conduit knockout behind camera CAMERA MUST BE REMOVED BEFORE USING
Power Board
Connect to incoming video BNC
Figure 3
Positive
Connected to the Camera
Negative
Mounting Holes
Figure 2
Mounting Holes
OPTIONAL WARRIOR TEST MONITOR CABLE (Part # - WSTMC)
DESCRIPTION
The Warrior Test Monitor Cable is a tool that allows users to view video from cameras via a small on-site monitor. It's quick and easy to use.
1. Using the security tool provided, loosen the four security fasteners and remove the housing top. NOTE: The housing top is held to the base by a lanyard.
2. Locate the power board on the inside of the housing. The Test Monitor Cable plug is
located beside the terminal block where incoming power is connected (Figure 4).
Terminal Connector
Power Board
CAMERA BRACKET SETUP
1. To adjust the camera bracket, loosen the two thumb screws (Figure 6). When
the desired focus and location are achieved tighten the thumb screws on the brackets in place using needlenose pliers. Use Loctite™ or equivalent to secure the screws,especially in installations where vibration is a concern.
Terminal Connector
Video Connector
Test Monitor Cable plug
Figure 4
3. Plug the test monitor cable into the power board (Figure 5). Attach the BNC connector to your test monitor.
The plug for the Test Monitor Cable is polarity protected and can only be inserted one way.
Figure 6
Bracket adjustment thumb screws
CAMERA FOCUSING (Figure 7)
1. The camera is factor y equipped with a 3.6mm xed lens. A 2.5 mm lens is also provided.
To remove the 3.6 mm lens. Turn the lens counter clockwise. Note there is no set screw for this model. Make sure to use the spring with the 2.5 mm lens.
2. Fine focusing of the lens: Gently grip the end of the lens. Manually rotate the lens until a clear picture is achieved. Note there is no set screw for this model. The spring applies pressure to the lens and prevents it from moving.
Test Monitor Cable (NOTE: Your cable may look different)
Figure 5
NOTE: The following instructions are for camera bracket setup, camera focusing, and camera set-up. The nal steps for installation follow these sections.
Figure 7
COMPLETION OF INSTALLATION
Reattach the front plate to the back box and tightly fasten the (3) security screws using the security tool.
WINDOW GUARD™ PAINT SHIELD REPLACEMENT
Your Warrior 6 comes with a replaceable Window Guard™ paint shield to protect the front plate window from vandalism. If vandalism occurs (spray paint, scratches, etc.) you need only replace the shield, not the entire window. Additional shields can be ordered. To replace the shield, use the following directions.
1. Remove the face plate.
2. On the inside of the face plate, remove the (4) 6-32 nuts holding the window in place (Figure 8).
3. Remove the damaged paint shield.
4. Place a new shield in front of the window. Reinstall the window, making sure to securely tighten the (4) nuts. Reinstall the face plate.
Window
Window Guard™ Paint Shield
Figure 8
ADDENDUM 1
UNSHIELDED TWISTED PAIR VIDEO WIRING
NOTE: The customer must purchase the Video Transceiver from NVT. Part numbers are:
• NV-212A (500 ft.)
* NV-213A or NV-213A-M (1000 ft.)
• NV-652R, NV-862R, or NV-1662R (3000 ft.)
The cameras included in the Warrior series are able to transmit video signals to NVT receivers via unshielded twisted pair cable. You must purchase the receiver separately. Instructions for connecting the receiver end of the unshielded twisted pair cable will be included with the NVT receiver. Following are instructions for connecting the unshielded twisted pair cable to the PC board inside your Warrior housing. See the TROUBLESHOOTING section in the back of these instructions if you experience any problems.
1. Connect the unshielded twisted pair cable to the positive and negative screw terminals on the Warrior PC board (Figure 9).
Video Negative (-)
Video Positive (+)
Figure 9
2. Connect the other end of the unshielded twisted pair cable to the NVT receiver. CAUTION: The unshielded twisted pair video signal is polarity dependent. The positive video terminal on the Warrior PC board MUST be connected to the positive terminal on the
NVT receiver, and negative MUST be connected to negative.
3. When using unshielded twisted pair cable you DO NOT need the BNC connector. Be sure that there is no video connection other than the unshielded twisted pair cable.
PC Board
Wiring Notes
Wire — What to DO
1. DO use point-to-point Unshielded Twisted Pair wire, gauge 24 or thicker, stranded
or solid, Category 2, 3, 4, or 5.
2. The video signal may co-exist in the same wire bundle as other video, telephone, data, control signals, or low-voltage power. It is also OK to run NVT video signals in or near electromagnetic fields (in accordance with National Electrical Code, local, or other local safety requirements).
3. DO measure the wire distance. Use only transceivers that are designed for that distance.
4. DO make sure the pair of wires carrying the video signal is sent as a twisted pair (e.g. the blue-white/white-blue wires twisted together as a pair), not a “split­pair” (e.g. blue-white conductor, part of one pair/orange-white conductor, part of another pair).
Wire — What NOT to DO
1. DO NOT USE SHIELDED TWISTED PAIR WIRE. It will severely degrade the distance performance. Short runs may be used with some signal degradation (for example elevator traveler cables). Multi-pair wire with an overall shield is OK.
2. DO NOT USE UN-TWISTED WIRE. It will reduce the NVT product’s inherent interference immunity.
3. DO NOT allow your installation to have “bridge-taps”, loading coils, talk-battery, or MOV type protectors. Bridge-taps are where a twisted pair is connected to two twisted pairs (such as an extension phone at home). Bridge-taps cause reflections as the signal propagates, resulting in “ghosts” in the video image, and are to be avoided.
4. If the phone company is providing the cable runs between buildings, make sure it’s “dry copper” i.e. it should have none of the following: dial-tone, 48 volts, loading coils, bridge-taps, switching, or long paths to the phone company’s central office and back.
5. Due to near-end crosstalk, DO NOT send a transmit and a receive signal in the same wire bundle. Exceptions: Less than 1,000 ft (300m), or Category 5 cable, up to 2,000 ft (600m) are OK.
6. DO NOT send “Up-the-Coax” Pan/Tilt/Zoom signals through active (amplified) NVT transceivers.
3
7. For safety, never put NVT signals in the same conduit as high-voltage
!
wiring.
8. WARNING — to reduce a risk of fire or electrical shock, do not expose
!
this product to rain or moisture.
Measure your wire distance
Note: All NVT quoted distance specifications include any coax in the run. It is recommended that the wire distance be measured to ensure that the capability of the NVT product is correct.
Wire resistance may be measured with an ohm-meter by shorting the two conductors together at the far end, and measuring the loop-resistance out and back. Compare your readings with the charts on the next page.
43
WS6 ­Exploded Diagram and Replacement Parts List
21
65
Part Number Description
1 RPWS6010 WARRIOR 6 FACE PLATE FASTENER KIT
2 RPWS6020 WARRIOR 6 FRONT PLATE ASSEMBLY
3 WS6PS WARRIOR 6 REPLACEMENT PAINT SHIELD
4 RPWS6040 WARRIOR 6 REPLACEMENT WINDOW KIT
NTSC BOARD CAMERAS
5 RPWS6050 WARRIOR 6 STANDARD RES, BLACK & WHITE, FIXED CAMERA KIT
RPWS6051 WARRIOR 6 STANDARD RES, COLOR, FIXED CAMERA KIT
RPWS6052 WARRIOR 6 HI-RES, COLOR, FIXED CAMERA KIT
PAL BOARD CAMERAS
RPWS6050P WARRIOR 6 PAL STANDARD RES, BLACK & WHITE, FIXED CAMERA KIT
RPWS6051P WARRIOR 6 PAL STANDARD RES, COLOR, FIXED CAMERA KIT
RPWS6050P WARRIOR 6 PAL HI-RES, COLOR, FIXED CAMERA KIT
6 RPWS6060 WARRIOR 6 CORNER PLATE
Not shown items
RPWS6070 WARRIOR 6 PACKET KIT
y
AC Voltmeter
TROUBLESHOOTING
If you experience problems with the camera picture please check these simple troubleshooting procedures for possible solutions before calling technical support.
STATIONARY OR SCROLLING HORIZONTAL LINES ON SCREEN
GROUND LOOPS Generally a horizontal line on screen, whether moving or stationary, means you have a ground loop problem. The video shield should only be connected to ground through the monitor or other electronic equipment that uses the video signal. Connecting the video shield to ground at the camera will create a ground loop, which may interfere with the video signal (See Figure A). This should not damage the camera, but the video signal may become unusable. A ground loop problem will cause a dark horizontal bar to slowly “scroll" through the picture. To solve this problem, remove all ground connections from the video connection EXCEPT for the ground at the terminating end of the video signal.
The video termination should be a 75-ohm impedance, standard in monitors and other video equipment. If the video signal goes to more than one piece of equipment, a monitor and multiplexer input for instance, insure that one and only one piece of equipment terminates the video signal with 75 ohms; otherwise the image will be degraded and may appear to be unusually dim.
Power A
Camera Assembly
Power B
Video Signal
(Ground Return)
Video Shield
Figure A Ground Loop
IMPORTANT NOTE: If you have removed the ground loop and the horizontal line still remains on screen call Moog technical support for further information.
Power Supply
Primar Power
Monitor
NVT TROUBLESHOOTING
If you are experiencing problems, attempt to simplify your setup. Test each cable segment separately. For example, test the camera and monitor together without the other equipment. Then add in the NVT transceivers, back-to-back. Test each segment of a long cable-run independently. Attempt to isolate the problem.
Below are problems that may be encountered. If the suggestions below are not helpful, or the recommendations are not effective, please call NVT’s customer support. NVT customer support can be reached 8:00 AM to 5:30 PM PST at (800) 959-9870 or at (+1) (650) 562-0600.
FAINT OR BLURRY PICTURE; LITTLE OR NO COLOR
Possible causes include:
1. Shielded twisted-pair cable. Verify that the wire is unshielded twisted-pair cable. Multi-pair cable with an overall shield is OK.
2. Longer wire distance than expected. Be sure to include any coax cable that’s part of this distance. Verify end-to-end connectivity with an ohm meter. Measure the distance by disconnecting the transceivers, shorting the far end, reading the loop’s resistance at the near end. See above for ohm vs. distance ratings. If necessary, replace transceivers with correct models specified for this distance.
3. Incorrect distance equalization setting. Adjust the equalization controls) with a mini screwdriver (NV-652R, NV-862R or the NV-1662R). If the transmitter is an NV-653T, verify correct equalization switch setting.
4. Poor connection at a punch-block, splice, or coax cable. Re-check using the method described in #2 above, or use a wire test set.
5. Short between conductors of the twisted-pair. Use an ohm meter to locate the short.
6. Transient protection devices employing metal-oxide varistors. Use carbon blocks, gas-discharge tubes, or NVT transceivers w
7. Check the camera. Are the focus and iris set correctly? Verify with portable monitor.
EXTREMELY FAINT PICTURE
Only faint shadows of the original picture are visible. One of the twisted pair conductors is open or the wires are shorted together. Check with an ohm meter.
OVER-SATURATED COLORS; HIGH CONTRAST GRAINY PICTURE; TOO BRIGHT, TORN PICTURE
Adjust the distance equalization as necessary. Verify that the monitor has a 75 termination, not in “loop-through”.
WON'T SYNC; WIDE, WHITE JAGGED AREAS
Looks like a scrambled Cable TV signal. Check polarity.
WON'T SYNC; TORN PICTURE
1. Make sure that you are using sunshielded twisted pair wire.
2. Check distance equalization settings.
3. For installations with passive (non-amplified) transceivers at both ends, check for ground loops. This may be done with an AC Voltmeter, as shown below:
ith built-in protection.
AUTOMATIC BROWN OUT FEATURE
The camera includes an automatic brown out feature which is activated whenever the incoming voltage drops below 10 Vac or Vdc.
LINE LOCK
All cameras are all shipped from the factory with the line lock function disabled. If your
application requires Line Lock contact Moog.
If the voltage is greater than 1/2 volt, use an amplified receiver, such as the
NV-652R, NV-862R, or NV-1662R.
Alternately, remove the ground at one end (usually at the camera end). Be sure that
floating the camera conforms to local/regional and National Electrical Codes.
Camera
Bridge Tap
4. Check for crosstalk from a second video path. Disconnect all other video sources. If the problem goes away, check for a split-pair or un-twisted wire.
FAINT STRIPES GLIDING UP OR DOWN THE SCREEN
These are caused by crosstalk from a second video path, or with ground-loops in installations employing passive models at both ends.
1. To identify, disconnect all other video signals temporarily. If the interference goes away, check the wire to make sure the signal is traveling through a twisted pair. Is two­way video being sent more than 1,000 ft (300m) over Category 2 or 3 wire? If so, the send and receive signals may need to go in separate jacketed cables, or upgrade to Category 5 wire.
2. Next, check for ground loops. See #3 above.
NO POWER LIGHT ON THE NVT UNIT
Check the blue “power” LED on powered NVT units. If the light is not on, the receiver is not getting power. Re-check the power source and connections. If the green LED is on but the power LED is off, check that the power supply is floating. Grounding one side of the power input may cause this condition.
NO GREEN LIGHT, NO VIDEO
The NV-652R, NV-862R or NV-1662R series receiver/hub is not detecting a video signal. There is an open or shorted connection. Use a multimeter to locate the fault.
GHOSTS
Faint shadows of the original signal shifted to the right. This is caused by an impedance mismatch along the wire. Verify that the monitor is terminated with 75 (not in “loop­through”.) Check that all wire is unshielded twisted pair. The high-frequency wire impedance should be 100. Check for bridge-taps (see below) either by inspecting wiring closet connections, or, if available, using a “Time-Domain Reflectometer” (T.D.R.), sometimes called a “cable tester”.
If the faint shadows are not copies of the original picture, but from the picture of some other camera, check for crosstalk:
Is any portion of the wire un-twisted?
Are the signals from two cameras split between two pairs?
Is there a short between a conductor of one signal and a conductor of another?
NV-213
A
NV-213
A
Monitor
CABLE AND POWER GUIDELINES
This chart shows the proper current needed for power supplies for Warrior Series cameras. Use Class 2 Power only. Input voltage must be between 12-28 Vdc or 15-28 Vac
VOLTAGE CURRENT POWER
12 Vdc 350mA 4.2W
24 Vac 202mA 4.8W
Depending on the voltage being used, refer to one of the formulas below to select the correct power supply for cameras connected in parallel (positive to positive, negative to negative):
Total current for a 12 Vdc system: TOTAL CURRENT = (350mA x total number of cameras) Example: 350mA x 5 total cameras = 1750mA
Total current for a 24 Vac system: TOTAL CURRENT = (202mA x total number of cameras) Example: 202mA x 5 total cameras = 1010mA
NOTE: If you're using a 12 Vdc power supply and experience problems check the voltage at the camera's power input. This voltage should not
be less than 11 Vdc. If you're measuring less than 11 Vdc you'll need to use a power supply with a higher current rating.
Power Supply Cable Maximum Length (feet/meters)
Total Load Power Supply 24 AWG 22 AWG 18 AWG 16 AWG
4.2W 12 Vdc 55/16 88/26 223/67 355/108
4.8W 24 Vac 867/264 1380/420 3488/1063 5547/1690
NOTE: The above table is based on a "worst-case" power supply. Using a regulated or switching power supply can increase your cable distance. A CSA/UL listed Class 2 power supply must be used. Moog recommends its PS12 12 Vdc 1000mA power supply for 12 Vdc applications
Video Cable Maximum Length (feet/meters)
Cable Type RG-59 RG-6 RG-11
Wire Gauge 23 AWG* 18 AWG* 16 AWG*
Max. Length 750/229 1500/457 1800/549
* Copper clad steel core, 95% braided shield
Maximum Length (feet/meters)
AWG 250/76 500/152 1000/305 1500/457 2000/610 3000/914
18 3Ω 6Ω 13Ω 19Ω 26Ω 40Ω
20 5Ω 10Ω 20Ω 30Ω 40Ω 59Ω
22 8Ω 17Ω 33Ω 48Ω 66Ω 99Ω
24 13Ω 26Ω 52Ω 78Ω 108Ω 163Ω
Loading...