montwill M1 User Manual

Technical features:
• red display of -1999…9999 digits (optional: green, orange or blue display)
• minimal installation depth: 25 mm without plug-in terminal
• digit height 14 mm
• far range power supply 100-240 VAC or standard supply 230 VAC or 24 VDC
• display adjustment via factory presetting or directly on the sensor signal
• min/max-memory
• display flashing at threshold value exceedance/undercut
• Tara-function
• sliding averaging
• programming interlock via access code
• protection class IP65 at the front
• pluggable screw terminal
• accessories: PC-based configuration software incl. CD and USB-adapter for devices without keypad and for a simple adjustment of standard devices.
User manual M1 – Multi-function device
Measuring inputs: Direct voltage, Direct current, Pt100(0), Thermocouple,
Frequency, Rotation speed, Counter
96x48
M1_1UGB.pdf update: 12.09.2017
Identification
STANDARD-TYPES ORDER NUMBER
Multi-function measuring inputs Housing size: 96x48 mm
M1-1UR4B.000X.S70AD M1-1UR4B.000X.570AD M1-1UR4B.000X.770AD
Options – break-down order key:
Please state physical unit by order, e.g. mbar
M1-1UR4B.000X. S 7 0 AD
Standard type M-Line Dimension
D physical unit
Installation depth
38 mm incl. plug-in terminal 1
Version
AA
Housing size
96x48x 25 mm (BxHxD) 1
Switching points
0 without
Display type
Multi-funct ion display U
Protection class
1 without keypad, operation on the bac k
Display colours
via PC software PM-TOOL
Green G 7 IP65/pluggable terminal
Red R
Orange Y
Voltage supply
Blue B 5 230 VA C 50/60 Hz
7 24 VDC galv. isolated
Numbe r o f di gi ts
S 100-240 VAC / DC +/-10%
4-digit 4
Measuring input
Digit height
X Voltage, Current, Temperature,
14 mm B Frequency
Interface Analog output
without 0 0 without
Sensor supply
0 without
Contents
1
1. Brief description
2. Assembly
3. Electrical connection and connection examples
3.1. Terminal pin assignment
3.2. Connection examples
3.2.1. Voltage / Current
3.2.2. Pt100 / Pt1000 / Thermocouple
3.2.3. Frequency / Rotation speed
3.2.4. Counter
4. Description of function and operation
4.1. Operating and display elements
4.2. Programming software PM-TOOL
5. Setting-up the device
5.1. Switching on
6. Parameterisation
6.1. Selection of input signal, Type
6.1.1. Voltage/Current, Volt, AMPE
Setting of the final and inital value, End, Enda, offs, offa
Setting of the decimal point, Dot.A
Zero point slowdown of the input signal, zero
Taring value, tara
Overflow/underflow behaviour, over
Input of supporting points for linearisation of the measuring signal, spc.A
6.1.2. Pt100, Pt1000, Thermocouple, pt.se, ther
Temperature device in °C/°F, unit
Impedance matching, offs
6.1.3. Pulse measuring, impu
6.1.3.1. Frequency, freq
Pulse triggering, i.typ
Range of frequency, rang
Filter, filt
Adjustment of final and initial value, end, endf, offs, offf
Adjustment of the decimal point, dot.F
Taring value, tara
Input of supporting points for linearisation of the measuring signal, spc.F
6.1.3.2. Rotation speed, turn
Pulse triggering, i.typ
Filter, filt
Pulse per revolution, ppt
Time base, time
Adjustment of the decimal point, dot
3
3
4
4
4
4
5
5
6
7
7
7
8
8
8
8
9
10
10
10
10
10
10
11
11
11
12
12
13
13
13
14
14
14
14
14
15
15
15
15
15
Contents
2
6.1.3.3. Counter upwards/downwards, Co.up, Co.dn
Pulse triggering, i.typ
Counter base / Input signal, co.ba
Wing, edge
Prescaler, pres
Display value and pulse final numerical value, end, end.c
6.2. General device parameter
Adjustment of measuring time, sec
Adjustment of the sliding average value, glm
Presentation of initial/final value in the display, di.hi, di.lo
Allocation of functions onto the navigation keys, tast
Display flashing at threshold value exceedance/undercut, flas
6.3. Alarm parameter
Limit value behaviour, a1.fu, a2.fu
Alarm flashing in case of limit value errors, a1.er, A2.er
Adjustment of the switching threshold, a1.li, a2.li
Adjustment of the hysteresis, a1.hy, a2.hy
Upper limit value, a1.lo, a2.lo
Lower limit value, a1.hi, a2.hi
Drop off delay, a1.of, a2.of
Activation delay, a1.on, a2.on
6.4. Safety parameter – locking of the parameterisation
Assignment of individual numerical codes, Code
Activation/Deactivation of the programming interlock, run
7. Reset to default values
Setting back the parameter onto delivery condition
8. Technical data
9. Safety advices
10. Error elimination
16
16
16
16
17
17
17
17
18
18
18
18
18
19
19
19
19
19
19
19
19
20
20
20
20
21
23
24
3
1. Brief description / 2. Assembly
1. Brief description
The panel instrument M1-1U is a 4-digit device for measuring of different kind of measuring signals such as direct voltage/direct current, temperature and frequency and a visual limit value monitoring via the display. The configuration happens via three front keys or via the optional PC-software PM-TOOL. An integrated programming interlock prevents unrequested changes of the parameter and can be released again via an individual code. The electrical connection happens on the rear side via plug-in terminals. Selectable functions like e.g. the recall of the min/max-value, Tara-function, averaging, a direct change of the limit value in operating mode and additional measuring support points for linearisation complete the concept of a modern device.
2. Assembly
Please read the Safety instructions on page 23 before installation and keep this user manual for future reference.
1. After removing the fixing elements, insert the device.
2. Check the seal to make sure it fits securely.
3. Click the fixing elements back into place and tighten the clamping screws by hand. Then use a screwdriver to tighten them another half a turn.
CAUTION! The torque should not exceed 0.1 Nm!
S
e
a
l
i
n
g
48,0
9
6
,
0
3
,
0
3
8
,
0
I
n
s
t
a
l
l
a
t
i
o
n
d
e
p
t
h
i
n
c
l
.
p
l
u
g
-
i
n
t
e
r
m
i
n
a
l
Gap for physical unit
3. Electrical connection
4
3. Electrical connection
3.2. Connection examples
Below please find some connection examples, which demonstrate some practical applications:
Type M1-1UR4A.000X.S70AD – supply 100-240 VAC, DC ±10% Type M1-1UR4A.000X.570AD – supply 230 VAC 50/60 Hz Type M1-1UR4A.000X.770AD – supply 24 VDC galv. isolated
3.2.1. Current / Voltage
2-wire sensor 4…20 mA
3.1. Terminal pin assignment
2-wire sensor 4…20 mA with external voltage source
3-wire sensor 0/4…20 mA
3-wire sensor 0/4…20 mA with external voltage source
4-20 mA
_
+
24 VDC
12 3 45 6
7
S
i
g
n
a
l
4-20 mA
_
+
24 VDC
123456
7
S
i
g
n
a
l
_
+
5
3-wire sensor 0/1/2…10 V
3-wire sensor 0-1/2…10 V
with external voltage supply
4-wire sensor 0/1/2…10 V, 50 mV
3-wire sensor 0-1/2…10 V, 50 mV
with external voltage supply
Pt100 wire
Pt1000 2-wire
3.2.2. Temperature
Thermocouple
3. Electrical connection
0-1/2...10 V
24 VDC
123456
7
S
i
g
n
a
l
1/2 V10 V
_
+
6
3. Electrical connection
Encoder with TTL-output
3.2.3. Frequency / Rotation speed
Encoder with external voltage source and TTL-output
Encoder with PNP-output
Encoder with NPN-output and required external resistance
Encoder with NPN-output
Encoder with external voltage source and NPN-output
Encoder with NPN-output and necessary external resistance
Encoder with external voltage source, NPN­output and necessary external resistance
_
+
24 VDC
12 3 45 6
7
IN
TTL
Sensor
_
+
_
+
24 VDC
123456
7
IN
PNP
Sensor
12 3 45 6 7
NPN
IN
Senso
r
_
+
24 VDC
1234567
_
+
24 VDC
NPN
Senso
r
RV
IN
Loading...
+ 19 hidden pages