Optional Fans
Optional Fan Kit
Installing the RFK3002R/3004R Fan Kit
for use with models:
B34 DV2-F
B38 DV2-F
(with RX200 NG/LP
upgrade)
C
WARNING
When installing the replace - gas lines, ttings,
accessories or any other objects cannot impede the
proper movement of the door buckles.
CAUTION
Ensure that all power to the appliance is off at the electrical breaker or fuse
before beginning installation. Ensure gas is turned off at the shutoff valve before
beginning installation.
This kit should be installed by a qualied person.
®
Check local codes and read all instructions prior to installation.
Fans
Tie-down
adhesives
with velcros
General Information
This blower kit is for installation with the models listed above.
KIT # Contents
RFK3002R 2 fans, 1 PC2, 10 screws (HW2054),
tie-down adhesives, remote control
RFK3004R 4 fans, 1 PC4, 20 screws (HW2054),
tie-down adhesives, remote control
Fans
Tie-down
adhesives
with velcros
PC2
PC4
Figure 2 Kit contents (RFK3004R).
Before You Begin
• Please read all instructions carefully
• We strongly recomment that all electrical service work be performed by a qualied electrical contractor.
• Check to ensure that all components required for installation are
included in your package.
Page 1
Figure 1
Kit contents (RFK3002R).
XT0019 - 150324
Optional Fan Kits
Install each fan motor with the blades facing the 4" round fan
opening. Attach the mounting legs by screwing into the pilot holes
around the fan opening. Spin the fan blades by hand to ensure
they don't hit the fan opening. (See Figure 2.)
Fan Motor Installation
Optional Fan Kits
Install each fan motor with the blades facing the 4" round fan
opening. Attach the mounting legs by screwing into the pilot holes
around the fan opening. Spin the fan blades by hand to ensure
they don't hit the fan opening. (See Figure 2.)
Fan Motor Installation
Figure 2. Cutaway view of control compartment showing fan
motor installation.
Pilot Holes
Mounting Legs
Access for
electrical connections
Electrical Connections
Plug each of the fan motor connectors into a quick connector on
the wire harness. See Figure 3.
Installation
1. Accessing the Control Compartment
• Flip down the lower horizontal trims of the
replace Figure 3.)
Installation
Figure 6 Fan motor connectors plugged into wire harness
connectors.
Lower horizontal trim
Figure 3
Accessing control compartment.
2. Fan Motor Installation
• Install each fan motor with the blades facing the 4" round fan
opening. Attach the mounting legs by screwing into the pilot
holes around the fan opening. Spin the fan blades by hand
to ensure they don't hit the fan opening. (See Figure 4.)
Pilot Holes
Figure 4
motor installation.
Access for
electrical connections
Cutaway view of control compartment showing fan
Mounting Legs
3. Electrical Connections
• Plug each of the fan motor connectors into a quick connector
on the wire harness.
• Connect the other end of the fan harness to control module
connection X10.
Figure 7
X10 Connection.
4. Operation
• Turn on electical power at the breaker or fuse.
• Using the remot control, turn the fans on and adjust speed
as required (follow instructsions in XG0677 - Proame 2
Operating instructions.
connector
wire harness connectorfan motor
Figure 5 Electrical Connections.
Page 2
XT0019 - 150324