Installation & Maintenance Manual
PVHEX58-300 power vent is approved for use with Montigo R320, R320-ST, R420, R420-ST, and RP620.
NOTICE
PVHEX510-300 power vent is approved for use with Montigo R520, R520-ST, R620-ST, R720, and R820.
NOTICE
PVVEX58-300 & PVVEX510-300
5/8 and 5/10 External Roof Power Vent
WARNING
If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the fire department.
PVVEX58-300 power vent is approved for use with Montigo R320, R320-ST, R420, R420-ST, and RP620.
DANGER
IF YOU SMELL GAS
NOTICE
NOTICE
Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference.
NOTICE
This power vent is approved for use with Montigo fireplaces only and is certified to ANSI Z21.50 / CSA 2.22 vented gas fireplace standard along with the fireplace.
NOTICE
PVVEX510-300 power vent is approved for use with Montigo R520, R520-ST, R620-ST, R720, and R820.
XG0518 070714
Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248
PVVEX58-300 & PVVEX510-300 Horizontal Power Vent
Safety Alert Key
Introduction
Specications
Pipe Dimensions PVVEX58-300 ...........5"/8"
Pipe Dimensions PVVEX510-300 .........5"/10"
Maximum Airow: .........................300 CFM
Speed: .......................................... 2700 RPM
Power: ...........................................Connect to replace control box
............................................ Refer to replace rating plate
Before Your Begin
General Information
This installation guide covers installation of the External Power Vent
System only. This system is designed to allow installation of gas replaces that cannot be done with a standard Direct Vent gas replace installa-
tion. Only for use on R-Series, R-Series See-Through and RP-Series.
ONLY USE WITH APPROVED FIREPLACES - see replace
installation manual.
Read through the replace's installation & maintenance manual, as it
must also be adhered to.
Power Cord Harnesses: EPVH10 - 10 foot power cord and harness EPVH20 - 20 foot power cord and harness EPVH30 - 30 foot power cord and harness EPVH40 - 40 foot power cord and harness EPVH50 - 50 foot power cord and harness EPVH60 - 60 foot power cord and harness EPVH70 - 70 foot power cord and harness EPVH80 - 80 foot power cord and harness EPVH90 - 90 foot power cord and harness EPVH100 -100 foot power cord and harness
For vent congurations and power vent locations, refer to replace manual.
Page 2
XG0518 - 070714
5"
126
8"
202
PVVEX58-300 Vertical Power Vent Termination
5"
126
8"
202
18
3 8
"
466
16
1
"
24"
610
24"
610
17"
432
17" 432
5"
126
8"
202
PVVEX58-300 Vertical Power Vent Termination
PVVEX58-300 & PVVEX510-300 Horizontal Power Vent
Introduction
PVVEX58-300 Product Dimensions
2
419
7
6
"
8
174
10
267
1 2
"
24"
610
Top View
24"
610
Side View
17"
432
17"
432
Bottom View
8"
202
5"
126
Figure 1. PVVEX58-300 & PVVEX510-300 (Tolerance ± ") [mm]
XG0518 - 070714
Page 3
PVVEX58-300 & PVVEX510-300 Horizontal Power Vent
Installation
PVVEX510-300 Vertical Power Vent Termination
24"
610
10"
253
5"
126
7
6
8
175
24"
610
1
16
"
2
419
3
18
"
8
466
"
13"
330
Figure 1a. PVVEX58-300 & PVVEX510-300 (Tolerance ± ") [mm]
Page 4
18"
458
18"
458
XG0518 - 070714
Power Vent Components
Installation
PVVEX58-300 & PVVEX510-300 Horizontal Power Vent
Installing the power vent
Power Head
Vent Clamp
Framing Box
Vent
Chase
Figure 2. Power vent components Exploded View
Step 2: Install the electrical harness (EPVH-10-100) that will com-
municate with the Power Vent. Run vent pipe from the replace to the chase. Make sure the last section is female end up and is ush with the top of the chase without going above it. See gure 2b.
Step 1: Construct a chase box around the vent penetration with
20"
Max
20"
Max
PVVEX58-300
10
270 Min
5
10
8
270
Min
5
"
8
Figure 2b. Installing the Rough-in Kit.
Step 3: Remove the last section of vent pipe and put off to the side
to be used later. Take the rough in box from the power
"
PVVEX510-300 13" [330]
24
Min
Figure 2a. Chase box dimensions
Note: Follow local and/or national code requirements for roof
clearances.
XG0518 - 070714
Figure 2c. Installing the Rough-in Kit.
Page 5
PVVEX58-300 & PVVEX510-300 Horizontal Power Vent
Installation
Step 4: Unscrew 6 screws securing the control cable cover and remove it.
Figure 2d. Unscrewing control cable cover
Step 6: Loosen nut on the strain relief of the control cable. Pass
control cable through slot in rough in box making sure the nut stays is on the opposite side of the rough in box as the strain relief.
Figure 2g.
Step 7: Push the strain relief through the hole in the roughin box.
Figure 2e. Removing control cable cover
Step 5: Unscrew 2 screws securing strain relief plate and remove it.
Strain Relief Plate
Figure 2f. Removing strain relief plate.
Page 6
Figure 2h.
Step 8: Reinstall the strain relief plate. Make sure the strain relief nut
is above the strain relief plate.
Figure 2i.
XG0518 - 070714