5/8 Inline Power
Vent with Flush
Louvered
Termination
WARNING
If the information in these instructions is not followed exactly, a fire or explosion
may result causing property damage, personal injury or death.
DANGER
IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
NOTICE
NOTICE
Installer: Leave this manual with the appliance.
Consumer: Retain this manual for future reference.
NOTICE
This power vent is approved for use with Montigo fireplaces only and is certified to
ANSI Z21.50 / CSA 2.22 vented gas fireplace standard along with the fireplace.
PVHIN58-300 and TMHIN58-40 are approved for use with Montigo R320, R320-ST,
R420, R420-ST, and RP620.
XG0521 111214
Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248
Power: ............................................ Connect to replace control box
............................................ Refer to replace rating plate
PVHIN58-300 with TMHIN48-40
Before Your Begin
General Information
This installation guide covers installation of the External Power Vent
System only. This system is designed to allow installation of gas replaces
that cannot be done with a standard Direct Vent gas replace installation.
Only for use on R-Series, R-Series See-Through and RP-Series that
uses the 5/8 venting system.
ONLY USE WITH APPROVED FIREPLACES - see replace
installation manual.
Read through the replace's installation & maintenance manual, as it
must also be adhered to.
Power Cord Harnesses:
EPVH10 - 10 foot power cord and harness
EPVH20 - 20 foot power cord and harness
EPVH30 - 30 foot power cord and harness
EPVH40 - 40 foot power cord and harness
EPVH50 - 50 foot power cord and harness
EPVH60 - 60 foot power cord and harness
EPVH70 - 70 foot power cord and harness
EPVH80 - 80 foot power cord and harness
EPVH90 - 90 foot power cord and harness
EPVH100 -100 foot power cord and harness
For vent congurations and power vent locations,
refer to replace manual.
XG0521 - 111214
Page 3
PVHIN58-300 with TMHIN58-40
861
Product Dimensions
7"
178
4"
102
559
22"
Introduction
5
27
"
8
703
8"
7
20
8
532
202
"
5"
126
5
7
"
8
193
1
23
"
591
4
23"
8"
202
584
5"
126
13"
330
7
4
"
8
124
3
3
"87
8
1"25
2"50
Figure 1 Section2. PVHIN58-300 Inline power vent unit dimensions
7"
178
14"
356
7"
178
7
33
"
8
Page 4
XG0521 - 111214
Product Dimensions
Unit Dimensions
1
39
"
4
996
9"
227
8"
202
Introduction
5
36
"
8
932
5"
126
PVHIN58-300 with TMHIN58-40
3
13
"
4
348
1
12
"
2
318
1
10
"
4
260
1
39
"
2
1003
3
12
"
8
316
7
37
"
8
963
Figure 2 Section2. TMHIN58-40 termination unit dimensions (without vanity ring)
5
41
"
8
1056
5
39
"
8
14"
356
1005
16"
406
3
"19
4
14"
354
3
2
"59
8
Figure 3 Section2. Vanity ring dimensions�
XG0521 - 111214
1
"13
2
Page 5
PVHIN58-300 with TMHIN58-40
Installing the power vent
Power Vent Clearances
Installation
Non-Combustible Zone
7' minimum
(open one side)
7
24
"
8
633
Min
This end must
be open
This end must
be open
15"
381
Min
Vent Pipe
Vent Pipe
Figure 1. Section 3 PVHIN58-300 Clearances
2"
51
Min
2"51
Min
2"51
20"
508
Min
Vent Pipe
Standard Vent
Clearances
Vent Pipe
12"
305
Min
12"
305
This end can
be closed off
This end can
be closed off
Step 1. Unpack the power vent from supplied box.
Figure 2. Section 3
Page 6
Step 2. Attach mounting feet by removing screws and tape.
Mounting Feet
Figure 3. Section 3
XG0521 - 111214
Figure 4. Section 3
PVHIN58-300 with TMHIN58-40
Installation
Step 4. See Fireplace Manual for approved vent runs. Make sure you have
the correct orientation of power vent. One end must face the replace and
one end must face the termination.
Figure 6. Section 3
Figure 5. Section 3
Step 3. Power vent cannot be installed closer than 7 feet of venting to the
appliance. This is the case whether vertical, horizontal or any combination.
Min. 7 feet of pipe between replace
and power vent
PVHIN58-300
XG0521 - 111214
Figure 7. Section 3
Page 7
PVHIN58-300 with TMHIN58-40
Installation
Step 5. Remove two screws securing electrical plate.
Figure 8. Section 3
Step 6. Remove power vent cable from inside component cover.
Step 7. Take electrical harness [EPVH-10-100] that will communicate with
the power vent, and attach the strain relief for it to the electrical plate. Tighten
the nut on the strain relief.
Figure 10. Section 3
Figure 9. Section 3
Page 8
Figure 11. Section 3
XG0521 - 111214