Installation & Maintenance Manual
PVHIN58-300 with TMHIN58-40
5/8 Inline Power Vent with Flush Louvered Termination
WARNING
If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
DANGER
IF YOU SMELL GAS
Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the fire department.
NOTICE
NOTICE
Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference.
NOTICE
This power vent is approved for use with Montigo fireplaces only and is certified to ANSI Z21.50 / CSA 2.22 vented gas fireplace standard along with the fireplace.
PVHIN58-300 and TMHIN58-40 are approved for use with Montigo R320, R320-ST, R420, R420-ST, and RP620.
XG0521 111214
Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248
PVHIN58-300 with TMHIN58-40
Table of Contents
Instruction Manual Contents
Specications � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 3
Before Your Begin � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 3
General Information � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 3
Power Cord Harnesses: � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 3
Product Dimensions � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 4
Installing the power vent � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 6
Power Vent Clearances � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 6
Conduit and Wiring Clearances � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 9
How to use Diluter Collar � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 10
How to Open and Set the Diluter Collar � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 10
Power Vent Wiring � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 11
Installing the TMHIN58-40 Termination � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 12
Termination clearances � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 12
Capacitor Replacement - REC 1257 � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 16
Motor and Capacitor Replacement - REC 1258 � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 20
Appendix A: Warranty � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 24
Appendix B: State of Massachusetts � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 25
Page 2
XG0521 - 111214
Safety Alert Key
Introduction
Specications
Pipe Dimensions PVHIN58-300 ............5"/8"
Pipe Dimensions TMHIN58-40 .............. 5"/8"
Maximum Airow: .........................300 CFM
Speed: .......................................... 2700 RPM
Power: ............................................ Connect to replace control box
............................................ Refer to replace rating plate
PVHIN58-300 with TMHIN48-40

Before Your Begin

General Information

This installation guide covers installation of the External Power Vent
System only. This system is designed to allow installation of gas replaces that cannot be done with a standard Direct Vent gas replace installation.
Only for use on R-Series, R-Series See-Through and RP-Series that uses the 5/8 venting system.
ONLY USE WITH APPROVED FIREPLACES - see replace
installation manual.
Read through the replace's installation & maintenance manual, as it
must also be adhered to.

Power Cord Harnesses:

EPVH10 - 10 foot power cord and harness EPVH20 - 20 foot power cord and harness EPVH30 - 30 foot power cord and harness EPVH40 - 40 foot power cord and harness EPVH50 - 50 foot power cord and harness EPVH60 - 60 foot power cord and harness EPVH70 - 70 foot power cord and harness EPVH80 - 80 foot power cord and harness EPVH90 - 90 foot power cord and harness EPVH100 -100 foot power cord and harness
For vent congurations and power vent locations, refer to replace manual.
XG0521 - 111214
Page 3
PVHIN58-300 with TMHIN58-40
861

Product Dimensions

7"
178
4"
102
559
22"
Introduction
5
27
"
8
703
8"
7
20
8
532
202
"
5"
126
5
7
"
8
193
1
23
"
591
4
23"
8"
202
584
5"
126
13"
330
7
4
"
8
124
3
3
"87
8
1"25
2"50
Figure 1 Section2. PVHIN58-300 Inline power vent unit dimensions
7"
178
14" 356
7"
178
7
33
"
8
Page 4
XG0521 - 111214
Product Dimensions
Unit Dimensions
1
39
"
4
996
9"
227
8"
202
Introduction
5
36
"
8
932
5"
126
PVHIN58-300 with TMHIN58-40
3
13
"
4
348
1
12
"
2
318
1
10
"
4
260
1
39
"
2
1003
3
12
"
8
316
7
37
"
8
963
Figure 2 Section2. TMHIN58-40 termination unit dimensions (without vanity ring)
5
41
"
8
1056
5
39
"
8
14"
356
1005
16"
406
3
"19
4
14"
354
3
2
"59
8
Figure 3 Section2. Vanity ring dimensions�
XG0521 - 111214
1
"13
2
Page 5
PVHIN58-300 with TMHIN58-40

Installing the power vent

Power Vent Clearances

Installation
Non-Combustible Zone
7' minimum
(open one side)
7
24
"
8 633 Min
This end must be open
This end must be open
15" 381
Min
Vent Pipe
Vent Pipe
Figure 1. Section 3 PVHIN58-300 Clearances
2"
51
Min
2"51
Min
2"51
20" 508 Min
Vent Pipe
Standard Vent Clearances
Vent Pipe
12" 305 Min
12"
305
This end can be closed off
This end can be closed off
Step 1. Unpack the power vent from supplied box.
Figure 2. Section 3
Page 6
Step 2. Attach mounting feet by removing screws and tape.
Mounting Feet
Figure 3. Section 3
XG0521 - 111214
Figure 4. Section 3
PVHIN58-300 with TMHIN58-40
Installation
Step 4. See Fireplace Manual for approved vent runs. Make sure you have
the correct orientation of power vent. One end must face the replace and
one end must face the termination.
Figure 6. Section 3
Figure 5. Section 3
Step 3. Power vent cannot be installed closer than 7 feet of venting to the
appliance. This is the case whether vertical, horizontal or any combination.
Min. 7 feet of pipe between replace
and power vent
PVHIN58-300
XG0521 - 111214
Figure 7. Section 3
Page 7
PVHIN58-300 with TMHIN58-40
Installation
Step 5. Remove two screws securing electrical plate.
Figure 8. Section 3
Step 6. Remove power vent cable from inside component cover.
Step 7. Take electrical harness [EPVH-10-100] that will communicate with
the power vent, and attach the strain relief for it to the electrical plate. Tighten the nut on the strain relief.
Figure 10. Section 3
Figure 9. Section 3
Page 8
Figure 11. Section 3
XG0521 - 111214
Loading...
+ 18 hidden pages