PVHEX510-300 power vent is approved for use with Montigo R520, R520-ST, R620-ST, R720, and R820.
NOTICE
PVHEX58-300 &
PVHEX510-300
5/8 and 5/10
External Wall
Power Vent
WARNING
If the information in these instructions is not followed exactly, a fire or explosion
may result causing property damage, personal injury or death.
DANGER
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
PVHEX58-300 power vent is approved for use with Montigo R320, R320-ST, R420,
R420-ST, and RP620.
IF YOU SMELL GAS
NOTICE
NOTICE
Installer: Leave this manual with the appliance.
Consumer: Retain this manual for future reference.
NOTICE
This power vent is approved for use with Montigo fireplaces only and is certified to
ANSI Z21.50 / CSA 2.22 vented gas fireplace standard along with the fireplace.
NOTICE
PVVEX510-300 power vent is approved for use with Montigo R520, R520-ST,
R620-ST, R720, and R820.
XG0517
Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248
Power: ............................................Connect to replace control box
............................................ Refer to replace rating plate
Before Your Begin
General Information
This installation guide covers installation of the External Power Vent
System only. This system is designed to allow installation of gas replaces
that cannot be done with a standard Direct Vent gas replace installa-
tion. Only for use on R-Series, R-Series See-Through and RP-Series.
ONLY USE WITH APPROVED FIREPLACES - see replace
installation manual.
Read through the replace's installation & maintenance manual, as it
must also be adhered to.
Power Cord Harnesses:EPVH10 - 10 foot power cord and harness
EPVH20 - 20 foot power cord and harness
EPVH30 - 30 foot power cord and harness
EPVH40 - 40 foot power cord and harness
EPVH50 - 50 foot power cord and harness
EPVH60 - 60 foot power cord and harness
EPVH70 - 70 foot power cord and harness
EPVH80 - 80 foot power cord and harness
EPVH90 - 90 foot power cord and harness
EPVH100 -100 foot power cord and harness
For vent congurations and power vent locations,
refer to replace manual.
Step 1: Unscrew Power Head from rough in Box by unscrewing four
screws.
1
"
4
Figure 2a. Unscrewing four screws
Wall board
Rough in box
Figure 2. Framing dimensions (combustible material construction)
Figure 2b.
Step 2: Remove Power head from rough in box.
Page 4
Figure 2c.
XG0517 - 070714
Installation
PVHEX58-300 & PVHEX510-300 Horizontal Power Vent
Step 3: Screw rough in box to wall.
Step 5: Remove electrical cover.
Figure 2f.
Step 6: Remove two screws securing the strain relief plate.
Figure 2d.
Step 4: Remove six screws securing the electrical cover.
Figure 2e.
Figure 2g.
Step 7: Remove Strain Relief Plate.
Figure 2h.
XG0518 - 070714
Page 5
PVHEX58-300 & PVHEX510-300 Horizontal Power Vent
Installation
Step 8: Take the electrical harness (EPVH-10-100) that will communicate with the Power vent and pass the cable through the slot in the
rough box. Make sure the nut for the strain relief is inside the box and
the strain relief is outside the box.
Figure 2i.
Step 9: Reinstall the strain relief plate underneath the strain relief nut
and screw the strain relief plate down. Then tighten strain relief nut.
Step 11: Secure the electrical cover back down with the six screws
making sure the control cable curls up safely.
Figure 2l.
Step 12: Pass the vent pipe through the rough in box so it extends
6 1/2 inches into the rough in box.
Figure 2j. Removing control cable cover
Step 10: Push the molex connector through the hole in the electrical
cover until it clicks into place.
Click
6 1/2 "
Figure 2m.
Figure 2k.
Page 6
Figure 2n.
XG0517 - 070714
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.