Installation & Maintenance Manual
PVHEX510-300 power vent is approved for use with Montigo R520, R520-ST, R620-ST, R720, and R820.
NOTICE
PVHEX58-300 & PVHEX510-300
5/8 and 5/10 External Wall Power Vent
WARNING
If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
DANGER
Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the fire department.
PVHEX58-300 power vent is approved for use with Montigo R320, R320-ST, R420, R420-ST, and RP620.
IF YOU SMELL GAS
NOTICE
NOTICE
Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference.
NOTICE
This power vent is approved for use with Montigo fireplaces only and is certified to ANSI Z21.50 / CSA 2.22 vented gas fireplace standard along with the fireplace.
NOTICE
PVVEX510-300 power vent is approved for use with Montigo R520, R520-ST, R620-ST, R720, and R820.
XG0517
Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248
070714
PVHEX58-300 Horizontal Power Vent System
Safety Alert Key
Introduction
Specications
Pipe Dimensions PVHEX58-300 ...........5"/8"
Pipe Dimensions PVHEX510-300 .........5"/10"
Maximum Airow: .........................300 CFM
Speed: .......................................... 2700 RPM
Power: ............................................Connect to replace control box
............................................ Refer to replace rating plate
Before Your Begin
General Information
This installation guide covers installation of the External Power Vent
System only. This system is designed to allow installation of gas replaces that cannot be done with a standard Direct Vent gas replace installa-
tion. Only for use on R-Series, R-Series See-Through and RP-Series.
ONLY USE WITH APPROVED FIREPLACES - see replace
installation manual.
Read through the replace's installation & maintenance manual, as it
must also be adhered to.
Power Cord Harnesses: EPVH10 - 10 foot power cord and harness EPVH20 - 20 foot power cord and harness EPVH30 - 30 foot power cord and harness EPVH40 - 40 foot power cord and harness EPVH50 - 50 foot power cord and harness EPVH60 - 60 foot power cord and harness EPVH70 - 70 foot power cord and harness EPVH80 - 80 foot power cord and harness EPVH90 - 90 foot power cord and harness EPVH100 -100 foot power cord and harness
For vent congurations and power vent locations, refer to replace manual.
Page 2
XG0517 - 070714
Product Dimensions
5"
127
8"
203
PVHEX58-300 External Horizontal Power Vent
2"51
13" 330
19
7 8
"
505
9
1 2
"
241
6
1 8
"
156
15
7 8
"
403
13"
330
13"
330
5"
127
8"
203
PVHEX58-300 External Horizontal Power Vent
Power Head
PVHEX58-300 & PVHEX510-300 Horizontal Power Vent
Introduction
1
22
"
4
566
18
465
1
"
4
1
21
"
4
541
17
439
1
"
4
1
4
"
2
114
Front View
13"
19
330
9
241
505
2"51
1
"
2
7
"
8
1
6
"
8
156
Top View
7
13"
15
"
8
PVHEX58-300
8"
203
PVHEX10-300
254
10"
Rear View
5"
127
403
Framing Kit
330
Side View
13"
330
Electrical Box
Vent Retainer
Figure 1. PVHEX58-300 & PVHEX510-300 (Tolerance ± ") [mm]
XG0517 - 070714
Page 3
PVHEX58-300 & PVHEX510-300 Horizontal Power Vent
Installation
Installing the Power vent
1
"
14
2
368
Framing
15
389
Unpacking the Power vent
Step 1: Unscrew Power Head from rough in Box by unscrewing four screws.
1
"
4
Figure 2a. Unscrewing four screws
Wall board
Rough in box
Figure 2. Framing dimensions (combustible material construction)
Figure 2b.
Step 2: Remove Power head from rough in box.
Page 4
Figure 2c.
XG0517 - 070714
Installation
PVHEX58-300 & PVHEX510-300 Horizontal Power Vent
Step 3: Screw rough in box to wall.
Step 5: Remove electrical cover.
Figure 2f.
Step 6: Remove two screws securing the strain relief plate.
Figure 2d.
Step 4: Remove six screws securing the electrical cover.
Figure 2e.
Figure 2g.
Step 7: Remove Strain Relief Plate.
Figure 2h.
XG0518 - 070714
Page 5
PVHEX58-300 & PVHEX510-300 Horizontal Power Vent
Installation
Step 8: Take the electrical harness (EPVH-10-100) that will commu­nicate with the Power vent and pass the cable through the slot in the rough box. Make sure the nut for the strain relief is inside the box and the strain relief is outside the box.
Figure 2i.
Step 9: Reinstall the strain relief plate underneath the strain relief nut
and screw the strain relief plate down. Then tighten strain relief nut.
Step 11: Secure the electrical cover back down with the six screws making sure the control cable curls up safely.
Figure 2l.
Step 12: Pass the vent pipe through the rough in box so it extends
6 1/2 inches into the rough in box.
Figure 2j. Removing control cable cover
Step 10: Push the molex connector through the hole in the electrical
cover until it clicks into place.
Click
6 1/2 "
Figure 2m.
Figure 2k.
Page 6
Figure 2n.
XG0517 - 070714