Installation & Maintenance Manual
P42DF Indoor
Prestige Series Residential Fireplace
DANGER
Read and understand this manual. Improper installation, adjustment, alteration, service or maintenance can cause serious injury, property damage or even death. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
CAUTION
Glass doors on gas fireplaces are extremely hot while the fireplace is on and remain hot even after the fireplace has been turned off. Safety screens are available and can reduce the risks of severe burns. Please keep children away from the fireplace at all times.
®
C US
WARNING
Do not store or use gasoline or any other flammable vapors and liquids in the vicinity of this or any other gas burning appliance. A fire or explosion my occur causing serious injury, property damage or even death.
NOTICE
Installer: Leave this manual with the appliance. Do not remove. Consumer: Retain this manual for maintenance and future reference. Do not Discard.
DANGER
IF YOU SMELL GAS
Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the fire department.
XG0195 030712
Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248
P42DF* Indoor Gas Fireplace
NOTICE
You must read and understand this manual prior to installation, operation or troubleshooting this appliance. Please retain this owner’s manual for furure reference and maintenance.
Table of Contents
Safety Alert Key
Introduction
Installation
Before you start
Installation Checklist ...............................................................................4
.................................................................................3
.................................................................................4
Section 1: Installation Overview and Product Dimensions .....................5
Section 2: Framing & Clearances ........................................................... 6
Framing the Fireplace .............................................................................6
Clearances .................................................................................6
Section 3: Venting .................................................................................7
Notes for Planning V
▪ Section 3-1: Converting to Rear V
▪ Section 3-2: Installing PVTK-1 ..............................................................8
▪ Section 3-2-1 Venting Layout .......................................................... 8
▪ Section 3-2-2: Venting Components ...............................................9
▪ Section 3-3: Installing Wall Mounted Direct Vent Termination ............10
▪ Section 3-3-1: V
▪ Section 3-3-2: Venting Components ..............................................14
▪ Section 3-3-3:Heat Shields ............................................................ 15
enting
......................................................................7
ent ..................................................7
enting Layout Wall Mounted Termination
........1
1-13
Section 4: Wiring ...............................................................................16
SIT - IPI W
Fan & Lights Wiring
iring
........................................................................16
................................................................16
Section 5: Installing the Gas Line .........................................................17
Section 5-1:
Section 5-2: Gas Pressure ...................................................................17
Section 5-3:
Fuel Conversion
Gas Connection
...............................................................17
...............................................................17
Section 6: Finishing ..............................................................................18
▪ Finishing
▪Fireplace Facing ............................................................................18
▪ Installing the Nailing Flange Extension ......................................... 18
Around the Fireplace
.....................................................18
Section 7: Removing the door ..............................................................19
Section 8:Installing the Accessories .....................................................20
▪ Installing the Firestones ................................................................ 20
Operation ............................................................................21
▪ For
▪ Lighting Instructions ...................................................................... 21
Your Safety - READ BEFORE LIGHTING
Turn Off Gas to Appliance
............................................................21
..............................21
Maintenance
▪ General
▪ Cleaning ...............................................................................22
▪ Replacing Light Bulbs ...................................................................23
▪ Troubleshooting ............................................................................24
▪ Replacement Parts List ................................................................24
Appendix
B. Warranty ...............................................................................26
C. State of Massachusetts. ...........................................................27
........................................................................22 - 24
...............................................................................22
A. Termination Locations
...............................................................25
Page 2
XG0195 - 030712
P42DF* Indoor Gas Fireplace
High voltage
Toxic
Flammable materials
Corrosive
Fork lift trucks
Danger overhead crane
Explosion risk
Blank
Safety Alert Key
DANGER WARNING
Indicates a hazardous situation which, if not avoided, WILL result in death or serious injury or property damage.
CAUTION NOTICE
Indicates a hazardous situation which, if not avoided, WILL result in minor or moderate injury.
Introduction
INTRODUCTION
Congratulations on your purchase of a Montigo Fireplace.
With over 30 years of experience, Montigo is committed to providing you with a gas replace that is not only a beautiful addition to your space, but that is also designed and manufactured to the highest safety, reliability and engineering standards.
We strongly encourage you to read and carefully follow the instructions laid out in this Installation, Operation and Maintenance Manual and retain it for your future reference. Pay special attention to all cautions, warnings, and notices throughout this manual intended to ensure your safety.
This manual covers installation, operation and maintenance. Lighting, operation and care of this replace can be easily performed by the homeowner. All installation and service work should be performed by a qualied or licensed installer, plumber or gas tter as certied by the state, province, region or governing body where the replace is being installed.
This installation, operation and maintenance manual is applicable to the models described to the right. Refer to your rating plate to verify included options.
WARNING
Hot glass will cause burns. Do not touch glass until unit is cooled. Never allow children to touch glass.
Indicates a hazardous situation which, if not avoided, COULD result in death or serious injury or property damage.
Address practices that are important, but not related to personal injury
MODEL
P42DFNI
P42DFLI
Natural Gas
Liquid Propane
Gas Rating
(BTU hr)
Linear Burner w/ Glass
media Accessories
X 32,000 X X
X 32,000 X X
SIT Electronic Ignition
Warranty and Installation Information: (See Appendix B)
The Montigo warranty will be voided by, and Montigo disclaims any responsibility for, the following actions:
► Modication of the replace and/or components including Direct-Vent assembly or glass doors.
► Use of any component part not manufactured or approved by Montigo in combination with this Montigo replace system.
► Installation other than as instructed in this manual.
Consult your local Gas Inspection Branch on installation requirements for factory-built gas replaces. Installation & repairs should be done by a qualied contractor.
XG0195 -030712
Page 3
P42DF* Indoor Gas Fireplace
Installation
IMPORTANT MESSAGE: SAVE THESE INSTRUCTIONS
The P42DF* Direct Vent replace must be installed in accordance with these Instructions. Carefully read all the Instructions in this manual rst. Consult the Local Gas Branch to determine the need for a permit prior to starting the installation. It is the responsibility of the installer to ensure this replace is installed in compliance with the manufacturers instructions and all applicable codes.
BEFORE YOU START:
NOTICE
Installation and repairs should be done by an authorized gas fireplace service technician. The appliance should be inspected before use and at least annually by a professional. More frequesnt cleaning may be required due to exessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and circulating air passageways of the fireplace are kept clean.
CAUTION
Due to high operating temperatures, this appliance should be located out of traffic & away from furniture and draperies. Children and adults should be alerted to the hazards of the high surface temperature, which could cause burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance. Clothing or other flammable materials should not be placed on or near the appliance.
Installation Checklist
 Determine the desired install location of your replace.  See Section 1, Dimensions on Page 5, and refer to the Framing
Section 2 for details.
 Select the location of your termination and resulting vent run.
 Your selected termination location must be the highest point
in the Direct Vent installation.
 Should it be impossible to meet the venting requirements laid
out in Section 4: Venting, please contact Montigo regarding the use of a Montigo Power Vent.
 Lay out the Vent run; calculating the required elbows and straight
runs of 5"/8" flex or rigid pipe.
 Layout Electrical Requirements Refer to Section 5: Wiring, for
Details.
 Refer to Section 6: Installing the Gas Line, for details on the
gas connection and access.
 Refer to local codes and guidelines for installation requirements.
 Installation and repairs should be done by a qualied
contractor and must conform to:
Installations in Canada must conform to the current CAN/CGA B-149.1 and .2 Gas Installation Code and local regulations.
.................
Installations in the USA must conform to local codes, or in the absence of local codes to the National Fuel Gas Code, ANSI Z223.1
.
See Appendix C for installation within the State of Massachusetts. This replace must comply with NFPA-54 Chapter 10.
DANGER
When this appliance is installed directly on any combustible material other than wood flooring, it must be installed on a metal or wood panel extending the full width and depth of the appliance or a fire will occur causing serious injury, property damage or even death.
Page 4
XG0195 - 030712
Installation
Section 1: Installation Overview and Product Dimensions
P42DF* Indoor Gas Fireplace
Please review the Installation Checklist on Page 4 for general information on preparing for a successful installation of your replace.
The P42DF* replace may be installed in any location that maintains proper clearances to air conditioning ducts, electrical wiring and plumbing. Safety, as well as efciency of operation, should be considered when
39
42"
42
selecting the replace location. Try to select a location that does not interfere with room trafc, has adequate ventilation and offers an accessible path for Direct Vent installation.
The replace dimensions are shown below:
1
6
"
4
1
"
2
3
"
4
19"
30
Front View
1
21
"
4
5"
5
34
"
8
1
27
1
"
2
"
2
Side View
8"
42"
Top View
8"
Figure 1. Fireplace dimensions, (ALL Models, shown in Table on Page 3).
XG0195 -030712
Page 5
P42DF* Indoor Gas Fireplace
Section 2: Framing & Clearances
Installation
1). Frame in the enclosure for the unit with framing materials. The
framed opening for the assembled replace is 42" wide, x 42" high x 21 1/4" deep, see Figure 2
.
NOTE: When constructing the framed opening, please ensure there is access to install the gas line when the unit is installed. See Figure 2.
0" clearance to corners only
42”
84 1/2
5
3
Noncombustible Stud
42
59 3/4”
2
4
4
/
1
1
* When sheetrock is not used behind the replace, framing depth 21 1/4" may be reduced by 5/8".
Figure 2. Framing dimensions, (Straight wall & Corner Installation).
Combustible Header
Combustible Shelf
max.
12”
RHS102
Non Combustible
Stud 1/2” Above Top
9”
N.G. & L.P.
96” MIN
12”
max.
Rear Vent
Top Vent
Min 1”
7 5/8”
g
Ceilin
Non-Combustibl Materials Only
Alcove area over Fireplac e
Non-combustible header
3”
12”
door opening
Floor
e
Figure 5. Non Combustible Framing for Top Vent or Rear Vent, with alcove.
Clearances
When installing a shelf over the top of the replaces, the following guidelines must be adhered to:
For Rear Vent applications, the minimum clearance is 0" from the insulation jacket to a wall, or any combustible materials, and 9" clearance from the top of the replace to the underside of any combustible shelf materials.
For Top Vent applications, the minimum clearance is 0" from the insulation jacket to a wall, or any combustible materials, and 17 1/2" to the underside of any combustible shelf materials.
27 1/2”
34 1/2”
42”
Figure 3. Combustible Framing for shelves over the replace, Rear vent. Note: Rear vent available for Natural Gas only.
Combustible Header
Combustible Shelf
RHS102
17 1/2”
MEL Short 90° elbow
50 1/2”
40 1/2”
Figure 4. Combustible Framing for shelves over the replace, Top vent.
* (0" clearance from insulation jacket)
MODEL
Top - Rear vent *Top - Top vent
Back *
P42DF* 9" 17 1/2" 0" 0" 0" 4"
Sides *
Floor
Mantel
Page 6
XG0195 - 030712
Installation
Section 3: Venting
Montigo supplies a variety of direct venting and termination options.
The direct vent termination location MUST be selected such that it is the highest point in the venting assembly. It should also be
selected such that it provides the shortest vent run possible. Should it be impossible to ensure that the termination is the highest point or to meet the venting guidelines laid out below please contact your Montigo dealer to discuss power venting options.
NOTES FOR PLANNING VENTING:
Venting can originate from the unit through the top or through the rear Venting can terminate through the roof or through an exterior wall. Refer to Appendix A - Termination Locations to ensure the planned
termination location is acceptable. Once the termination location has been established, refer to the
appropriate section below for installation details All replaces shipped from the factory are Top vent.
See Section 3-1 for converting the unit from top vent to rear vent.
P42DF* Indoor Gas Fireplace
Flue Cover Plate
Flue Gasket
8” Outer Flue Collar
5” Inner Flue Collar
Figure 7. Flue cover and collar installation, Rear Vented replace.
Section 3-1: CONVERTING TO REAR VENT
Use the following instructions to convert an P42DF* for Rear Vent use:
1. Remove the Rear ue cover and gasket (5" and 8") on the ue outlet, as shown in Figure 7.
2. Next, Remove the Top ue collar's (5" and 8") on the ue outlet, as shown in Figure 7.
3. Install the (removed) Rear ue cover and gasket material, to the Top vent outlet. Fasten the cover with included hardware, as illustrated Figure 8.
4. Install the (5" and 8") collars to the rear vent outlet using the included hardware, as illustrated Figure 8.
5” Inner Flue Collar
8” Outer Flue Collar
Flue Gasket
Flue Cover Plate
Figure 6. Flue cover and collar removal, Top Vented replace.
XG0195 -030712
Page 7
3
P42DF* Indoor Gas Fireplace
Installation
Section 3-2: INSTALLING A ROOF MOUNTED
DIRECT VENT TERMINATION (PVTK-1)
This section applies to installations where the direct vent termi­nation will be roof mounted.
Section 3-2-1: VENTING LAYOUT
Selection of components and details of venting lay out should adhere to the following guidelines:
 The maximum termination point is 32’ above the replace (NOTE:
if the maximum termination height is used, the ame pattern may be affected).
 The Vertical termination must be a minimum 2’ higher than where
the termination exits the roong materials, (asphalt shingles, cedar shakes, etc). This distance should be measured from the high side of the roof slope where the ue ashing intersects the roong materials. (see Figures 8 to 8c *).
 Termination location must be a minimum 6’ from a mechanical
air inlet.
 Termination location must be a minimum 18” from a parapet wall.  A maximum of two offsets (each offset is made up of 2-90°
bends) may be made.
 Install a restop at any location where venting passes through
combustible materials and construction.
 Utilize support straps, or support plates, and rings (as required)
to meet acceptable building practices.
 Install all roof ashing and storm collars as shown.
PVTK1 Termination
2’ min.
Support ring
32’ max.
Obstacle
Support plate
Firestop
Figure 8a. Top vent, Roof mounted with 1 offset (1 offset= two 90° bends).
PVTK1 Termination
2’ min.
Support straps or support plate & ring
Roof mounted Terminations
The following details are some possible congurations for Roof mounted
Firestop
terminations. See below.
2’ max
PVTK1 Termination
2’ min.
Support ring
32’ max.
Figure 8. Top vent, Roof mounted termination with no offset in vent run.
Support plate
Firestop
Figure 8b. Top vent, Roof mounted with 2 offsets (1 offset= two 90° bends).
Obstacle
2’
Support plate & ring
Firestop
Firestop
Page 8
XG0195 - 030712
Installation
P42DF* Indoor Gas Fireplace
PVTK1 Termination
PEXT Sections
Support plate
Support ring
12”
Max.
32’ max
Figure 8c. Rear vent, Roof mounted venting (1 = 90° bend).
Section 3-2-2: VENTING COMPONENTS
Select from the following components and associated Montigo part numbers for installation of a Roof Mounted Termination. Use only Montigo Vent Components. Use of non-Montigo parts will void the warranty and may impede operation of the replace.
Connection and installation of the vent components should adhere to the following guidelines:
 Use any combination of rigid and Flex pipe as required.  Flex sections may be stretched up to 50% of their total length
(e.g. a 24” section maybe stretched to 36”).
 Connect all vent sections using a minimum of three sheet
metal screws on the outer pipe ue.
 Ensure the pipe ends male to female slide in a minimum of
1 1/2” of overlap.
 Ensure all runs are supported with a minimum of 3 supports
per 10’ of venting.
 When hanging/ supporting venting, ensure that 1” clearance
is maintained on sides and bottom of vent runs and 2” above horizontal vent runs to any combustible material.
 Ensure when cutting sections of rigid pipe to maintain integrity
of internal supports.
 Place the springs, supplied with the pipe kit, between the
outer and inner pipes to keep the pipes separate and avoid any possible hot spots.
 Montigo recommends the use of a ex section for the nal pipe
connected directly to the replace offering greater exibility of installation and absorption of movement.
 When penetrating a combustible ceiling, a ceiling restop
must be used.
 Montigo recommends that all exterior corners and joints be
sealed with exterior caulking however we encourage you to consult your Building Envelope Engineer or Waterproong Consultant for further recommendations.
A - Termination PVTK-1
B - Flex Sections PFL - 1 (12" f/f Section)
PFL - 18 (18" f/f Section) PFL - 2 (24" f/f Section) PFL - 3 (36" f/f Section) PFL - 4 (48" f/f Section) PFL - 6 (72" f/f Section)
C - Rigid Sections PXT - 5 (5" f/f Section)
PXT - 10 (10" f/f Section) PEXT - 1 (12" f/f Section) PXT - 20 (20" f/f Section) PEXT - 2 (24" m/f Section) PEXT - 3 (36" m/f Section) PEXT - 4 (48" m/f Section) PEXT - 6 (72" m/f Section)
D - Support Ring & Plate
E - Firestop PS-8
F - Roof Flashing PRF-7 (1/12 - 7/12 pt.)
XG0195 -030712
PSPXT-8
PRF-12 (7/12 - 12/12 pt.)
Page 9