tion, service or maintenance can cause
injury or property damage. Refer to
this manual. For assistance or additional
information consult a qualied installer,
service agency or the gas supplier.
For Your Safety:
Do not store or use gasoline
or other ammable vapors
and liquids in the vicinity of
this or any other appliance.
What To Do If You Smell Gas:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call the re department.
A. Termination Locations .............................................. 19
CAUTIONS
Due to its high operating temperatures, the appliance
should be located out of traffic & away from furniture and
draperies.
Children and adults should be alerted to the hazards
of the high surface temperature, which could cause
burns or clothing ignition.
Young children should be carefully supervised when
they are in the same room as the appliance.
Clothing or other flammable materials should not be
placed on or near the appliance.
Introduction
About the modular fireplaces and the ME34-DV-2 Homefire:
The ME34-DV-2 includes a 21,000 BTU dual burner, 5 piece logset,
and glowing embers. All M34 Series Modular Fireplaces allow quick
and easy upgrades in the future. The ME34-DV-2 can be upgraded
to a 25,000 BTU Homefire Plus burner. Contact your dealer for more
information. The ME34-DV-2 model is available in four versions:
The ME34-DV-2 is certified as a Vented Gas Fireplace Heater
(ANSI Z21.88-2000 · CSA 2.33-2000) and is rated for:
Natural Gas 21,000 BTU/H (7.6 Kilowatts) Maximum Input
17,500 BTU/H (5.1 Kilowatts) Minimum Input
Propane21,000 BTU/H (7.6 Kilowatts) Maximum Input
17,500 BTU/H (5.1 Kilowatts) Minimum Input
How to use this manual:
This manual covers installation, operation and maintenance. Lighting, operation and care of this fireplace can be easily performed by
the homeowner. However, all installation and service work should be
performed by a qualified or licensed installer, plumber, or gasfitter
who is qualified or licensed by the state, province, region, or governing body in which the appliance is being installed.
This manual covers all models and unless otherwise specified, the
designation ME34-DV-2 refers to all models. Sections which are
specific to a particular model are marked with a symbol,
plus the appropriate model number.
Warranty and Installation Information:
The Montigo warranty will be voided by, and Montigo disclaims any
responsibility for, the following actions:
Modification of the fireplace and/or components including Direct-
Vent assembly or glass doors.
Use of any component part not manufactured or approved by
Montigo in combination with this Montigo fireplace system.
Installation other than as instructed in this manual.
Consult your local Gas Inspection Branch on installation requirements for factory-built gas fireplaces. Installation & repairs should be
done by a qualified contractor.
Installations in Canada must conform to the current CAN/CGA
B-149.1 and .2 Gas Installation Code and local regulations. If the
optional air-circulating fan kit is installed, it must be electrically
grounded in accordance with CSA C22.1 Canadian Electrical Code
Part 1 and/or Local Codes.
Installations in the USA must conform to local codes, or in the
absense of local codes to the National Fuel Gas Code, ANSI Z223.1-1988. If the optional air-circulating fan is installed, it must be
grounded in accordance with local codes or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70-1987.
Page 2
Part No. XG0105B
Installation
15
26 1/8
32
Ø7
Ø4
34
C
15
31 1/2
Ø7
Ø4
8 3/4
33
15 3/4
36
2
2
1
/
4
0
"
c
l
e
a
r
a
n
c
e
t
o
c
o
r
n
e
r
s
o
n
l
y
4
2
3
3
5
9
3
/
8
Installing The Fireplace Shell
The fireplace may be installed in any location that maintains proper
clearances to air conditioning ducts, electrical wiring and plumbing.
Safety, as well as efficiency of operation, must be considered when
selecting the fireplace location. Try to select a location that does not
interfere with room traffic, has adequate ventilation, and offers an
accessible pathway for Direct Vent installation. Refer to page 4 - Vent Installation for more information.
The fireplace dimensions are shown below:
Top Vent
ME34-DV-2 Homefire
Framing
* When sheetrock
is not used behind
the fireplace, framing depth may be
reduced to 15"
Figure 2. Framing dimensions.
Front View
Figure 1. Fireplace dimensions.
Clearances
The ME34-DV-2 clearances to combustible materials are:
Top - Rear Vent* 7"
Top - Top Vent*† 35"
Rear Vent
Figure 3. Corner framing dimensions.
When installing a shelf over the top of the fireplace, the following
guidelines must be adhered to: For Rear Vent models (ME34DR-2),
the minimum clearance from the top of the fireplace to a shelf is 7".
For Top Vent models (ME34DT-2), the minimum clearance when using the CRS30 is 15". (Minimum 1" clearance must still be maintained around the vent pipes.)
Back 0"
Side 1"
Floor 0"
Mantle** 10"
* Clearance from the top of the fireplace to a combusti-
ble ceiling within the fireplace enclosure.
** Refer to page 11.
† If the standard elbow (MEL90) is used with the Low
Clearance Sleeve (CRS30) the Top Clearance is 15".
If the Low Clearance Sleeve (CRS30) is NOT used
over the elbow, the Top Clearance is 35".
Rear Vent
Top Vent
Figure 4. Framing for shelves over the fireplace.
Unprotected combustible walls which are perpendicular to the
fireplace opening, must not project beyond the shaded area shown in
Figure 19b.
For protection against freezing temperatures, it is recommended that
outer walls of the chase be insulated with a vapour barrier. This will
reduce the possibility of a cold-air convection current on the fireplace.
Part No. XG0105B
When this appliance is installed directly on carpeting, tile or any
combustible material other than wood flooring, it must be installed
on a metal or wood panel extending the full width and depth of
the appliance.
WARNING:
Page 3
ME34-DV-2 Homefire
Installation
Installing The Gas Line
The gas line must be installed before finishing the ME34-DV-2 Fireplace. Natural Gas requires a minimum inlet gas supply pressure of
5.5" W.C. & a manifold pressure of 3.5" W.C. Propane Gas requires a
minimum inlet gas supply pressure of 11" W.C. & a manifold pressure
of 10" W.C. Provision must also be made for a 1/8" N.P.T. plugged
tapping and be accessible for test gauge connection immediately
upstream of the gas supply controls to the appliance. The fireplace
gas connection and the main operating gas valve is located behind
the removable brass trim at the bottom of the unit and need only be
attached to the gas line with an approved fitting, as required by the
applicable installation codes.
• Only use gas shut-off valves approved for use by the state, province,
region, or governing body, in which the appliance is being installed, or
as required by the applicable installation codes.
• Flexible gas connectors must not exceed 3 feet in length, unless it is
allowable within applicable installation codes.
Figure 5. Gas line access.
During any pressure testing of the gas supply piping that excedes 1/2
psig (3.5 kPa), the appliance and its individual shutoff valve must be
disconnected from gas supply system.
When pressure testing the gas supply piping system at test pressures
of less than or equal to 1/2 psig (3.5 kPa), the appliance must be
isolated from the gas supply piping system by closing its individual
manual shutoff valve.
Vent Installation
This section covers the installation of direct venting and terminations.
Installation Requirements
ME34-DV-2 fireplaces are certified for use with Montigo Standard
Series (4" / 7") venting components
Minimum 1" clearance to combustibles required for vent pipes
Use only certified Montigo vent components. (Use of other parts
will void the Montigo warranty, and may impede the operation of
the fireplace.)
All joints must be secured with a minimum of two screws per joint
Vent terminations must not be recessed in walls or siding
Horizontal runs must be supported by a minimum of two supports
per horizontal run. A minimum of one screw on each side of support is also required
Flex vent sections may be stretched up to 50% of their total length
(eg. a 24" section may be stretched to 36")
Maximum horizontal run for a flex section with no vertical rise is 3
feet.
Flex vent sections over 3 feet must fall within the limits set by the
venting graph and must have a minimum vertical rise of 3 inches
per foot of flex.
Solid vent sections may be cut less than half way from the tapered
end
Venting components can be used in any combination of solid/rigid
pipe or flex pipe and in any orientation (Male connectors can face
in any direction)
Vent Terminations
Selecting A Termination Location
Choosing your vent termination location will help to determine
whether you need to use a top vent or rear vent fireplace. Figure 6,
Note: After gas line is connected, each appliance connection,
valve and valve train must be checked while under normal
operating pressure with either a liquid solution, or leak
detection device, to locate any source of leak. Tighten
any areas where bubbling appears or leak is detected until
bubbling stops completely or leak is no longer detected.
DO NOT use a flame of any kind to test for leaks.
Installing The Remote Switch
The ME34-DV-2's gas valve, located behind the lower brass trim, may
be connected to a wall switch. The valve generates its own power.
This is a millivolt circuit. Use only low voltage wire, and DO NOT
connect any external power to it.
Refer to Figure 28 for wiring requirements.
Note: The switch location must not exceed 30' from the fireplace.
Page 4
Figure 6a. Fireplace locations and vent terminations.
Cautions:
Vent terminations can be very hot. If the termination is less
than 7 feet above a public walkway, it should be fitted with a
certified Montigo Heat Guard. (Part no. MTKOG)
Do not obstruct, or attempt to conceal, the vent termination.
These actions will affect the operation of the fireplace, and
may be hazardous.
In heavy snow areas, take extra care to prevent snow buildup
from obstructing the vent termination.
Part No. XG0105B
Installation
12
12
11
11
1212
12
ME34-DV-2 Homefire
Installing Terminations with Built-In Frames
MTO-3F
1. Frame the termination opening to 11" x 11".
2. Fasten the termination to the studs using a minimum of 4
screws.
Installing Terminations with MSR Frames
MSR
Installing Heat Guards over Terminations
MTKOG
1. Ensure that the two long mounting brackets are facing the bot-
tom of the termination. (See inset). This will provide more heat
protection at the top of the termination, where temperatures are
highest.
2. Attach to the faceplate of the termination using four sheet metal
screws.
MTO-3
1. Frame the termination opening to 12" x 12".
2. Fasten the termination to the studs using a minimum of 4 screws.
Installing Terminations with MOSR Frames
MOSR
MTO-3
1. Frame the termination opening to 12" x 12".
2. Fasten the MOSR frame to the interior side of the studs using a
minimum of 4 screws.
3. Insert the termination into the MOSR frame as shown here, and
attach by screwing through the four pilot holes in the termination.
Part No. XG0105B
Page 5
ME34-DV-2 Homefire
0
1
2
2
4
3
6
4
8
6
0
7
2
8
4
9
6
1
0
8
1
3
2
1
2
0
1
4
4
1
5
6
1
6
8
1
8
0
H
o
r
i
z
o
n
t
a
l
R
u
n
(
i
n
.
)
H
e
a
r
t
h
0
1
2
2
4
3
6
4
8
6
0
7
2
8
4
9
6
1
0
8
Installation
Top Vent Venting Runs
For the ME34-DV-2 Top Vent, there are two types of installations: A)
Through-The-Wall Installations and B) Vertical (Through-The-Roof)
Installations.
A) Through-The-Wall Installations
Before you install any venting, you must determine whether the
venting run will be acceptable. Unacceptable venting can affect the
fireplace's combustion.
The Venting Graph
Measure the vertical height from the fireplace hearth to the centre of
the termination and the horizontal run from the from the fireplace flue
collar to the wall flange of the termination. Plot on the Venting Graph
(Fig. 7) with an 'X'.
If the 'X' falls on or above the top boundary of the shaded area, the
installation is acceptable.
Example A: (Acceptable Installation)
If the vertical dimension from the hearth is 84" and the
horizontal run to the wall flange of the vent termination
is 36", this would be an acceptable installation.
Example B: (Acceptable Installation)
If the vertical dimension from the hearth is 90" and the
horizontal run to the wall flange of the vent termination
is 126", this would be an acceptable installation.
Example C: (Unacceptable Installation)
If the vertical dimension from the floor of the fireplace is
78" and the horizontal run to the wall flange of the vent
termination is 108", this would NOT be an accept-
able installation.
Top Vent
Heat Shields
Due to high flue temperatures, heat shields
are required on all 34 Series Modular Direct
Vent installations (except those with vertical
terminations) at the point where the venting
connects to the termination. With the heat
shield, vent clearances can be maintained
at 1".
Figure 8. Heat Shield. Install by sliding over the vent pipe where it
passes through combustible construction.
Available Top Vent Components
The following venting components are available for the ME34-DV-2
Top Vent:
A - Termination MTO-3 (3" length)
MTO-3F (3" length)
B - Stucco Kits MSR (stucco frame)
MOSR (stucco can)
BSR (brick can)
D - Flex sections MFL-1 (12" section)
MFL-18 (18" section)
MFL-2 (24" section)
MFL-3 (36" section)
MFL-4 (48" section)
E - Solid sections EXT-18 (18" f/f section)
MEXT-1 (12" m/f section)
MEXT-2 (24" m/f section)
MEXT-3 (36" m/f section)
MEXT-4 (48" m/f section)
F - Elbows
MEL-90FM (f/m 90° elbow)
EEL-45 (f/m 45° elbow)
MEL-90M (m/m 90° elbow)
MEL-90F (f/f 90° elbow)
NOTES: All dimension lengths for vertical or horizontal runs are
measured from center of the vent pipe.
Figure 7. ME34-DV-2 Top Vent Venting Graph
Page 6
Venting runs must fall within the limits set by the vent-
ing graph (see Figure 7).
Part No. XG0105B