Montigo LDVPV47 User Manual

High voltage
Toxic
Flammable materials
Corrosive
Fork lift trucks
Danger overhead crane
Explosion risk
Blank
High voltage
Toxic
Flammable materials
Corrosive
Fork lift trucks
Danger overhead crane
Explosion risk
Blank
High voltage
Toxic
Flammable materials
Corrosive
Fork lift trucks
Danger overhead crane
Explosion risk
Blank
High voltage
Toxic
Flammable materials
Corrosive
Fork lift trucks
Danger overhead crane
Explosion risk
Blank
Installation & Maintenance Manual
LDVPV47
LDVPV Linear Power Vent System
DANGER
Read and understand this manual. Improper installation, adjustment, alteration, service or maintenance can cause serious injury, property damage or even death. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
WARNING
Do not store or use gasoline or any other flammable vapors and liquids in the vicinity of this or any other gas burning appliance. A fire or explosion my occur causing serious injury, property damage or even death.
®
C US
CAUTION
Glass doors on gas fireplaces are extremely hot while the fireplace is on and remain hot even after the fireplace has been turned off. Safety screens are available and can reduce the risks of severe burns. Please keep children away from the fireplace at all times.
NOTICE
Installer: Leave this manual with the appliance. Do not remove. Consumer: Retain this manual for maintenance and future reference. Do not Discard.
DANGER
IF YOU SMELL GAS
Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the fire department.
XG0750 112911
Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248
LDVPV47 Linear Power Vent System
DANGER WARNING
Safety Alert Key
Indicates a hazardous situation which, if not avoided, WILL result in death or serious injury or property damage.
CAUTION NOTICE
Indicates a hazardous situation which, if not avoided, WILL result in minor or moderate injury.
Table of Contents
Safety Alert Key .................................................................................2
Introduction .................................................................................3
Before you Start .................................................................................3
Section 1: Installation .......................................................................4 - 9
Unit Dimensions .................................................................................4
Installation of Pipe Diluter ........................................................................5
Installation of Pipe Reducer & Diluter ......................................................5
Flush Vent Option .................................................................................6
Installation for Horizontal Venting ............................................................7
Installation for Horizontal Downward Vent ..............................................8
Installing the Vertical Linear Power Vent .................................................8
Installing the Horizontal Linear Power Vent .............................................8
Mounting of Linear Power Vent ..............................................................9
Wiring Installation ................................................................................. 9
Wiring Schematic ...............................................................................10
Parts List ............................................................................... 11
Appendix
A. Termination Locations ...............................................................12
B. Warranty ...............................................................................13
C. State of Massachusetts. ...........................................................14
Indicates a hazardous situation which, if not avoided, COULD result in death or serious injury or property damage.
Address practices that are important, but not related to personal injury
Page 2
XG00750 - 112911
LDVPV47 Linear Power Vent System
NOTICE
You must read and understand this manual prior to installation, operation or troubleshooting this appliance. Please retain this owner’s manual for furure reference and maintenance.
Introduction
Selecting and Installing the Fireplace
The Linear Power Vent System must only be used with a Montigo Direct Vent Fireplace. When selecting a gas replace for use with the Linear Power Vent System, take into consideration the various requirements and limitations in the venting installation section of the Model's manual:
Models Must Be Equipped with Electronic Ignition
(HSI/IPI)
Only models equipped with an electronic ignition system may be installed with the Linear Power Vent System. This system allows for greater exibility on venting requirements. For example downward vertical vent runs are possible with an HSI/IPI system, as outlined in the Venting Section.
All replaces with 5"/8" venting must be reduced to 4"/7" venting in order to be used with the Linear Power Vent System.
General Information
This installation guide covers installation of the Linear Power Vent System only. This system is designed to allow installation of gas replaces that cannot be done with a standard Direct Vent gas replace installation.
Specications and instructions pertaining to your chosen replace must be followed. Please read this Installation Operation and Maintenance Instructions carefully before operating this equipment.
Standard Series (4"/7" dia.) Termination System: LDVPV47 - Linear Power Vent System Pre/Post Purge Control Box
RHSIT05 -Control module, provides pre/post purge. (HSI System) ECB-007 Post Purge control box (IPI System) Power Cord Harnesses: LPVH10 -10 foot power cord and harness LPVH20 -20 foot power cord and harness LPVH30 -30 foot power cord and harness LPVH40 -40 foot power cord and harness LPVH50 -50 foot power cord and harness LPVH60 -60 foot power cord and harness LPVH70 -70 foot power cord and harness LPVH80 -80 foot power cord and harness
CAUTION
Ensure perforated air holes in the new pipe adapter / restrictor are not covered when installing new pipe connection.
Before You Begin
 Minimum clearances of 1" from vent to all combustible materials
must be maintained.
 The LDVPV must only be installed with Montigo venting
components. The LDVPV may be used with any of the available Montigo terminations.
 In order to maintain the power vent system integrity all 4"
and 7" venting connections must be fastened with three self tapping screws.
 Installation of the LDVPV must comply with this manual, and be
completed by a qualied professional.
 Plan the layout of the installation's venting run before starting
the installation.
 The MAXIMUM total allowable length; Refer to Linear Power
Vent Installation Section, Page 4-6.
 Downward venting is allowable. Please refer to Page 5 for a
table and illustrations regarding the limitations of this type of installation.
 Minimum length of straight pipe between the Fireplace and the
Power Vent is: 2 feet
 Access / Service Panel, must maintain 1" clearance. Minimum
30% free air must be supplied to the motor.
 Disconnect the power supply when installing and/or
servicing the replace or the power vent system.
CAUTIO N
When cold air enters warm building interiors, primarily at the air intake end, condensation may occur on the exterior of the flex pipe. To limit condensation, install insulation over the last 20 feet of flex pipe. Sloping the last 20 - 0 feet of flex pipe downward to the exterior of the building may also aid in eliminating condensation. Ensure the termination is securly fastened and is sealed to the flex pipe. Fasten the termination to building exterior with water tight sealant and appropriate fasteners.
CAUTION
Due to high operating temperatures, this appliance should be located out of traffic & away from furniture and draperies. Children and adults should be alerted to the hazards of the high surface temperature, which could cause burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance. Clothing or other flammable materials should not be placed on or near the appliance.
XG0750 - 112911
Page 3
LDVPV47 Linear Power Vent System
Installation
27 15/16"
16 5/16"
10 1/16"
4
7
2 6
1.0
2 7/16"
33 3/4"
14 7/16"
16 7/16"
1 5/16"
1.0
FAN SHIELD
Page 4
Figure 1. LDVPV47 Linear Power Vent dimensions.
XG0750 - 112911
LDVPV47 Linear Power Vent System
Installation
CAUTION
Ensure perforated air holes in the new pipe adapter / diluter are not covered
when installing the new pipe connection.
Section:
Installation of Pipe Diluter
The Installation of the LDV Air Circulator Pipe Reducer on your replace: Model No's. that use 4" /7" Vent
1. Install the Pipe Diluter as shown below.
Fllue Diluter Collar
Slide Reducer over 4" Flue Adapter
Top of Fireplace
Existing 4" Flue Adapter
Figure 2a. Installation of 4" / 7" Flue Reducer.
See page 11 for detailed part numbers.
Installation of Pipe Reducer & Diluter
The Installation of the LDV Air Circulator Pipe Reducer on your replace: Model No's. that use 5" /8" Vent
1. Install the Pipe Reducer & Diluter as shown below.
8" to 7" Reducer
Flue Reducer / Diluter
Slide Reducer/ Diluter over 4" Flue Adapter
Top of Fireplace
Existing 4" Flue Adapter
Figure 2b. Installation of 5"/8" Flue Reducer.
See page 11 for detailed part numbers.
XG0750 -112911
Venting Installation
The Internal Power Vent must be installed with a gas replace equipped with an electronic ignition system. When installing the venting, the installation must adhere to the Venting Installation Section in the replace's Installation Operation and Maintenance Instructions, as well as the following guidelines:
 Ensure that the planned termination location is acceptable as
shown in Appendix A.
 Minimum of 2 feet of straight pipe before the power vent.
Page 5
Loading...