Montigo L38DF-ST, LS38DF-ST, L38FSDN, L38FSDNE, L38FSDNI Maintance Manual

...
www.montigo.com
Installation Operation & Maintenance Manual
Check local codes and read all instructions prior to installation.
L38DF-ST
L38DF-ST Series Gas Fireplace
LS38DF-ST
L38DF ST Manual
Warning: If the infor-
mation in these instructions is not followed exactly, a re or explosion
L42DF-ST Shown
Warning:
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualied installer, service agency or the gas supplier.
Safety Notice:
Glass doors on gas replaces are extremely hot while the replace is on and remain hot even after the replace has been turned off. Safety screens are available and can reduce the risks of severe burns. Please keep children away from the replace at all times.
For Your Safety:
Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other appliance.
C US
XG0810 Canadian Heating Products Inc. Langley, BC V4W 4A Montigo Del Ray Corp. Ferndale, WA 98248 081310-1
may result causing property dam­age, personal injury or death.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the re department.
Installation and service must be performed by a qualied installer, service agency or the gas supplier.
• Installer: Leave this manual with the appliance.
• Consumer: Retain this manual for future reference.
L38DF-ST* Indoor Gas Fireplace
Read this manual before installing, operating or troubleshooting this appliance.
Please retain this owner's manual for future reference.
Table of Contents
Safety Alert Key
Introduction ............................................................................... 3
Models............................................................................3
Installation
Before you Start ............................................................. 4
Installation Checklist ...................................................... 4
Section 1: Installation Overview and Product Dimensions ......5
Section 2: Framing the Fireplace ............................................. 6
Clearances ........................................................ 6
Section 3: The Direct Vent System ................................... 7 - 11
Section 3-1: Converting from Top Vent to Rear Vent ....7
Section 3-2: Installing a Roof mounted Termination 8 - 9
▪ Roof mounted Terminations
Standard Top Vent (no elbows or offsets)............. 8
Top Vent (two elbows one offset) ......................... 8
Top Vent (multi-elbows and offsets) ..................... 8
Section 3-2-2: Venting Components ............................. 9
Section 3-3: Installing a Wall mounted Termination ....10
Standard PTO Installation ....................................10
Installing MOSR Frame ....................................... 10
Top Vent, Wall mounted termination (one elbow) .... 11
Top Vent, Wall mounted termination (multi elbow) ... 11
Rear Vent, Wall mounted Termination Graph .........13
Standard Rear Vent, (no elbows or offsets) ........... 13
Rear Vent, Wall mounted termination (two elbows) . 13
Section 3-3-2: Venting Components ..............................14
Section 3-2-1: Venting Layout ...................................... 8
Standard Roof Vent (one elbows no offsets) ....... 9
Pre-installed MSR Frame .................................... 10
Pre-installed BSR Frame ..................................... 10
Installing VSS Termination Shield ......................... 10
Installing PTKOG Heat Guard .............................. 10
Section 3-3-1: Venting Layout ............................ 11 - 12
Top Vent, Wall mounted Graph, L38DF-ST ............ 11
Section 3-3-3: Heat Shields ......................................... 15
Warning:
Installing a RHS8 Wall Mounted Heat Shield ......... 15
Section 4: Wiring ................................................................... 16
SIT - IPI gas control and pilot ............................... 16
Installing HFK Fan Kit ......................................... 16
Section 5: Installing the Gas Line .......................................... 17
Section 5-1: Fuel Conversion ........................................ 17
Section 5-2:
Section 5-3:
Section 6: Finishing ............................................................... 18
Finishing around the replace .................................. 18
Installing the nailing ange extension ........................ 18
Section 7: Installing and Removing the Door ........................ 19
Section 8: Installing the Accessories ..................................... 20
Installing the L38DF-ST Firestones ...........................20
Section 9: Operation ....................................................... 21 - 23
Start-up Sequence Honeywell Gas valve ..................22
Start-up Sequence SIT-IPI Gas valve ....................... 23
Maintenance ................................................................... 24 - 25
▪ SIT Hi-Lo Burner Adjustment ................................... 24
▪ SIT Pilot Burner Adjustment .................................... 24
Troubleshooting ...................................................... 25
SIT- Nova 820
Honeywell Gas Control Valve ........................... 25
SIT- IPI Electronic
Parts List ............................................................... 25
Appendix
B. Warranty ............................................................ 27
Installing a RHS101 Wall Mounted Heat Shield ...... 15
Honeywell gas control and pilot ........................... 16
Gas Pressure ............................................ 17
Gas Connection......................................... 17
Installing the L38DF-ST Articial River Rocks ............ 20
Start-up Sequence with Continuous Pilot .................. 21
General ................................................................. 24
Cleaning ................................................................ 24
Gas Control Valve ....................... 25
Gas Control Valve ................. 25
A. Termination Locations .......................................... 26
C. State of Massachusetts. ......................................28
Page 2
Part No. XG0810 - 081310-1
Introduction
Safety Alert Key:
L38DF-ST* Indoor Gas Fireplace
• WARNING!
Indicates a hazardous situation which, if not avoided could result in death or serious injury.
• CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
• NOTICE: Used to address practices not related to personal injury.
• Important: Used to address practices not related to personal injury.
INTRODUCTION
Congratulations on your purchase of a Montigo Fireplace.
With over 30 years of experience, Montigo is committed to providing you with a gas replace that is not only a beautiful addition to your space, but that is also designed and manufactured to the highest safety, reliability and engineering standards.
We strongly encourage you to read and carefully follow the instructions laid out in this Installation, Operation and Maintenance Manual and retain it for your future reference. Pay special attention to all cautions, warnings, and notices throughout this manual intended to ensure your safety.
This manual covers installation, operation and maintenance. Lighting, operation and care of this replace can be easily performed by the homeowner. All installation and service work should be performed by a qualied or licensed installer, plumber or gastter as certied by the state, province, region or governing body where the replace is being installed.
This installation, operation and maintenance manual is applicable to the models described below. Refer to your rating plate to verify included options. Throughout this manual instructions are applicable to all models designated as L38DF-ST* unless otherwise noted.
MODEL
L38FSDN X 27,000 X X
L38FSDNE X 27,000 X X
L38FSDNI X 27,000 X X
L38FSDL X 27,000 X X
L38FSDLE X 27,000 X X
Natural Gas
Liquid Propane
Gas Rating
(BTU hr)
Linear Burner w/
Glass Accessories
Standard Pilot
Ignition
Honeywell Hot
Surface Ignition
SIT Electronic
Ignition
WARNING
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
Part No. XG0810 - 081310-1
L38FSDLI X 27,000 X X
NOTE: L(S)38DF-ST* Units are stainless steel construction
Warranty and Installation Information: (See Appendix B)
The Montigo warranty will be voided by, and Montigo disclaims any responsibility for, the following actions:
► Modication of the replace and/or components including Direct­Vent assembly or glass doors.
► Use of any component part not manufactured or approved by Montigo in combination with this Montigo replace system.
► Installation other than as instructed in this manual.
Consult your local Gas Inspection Branch on installation requirements for factory-built gas replaces. Installation & repairs should be done by a qualied contractor.
Page 3
L38DF-ST* Indoor Gas Fireplace
Installation
IMPORTANT MESSAGE: SAVE THESE INSTRUCTIONS
The L38DF-ST* Direct Vent replace must be installed in accordance with these Instructions. Carefully read all the Instructions in this manual rst. Consult the Local Gas Branch to determine the need for a permit prior to starting the installation. It is the responsibility of the installer to ensure this replace is installed in compliance with the manufacturers instructions and all applicable codes.
BEFORE YOU START:
INSTALLATION AND REPAIRS SHOULD BE DONE BY AN AUTHORIZED SERVICE TECHNICIAN. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE TECHNICIAN. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, ETC. IT IS IMPERATIVE THAT CONTROL COMPARTMENTS, BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE FIREPLACE ARE KEPT CLEAN.
CAUTION!
Due to its high operating temperatures, the appliance should be located out of trafc & away from furniture and draperies.
Children and adults should be alerted to the hazards
of the high surface temperature, which could cause burns or clothing ignition.
Young children should be carefully supervised when
they are in the same room as the appliance.
Clothing or other ammable materials should not be
placed on or near the appliance.
Installation Checklist
 Determine the desired install location of your replace.
 See Section 1, Dimensions on Page 5, and refer to the Framing
Section 2 for details.
 Select the location of your termination and resulting vent run.
 Your selected termination location must be the highest point
in the Direct Vent installation.
 Should it be impossible to meet the venting requirements laid
out in Section 3: Venting, please contact Montigo regarding the use of a Montigo Power Vent.
 Lay out the Vent run; calculating the required elbows and straight
runs of 4"/7" flex or rigid pipe.
 Layout Electrical Requirements Refer to Section 4: Wiring, for
Details.
 Refer to Section 5: Installing the Gas Line, for details on the
gas connection and access.
 Refer to local codes and guidelines for installation requirements.
 Installation and repairs should be done by a qualied
contractor and must conform to:
Installations in Canada must conform to the current CAN/CGA B-149.1 and .2 Gas Installation Code and local regulations.
Installations in the USA must conform to local codes, or in the absence of local codes to the National Fuel Gas Code, ANSI Z223.1-1988
See Appendix C for installation within the State of Massachusetts. This replace must comply with NFPA-54 Chapter
10.
.
WARNING!
When this appliance is installed directly on any combustible material other than wood ooring, it must be installed on a metal or wood panel extending the full width and depth of the appliance.
Page 4
Part No. XG0810 - 081310-1
L38DF-ST* Indoor Gas Fireplace
g
2
Installation
Section 1: Installation Overview and Product Dimensions
Please review the Installation Checklist on Page 4 for general information on preparing for a successful installation of your replace.
The L38DF-ST* replace may be installed in any location that maintains proper clearances to air conditioning ducts, electrical wiring and plumb­ing. Safety, as well as efciency of operation, should be considered when selecting the replace location. Try to select a location that does not interfere with room trafc, has adequate ventilation and offers an accessible path for Direct Vent installation.
The replace dimensions are shown below:
7”
8”
24”
5”
36 3/8”
37 3/4”
Top View
9 1/2”
1 1/4”
1”
5”
24”
8”
35 1/4” Opening
37 3/4”
1 1/4”1 1/4”
5 1/2”
18 3/4” Openin
5 1/4”
LH-Side View
Front View
Figure 1. Fireplace dimensions, (ALL Models, shown in Table on Page 3).
33 3/4”
26 3/4”
Part No. XG0810 - 081310-1
Page 5
L38DF-ST* Indoor Gas Fireplace
-
Section 2: Framing
Installation
1). Frame in the enclosure for the unit with framing materials. The
framed opening for the assembled replace is 41" wide, x 40" high x 23 3/4" deep, see Figure 2
.
NOTE: When constructing the framed opening, please ensure there is access to install the gas line when the unit is installed. See Figure 22.
41”
34 1/2”
Notes: Install supplied metal header (Part No#L38ST060) above replace after unit is in place. Use supplied hardware to fasten to framing. Both sides Typi­cal. Unit may not be exactly as shown.
40”
40”
Both walls Typical.May not be exactly as shown.
23 3/4”
Figure 2. Framing dimensions.
Supplied shield
Combustible Shelf
3” Min.
N.G. & L.P
17 1/2”
PEL Short 90 elbow
39 1/2” Min.
Min.
Figure 4. Combustible Framing for shelves over the replace, Top
vent.
Top vent
N.G. & L.P
Alcove over
7”
door
opening
Fireplace Non
Combustible Materials Only
Non Combustible Header
10”
29 1/2”
Combustible
Header
Supplied Header
40”
34 1/2”
Min. 1”
7”
Backframe Min. 37 3/4”
Figure 2a. Framing dimensions, (Back-framing)
Supplied shield
12” Max. 3” Min.
N.G. & L.P
26 3/4
Combustible Shelf
10”
Min.
Figure 3. Combustible Framing for shelves over the replace, Rear
vent.
Floor
Figure 5. Non Combustible Framing with alcove above replace, Right side. Combustible Framing above replace, Left side, see gure 2. (Top Vent).
Clearances
When installing a shelf over the top of the replaces, the following guidelines must be adhered to:
For Rear Vent applications, the minimum clearance is 3" from the rear of the replace to a wall, or any combustible materials, and 10" clearance from the top of the replace to the underside of any combutible shelf materials.
For Top Vent applications, the minimum clearance is 3" from the rear of the replace to a wall, or any combustible materials, and 17 1/2" to the underside of any combutible shelf materials.
MODEL
L38DF-ST 10" 17 1/2" 3" 1" 0" 4"
Top - Rear Vent *
Top - Top Vent
Back
Sides
Floor
Mantel
Page 6
Part No. XG0810 - 081310-1
Section 3: Venting
L38DF-ST* Indoor Gas Fireplace
Installation
Montigo supplies a variety of direct venting and termination options.
The direct vent termination location MUST be selected such that it is the highest point in the venting assembly. It should also be
selected such that it provides the shortest vent run possible. Should it be impossible to ensure that the termination is the highest point or to meet the venting guidelines laid out below please contact your Montigo dealer to discuss power venting options.
NOTES FOR PLANNING VENTING:
 Venting can originate from the unit through the top or
through the rear
 Venting can terminate through the roof or through an
exterior wall.
 Refer to Appendix A - Termination Locations to ensure the
planned termination location is acceptable.
 Once the termination location has been established, refer
to the appropriate section below for installation details
 All replaces shipped from the factory are Top vent.
See Section 3-1 for converting the unit from top vent to rear vent.
4. Install the (5" and 8") collars to the rear vent outlet using the included hardware, as illustrated Figure 8.
8” Outer Flue Cover Plate
5” Inner Flue Cover Plate
8” Outer Flue Collar
5” Inner Flue Collar
Figure 8. Flue cover and collar installation, Rear Vented replace.
Section 3-1: CONVERTING TO REAR VENT
Use the following instructions to convert an L38DF-ST* for Rear Vent use:
1. Remove the Rear ue cover and gasket (5" and 8") on the ue outlet, as shown in Figure 7.
2. Next, Remove the Top ue collar's (5" and 8") on the ue outlet, as shown in Figure 7.
3. Install the (removed) Rear ue cover and gasket material, to the Top vent outlet. Fasten the cover with included hardware, as illustrated Figure 8.
Flue Collar
8” Outer Flue Collar
5” Inner Flue Cover Plate
Outer Flue
r Plate
Figure 7. Flue cover and collar removal, Top Vented replace.
Part No. XG0810 - 081310-1
Page 7
L38DF-ST* Indoor Gas Fireplace
Installation
Section 3-2: INSTALLING A ROOF MOUNTED DIRECT VENT
TERMINATION (PVTK-1) This section applies to installations where the direct vent termi­nation will be roof mounted.
Section 3-2-1: VENTING LAYOUT
Selection of components and details of venting lay out should adhere to the following guidelines:
 The maximum termination point is 32’ above the replace (NOTE:
if the maximum termination height is used, the ame pattern may be affected).
 The Vertical termination must be a minimum 2’ higher than where
the termination exits the roong materials, (asphault shingles, cedar shakes, etc). This distance should be measured from the high side of the roof slope where the ue ashing intersects the roong materials. (see Figures 11 to 11c *).
 Termination location must be a minimum 6’ from a mechanical
air inlet.
 Termination location must be a minimum 18” from a parapet wall.
 A maximum of two offsets (each offset is made up of 2-90°
bends) may be made.
 Install a restop at any location where venting passes through
combustible materials and construction.
 Utilize support straps, or support plates, and rings (as required)
to meet acceptable building practices.
 Install all roof ashing and storm collars as shown.
PVTK1 Termination
Figure 11a. Top vent, Roof mounted with 1 offset (1 offset= two 90°
bends).
PVTK1 Termination
Roof mounted Terminations
The following details are some possible congurations for Roof mounted terminations. See below.
PVTK1 Termination
Figure 11. Top vent, Roof mounted termination with no offset in
vent run.
Figure 11b. Top vent, Roof mounted with 2 offsets (1 offset= two 90°
bends).
Page 8
Part No. XG0810 - 081310-1
Installation
L38DF-ST* Indoor Gas Fireplace
PVTK1 Termination
PEXT Solid Sectio
12” Max.
n
Figure 11c. Rear vent, Roof mounted venting (1 = 90° bend).
Section 3-2-2: VENTING COMPONENTS
Select from the following components and associated Montigo part numbers for installation of a Roof Mounted Termination. Use only Montigo Vent Components. Use of non-Montigo parts will void the warranty and may impede operation of the replace.
A - Termination PVTK-1
B - Flex Sections PFL - 1 (12" f/f Section)
PFL - 18 (18" f/f Section) PFL - 2 (24" f/f Section) PFL - 3 (36" f/f Section) PFL - 4 (48" f/f Section) PFL - 6 (72" f/f Section)
C - Rigid Sections PXT - 5 (5" f/f Section)
PXT - 10 (10" f/f Section) PEXT - 1 (12" f/f Section) PXT - 20 (20" f/f Section) PEXT - 2 (24" m/f Section) PEXT - 3 (36" m/f Section) PEXT - 4 (48" m/f Section) PEXT - 6 (72" m/f Section)
D - Support Ring & Plate
E - Firestop PS-8
PSPXT-8
Connection and installation of the vent components should adhere to the following guidelines:
 Use any combination of rigid and Flex pipe as required.
 Flex sections may be stretched up to 50% of their total length
(e.g. a 24” section maybe stretched to 36”).
 Connect all vent sections using a minimum of three sheet
metal screws on the outer pipe ue.
 Ensure the pipe ends male to female slide in a minimum of
1 1/2” of overlap.
 Ensure all runs are supported with a minimum of 3 supports
per 10’ of venting.
 When hanging/ supporting venting, ensure that 1” clearance
is maintained on sides and bottom of vent runs and 2” above horizontal vent runs to any combustible material.
 Ensure when cutting sections of rigid pipe to maintain integrity
of internal supports.
 Place the springs, supplied with the pipe kit, between the
outer and inner pipes to keep the pipes separate and avoid any possible hot spots.
 Montigo recommends the use of a ex section for the nal pipe
connected directly to the replace offering greater exibility of installation and absorption of movement.
 When penetrating a combustible ceiling, a ceiling restop
must be used.
 Montigo recommends that all exterior corners and joints be
sealed with exterior caulking however we encourage you to consult your Building Envelope Engineer or Waterproong Consultant for further recommendations.
F - Roof Flashing PRF-7 (1/12 - 7/12 pt.)
PRF-12 (7/12 - 12/12 pt.)
Part No. XG0810 - 081310-1
Page 9