Montigo L38DFN, L38DFNI, L38DFL, L38DFLI Maintance Manual

Installation & Maintenance Manual
High voltage
Toxic
Flammable materials
Corrosive
Fork lift trucks
Danger overhead crane
Explosion risk
Blank
High voltage
Toxic
Flammable materials
Corrosive
Fork lift trucks
Danger overhead crane
Explosion risk
Blank
High voltage
Toxic
Flammable materials
Corrosive
Fork lift trucks
Danger overhead crane
Explosion risk
Blank
High voltage
Toxic
Flammable materials
Corrosive
Fork lift trucks
Danger overhead crane
Explosion risk
Blank
L38DF Indoor
L-Series Residential Fireplace
DANGER
CAUTION
Glass doors on gas fireplaces are extremely hot while the fireplace is on and remain hot even after the fireplace has been turned off. Safety screens are available and can reduce the risks of severe burns. Please keep children away from the fireplace at all times.
®
WARNING
Do not store or use gasoline or any other flammable vapors and liquids in the vicinity of this or any other gas burning appliance. A fire or explosion my occur causing serious injury, property damage or even death.
NOTICE
Installer: Leave this manual with the appliance. Do not remove. Consumer: Retain this manual for maintenance and future reference. Do not Discard.
DANGER
IF YOU SMELL GAS
Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the fire department.
C US
XG0180 053111
Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248
L38DF* Indoor Gas Fireplace
Warning:
NOTICE
You must read and understand this manual prior to installation, operation or troubleshooting this appliance. Please retain this owner’s manual for furure reference and maintenance.
Table of Contents
Safety Alert Key
Introduction .................................................................................3
Installation
Before you Start .................................................................................4
Installation Checklist ...............................................................................4
Section 1: Installation Overview and Product Dimensions
Section 2: Framing the Fireplace
Clearances .................................................................................6
Section 3: The Direct Vent System
Converting from Top Vent to Rear Vent ...................................................7
Installing a Roof mounted Termination ...............................................8 - 9
Venting Layout ................................................................................. 8
Roof mounted Terminations
Standard Top Vent (no elbows or offsets) .................................. 8
Top Vent (two elbows one offset) ............................................... 8
Top Vent (multi-elbows and offsets) ........................................... 8
Standard Roof Vent (one elbows no offsets) .............................9
Venting Components ..........................................................................9
Installing a Wall mounted Termination ................................................... 10
Standard PTO Installation ........................................................10
Pre-installed MSR Frame .........................................................10
Pre-installed BSR Frame .........................................................10
Installing MOSR Frame ............................................................10
Installing VSS Termination Shield ............................................10
Installing PTKOG Heat Guard ..................................................10
Venting Layout ........................................................................ 11 - 12
Top Vent, Wall mounted Graph, L38DF ................................... 11
Top Vent, Wall mounted termination (one elbow) .....................11
Top Vent, Wall mounted termination (multi elbow) ................... 11
Top Vent, Wall mounted termination (45° corner) ....................12
Top Vent, Wall mounted termination (-45° corner) ...................12
Rear Vent, Wall mounted Termination Graph ...........................13
Standard Rear Vent, (no elbows or offsets) .............................13
Rear Vent, Wall mounted termination (two elbows) .................13
...............................................................6
......................................................7 - 11
.........................5
Venting Components ........................................................................14
Heat Shields ...............................................................................15
Installing a RHS8 Wall Mounted Heat Shield ...........................15
Installing a RHS101 Wall Mounted Heat Shield .......................15
Section 4:
SIT - IPI gas control and pilot ...................................................16
Installing HFK Fan Kit ..............................................................16
Section 5: Installing the Gas Line
Fuel Conversion ...............................................................................17
Gas Pressure ...............................................................................17
Gas Connection ...............................................................................17
Section 6:
Finishing around the replace ..................................................18
Installing the nailing ange extension ......................................18
Section 7: Installing and Removing the Door
Section 8: Installing the Accessories
Installing the L38DF Firestones ...............................................20
Installing the L38DF Articial River Rocks ...............................20
Section 9:
Start-up Sequence with Continuous Pilot ................................21
Start-up Sequence SIT-IPI Gas valve ......................................23
Maintenance
General ...............................................................................24
Cleaning ...............................................................................24
SIT Hi-Lo Burner Adjustment ...................................................24
SIT Pilot Burner Adjustment .....................................................24
Troubleshooting ...................................................................25
SIT- Nova 820 Gas Control Valve ............................................25
SIT- IPI Electronic Gas Control Valve ......................................25
Parts List ..............................................................................25
Appendix
A. Termination Locations ..........................................................26
B. Warranty ..............................................................................27
C. State of Massachusetts. ......................................................28
Wiring ............................................................................... 16
.............................................................17
Finishing ...............................................................................18
...........................................19
........................................................ 20
Operation ........................................................................21 - 23
........................................................................24 - 25
Page 2
XG0180 - 053111
L38DF* Indoor Gas Fireplace
High voltage
Toxic
Flammable materials
Corrosive
Fork lift trucks
Danger overhead crane
Explosion risk
Blank
Safety Alert Key
DANGER WARNING
Indicates a hazardous situation which, if not avoided, WILL result in death or serious injury or property damage.
CAUTION NOTICE
Indicates a hazardous situation which, if not avoided, WILL result in minor or moderate injury.
Introduction
INTRODUCTION
Congratulations on your purchase of a Montigo Fireplace.
With over 30 years of experience, Montigo is committed to providing you with a gas replace that is not only a beautiful addition to your space, but that is also designed and manufactured to the highest safety, reliability and engineering standards.
We strongly encourage you to read and carefully follow the instructions laid out in this Installation, Operation and Maintenance Manual and retain it for your future reference. Pay special attention to all cautions, warnings, and notices throughout this manual intended to ensure your safety.
This manual covers installation, operation and maintenance. Lighting, operation and care of this replace can be easily performed by the homeowner. All installation and service work should be performed by a qualied or licensed installer, plumber or gas tter as certied by the state, province, region or governing body where the replace is being installed.
This installation, operation and maintenance manual is applicable to the models described to the right. Refer to your rating plate to verify included options.
WARNING
Hot glass will cause burns. Do not touch glass until unit is cooled. Never allow children to touch glass.
Indicates a hazardous situation which, if not avoided, COULD result in death or serious injury or property damage.
Address practices that are important, but not related to personal injury
MODEL
L38DFN
L38DFNI
L38DFL
L38DFLI
Natural Gas
Liquid Propane
Gas Rating
(BTU hr)
Traditional Burner /
Logset
Contemporary Burner
w/ River rock
Linear Burner w/ Glass
media Accessories
Standing Pilot Ignition
Honeywell HSI Ignition
X 25,000 X X
X 25,000 X X
X 25,000 X X
X 25,000 X X
Warranty and Installation Information: (See Appendix B)
The Montigo warranty will be voided by, and Montigo disclaims any responsibility for, the following actions:
► Modication of the replace and/or components including Direct-Vent assembly or glass doors.
► Use of any component part not manufactured or approved by Montigo in combination with this Montigo replace system.
► Installation other than as instructed in this manual.
Consult your local Gas Inspection Branch on installation requirements for factory-built gas replaces. Installation & repairs should be done by a qualied contractor.
SIT Electronic Ignition
XG0180 - 053111
Page 3
L38DF* Indoor Gas Fireplace
Installation and repairs should be done by an authorized gas fireplace service technician. The appliance should be inspected before use and at least annually by a professional. More frequesnt cleaning may be required due to exessive lint from carpeting, bedding material, ect. It is imperative that control compartments, burners and circulating air passageways of
Installation
IMPORTANT MESSAGE: SAVE THESE INSTRUCTIONS
The L38DF* Direct Vent replace must be installed in accordance with these Instructions. Carefully read all the Instructions in this manual rst. Consult the Local Gas Branch to determine the need for a permit prior to starting the installation. It is the responsibility of the installer to ensure this replace is installed in compliance with the manufacturers instructions and all applicable codes.
BEFORE YOU START:
NOTICE
the fireplace are kept clean.
CAUTION
Due to high operating temperatures, this appliance should be located out of traffic & away from furniture and draperies. Children and adults should be alerted to the hazards of the high surface temperature, which could cause burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance. Clothing or other flammable materials should not be placed on or near the appliance.
Installation Checklist
 Determine the desired install location of your replace.  See Section 1, Dimensions on Page 5, and refer to the Framing
Section 2 for details.
 Select the location of your termination and resulting vent run.
 Your selected termination location must be the highest point
in the Direct Vent installation.
 Should it be impossible to meet the venting requirements laid
out in Section 3: Venting, please contact Montigo regarding the use of a Montigo Power Vent.
 Lay out the Vent run; calculating the required elbows and straight
runs of 5"/8" flex or rigid pipe.
 Layout Electrical Requirements Refer to Section 4: Wiring, for
Details.
 Refer to Section 5: Installing the Gas Line, for details on the
gas connection and access.
 Refer to local codes and guidelines for installation requirements.
 Installation and repairs should be done by a qualied
contractor and must conform to:
Installations in Canada must conform to the current CAN/ CGA B-149.1 and .2 Gas Installation Code and local regulations.
Installations in the USA must conform to local codes, or in the absence of local codes to the National Fuel Gas Code, ANSI Z223./ NFPA-54
.
See Appendix C for installation within the State of Massachusetts. This replace must comply with NFPA-54 Chapter 10.
DANGER
When this appliance is installed directly on any combustible material other than wood flooring, it must be installed on a metal or wood panel extending the full width and depth of the appliance or a fire will occur causing serious injury, property damage or even death.
Page 4
XG0180 - 053111
L38DF* Indoor Gas Fireplace
2
Installation
Section 1: Installation Overview and Product Dimensions
Please review the Installation Checklist on Page 4 for general information on preparing for a successful installation of your replace.
The L38DF* replace may be installed in any location that maintains proper clearances to air conditioning ducts, electrical wiring and plumbing. Safety, as well as efciency of operation, should be considered when
35¾"
11½"
5"
8"
37¾"
Top View
35¼" (Opening)
1¼"
selecting the replace location. Try to select a location that does not interfere with room trafc, has adequate ventilation and offers an accessible path for Direct Vent installation.
The replace dimensions are shown below:
1¼"1¼"
6¼"
18¼"
8"
5"
9½"
18"
(Opening)
1"
5¼"
37¾"
29"
21¾"
Front View Side View
Figure 1. Fireplace dimensions, (ALL Models, shown in Table on Page 3).
XG0180 - 053111
Page 5
L38DF* Indoor Gas Fireplace
Sides
Floor
Mantel
0”
RHS8 Heat Shield
PTO Termination
36” Min
46” Min.
Models Included
L38DFN
L38DFL
Models Included
L38DFN I
L38DFLI
Unacceptable vent run within shaded area.
Acceptable vent run within non-shaded area.
A
C
B
L38DF
9”
MODEL
Top - Rear Vent *
Top - Top Vent
Back
Sides
17
1
2
/
”2
Floor
Mantel
0”
1” 4”
MIN 84” to 96”
Non- combustible header
12”
6”
door opening
3”
Rear Vent
Min 1”
Ceiling
Floor
Alcove
area over Fireplace
Top Vent
2” min. 18” max.
MIN 84” to 96”
12”
6”
door opening
3”
Rear Vent
Cieling
Floor
Alcove area over Fireplace
Top Vent
N.G. & L.P.
18”
max.
1”
min.
Non-combustible header
Min 1”
REAR VENT N.G ONLY
35”
MEL Short 90° elbow
35 1/4”
17 1/2”
Combustible Header
Combustible Shelf
1” min.
RHS8 Heat Shield
PTO Termination
36” Min
46” Min.
Unacceptable vent run within shaded area.
Acceptable vent run within non-shaded area.
A
C
B
42” NG
36” LP
36
35” NG & LP
RHS8 Heat Shield
36” Min
Sides
Floor
Mantel
0”
1” 4”
MIN 84” to 96”
12”
6”
door opening
3”
Rear Vent
Cieling
Floor
Alcove area over Fireplace
Top Vent
N.G. & L.P.
18”
max.
1”
min.
Non-combustible header
Min 1”
REAR VENT N.G ONLY
RHS8 Heat Shield
PTO Termination
36” Min
46” Min.
Models Included
L38DFN
L38DFL
Models Included
L38DFN I
L38DFLI
Unacceptable vent run within shaded area.
Acceptable vent run within non-shaded area.
A
C
B
42” NG
36” LP
36
35” NG & LP
RHS8 Heat Shield
36” Min
Section 2: Framing
Installation
1). Frame in the enclosure for the unit with framing materials. The
framed opening for the assembled replace is 37 3/4" wide, x 35 1/4" high x 20 1/8" deep, see Figure 2
NOTE: When constructing the framed opening, please ensure there is access to install the gas line when the unit is installed. See Figure 2.
Figure 2. Framing dimensions, (Straight wall & Corner
Installation).
Figure 3. Combustible Framing for shelves over the replace, Rear vent. Note: Rear vent available for Natural Gas only.
37 3/4”
35 1/4”
1”
12”
REAR VENT N.G ONLY
21 3/4”
MEL Short 90° elbow
35”
.
54 1/4”
1/8”
20
* When sheetrock is not used behind the replace, framing depth 20 1/8" may be
Combustible Header
Combustible Shelf
min. max.
Combustible Header
Combustible Shelf
1” min.
reduced by 5/8".
9”
29”
17 1/2”
35 1/4”
35 1/4”
0" clearance to corners only
37 3/4
75
Figure 5. Non Combustible Framing for Top Vent or Rear Vent, with alcove. Note: Straight through the wall rear
vent available for Natural Gas only.
Clearances
When installing a shelf over the top of the replaces, the following guidelines must be adhered to:
For Rear Vent applications, the minimum clearance is 2" from the rear of the replace to a wall, or any combustible materials, and 9" clearance from the top of the replace to the underside of any combustible shelf materials.
For Top Vent applications, the minimum clearance is 2" from the rear of the replace to a wall, or any combustible materials, and 17 1/2" to the underside of any combustible shelf materials.
(Minimum 2" clearance must still be maintained around the vent pipes.)
N.G. & L.P.
min.
1”
max.
18”
MIN 84” to
Rear
96”
Vent
REAR VENT N.G ONLY
Top Vent
Min 1”
6”
Cieling
Alcove area over Fireplace
Non-combustible header
3”
12”
door opening
Floor
MODEL
Top - Rear vent *Top - Top vent
Back
Sides
Floor
L38DF* 9" 17 1/2" 1" 1" 0" 4"
Mantel
Figure 4. Combustible Framing for shelves over the replace,
Top vent.
Page 6
XG0180 - 053111
Installation
L38DF* Indoor Gas Fireplace
Section 3: Venting
Montigo supplies a variety of direct venting and termination options.
The direct vent termination location MUST be selected such that it is the highest point in the venting assembly. It should also be
selected such that it provides the shortest vent run possible. Should it be impossible to ensure that the termination is the highest point or to meet the venting guidelines laid out below please contact your Montigo dealer to discuss power venting options.
NOTES FOR PLANNING VENTING:
Venting can originate from the unit through the top or through the rear Venting can terminate through the roof or through an exterior wall. Refer to Appendix A - Termination Locations to ensure the planned
termination location is acceptable. Once the termination location has been established, refer to the
appropriate section below for installation details All replaces shipped from the factory are Top vent.
See Section 3-1 for converting the unit from top vent to rear vent.
included hardware, as illustrated Figure 8.
Flue Cover Plate
Flue Gasket
8” Outer Flue Collar
5” Inner Flue Collar
Figure 8. Flue cover and collar installation, Rear Vented replace.
Section 3-1: CONVERTING TO REAR VENT
Use the following instructions to convert an L38DF* for Rear Vent use:
1. Remove the Rear ue cover and gasket (5" and 8") on the ue outlet, as shown in Figure 7.
2. Next, Remove the Top ue collar's (5" and 8") on the ue outlet, as shown in Figure 7.
3. Install the (removed) Rear ue cover and gasket material, to the Top vent outlet. Fasten the cover with included hardware, as illustrated Figure 8.
4. Install the (5" and 8") collars to the rear vent outlet using the
5” Inner Flue Collar
8” Outer Flue Collar
Flue Gasket
Flue Cover Plate
Figure 7. Flue cover and collar removal, Top Vented replace.
XG0180 - 053111
Page 7
L38DF* Indoor Gas Fireplace
3
Installation
Section 3-2: INSTALLING A ROOF MOUNTED
DIRECT VENT TERMINATION (PVTK-1)
This section applies to installations where the direct vent termi­nation will be roof mounted.
Section 3-2-1: VENTING LAYOUT
Selection of components and details of venting lay out should adhere to the following guidelines:
 The maximum termination point is 32’ above the replace (NOTE:
if the maximum termination height is used, the ame pattern may be affected).
 The Vertical termination must be a minimum 2’ higher than where
the termination exits the roong materials, (asphalt shingles, cedar shakes, etc). This distance should be measured from the high side of the roof slope where the ue ashing intersects the roong materials. (see Figures 11 to 11c *).
 Termination location must be a minimum 6’ from a mechanical
air inlet.
 Termination location must be a minimum 18” from a parapet wall.  A maximum of two offsets (each offset is made up of 2-90°
bends) may be made.
 Install a restop at any location where venting passes through
combustible materials and construction.
 Utilize support straps, or support plates, and rings (as required)
to meet acceptable building practices.
 Install all roof ashing and storm collars as shown.
PVTK1 Termination
2’ min.
Support ring
32’ max.
Obstacle
Support plate
Firestop
Figure 11a. Top vent, Roof mounted with 1 offset (1 offset= two 90° bends).
PVTK1 Termination
2’ min.
Support straps or support plate & ring
Roof mounted Terminations
The following details are some possible congurations for Roof mounted
Firestop
terminations. See below.
2’ max
PVTK1 Termination
2’ min.
Support ring
32’ max.
Figure 11. Top vent, Roof mounted termination with no offset in vent run.
Support plate
Firestop
Figure 11b.
bends).
Top vent, Roof mounted with 2 offsets (1 offset= two 90°
Obstacle
2’
Support plate & ring
Firestop
Firestop
Page 8
XG0180 - 053111
Installation
L38DF* Indoor Gas Fireplace
PVTK1 Termination
PEXT Sections
Support plate
Support ring
12”
Max.
32’ max
Figure 11c. Rear vent, Roof mounted venting (1 = 90° bend).
Section 3-2-2: VENTING COMPONENTS
Select from the following components and associated Montigo part numbers for installation of a Roof Mounted Termination. Use only Montigo Vent Components. Use of non-Montigo parts will void the warranty and may impede operation of the replace.
Connection and installation of the vent components should adhere to the following guidelines:
 Use any combination of rigid and Flex pipe as required.  Flex sections may be stretched up to 50% of their total length
(e.g. a 24” section maybe stretched to 36”).
 Connect all vent sections using a minimum of three sheet
metal screws on the outer pipe ue.
 Ensure the pipe ends male to female slide in a minimum of
1 1/2” of overlap.
 Ensure all runs are supported with a minimum of 3 supports
per 10’ of venting.
 When hanging/ supporting venting, ensure that 1” clearance
is maintained on sides and bottom of vent runs and 2” above horizontal vent runs to any combustible material.
 Ensure when cutting sections of rigid pipe to maintain integrity
of internal supports.
 Place the springs, supplied with the pipe kit, between the
outer and inner pipes to keep the pipes separate and avoid any possible hot spots.
 Montigo recommends the use of a ex section for the nal pipe
connected directly to the replace offering greater exibility of installation and absorption of movement.
 When penetrating a combustible ceiling, a ceiling restop
must be used.
 Montigo recommends that all exterior corners and joints be
sealed with exterior caulking however we encourage you to consult your Building Envelope Engineer or Waterproong Consultant for further recommendations.
A - Termination PVTK-1
B - Flex Sections PFL - 1 (12" f/f Section)
PFL - 18 (18" f/f Section) PFL - 2 (24" f/f Section) PFL - 3 (36" f/f Section) PFL - 4 (48" f/f Section) PFL - 6 (72" f/f Section)
C - Rigid Sections PXT - 5 (5" f/f Section)
PXT - 10 (10" f/f Section) PEXT - 1 (12" f/f Section) PXT - 20 (20" f/f Section) PEXT - 2 (24" m/f Section) PEXT - 3 (36" m/f Section) PEXT - 4 (48" m/f Section) PEXT - 6 (72" m/f Section)
D - Support Ring & Plate
E - Firestop PS-8
F - Roof Flashing PRF-7 (1/12 - 7/12 pt.)
XG0180 - 053111
PSPXT-8
PRF-12 (7/12 - 12/12 pt.)
Page 9