Montigo IOSK6 User Manual

Indoor / Outdoor Sealing Kit For R620 ST
Thursday, December 02, 2010 1:33:16 PM
Use this instruction in conjuction with unit instruction manual (Doc. XG0773)
Follow the instructions for the unit installation in the up to Step 1 on Page 7 of the installation guide. The unit is in place with the screws removed as illustrated there.
Installation Instruction Kit Part No. IOSK6
IOSK6-A02
IOSK6-A03
18.79 21.80
IOSK6-A01
Figure 1: Indoor/ Outdoor Sealing Kit Ccmponents
STEP 1: Back frame the unit with the metal header supplied by Montigo above the unit and either combustible or non-combustible framing to the sides and bottom maintaining clearances as shown and ensuring the gallvanized apron (Fig 1, Part No. 620-482) can be attached to the framing.
620-482
Figure 3: Attach galvanized apron to unit
Figure 4: Install silicone gasket
STEP 4: Attach the stainless steel frame (Fig. 1, Part No. IOSK6-A01) to the galvanized frame lining up the holes around perimeter. Secure in place through holes across the top and down the sides. Do not secure the bottom ange.
STEP 5: Apply approved waterproong membrane over the ange of the frame on the top and sides and under the ange of the frame at the bottom. The membrane should overlap the frame approximately 2" around the perimeter.
Figure 2: Backframe unit CLEARANCE TO COMBUSTIBLES: 6" Top, 3" each side, 3" bottom from the protruding window box.
STEP 2: Place the galvanized apron and attach to the unit using the 6 screws removed from the unit face, Figure 3.
STEP 3: Install the silicon gasket material (supplied by Montigo) in one continuous strip with the joint at the bottom, Figure 4.
STEP 6: All facing materials may now be installed over the frame. BE CERTAIN TO MAINTAIN 6" ABOVE AND 3" ON SIDES AND BOTTOM TO ANY COMBUSTIBLE MATERIAL STEP 7: Mount the framed glass (Fig 1, IOSK6-A02) onto the unit and secure in place rst with only the two side screws.
STEP 8: Place the Galvanized strips (4 supplied) at each corner lining up screw holes and secure both the strips and the framed glass to the unit.
STEP 9: Attach the stainless steel trim (Fig1, IOSK6-A03), by placing it on and ensuring the magnets catch the previously placed galvanized strip.
ISOMETRIC VIEW
(NTS)
IOSK6-A03
IOSK6-A02
IOSK6-A01
PART NUMBER
DESCRIPTION
QTY. REV.
1
620-482
BACK PLATE, IOSK6
1
A
2
IOSK6-A01
OUTER FRAME, IOSK6
1
A
3
IOSK6-A02
DOOR ASSEMBLY, IOSK6
1
A
4
IOSK6-A03
DOOR TRIM ASSEMBLY, IOSK6
1
A
IOSK 620 Instructions Cont'd
85.25
30.12 18.79 21.80
2.90
73.92
76.94