Montigo IOSK5 User Manual

Indoor / Outdoor Sealing Kit For R520 ST Use this instruction in conjuction with unit instruction manual (Doc. XG0773)
Follow the instructions for the unit installation in the up to Step 1 on Page 7 of the installation guide. The unit is in place with the screws removed as illustrated there.
Installation Instruction Kit Part No. IOSK5
IOSK5-A01
IOSK5-A02
IOSK5-A03
520-551
Figure 1: Indoor/ Outdoor Sealing Kit Ccmponents
STEP 1: Back frame the unit with the metal header supplied by Montigo above the unit and either combustible or non-combustible framing to the sides and bottom maintaining clearances as shown and ensuring the gallvanized apron (Fig 1, Part No. 520-551) can be attached to the framing.
Figure 3: Attach galvanized apron to unit
Figure 4: Install silicone gasket
STEP 4: Attach the stainless steel frame (Fig. 1, Part No. IOSK5-A01) to the galvanized frame lining up the holes around perimeter. Secure in place through holes across the top and down the sides. Do not secure the bottom ange.
STEP 5: Apply approved waterproong membrane over the ange of the frame on the top and sides and under the ange of the frame at the bottom. The membrane should overlap the frame approximately 2" around the perimeter.
STEP 6: All facing materials may now be installed over the frame. BE CERTAIN TO MAINTAIN 6" ABOVE AND 3" ON SIDES AND BOTTOM TO ANY COMBUSTIBLE MATERIAL STEP 7: Mount the framed glass (Fig 1, IOSK5-A02) onto the unit and secure in place rst with only the two side screws.
Figure 2: Backframe unit CLEARANCE TO COMBUSTIBLES: 6" Top, 3" each side, 3" bottom from the protruding window box.
STEP 2: Place the galvanized apron and attach to the unit using the 6 screws removed from the unit face, Figure 3.
STEP 3: Install the silicon gasket material (supplied by Montigo) in one continuous strip with the joint at the bottom, Figure 4.
STEP 8: Place the Galvanized strips (4 supplied) at each corner lining up screw holes and secure both the strips and the framed glass to the unit.
STEP 9: Attach the stainless steel trim (Fig1, IOSK5-A03), by placing it on and ensuring the magnets catch the previously placed galvanized strip.
IOSK 520 Instructions Cont'd
ISOMETRIC VIEW
(NTS)
IOSK5-A03
IOSK5-A02
IOSK5-A01
ITEM NO.
PART NUMBER
DESCRIPTION
QTY. REV.
1
520-551
BACK PLATE
1
A
2
IOSK5-A01
OUTER FRAME, IOSK5
1
A
3
IOSK5-A02
DOOR ASSEMBLY, IOSK5
1
A
4
IOSK5-A03
DOOR TRIM ASSEMBLY, IOSK5
1
A
DIMENSIONS ARE IN INCHES TOLERANCES: FRACTIONAL
1/32"
TWO PLACE DECIMAL
.015"
THREE PLACE DECIMAL
.005"
CHECKED BY
DRAWN BY
SL/LF
DATE
NAME
10/18/2010
INDOOR OUTDOOR SEALING KIT FOR R520
73.250
30.120
2.901